Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
23 Dec 2023, 6:00 pmClosed
Sh Saurabh Gupta, EE
GE(W) Colaba, Mumbai
REPAIR / REPLACEMENT OF OLD FEEDER PANEL BOX, METER PANEL, BUS BAR, EARTHING AND CONNECTED WORKS UNDER GE (W) COLABA, MUMBAI
2023_MES_630798_1
8824/E8
Open Tender
Civil Works
Item Rate
180 days
GE(W) Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(W) Colaba, Mumbai
₹96,000
Yes
6 Feb 2024
2 Dec 2023
26 Dec 2023
2 Dec 2023
23 Dec 2023
16 Dec 2023
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation and and getting out in soft/loose soil all as specified and directed.
All as per sl. item No.01 above but in hard/dense soil.
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation getting out in hard rock/road cutting/RCC/PCC all as specified and directed.
Supply and laying High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 50mm dia for laying of cable protection to walls/ trenches/floor/ceilings all as specified and directed.
Returning, filling in soft/loose soil including spreading, levelling, watering ,well ramming in layers n.exc 25 cm all as specified and directed.
Removing excavated material of soil not exc. 50m away from starting point and depositing where directed at a level not exc. 1.5m above the starting point all as specified and directed.
Removing excavated material from the site of work and transporting out side of MD land all as specified and directed.
M&L PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) in width for foundatuion/road filling and mass concrete all as specified and directed.
Taking down and up old unsereviceable cable of any size from pole wall/roof/trenches all as specified and directed.
Taking down carefully copper/aluminum submain wiring complete including all fixtures and fittings such as switches, pendant, lamp holder, regulators, switch socket outlet, bulk head fittings, tube light fittings and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces all as specified and directed
M&L in repairs for fabrication work with Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specifeid and diredted.
Dismantling of damaged/Burnt MCCB and Supply & fixing of HRC FUSE, 4 Pole,160 Amps, with MCCB 160Amp 36kA, 415Volts, 50Hz, ACs with enclosure of 2.00 mm thick for indoor S/S fixing on wall/feeder panel for inter connection of panel all as specified and directed. MAKE: As per existing make.
M&L in repairs/ Overhauling/Servicing to existing LT electric Meter panel box or any indoor type panel by taking shut down from appropiate authority including following activities (i) Tightning the loose connections and cleaning inside/out side complete replacing all cable defective glands, thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors, providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge all as specified and directed . Note : MCCB, MCB will be measured and paid separately under relevant items of this schedule.
Supply, install, testing and commissioning of LT Panel meter cabin panel indoor type, mounted on angle iron frame made out from size 40x40x5 mm grouted on floor, cubical indoor type for 415V, 3 phase, made of 2 mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 200 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections and electronic meters from old meter cabin panel and fixing/connecting in new installed panel with provisions of thimble/lugs and necessary form work and PCC foundation including shifting of existing panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :- (a) MCCB, FP, 125 Amps 36 kA- 01 Nos. Make-Legrand / Schneider / L&T (b) MCB 40 Amps, 10KA, C series - 21 Nos . Make-Legrand / Schneider / L&T (c) Digital Ammeter-01 No (d) Digital Voltmeter-01 No (e) Phase indicator lamp R,Y & B (e) Making provision for fixing of digital electronic meters removed from old panel including fixing and providing vision glasses - 21 Nos. (f) Material and labour for 2 core 10 Sqmm multistranded copper conductor cable 1100V form bus bar to electronic energy meters using suitable size copper thimbles/glads.
Supply, install, testing and commissioning of LT Panel meter cabin panel indoor type, mounted on angle iron frame made out of size 40x40x5 mm grouted on floor, cubical indoor type for 415V, 3 phase, made of 2 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 200 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections and electronic meters from old meter cabin panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary form work and PCC foundation including shifting of existing panel if any making arrengement for fixing of panel and making good to disturbed surface all as directed comprising of the following :- (a) MCCB, FP, 125 Amps 36 kA- 01 Nos. Make-Legrand / Schneider / L&T (b) MCB 40 Amps, 10KA, C series - 18 Nos . Make-Legrand / Schneider / L&T (c)Digital Ammeter-01 No (d) Digital Voltmeter-01 No (e) Phase indicator lamp R,Y & B (f) Making provision for fixing of digital electronic meters removed from old panel including fixing and providing vision glasses - 18 Nos. (g) Material and labour for 2 core 10 Sqmm multistranded copper conductor cable 1100V form bus bar to electronic energy meters using suitable size copper thimbles/glads.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated copper stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 10 sq. mm X 3 Core in service connections including taking down existing cable all as specified and as directed. Make : Polycab/ Havells/ Plaza
S&F in repairs Sub main wiring with two run of 10 sqmm stranded copper conductor FRLS wire with one run of 10 sqmm stranded copper conductor as earth continuty conductor connected to common earth dolly including PVC FR heavy duty conduit of adequate size not less than 25 mm dia for housing the wires for Main DB to House SPN DB complete all as specified. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note: Mode of measurement two runs of 10 sqmm cable and one run of 10 sqmm cable with PVC conduite shall be measured as one length.
S&F in repairs sheet metal enclosure for DB when MCBs to be used 240 volts 2 way single door without bus bar single pole and neutral fixed on wall with the help of MS flat angle iron duly grouted on wall including MS nut and bolts all as directed by engr in charge
S&F in repairs sheet metal enclosures, double door, for DBs when MCBs to be used 240 volts 4 way with 200 Amps rated bus bar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection all as specified and directed.
S&F in repairs sheet metal enclosures, double door, for DBs when MCBs to be used 240 volts 8 way with 200 Amps rated bus bar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection all as specified and directed.
S&F in repairs sheet metal enclosures, double door, for DBs when MCBs to be used 240 volts 12 way with 200 Amps rated bus bar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection all as specified and directed.
S&F in repair DB vertical type 4 way VTPN double door 415 Volts with 200 Amp rated bus bar including taking out old U/S DB & fixing on the wooden plank 15 mm thick duly grouted on wall by means of Nut & Bolts to insulate the DB from wall all as specified and directed.
S&F in repair DB vertical type 6 way VTPN double door 415 Volts with 200 Amp rated bus bar including taking out old U/S DB & fixing on the wooden plank 15 mm thick duly grouted on wall by means of Nut & Bolts to insulate the DB from wall all as specified and directed.
S&F in repair DB vertical type 8 way VTPN double door 415 Volts with 200 Amp rated bus bar including taking out old U/S DB & fixing on the wooden plank 15 mm thick duly grouted on wall by means of Nut & Bolts to insulate the DB from wall all as specified and directed.
S&F in repairs MCB TPN, 35 to 63 amps, 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs all as specified and directed.
S&F in replacement of MCCB 125A, 25kA, 4P, Thermal magnetic release , Ics=100% Icu all as specified and directed. Make : Legrand/Siemens/Schneider/ABB
S&F in replacement of MCCB 160A, 25kA, 4P, Thermal magnetic release , Ics=100% Icu . Make : Legrand/Siemens/Schneider/ABB
S&F in repairs MCB SP, 240 volt, 6 to 32 Amps all as specified and directed.
S&F in repairs MCB SPN, 240 volt, 40 Amps 10 KA all as specified and directed.
S&F in repairs MCB SPN, 240 volt, 63 Amps 10KA all as specified and directed.
Supplying, laying, commissioning & testing LT underground 70 Sqmm X 3.5 Core cables, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded aluminium conductor all as per IS 7098 (Part -1) laid in trenches, ducts, drawn through pipes or fixed on poles, as and when required on ground of following sizes .
All as per item No 36 above but 50 Sqmm X 3.5 Core
All as per item No 36 above but 35 Sqmm X 3.5 Core
All as per item No 36 above but 25 Sqmm X 4 Core
All as per item No 36 above but 16 Sqmm X 4 Core
M&L snap-on trunking system with cover, angles, bends and all accessories and fitting of size 50x80 mm fixing on wall all as specified and directed.
S&F GI perforated and ladder type cable tray of thickness size 1.5 mm and of size 150 mm X 30mm width and depth including connected other accessories by fixing srewes of adequate size and making good all as specified and directed. Note:- Rate also includes for taking down existing cables/ submain wiring and refixing the same in cable tray.
M&L in repairs for earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate not less than 1.50 m below normal ground level connected to GI earth lead strip 25 x 4 mm dia by means of GI bolts, nuts, check nuts, washers made out of GI/steel, all as shown on electrical plate No 3 of MESschedule part-I, earth lead strip connected to indicated position including concrete pit in PCC(1:3:6), type C1, precast RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe"medium grade" for watering and 40 mm dia GI pipe light grade as protection pipe, with GI funnel and wire mesh including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil all as specified and as directed and testing on completion.
S&F in repairs earth continuty conductor fixed to wall/surface or recess or burried in ground or any situation for loop earthing by aluminium 25 X 4 mm GI strip all as specified and directed.
N.S.ENTERPRISES
NOEL ENGINEERS
Ashish Enterprises
SHRI SAI ENTERPRISES
S S ENTERPRISES
Shree Ayyappa Engineering
Bidder Name
Shetty Construction Co
S S ENTERPRISES
Ashish Enterprises
SHRI SAI ENTERPRISES
NOEL ENGINEERS
Shree Ayyappa Engineering
N.S.ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .