| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹27.8 L+₹2.5 L (10.1%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹28.3 L+₹3.1 L (12.2%)Rejected-Finance 40 VISHNU VIHAR KHERAI SHAMSHABAD ROAD KHERAI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹29.0 L+₹3.7 L (14.8%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹30.4 L+₹5.2 L (20.4%)Rejected-Finance 06 KHASRA NUMBER 56 KIRAN NAGAR BASNI JODHPUR JODHPUR RAJASTHAN 342001 UDYAM RJ 22 0002214 | JODHPUR | RAJASTHAN | 342001 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
7 Jun 2023, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
REPAIR /REPLACEMENT OF INTERNAL WIRING OF AREA (I) INCLUDING OUT SIDE UNIT UNDER GE (AF) STN JAISALMER
2023_MES_593968_1
8911/GE/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹70,000
Yes
21 Jun 2023
9 May 2023
9 Jun 2023
9 May 2023
7 Jun 2023
24 May 2023
10 May 2023 - 13 May 2023
Amount
Taking down carefully existing unserviceable/perished conduit/ batten/ casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/ conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators etc and making good the disturbed surfaces of wall/ceiling complete all as specified & directed.
Point wiring for one light point/ fan point controlled by one, one way switch with 1.50 sqmm PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non metalic rigid PVC conduit 20mm dia with accessories fixed to cutting chases in walls by cutter and making good the surface in cement and sand mortar 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surfaces conduit with clamps, gutties etc for RCC ceiling with including cast iron/pressed steel/wooden terminal boxes (as per site requirement) including including providing new 3 mm thick plastic laminated sheet cover (Hylem) complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one 3 Pin, 5/6 Amps, socket outlet controlled by one 5/6 Amps switch on independent board complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one 3 Pin, 5/6 Amps, socket outlet controlled by one 5/6 Amps switch on same board complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one light point controlled by two way switch complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one bell/buzzer point controlled by one bell push complete all as specified and directed.
Point wiring for one 3 pin, 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non metalic rigid PVC conduit 20mm dia with accessories fixed to cutting chases in walls by cutter and making good the surface in cement and sand mortar 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surfaces conduit with clamps, gutties etc for RCC ceiling with including cast iron/pressed steel/wooden terminal boxes (as per site requirement) including including providing new 3 mm thick plastic laminated sheet cover (Hylem) complete all as specified and directed.
Point wiring for one light point /fan point controlled by one way switch with 1.50 sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade including 1.50 sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated & including suitable size module boxes for housing of modular switches, sockets, regulators including taking down old unserviceable point wiring complete all as specified & directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem /Anchor/Formica including machine screws and washer etc for fixing switches sockets etc including 1.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed.
All as per serial item No. 9.00 here-in-before but for one bell/ buzzer point controlled by one bell push complete all as specified and directed.
All as per serial item No. 9.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on same board complete all as specified and directed.
All as per serial item No. 9.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on independent board complete all as specified and directed.
All as per serial item No. 9.00 here-in-before but for one light point controlled by two way switch complete all as specified and directed.
Point wiring for one 3 Pin, 5/6 Amps socket outlet controlled by one 5/6 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 volt grade including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated & including suitable size module boxes for housing of modular switches, sockets, regulators complete all as specified and directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/Anchor including machine screws and washer etc for fixing switches sockets etc including 4 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed.
Switch piano, flush type, Single Pole, one way, 5/6 Amp, 240 Volts (ISI Marked) fixed as in repair complete all as specified and directed.
Switch piano, flush type, Single Pole, one way, 15/16 Amp, 240 Volts (ISI Marked) fixed as in repair complete all as specified and directed.
Bell push, flush type, Single Pole, 5/6 Amp, 240 volt (ISI Marked) fixed as in repair complete all as specified and directed.
Socket outlet 2 in 1, 5 pin, 15/16 Amps, flush type, 240 Volts (ISI Marked) fixed as in repair complete all as specified and directed.
Socket outlet, 2 in 1, 5 pin, 5/6 Amp, flush type, 240 Volts (ISI Marked) fixed as in repair complete all as specified and directed.
Switch piano, flush type, Single Pole, two way, 5/6 Amp, 240 Volts (ISI Marked) fixed as in repair complete all as specified and directed.
Bell Multi Music Type, AC supply, Single Pole, 240 volt (ISI Marked) fixed as in repair complete all as specified and directed.
Electronic fan regulator,Stepped type , flush type and connecting up, 120 watt, 240 volt (ISI marked) fixed as in repair complete all as specified and directed.
Modular switch 6 Amps, 240 Volt, AC, one way, one module (ISI Marked) fixed as in repair complete all as specified and directed.
Modular switch 20 Amps, 240 Volt, Single Pole, AC, one way with indicator one module (ISI Marked) fixed as in repair complete all as specified and directed.
Modular Socket shuttered, 6 Amps, 250 volts, 2/3 Pin combined, Single Pole, universal India two module (ISI Marked) fixed as in repair complete all as specified and directed.
Modular Socket shuttered, 6/16 Amps, 240 volts, 3 Pin combined, Single Pole, two module (ISI Marked) fixed as in repair complete all as specified and directed.
Modular Fan Regulator, step type, 120 Watt, 2 module, 240 volts grade, (ISI Marked) fixed as in repair complete all as specified and directed.
MCB Protected Socket (Modular AC Box, Metal clad box) Two Module, Single Pole, 20 Amps, repturing capacity 10 kA and neutral enclosure in sheet steel with a two pin and earth plug and socket including taking down old unserviceable complete all as specified and directed.
Modular Metal flush mounting box of 1/2 Module fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 3 Module fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 4 Module fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 6 Module fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 8 Module fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 12/16 Module fixed as in repair complete all as specified and directed.
White colour modular blanking plate, one module blank fixed as in repair complete all as specified and directed.
White colour plates with frame for modular switch of 1 module fixed as in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 2 module fixed as in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 3 module fixed as in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 4 module fixed as in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 6 module fixed as in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 8 module fixed as in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 2 x 6 module fixed as in repair complete all as specified and as directed.
Ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body fixed as in repair complete all as specified and as directed.
Sub main wiring with 4.00 sqmm, single core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 volts grade conforming to IS 694 including 4.00 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour included PVC casing caping / conduit and taking down old unserviceable submain wiring complete all as specified. Note : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor and PVC casing caping/ conduit shall be measured & paid as one unit.
Taking down old unserviceable bulk head and supply and fix 10 watt LED Bulk head fitting in engineering plastic housing with clear prismatic diffuser cat part No LBHP-10-CDL of make : CG or equivalent in Syska/Philips/Bajaj including LED 10 watt complete with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed.
Sub main wiring with 6.00 sqmm, single core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 volts grade conforming to IS 694 including 6.00 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour included PVC casing caping / conduit and taking down old unserviceable submain wiring complete all as specified. Note : Two run of 6.00 sqmm cable and one run of 6.00 sqmm cable as earth wire continuity conductor and PVC casing caping/ conduit shall be measured & paid as one unit.
Sub main wiring with 10.00 sqmm, two single core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 volts grade conforming to IS 694 including 10.00 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour including drawn through PVC casing caping / conduit and taking down old unserviceable submain wiring complete all as specified. Note : Two run of 10.00 sqmm cable and one run of 10.00 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
MCB, Single Pole, 6 to 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles including complete, all as specified & directed.
MCB, SPN, 40 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete all as specified & directed.
MCB, TP, 63 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 415 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete all as specified & directed.
MCB, TPN, 63 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 415 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete all as specified & directed.
LED tube light fittings of cap 10W , Two feet basic all purpose surface and wall mounted LED batten with extruded aluminium housing & integrated electronic driver with all including taking down old unserviceable LED complete all as specified and directed
LED tube light fittings of cap 20W , four feet Basic all purpose surface and wall mounted LED batten with extruded aluminium housing & integrated electronic driver with all including taking down old unserviceable LED complete all as specified and directed .
Lamp holder angular type,PVC/Polycarbonate type with back plate suitable for batten fiitng including taking down old unserviceable Lamp holder complete all as specified and directed .
Sheet metal enclosure powder coated single phase DB SPN 4 ways and neutral 240 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable DB complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB SPN 8 ways and neutral 240 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable DB complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB SPN 12 ( ways and neutral 240 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable DB complete all as specified and directed.
Sheet metal enclosure for VPTN DBs 4 way , double door, (IP-43) built in bus bars complete suitable for 415 Volts AC, 50 Hz , supply , suitable for incoming MCCB and outgoing MCBs and fixed in recess in brick masonary wall complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to and including galvanized earth lead wire 4mm dia upto 7.5 metre by means of GI nuts, bolt, check nuts, washers thimbles, etc as shown in electrical plate No 03 SSR Part I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exc 50 metre, PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe light grade 20mm bore for watering and 15mm bore meter long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25mm x 3mm, bolts, nuts and washers 75mm thick RCC cover 1:2:4 type B-1 shall be provided on CI frame etc complete all as specified. Note - (i) PCC chamber shall be constructed at least 1.5m away from the earth electrode. The pipe for watering shall be provided in slanting manner. The cost of 7.50m GI pipe for protection of earth wire/strip .(ii) Quoted amount deemed to include the cost of excavation /earthwork , PCC pit , funnel , cover GI medium grade protectiom pipe.
Single phase electronic energy meter with LCD display of rating 5-30 Amp class 1.0, 240V 50 Hz counter type display with transparent hinge including connection from SPN to meter with 6 Sqmm copper stranded conductor including earth wire complete all as specified and directed
Supply, install, testing and commissioning of LT panel size 800 mm x 600 mm x 150 mm enclosures cubical weather and vermin proof totally enclosed made out of 1.6 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door with front openable and PVC acrulic glass cover suitable size for checking of meter reading without opening door with locking arrangement incl inner shutters for mounting switch gear etc, suitable arrangement for fixing of electrical meter and SPN 40 to 63 Amp including pre wiring from Bus bar to Meter and Meter to MCB SPN (for pre wiring use 6.00 Sqmm Single core copper cable and suitable size of lugs for connecting from Busbar to meter and meter to MCB SPN)including bottom gland plate with sufficient numbers of circular cable entry holes, including prewired complete as per drawing with masonary work for fixing in wall duly powder coated with comprising of the following :-INCOMING :- (i) MCCB 63 Amps FP, 415 Volt 25 KA adjustable thermal & fixed magnetic setting Ics = 100% = 01 No . (ii) Phase indicating lamp LED type with HRC fuse – 1 Set of three. (iii) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos (iv) Aluminium bus bar 200 Amps capacity with bus bar supports, DMC/SMC insulators of CPRI approved of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos. OUT GOING ;- (i) MCB 32 Amp,415 Volt,10 KA, Single pole and neutral -04 No
MCCB, 4 Pole, 63 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC supply, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
MCCB, 4 Pole, 100 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC supply, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
MCCB, 4 Pole, 125 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC supply, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
Flameproof Fluorescent luminaire, 1 X 16 watt including LED tube, flame Proof, CMRI certified recommended for gas vapor group of IIA & IIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holder, connector block, etc and all accessorie pre-wired and incuding connecting up with twin core twisted flexible copper conductor cable with suitable size including disconnected & taking down old unserviceable light complete all as specified and directed.
Switch flame proof rotary type with termination box in LM6, 6/16 Amps, Single pole, 250 volts grade, AC supply, 50 Hz fixed as in repair complete all as specified and directed.
LED bulb 15 watt fixed as in repair complete all as specified and directed.
Attending complaints of light or power circuit due to burning/disconnecting of any wire i.e neutral phase or tripping of MCB or unserviceability of any item such as switch socket MCB etc, rectification of fault including any petty repair required to restore the electric supply for checking of existing electrical items for contineous electric supply including carrying out minor repairs such as changing of fuse, small pieces of wires etc. carrying out repairs such as tightening of loosen electric connections, nuts, bolts screws or switches, sockets, switch board, ceiling fans/exhaust fans etc. required to make the item functional during 0900 hours to 1700 hours by deploying electrician alongwith helper including necessary T&P and dismantling / Taking down complete all as specified and directed. Note :- (a) Replacement of electrical fitting/fixtures shall be measured and paid for separately under respective items. (b) Repairs/faults in any one quarter/ one occupancy shall be considered as one complaint (one measuring unit) even if repair is involved in more than one light point or fitting, however supply & fixing of fitting/ fixtures replaced shall be measured & paid separetely. (c) Number of complaint may vary day to day contractor shall quote their rates accordingly. (d) In case of failure on the part of contractor for attending complaint as penalty shall be imposed and recovered in Rs. 200/- Each complaint as specified. (e) Contractor shall ensure that the deployed electrician & helper will carry functional and live mobile phone connection while on duty and will be on contact with JE incharge/ Engineer-in-Charge. (f) Contractor shall be responsible for collection of all complaints from JE E/M and to update the states after attending /complete of the Job day to day basis. (g) The contractor shall ensure availability of all types of tools (T&P) required to attend /resolving the complaints with deployed electrician/helper
Supply only switch 5/6 Amp piano type .
Supply only socket 5/6 Amp 5 pin type .
Supply only switch 15 /16 Amp piano type complete all as specified and directed.
Supply only socket 15 /16 Amp 5 pin complete all as specified and directed.
Supply only plug top 5/6 Amp complete all as specified and directed.
Supply only plug top 15 /16 Amp complete all as specified and directed.
Supply only MCB SP 6-32 Amp complete all as specified and directed.
Supply only MCB SPN 40-63Amp complete all as specified and directed.
Supply only MCB TPN 63 Amp complete all as specified and directed.
Supply only Fan regulator elecronic step type 100 Watt switch type for single phase .
Supply only Modular swtich 5/6 amp ,AC ,One way one module complete all as specified and directed.
Supply only Modular socket 5/6 amp ,AC ,One way two module complete all as specified and directed.
Supply only Modular swtich 15/16 amp ,AC ,One way one module complete all as specified and directed.
Supply only Modular socket 15 /16 amp ,AC ,One way two module complete all as specified and directed.
Supply only Modular Fan Regulator ,AC ,One way two module complete all as specified and directed.
Supply only cable copper 1.5 sqmm single core multi stranded FRLS in 90 mtr long Roll complete all as specified and directed.
Supply only cable copper 2.5 sqmm single core multi stranded FRLS in 90 mtr long Roll complete all as specified and directed.
Supply only cable copper 4.00 sqmm single core multi stranded FRLS in 90 mtr long Roll complete all as specified and directed.
Supply only PVC rectangular block for mounting switches/socket with 3 mm plastic sheet cover of size 200X 150X 50 mm complete all as specified and directed.
Supply only PVC rectangular block for mounting switches/socket with 3 mm plastic sheet cover of size 100X 100 x 50 mm complete all as specified and directed.
Supply only PVC rectangular block for mounting switches/socket with 3 mm plastic sheet cover of size 100X 75 x50 mm complete all as specified and directed.
Supply only capacitor 2.5 mfd complete all as specified and directed.
Supply only PVC casing capping 25mm complete all as specified and directed.
Supply only PVC conduit dia 25mm complete all as specified and directed.
Supply only PVC gitti 25/35/40 mm complete all as specified and directed.
Supply only chromium plated screws 1.5'/2.5'/3' complete all as specified and directed.
Supply only white laminated sunmica sheet for mounting switches /sockets with 3mm thickness of size 4 'x4' complete all as specified and directed.
Supply only white laminated sunmica sheet for mounting switches /sockets with 3mm thickness of size 7'x 4' complete all as specified and directed.
Supply only white laminated sunmica sheet for mounting switches /sockets with 3mm thickness of size 12'x10' complete all as specified and directed.
Supply only white laminated sunmica sheet for mounting switches / sockets with 3mm thickness of size 8'x10' complete all as specified and directed.
Supply only ceiling rose 3 way complete all as specified and directed.
Supply only 05 Amp bell push switch piano type 5/6 Amp complete all as specified and directed.
Supply only multi music door bell AC 230 volt,single pole complete all as specified and directed.
Supply only 18 watt LED tube light with all fittings and fixtures complete all as specified and directed.
Taking down and refixing of old SPN DB 4Way/8Way/12Way with including mcb of any size complete including cutting chasing and refixing complete all as specified and directed.
LED downlighter Recess Mounting made out of Thermally conductive engineery plastic finished in white colour having inbuilt driver , high tranculant frosted optically diffuser, , glare free light , IP 20 , square /Round shape and white /warm white colour ( as per site requirment) having lumen output of 1800 Lumens (in CDL/ cool white colour ) including connecting up with twin core twisted flexible copper conductor cable with suitable including disconnected & taking old unserviceable light complete all as specified and directed as per crompton cat Ref LSDEP-12 CDL or equivalent in Philips/Havells
Supply and fixing LED Street Light of Capacity 30 Watt With inbuilt Driver having Pressure die cast Aluminium housing, IP-66 Having Efficiency of ≥ 100 Lumens/Watt, Operating voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D < 10 % , Suitable for 30 to 40 mm O.D Mounting Pipe and Suitable for mounting on wall/ Pole with Necessary Mounting arrangements) Including connecting up with three core twisted flexible copper conductor cable with suitable size, Mounting Pipe/ Bracket, Nut Bolts and Acessories including disconnected & taking down old unserviceable light complete all as specified and directed as per VILUMINASL30WLED757PASYBOPC or Crompton Cat No. TRP-400-30-57-SL-LM NSR or Equivalent in Philips.
LED Panel 36 watt with 2ft x 2 ft slim panel 595X595mm with Cat part no. LCTLSNE-36-FO-WW super bright surface WARM WHITE mounting LED Slim ceiling light with white powder coated extruded aluminium housing and highly efficient light smoothing optics to deliver superior illumination including LED driver and fixing in recess ceiling suitable size of aluminium strip size as required for fixing of LED fitting complete with all accessories prewired fixed on ceiling and connecting up complete with 3 core flexible cable of size 23/0.0076 including taking down old unserviceable fittings complete all as specified and directed.
Downlighter Recess, 18 Watt LED Mounting made out of Thermally conductive engineering plastic finished in white color having inbuilt driver , high transculent frosted optically diffuser, glare free light, IP-20, Square / Round Shape and White/Warm white Color ( As per Site Requirment ) having lumen output of 1800 Lumens ( in CDL/ Cool White Colour ) ) including connecting up with twin core twisted flexible copper conductor cable with suitable size including disconnected & taking down old unserviceable light complete all as specified and directed as per crompton Cat Ref LSDEP-12-CDL or equivalent in Philips/Havells
Fountain lights R G B 18 watt with all connections and necessary arrangements including taking down existing complete all as specified and directed.
Cygnus series Recess mounting LED 40 watt 2' x 2' LED Slim Panel - 595x595 mm cat Part No CCR-126-50-40-SL-NWH of make- CG electric or equivalent in Philips/Havells/CG/Bajaj white powder coated aluminium extruded housing with LEDs including LED driver and fixing in recess ceiling suitable size of aluminium strip size as required for fixing of LED fitting complete with all accessories prewired fixed on ceiling and connecting up complete with 3 core flexible cable of size 23 / 0.0076 including taking down old unserviceable fitting complete all as specified and directed.
M/s Shree Construction Company
S.D. And Company
SHREE BHAGWATI ENTERPRISES
new india engineers
Leelashah Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .