Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹39.7 L+₹3.6 L (9.90%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
5 Mar 2022, 6:00 pmClosed
GE PROJECT NAVY VISAKHAPATNAM
Garrison Engineer Project Navy Vizag, HQ CE Navy Complex, Station Road, Visakhapatnam, Andhra Prtadesh-530004.Tele 0891-2546410, 2543670
8779/E8 SPECIAL REPAIRS TO ORS DSC MARRIED ACCOMODATION BUILDING NO. P 28 AND P 29 AT NAD SUNABEDA
2022_MES_504583_1
8780/E8
Open Tender
Civil Works
Item Rate
180 days
Sunabeda
as per NIT/tender documents
6 documents required · 6 mandatory
₹500
Yes
GE Projects Navy Vizag
₹90,000
Yes
31 Mar 2022
2 Feb 2022
7 Mar 2022
2 Feb 2022
5 Mar 2022
21 Feb 2022
2 Feb 2022 - 17 Feb 2022
Amount
B/R PORTION
Taking down cement plaster on brick or stone wall etc including ranking out joints hacking for keys scrubbing down with water etc complete all as directed by Engineer-In-charge.
M&L for rendering 10mm thick in cement mortar 1:6 and 2nd coat of 5mm thick in cement mortar 1:4 with water proofing compound on external wall brick / concrete surfaces, finished even and smooth without using extra cement complete all as specified.
M&L for rendering 10mm thick in cement mortar 1:6 on internal wall brick / concrete surfaces, finished even and smooth without using extra cement all as specified and direced by Engr-in-Charge.
M&L for rendering 5mm thick in cement mortar 1:3 on Ceiling brick / concrete surfaces, finished even and smooth without using extra cement all as specified and direced by Engr-in-Charge.
M&L for preparation of new plastered external surface applying two coats of weather shield ultra exterior premium emulsion paint over a coat of exterior primer complete all as specified and directed by Engr-in-Charge.
Preparation of new plastered surface of wall and applying two coat of acrylic oil bound distemper over a coat primer and including coat of wall care putty complete all as specified and as directed
M & L for Preparation of new plastered surface of Ceiling and applying three coat of white wash on Ceiling all as specified and directed by Engr-in-Charge.
Dismantling of floor hearth or wall tilling including cement mortor bedding and removing rubbish off the premises all as specified and directed by Engr-in-Charge
M & L for screed bed or bedding layer of mortar 15mm thick for laying floor finishes etc in cement mortar 1:6 complete all as sdpecified and as directed.
M & L for rendering to brick/ concrete surface 10mm thick in cement mortar 1:4 surfaces finished fair and even and scoured for fixing tiles/ stone slabs etc complete all as specified and as directed
M&L for non skid ceramic coloured tiles 300x300x7mm thick in floors, etc. set and jointed in neat cement slurry and pointed in cement to match of size of tile complete all as specified and directed by Engr-in-charge)
M & L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, (400mmx400mmx7mm) in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed by Engr-in-Charge.
M & L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in vertical surface as skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge.
M&L for glazed ceramic tiles (coloured) 450mm x 300mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed by Engr-in-Charge.
M & L for cooking platform of Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-Charge.
M & L Reinforced cement concrete (Nominal mix) in type B1 (1:1.5:3) (20 mm graded aggregate) precast Slab supported on walls, beams, and columns in floors, roofs, landings, balconies, canopies, deck slab and in shelves and the like complete all as specified and directed.
M&L for form work to sides and soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work; note exceeding 200mm thick (Horizontal or sloping) all as specified and directed by Engr-in-Charge.
M&L for mild steel TMT bars 10mm dia & over cut to length bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and bending with and including MS wire (annealed) not less than 0.9 mm dia, complete, all as specified and directed.
Demolition of reinforcement cement concrete of any description from any position including removing the demolition material complete all as specified and as directed.
M & L Reinforced cement concrete (Nominal mix) in type B1 (1:2:4) ( 20 mm graded aggregate) Chajjas and the like all as specified and directed by Engr-in-Charge.
M&L Formwork to chullah hoods and Chajjas, thoughs and similer Items including edges complete all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete 75mm thick type C-1 1:3:6 (using 20mm graded stone aggregae as in path, plinth protection or hardstanding finish even and smooth surface without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete type E-2 (1:5:10), using 40mm graded granite stone aggregate as in sunken floor, filling & mass concrete for sunken floor etc., including demolition of existing floor, complete all as specified.
M&L applying a coat of water proofing chemical NITTO PROOF 120 over a coat of NITO primer on concrete / plaster surface, including cleaning the surface with wire brush complete all as directed and as per manufacturer's instructions, complete all as directed by Engineer-in-Charge. Note : Sunken floor shall be tested for leakage with water ponding for 48 hours complete all as specified and directed.
M&L for Rendering 10mm thick on fair faces of brick / concrete surfaces in CM1:4, with and including mixing of water proofing compound @ 2% by weight of cement, for both floor and sides of suken floors, complete all as specified. (Water proofing compound measured sepreatally).
Material and labour for 30mm thick PCC 1:2:4, type B-0, using 12.5mm graded aggregate as in sunken floor flooring complete all as specified and as directed.
Supply only integral water proofing compound (ISI marked) of approved make.
S&F in repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, 'P' or 'S' trap, including connection to trap and flushing pipe, antisyphonage pipe etc including provision of PCC (1:5:10) type E2 in filling, making good to floor, complete all as specified.
Supply and fix in repairs 10 Liters capacity, low level flusing cistern, PVC, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe complete all as specified and as directed.
Taking down of steel tubing 15mm dia of pipe and connections removal to store complete all as specified.
All as per item No.1.29 here-in-above but 20mm dia pipe.
All as per item No.1.29 here-in-above but 25mm dia pipe.
Refixing old steel tubing and connection in new or old position (wall, ceiling, floor etc) of 15mm bore of pipe including cleaning for complete all as specified.
All as per item No.1.33 here-in-above but 20mm dia pipe.
All as per item No.1.33 here-in-above but 25mm dia pipe.
Supply and fix GI water tubing of 15mm dia, medium grade, concealed Type conforming to IS 1239 (Part-1) including all fitings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc and fixed to walls, celling or laid on floors including testing complete all as specified and directed.
All as per item No.1.36 here-in-above but 20mm dia pipe.
All as per item No.1.36 here-in-above but 25mm dia pipe.
S & F in repairs chromium plated shower roses 125mm size with or without swivel joints including fixing to steel pipe or union complete all as specified and directed.
Supply and fix in repairs, bib taps, cast copper alloy, 15mm dia, fancy type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified and as directed.
Supply and fix in repairs, stop valves, 15mm dia, cast copper alloy with capstan head, chromium plated, screwed down high pressure with crutch or butterfly handle with long shank and cup (concealed type) for iron pipe etc complete all as specified and as directed.
Supply and fix in repairs PVC connection of 15mm bore and 450mm long with brass check nut and union etc complete all as specified and as directed.
S&F Towel rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) as in repairs complete all as directed.
S&F as in repairs sink with drainage board made of stainless steel 1mm thick for kitchen with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or with & including fixing cantilever brackets and connecting union to pipe, overall size 915 x 460 mm bowl size 410 x 330 x160 mm including waste pipe of polythelene of low or high density or PVC 32mm dia & waste fitting brass chromium plated for 32mm bore with long screwed shanks and fly nuts including making holes in stone walls for brackets and fixed in CM 1:3 or PCC 1:2:4 type B0 complete all as specified and as directed.
S&F ball brass valves, 20mm, high pressure, with polyethylene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in repair complete all as specified.
M & L in repair for 75mm PVC (SWR) floor trap or Nanhi trap, plain with grating including jointing with solvent cement complete all as directed by Engr-In-Charge
Supply and fix in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls including necessary brackets clamps or laid in trenches incl taking down the old unserviceable pipe complete all as specified and as directed.
Supply and fix 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls including necessary brackets clamps or laid in trenches incl taking down the old unserviceable pipe complete all as specified and as directed.
Supply and fix 75mm bore PVC (SWR) bends with gate of any radius complete all as specified and as directed.
Supply and fix 110mm bore PVC (SWR) bends with gate of any radius complete all as specified and as directed.
Supply and fix 75mm bore PVC (SWR) junction single (Single "T") equal or unequal with access door complete all as specified and as directed.
Supply and fix 110mm bore PVC (SWR) "T" of any radius complete all as specified and as directed.
Supply and fix 75mm bore PVC (SWR) vent cowl complete all as specified and as directed.
All as per item No.1.54 here-in-above but 110mm bore.
Taking down chowkat or frame with shutters area not exc. 1.5 Sqm each (without taking off the wooden shutters from the frame) including cutting holes for hold fasts complete all as specified
Taking down shutters of any description exc 1 Sqm and not exc. 2 Sqm each complete all as specified.
Taking down of shutters of any description not exceeding 1.00 Sqm each including iron mongery complete all as specified
Taking down chowkat or frame with shutters area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the wooden shutters from the frame) including cutting holes for hold fasts complete all as specified.
M& L for 2nd class hard wood as in plain solid, straight chowkhats and frames, wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints including taaing back of chowkhat/frame complete all as specified and as directed by Engineer-in-Charge.
M & L for factory made, 35mm thick glazed and Skelton shutter of 2nd class hard wood open rebated and prepared to receive glass, gauge etc (with out shash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc, size of members of shutter as specified in SSR Part-I (2009) section 8-24(a), chemically treated and fitted to chowkhat complete all as specified and as directed by Engineer-in-Charge.
S&F Factory made Plain framed, panelled shutters, 35 mm thick of second class hard wood (Hollock) (any numbers of panels) with panels of 9mm BWP commercial ply or 12 mm thick veneered particle board exterior grade medium density with commercial veneering on both faces with sheesham wood beading all round the panel made out of 20 by 15 mm , on one side and fitted to chowkhats complete all as specified and directed.
M&L for 75 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified and as directed.
M & L in repairs 18/19mm thick veneered particle board solid core interior grade with decorative face veneers on one face fixed with screws to frame work as in pelmet boxes, etc all as directed by Engineer in Charge
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour sheets for top rail lock rail bottom rail on either side and as gap insert for Top rail and bottom rail paneling of plain colour PVC sheet to fitted on the MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and directed.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening & edges shall be painted to match with printed sheet as per specifications inluding making good the disturbed surface to match the existing for toilet complete al as specified and directed by Engineer-in-Charge.
S&F 3mm thick sheet glass of ordinary quality and glazing with oil putty or wooden beading to wooden frame or steel frame in square n. exc 0.5 Sqm in each pane complete all as specified and as directed by Engineer-in-Charge. Make: HINDUSTAN PILKINGTON GLASS / MODIGUARD
S&F Frosted glass 4mm thick, ordinary quality and glazing with and including wooden beads in squares not exceeding 0.5Sq.m in each pane, complete all as specified. Make: HINDUSTAN PILKINGTON GLASS / MODIGUARD
Supply and fixing Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified.
S&F as in repairs curtain rod of 18mm dia, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified & as directed.
M & L for 300mm long MS helical door tail pattern springs ISI marked, incl roller and roller plate and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.
M & L for mild steel framed work such as grills, gratings, guard bars etc.. with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work, conforming to Fe 290 Gde E-165, including dismantling old work of any description, complete all as specified and as directed.
M&L for PCC (1:3:6) type C-1, using 20mm graded stone aggregate as in coping benching and bed blocks etc including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished rough complete all as specified.
Supply and fix mild steel work as in hold fasts, fencing, wall ties etc., and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified.
Mild steel sliding door bolts 300mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified.
S & F of 75mm Butt hinges, med weight, alluminium, and fixed complete all as specified.
S & F of 100mm Butt hinges, med weight, alluminium, and fixed complete all as specified.
S & F 100 mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified.
S & F 150 mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified.
S & F 200 mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified.
S & F 150mm Aluminium handles, cast type, anodised complete all as specified.
S & F 200mm Aluminium handles, cast type, anodised
S&F aluminium alloy hasp and staple safety type with hinge pin incl bolt to hinge plate with screw 100mm long size complete all as specified.
Repairs to structural members like columns, beams, slab by removing the corrosion from reinfrocement and applying one coat of nito zinc primer or equivalent to renforcement and applying one coat of NITOBOND SBR or equivalent to old concerete and applying cement concrete 1:1.5:3 using 6mm aggregate and approved Fosroc or equivalent chemical for additional strength including necessary formwork as required the thickness of concrete is 15mm to 50mm as per requirement at site (Nitobond EP & Nitobond SBR) all as specified and directed By Engr - in- Charge.
M&L for Small fittings of 2nd class hard wood such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles exc 200 and not exc 500 cu. cm each complete all as specified.
M&L for preparation of new wooden Surfaces and applying two coats of synthetic enamel paint over a coat of pink primer of any description, not otherwise described, over 10cm width or girth complete all as specified.
M&L for preparation of old wooden Surfaces and applying one coat of synthetic enamel paint of any description, not otherwise described, over 10cm width or girth complete all as specified.
M&L for applying two coat of synthetic enamel paint on new steel surface over a coat of red oxide incle preparation of surface of any description over 10 cm width or girth complete all as specified.
M&L for applying one coat of synthetic enamel paint to old Steel surface incl preparation of surface of any description over 10 cm width or girth complete all as specified.
S&F Rotational moulded polyethlene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I 500 litres capacity including disconnecting of old Tank any description and Removal fron the site all as specified and directed by Engr-in-Charge.
Demolition of cement concrete of any description from any position including removing the demolition material complete all as specified and as directed.
M & L Cement concrete type B1 1:2:4 (20 mm graded aggregate) as in roof padding, roof kerbs or mud stops all as specified and directed by Engr-in -Charge.
M & L for water proofing treatment as under (a)Complete removal of existing damaged roof treatment and roughening, including removal of rubbish (b) preparing the surface of roof brusing neat cement slurry @ 3Kg of cement per sqm and PCC padding (PCC padding paid and measured sepratelly) (c) 10 mm thick cement screed bed in CM 1:4 on concrete surface when concrete is green including finish even and smooth and including WPC @ 2% by weight of cement (c) Applying a coat of hot blown bitumen of grade 85/25 @ 1.2 Kg/Sqm over bitumen primer @0.50 ltr/Sqm as bonding material (d) APP membrane with a centre core of 90 micron thick HMDHDE film, reinforced with sandwitched polethene film/ non woven polyester having weight not less than 3.0 kg with LPG torch application, with and including coat of blown bitumen of grade 85/25 or 90/15 @ 1.2 kg/Sqm at top of the membrane and finally after drying finishing with a coat of aluminium primer @ 0.1 Ltr/Sqm on top, including sealing all joints by thermo fusion, complete all as per manufacturer instructions all as specified and directed by Engr-in-Charge.
E/M PORTION
Taking down carefully copper / aluminium point wiring Surface/Concealed [light, fan, socket, ceiling or power] complete including fittings, switches, ceiling roses, pendents, regulators, sockets, holders etc., and making good the disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.
M & L for point wiring complete with 1100 Volt grade, 1.5 Sq.mm single core PVC insulated unsheathed cable, copper conductor multistranded, ISI marked passing through and including heavy duty PVC conduit, 20mm dia with all accessories concealed type on wall / floor with MS Box duly painted with 2 coats of synthetic enamel paint over a coat of primer with 3mm thick hylam sheet top cover duly earthed with 1.5 Sqmm, PVC insulated unsheathed cable, copper conductor, multistranded for one light point / fan point/Exhaust fan point/ bell point/ Bldg Security light point controlled by one switch complete all as specified and as directed.
All as per Item No.2.02 above but for 3 pin, 5 Amps switch socket on same board.
All as per Item No.2.02 above but for 3 pin, 5 Amps switch socket on independent board.
All as per Item No. 2.02 hereinbefore but of cable 2.5 Sqmm, duly earthed with 1.5 Sqmm, PVC insulated unsheathed cable, copper conductor, multistranded for multipurpose 3 pin, 15 Amps and 1 pin, 5 Amps switch socket on independent board complete all as specified and as directed.
All as per Item No. 2.02 hereinbefore but one light point controlled by two way switch with cable 1.5 sq mm complete all as specified and as directed.
S & F in repairs switch socket outlet 3 pin, 5 Amps, 230 Volts, flush type complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs switch socket outlet multipurpose 3 pin, 15 Amps and 1 pin 5 Amps, flush type controlled by one switch complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs switch paino flush button, single pole one way, 5 Amps, 230 Volts complete all as specified and as directed.
S & F in repairs switch paino flush button, single pole two way, 5 Amps, 230 Volts complete all as specified and as directed.
S & F in repairs Bell push, flush type, 5 Amps complete all as specified and directed.
S & F in repairs fan regulator AC, 230 Volts, single pole, electronic type complete all as directed.
S & F in repairs ceiling rose surfaces bakelite 65x50mm three terminals, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs energy efficient light emmitting fluorescent light fitting 1x18/20 watt, four feet , white fittings with LED rod complete with all accessories & Provn of three core cable of copper conductor of size 0.75 sqmm, making necessary electric connetion from ceiling rose to fitting terminal , fixing the fitting on wall including all necessary fixing accessories complete all as directed.
S&F in repair for energy efficient light emmitting fluorescent light fitting 1x10 watt Two feet LED tube light with LED rod complete with all accessories & Provn of three core cable of copper conductor of size 0.75 sqmm, making necessary electric connetion from ceiling rose to fitting terminal , fixing the fitting on wall including all necessary fixing accessories complete all as directed.
S & F in replacement of 7W LED Lamp 220-240V AC 50Hz (85% more energy saving as compared to incandescent lamp Make Bajaj, CG, Phillips or equivalent MES approved) complete all as directed.
S&F in repair for energy efficient light emmitting for high efficiency surface LED Bulk Head light fitting 1x 6 Watt complete with all accessories luminaire with CRCA powder coated body & Provn of three core cable of copper conductor of size 0.75 sqmm, making necessary electric connetion from ceiling rose to fitting terminal , fixing the fitting on wall including all necessary fixing accessories complete all as directed (Make- Cat No : CG 80IB6W LED of C & S or equivalent Make of Wipro/Havells or Equivalent MES approved make.
S & F in repairs lamp holder, insulated body with back plate, 230 Volts for batten fittings complete all as specified and as directed by Engineer-in-Charge.
S & F Bell, ding dong, AC, 230 Volts, single complete all as specified and as directed by Engineer-in-Charge.
Taking down Existing Exhaust Fans any make and size/any condition, keeping at site for reuse, refixing the same in serviceable condition after completion of repair works in old or new location complete all as directed.
Taking down Existing Ceiling Fans any make and size/any condition, keeping at site for reuse, cleaning, refixing the same in serviceable condition after completion of repair works in old or new location complete all as directed.
S & F MCB DB, SPN, 8 way 240 Volts, 50 Hz, single phase, AC supply including 200 Amps rated bus bar with sheet metal enclosure including taking down old unserviceable MCB DB and with the following :- [a] MCB SPN 32 Amps - 01 No. [b] MCB SP 6 to 32 Amps - 06 Nos
S & F MCB DB, TPN, 4 way 240 Volts, 50 Hz, three phase, AC supply including 200 Amps rated bus bar with sheet metal enclosure including taking down old unserviceable MCB DB and with the following :- [a] MCB TPN 63 Amps - 01 No. [b] MCB SPN to 32 Amps - 08 Nos
Supply and lay of LT UG cable XLPE with aluminum conductor, Screened bedded multistranded 1100 volts grade in Galvanised steel strip or wire armored, heavy duty electric power cables with stranded aluminium conductor, cross-sectional area of size 25 sq mm 3.5 Core as in repairs complete all as specified.
Supply and lay of LT UG cable XLPE with aluminum conductor, Screened bedded multistranded 1100 volts grade in Galvanised steel strip or wire armored, heavy duty electric power cables with stranded aluminium conductor, cross-sectional area of size 16 sq mm 4 Core as in repairs complete all as specified.
Supply and fix in repairs for Sub main wiring with 2 runs of single core, 4 Sqmm PVC unsheathed, copper multistranded conductor in concealed conduit, ISI marked, drawing into and including PVC heavy duty conduit, 25 mm dia with all accessories, surface type duly earthed with 2.5 Sqmm, single core, PVC insulated unsheathed cable, copper conductor, multistranded complete all as specified and as directed. Note :- 2 run of 4 Sqmm & 1 run of 2.5 Sqmm and one run of PVC conduit will be measured as one unit.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics as in repairs complete with IP 65/66 protection complete all as directed
Supply and fix FRP cable looping box of size 250 x 250 x 105 mm With connector block 4 Way , including provision for 1 Nos of MCB SP 6 Amp, copper shorting strips etc including suitable stainless steel gland, including provision for connecting earth continuity conductor etc. as in repairs complete all as specified and directed.
S & F GI Bracket made out of 40 mm dia medium grade GI tube up to 1.5 m long bend to shape 115 degree off set shape, fixed with 2 nos of suitable MS Flat clame of size 40x6 mm with necessary nut bolts & washers and applying two coats of aluminum enameled paint over one coat of zinc oxide primer for clamp as in repairs complete all as specified and directed.
Supply & lay / passing through pipes cable PVC insulted & PVC unsheathed 650 / 1100 Volt Grade As per IS 694 multistranded copper conductor of size 3 core 1.5 Sq mm. for interconnection of cable looping box to street light fitting/ security light etc in and including PVC conduit 19 mm internal dia as in repairs complete all as specified and directed.
Dismantling and taking out of steel poles of any size complete all as directed
Supply and errection of Steel tubular swaged pole 9metre long complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31, including two coats of aluminium paint over a coat of red oxide primer, complete all as specified. Note: Earth work excavation, PCC and coping shall be measured and paid separately. Make: Jindal Steel / National Tubing Co. / Bombay Tubes & Store / Calcutta Poles & Tubes.
Cutting existing road and laying of GI pipe and filling with PCC (1:2:4) type B2 using 40mm garded aggregate as in surface etc complete all as specified and directed.
Supply and laying GI pipe 80 mm dia Light gade with all fittings laid in road cutting for cable portection for pipe required for supporting the light fittings as in repairs complete all as specified and directed.
M&L for water tubing 25 mm (1”) dia.bore, galvanised iron, medium grade, ISI Marked, laid in trench and the like with all fittings such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps plugs and unions etc.,complete all as specified. Make: JINDAL / PRAKASH / ZENITH
M&L for water tubing 20 mm (¾”) dia.bore, galvanised iron, medium grade, ISI Marked, laid in trench and the like with all fittings such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps plugs and unions etc.,complete all as specified. Make: JINDAL / PRAKASH / ZENITH
Taking up or down steel tubing and connections of 25mm size complete all as directed
Taking up or down steel tubing and connections of 20 mm size complete all as directed
M&L for Gun metal globe or gate valves (Class-I) with iron wheel head, scrwed both ends, including GI Nipple & unions for iron pipe of 25mm dia, fixed as in repair, complete all as specified and directed for the following sizes:- Make: VARUN / LEADER / L&T / UPADHYAY/ ZOLOTTO
All as per serial item No.2.39 here-in-above but of size 20 mm dia
Cutting existing pipe line Screwing existing steel tubing for alterations or additions necessarily done in position without taking down and inserting Tee of 50x50x25mm for tapping all as specified and directed.
M&L for Plain Cement concrete type C-2, 1:3:6, using 40mm graded granite stone aggregate as in foundations, fillings and mass concrete, complete all as specified
M&L for Plain Cement concrete type B-1, 1:2:4, using 20mm graded granite stone aggregate as in coping, including use and waste form work and finishing the exposed faces of concrete even and smooth without using extra cement, complete all as specified.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for taking out/laying cable and getting out, in Hard / Dense Soil.
Returning, filling including spreading leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point.
Supply spreading in trenches fine dry crushed stone sand for cable protection and punning down gently by hand all complete all as specified.
Supply and laying reinforced precast concrete cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified.
Supply and istallation feeder pillar box outdoor type made out of CRCA sheet 2.0 mm thick of suitable size but not less than 0.25x0.25x0.3m size outdoor Pedestal type totally enclosed made of rust proof material incl Aluminium bus bar with suitable for three phase and four wire LT AC, 50 Hz 415 V with MCB TPN 63 Amp -01 No (incomer) Cat No BB40630B of L&T, MCB TPN 40A, Cat NoBB40400B of L&T-04 Nos (One spare), 3 pole ML-3 contactor Cat No SS90721 of L&T 40A upto 415V 50 Hz ,street light Digital electronic type Timer switch -01 No of Cat No 67DDT0 of L&T with LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases as in repairs complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead Strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion as in repairs complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion and earth work as in repairs complete all as specified and directed.
M/S SANTOSH SATAPATHY
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .