| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹7.9 L+₹98,313.20 (14.2%)Rejected-Finance | L2 | Rejected-Finance Being other than L1. | |
| 3 | L3₹9.2 L+₹2.3 L (33.5%)Rejected-Finance 2284 30 BAJRANG NAGAR VFJ ESTATE JABALPUR 482009 | JABALPUR | MADHYA PRADESH | 482009 | L3 | Rejected-Finance Being other than L1. |
Tender Value
₹8.4 L
EMD Value
₹17,000
Closing Date
7 Oct 2024, 6:00 pmClosed
AGE (I) Naya Raipur
AGE (I) Naya Raipur, Military Engineer Services, C/O HQ COSA, Near International Cricket Stadium, Atal Nagar, Raipur (CG) - 492101
As per BOQ
2024_MES_673230_1
8400/392/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AGE (I) Naya Raipur
As per NIT
7 documents required · 7 mandatory
₹500
AGE (I) Naya Raipur
₹17,000
20 Dec 2024
9 Sept 2024
9 Oct 2024
9 Sept 2024
7 Oct 2024
23 Sept 2024
Amount
Disconnecting the existing LT UG cable of any size and taking out the damaged electric UG cable from trenches complete all as specified and directed by Engr-in-charge. Note : earth work shall be measure and paid separately.
Supply, lay and testing XLPE, insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 sqmm, 3.5 core cross sectional area laid in trenches/ poles/ ducts/ pipes or through sleeves etc., including connecting/ jointing with lugs and route marker (cast iron) complete all as specified and directed by Engr-in-Charge.
Supply, lay and testing XLPE, insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 sqmm, 3.5 core cross sectional area laid in trenches/ poles/ ducts/ pipes or through sleeves etc, including connecting/ jointing with lugs and route marker (cast iron) complete all as specified and directed by Engr-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out for laying of pipe cables etc and getting out complete all as specified and directed
Returning filling in, including spreading levelling, watering and well ramming in layers not exceeding 25cm thick with earth obtained from excavation complete all as specified and as directed.
Removal of surplus excavated soil to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above starting point complete all as specified and as directed.
Material and labour for dry river washed and screened dry sand for filling in trenches/ ground 8cm thick before laying of cable and 15 cm thick after laying of cable, stretching and testing the cable complete all as specified and as directed. Note:- Punned thickness shall only be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, size 250mm x 150mm x 40mm complete all as specified and directed by Engr-in-charge.
Supply and fix light grade galvanised iron tube 80 mm bore with all fittings and fixed to walls / ceiling or laid in floor, pole or laid in trenches and road crossings including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed with walls / poles complete all as specified and as directed.
Material and labour for providing earthing for steel tabular pole complete with galvanised steel earth pleate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5mtr below normal ground level) connected to galvanised iron earth strip 32x6mm as earthing lead by means of bolts, nuts, check nuts & washers of GI or steel and connecting to earth dolly all as shown in electrical plate No 3 connected to earth test point all as specified and indicated including testing on complete all as specified and directed. Note:- Earth continuity conductor and GI protection pipe beyond 7.5m shall be measured and paid under the respective items.
Supply and fix in repairs MCCB, 4 pole, adjustable type, front operated with two suitable position, 400 amps, 50 Hz, 415 volts with rupturing capacity 35 KA complete all as specified and directed.
Supply and fix in repairs MCCB, 4 pole, adjustable type, front operated with two suitable position, 100 amps, 50 Hz, 415 volts with rupturing capacity 35 KA complete all as specified and directed.
Total contract sum shall be calculated after deduction of schedule of credit amount of Rs. 35,350.00
M/S INDIA ENTERPRISES (BID ID -3119534)
SHRI KRISHNA CONSTRUCTIONS (BID ID -3110450)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .