Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹43.3 L+₹4,160.91 (0.10%)Rejected-AOC KUKURMARI HOUSE NO 0 CITY TOWN DHALIGAON P O DHALIGAON P S DHALIGAON DISTRICT CHIRANG PIN 783385 | CHIRANG | ASSAM | 783385 | L2 | Rejected-AOC L2 |
Tender Value
₹43.3 L
EMD Value
₹86,800
Closing Date
27 Jan 2023, 1:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Addl. Chief Engineer cum Director, PWD,BTC
O/o the Addl. Chief Engineer cum Director, PWD,BTC
Estimate for Set-up of Special Jail at PWD, Bodoland Guest House, Kajalgaon, Chirang under GAD, BTC for 2021-22.PKG No.56_1
2023_BTC_28880_1
No. ACE-05/CHN/IFB/2018-19/452
Open Tender
Civil Works - Building
Item Rate
180 days
Kajalgaon
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Yes
₹86,800
Yes
O/o the Addl. Chief Engineer cum Director, PWD,BTC
8 Feb 2023
14 Jan 2023
27 Jan 2023
14 Jan 2023
27 Jan 2023
14 Jan 2023
14 Jan 2023 - 21 Jan 2023
21 Jan 2023
Amount
(A) Civil Works: Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. 5.22C.1 Thermo-Mechanically Treated bars of grade Fe-500D or more.
Form Work Columns, Pillars, Piers, Abutments, Posts and Struts
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) 3 graded stone aggregate 20 mm nominal size.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes
Providing corrugated G.S. sheet roofing including vertical / curvedsurface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead, including a coat of approved steelprimer and two coats of approved paint on overlapping of sheetscomplete (up to any pitch in horizontal/ vertical or curved surfaces),excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required. 12.1.1 1.00 mm thick with zinc coating not less than 275 gm/m²
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : (b) In cement mortar 1: 4 (1 cement :4 )
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 21.3.3 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion 21.1.1.2 Powder coated aluminium (Minimum)
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.1 In stringers,, treads, landings etc. of
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: 13.98.1 One or more coats on old work
Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Supplying fitting and fixing of GI concertina razor wire for ouert fencing of top wall, etc complete as directed by the Department.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 13.98.1 One or more coats on old work
(B) Electrical Works: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.3 15/16 A switch
Suplying with including fitting fixing of LED Tube light etc as directed by the Deptt. (As per Local Market Rate)
Suplying with including fitting fixing of LED Bulb 9 Watt etc as directed by the Deptt. (As per Local Market Rate)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.4.1 4 way (4 + 12), Double door
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 2.1.2 63A TP&N
Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid Aluminium conductor up to 10 sqmm, balance stranded conductor, cores laid up, PVC tape inner sheathed, Armour (Alumuniumwire for single core up to 70 sqmm, balance Aluminium strips, Galvanised wire for cables up to 2 x 10 sqmm, 3 x 10 sqmm, 4 x 6 sqmm & balance all galvanised steel strips), extruded PVC Type ST2 sheathed, 650/1100 V grade as per IS 7908 (Part-I) 1988 armoured U.G. cable as specified and directed by the Deptt. (Havells RR, or equivalent make as approved by the Deptt.) 6.00 sqmm 2 Core U.G. cable
Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid Aluminium conductor up to 10 sqmm, balance stranded conductor, cores laid up, PVC tape inner sheathed, Armour (Alumuniumwire for single core up to 70 sqmm, balance Aluminium strips, Galvanised wire for cables up to 2 x 10 sqmm, 3 x 10 sqmm, 4 x 6 sqmm & balance all galvanised steel strips), extruded PVC Type ST2 sheathed, 650/1100 V grade as per IS 7908 (Part-I) 1988 armoured U.G. cable as specified and directed by the Deptt. (Havells RR, or equivalent make as approved by the Deptt.) 70.00 sqmm 3.5 Core U.G. cable
Supplying with fitting & fixing of LED flood light luminaire with ultra sleek \, light weight and secondary optics, made of pressure die-cast housing with IP66 ingress protection and impect resistance of IK07, 4k Vinbuilt and 10 KV external surge protection etc. as required and as directed by the department (Baja/equvalent) BJFL 50/100 W LED I (WHITE)
Supplying, fitting fixing of electric storage water Heater (Geyser) of AOS Jaquar make including necessary connection etc. as required complete and as directed by the department.
Supplying including testing and commissioning of water cooled diesel Generator set coupled complies with current CPCB-II emission norms to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f. mounted on a (1) M.S. Fabricated base frame (2) M.S. fuel of required capacity (3) Residual Silencer (Stack high shall be minimum 6.0 mtr. above the building where the gen set is installed (4) Satandar Control Panel (5) Suitable batteries with lead (6) First fill of lube oil, (7) Acoustic enclosure complete with all; accessories as specified and directed by the department conforming to IS comprising by the Technical Specification as per manufacturer (RANGE FROM 5 KVA to 625 KVA, Kirloskar KOEL, Greaves, JAKSON or equivalent alternator.) (30 KVA, 3ph water Cooled III Phase with std panel silent diesel generator set)
Wiring of circuit/submain wiring alonwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 1.14.4 2 x 6 sq.mm+1 x 6 sq.mm earth wire
Wiring of circuit/submain wiring alonwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 1.14.9 4 x 6 sq.mm+ 2 x 6 sq.mm earth wire
Supplying and fixing 5 A to 32 A rating, 240/415 Volts, 10 KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.3 Double Pole
Supllying with installation, testing and commissioning of Hi- Wall 5 star rating split type air conditioner of following capacity with cordless remote complete with copper pipe and electrical connection etc. As required complete and as directed by the Department. 1.50 Ton capacity
Supllying with fitting and fixing of 4 KVA voltage stabilizer of following specification complete with necessary electrical connection etc. As required and as directerd by the Department.( Microtec/equivalent) 4.00 KVA
Construction of D.G. Pad with shed....etc.
Babita Basumatary
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .