Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.5 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Being Lowest Tenderer | |
| 2 | L2₹71.8 L+₹5.9 L (8.94%)Rejected-Finance | L2 | Rejected-Finance Being other than Lowest Tenderer | |
| 3 | L3₹76.3 L+₹10.3 L (15.7%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L3 | Rejected-Finance Being other than Lowest Tenderer | |
| 4 | L4₹80.7 L+₹14.8 L (22.4%)Rejected-Finance | L4 | Rejected-Finance Being other than Lowest Tenderer | |
| 5 | L5₹89.3 L+₹23.3 L (35.4%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L5 | Rejected-Finance Being other than Lowest Tenderer |
Tender Value
₹94 L
EMD Value
₹1.9 L
Closing Date
16 May 2023, 6:55 pmClosed
Lt Col Ng Rajesh Singh GE NW KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8928 REPAIR MAINTENANCE OF VARIOUS LT PANELS MCCB AND DISTRIBUTION BOARDS AND CONNECTED ITEMS AT VARIOUS CASSIONS AND SUBSTATIONS AT VAROIUS DOCKS AT NAVAL DOCKYARD UNDER GE NW KUNJALI
2023_MES_589971_1
8928/E8
Open Tender
Civil Works
Item Rate
270 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) KUNJALI
₹1.9 L
Yes
21 Oct 2023
18 Apr 2023
18 May 2023
25 Apr 2023
16 May 2023
2 May 2023
18 Apr 2023 - 25 Apr 2023
Amount
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, out door type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet, front & back openable doors having vertical COPPER bus bar of capacity 1200 amps for phases and for neutral including powder coated BLUE colour painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER a) ACB 800Amps 4pole,50 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING c) MCCB, 4 pole 630 Amps,36KA,Thermal magnetic - 1Nos (Out going) d)MCCB, 4 pole 400 Amps,25KA,Thermal magnetic - 2Nos (Out going) f) VAF meter class 1with CT's - 1 No g) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, out door type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet, front & back openable doors having vertical COPPER bus bar of capacity 800 amps for phases and for neutral including powder coated BLUE colour painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at East wall including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER a) MCCB 400Amps 4pole,36 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING c) MCCB, 4 pole 250 Amps,25KA,Thermal magnetic - 1Nos (Out going) d)MCCB, 4 pole 100 Amps,16KA,Thermal magnetic - 2Nos (Out going) f) VAF meter class 1with CT's - 1 No g) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, out door type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet, front & back openable doors having vertical COPPER bus bar of capacity 1600 amps for phases and for neutral including powder coated RED colour painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER a) ACB 1250Amps 4pole,50 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING c) MCCB, 4 pole 630 Amps,36KA,Thermal magnetic - 1Nos (Out going) d)MCCB, 4 pole 400 Amps,25KA,Thermal magnetic - 3Nos (Out going) e)MCCB, 4 pole 100 Amps,25KA,Thermal magnetic - 2Nos (Out going) f) VAF meter class 1with CT's - 1 No g) Indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, out door type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet, front & back openable doors having vertical COPPER bus bar of capacity 800 amps for phases and for neutral including powder coated BLUE colour painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER a) MCCB 600Amps 4pole,36 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING c) MCCB, 4 pole 400 Amps,36KA,Thermal magnetic - 2Nos (Out going) d)MCCB, 4 pole 250 Amps,25KA,Thermal magnetic - 2Nos (Out going) f) VAF meter class 1with CT's - 1 No g) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, out door type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front & back openable doors having vertical COPPER bus bar of capacity 630 amps for phases and for neutral including powder coated RED colour painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at North wall including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER a) MCCB 250Amps 4pole,36 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING c) MCCB, 4 pole 125 Amps,25KA,Thermal magnetic - 2Nos (Out going) f) VAF meter class 1with CT's - 1 No g) Indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, out door type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet, front & back openable doors having vertical COPPER bus bar of capacity 1600 amps for phases and for neutral including powder coated RED colour painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER a) ACB 1250Amps 4pole,50 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING c) MCCB, 4 pole 400 Amps,36KA,Thermal magnetic - 3Nos (Out going) e)MCCB, 4 pole 100 Amps,25KA,Thermal magnetic - 2Nos (Out going) f) VAF meter class 1with CT's - 1 No g) Indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, out door type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front & back openable doors having vertical Copper bus bar of capacity 1000 amps, 60Hz for phases and for neutral including powder coated Red colour painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER a) MCCB, 4 pole 630 Amps,36KA,Thermal magnetic - 1Nos OUTGOING a)MCCB, 4 pole 400 Amps,25KA,Thermal magnetic - 1Nos (Out going) c) MCCB, 4 pole 250 Amps,25KA,Thermal magnetic - 2Nos (Out going) f) VAF meter class 1with CT's - 1 No g) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, out door type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front & back openable doors having vertical COPPER bus bar of capacity 630 amps for phases and for neutral including powder coated RED colour painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at North wall including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER a) MCCB 250Amps 4pole,36 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING c) MCCB, 4 pole 125 Amps,25KA,Thermal magnetic - 2Nos (Out going) f) VAF meter class 1with CT's - 1 No g) Indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of Feeder piller box for looping of cables , out door type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front & back openable doors having vertical copper bus bar of capacity 2500 amps for phases and for neutral including powder coated painting, PCC foundation, supporting channels,cable termination,cable gland etc complete at jetty/casin including taking down old panel all as directed.
Supply, fabrication, installation, testing & commissioning of Feeder piller box for looping of cables , out door type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front & back openable doors having vertical copper bus bar of capacity 800 amps for phases and for neutral including 400Amps 4 pole 36kA AC/DC MCCB powder coated painting, , PCC foundation, supporting channels,cable termination,cable gland etc complete at jetty/casin including taking down old panel all as directed.
S&F in repair of double door type ETPN DB 8 Way ,240V with 200A busbar , with metalic double door type IP 43 IK 09 protection suitable for housing MCCB's all as specified and directed by EIC.Make: Legrand cat No 507782/Seimens/C&S. Note : DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S&F in repair of double door type ETPN DB 6 Way ,240V with 100A copper busbar , double door type IK 09 protection suitable for housing MCCB's all as specified and directed by EIC.Make: Legrand cat No 507781/Seimens/C&S. Note : DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S&F in repair of double door type SPN DB 04 Way ,240V with 100A copper busbar each phase , with metalic double door type IP-43 IK 09 protection suitable for housing MCB's all as specified and directed by EIC. Make: Legrand cat No 507611 /Seimens/C&S. Note : MCB DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S&F in repair of double door type SPN DB 02 Way ,240V with 100A copper busbar each phase , with metallic double door type IP-43 IK 09 protection suitable for housing MCB's all as specified and directed by EIC. Make: Legrand cat No 507611 /Seimens/C&S. Note : MCB DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S & F MCCB FP 200 Amps,16KA, complete all as specified and directed. Make : Legrand cat No 420016/Seimens/C&S
S & F MCCB FP 250 Amps,16KA, complete all as specified and directed. Make : Legrand cat No 420016/Seimens/C&S
S & F MCCB FP 400 Amps,25KA, complete all as specified and directed. Make : Legrand cat No 420016/Seimens/C&S
S & F MCB SP 6-32 Amps,10KA, 'C' series 240V complete all as specified and directed. Make : Legrand/Seimens/C&S
S & F MCB SPN 40-63 Amps,10KA 'C' series 240V complete all as specified and directed. Make : Legrand/Seimens/C&S
S & F MCCB FP 1250 Amps,16KA, complete all as specified and directed. Make : Legrand cat No 420016/Seimens/C&S
S & F MCCB FP 1000 Amps,16KA, complete all as specified and directed. Make : Legrand cat No 420016/Seimens/C&S
S&F in repairs of 0.71mm thick powder coated aluminium sheet cover, alloy 31000 H4 in tray cover including suitable size of revets/nut bolts complete bending, shaping, drilling, cutting notching and all as specified and directed by EIC.
Supply and fixing in repair walll/surface mounted 10W LED batten fitting engineering plastic battern with white acrylic cover complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed by Engr-in-Charge. Make : CG/wipro/C&S cat No LTTB2F10WLEDW BATTEN/Bajaj/Havells/Philips
Supply and fixing in repair wall/surface mounted 20W LED batten fitting engineering plastic batten with white acrylic cover complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed by Engr-in-Charge. Make : CG/wipro/C&S cat No LTTB4F20WLEDEW BATTEN/Bajaj/Havells/Philips
Supply and fix vable jointing STRAIGHT THROUGH JOINT complete with jointing material (Heat srinkable) for 1100V grade cable for XLPE armoured alluminium conductor cable of size 120 to 185 sqmm 3.5 core complete all as specified and directed. Make : Rychem/3M
Supply and fix vable jointing STRAIGHT THROUGH JOINT complete with jointing material (Heat srinkable) for 1100V grade cable for XLPE armoured alluminium conductor cable of size 240 to 400 sqmm 3.5 core complete all as specified and directed. Make :Rychem/3M
Supply and fix vable jointing STRAIGHT THROUGH JOINT complete with jointing material (Heat srinkable) for 1100V grade cable for XLPE armoured alluminium conductor cable of size 95 to 120 sqmm 3.5 core complete all as specified and directed. Make :Rychem/3M
S & F in repair of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A all as specified and directed by EIC. Make: Siemens/Legrand/C&S.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : 1. The cost of thimbles/lugs and cable gland etc shall be deemed to be included in quoted unit rate and no extra payment will be made for the same.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : 1. The cost of thimbles/lugs and cable gland etc shall be deemed to be included in quoted unit rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : 1. The cost of thimbles/lugs and cable gland etc shall be deemed to be included in quoted unit rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : 1. The cost of thimbles/lugs and cable gland etc shall be deemed to be included in quoted unit rate and no extra payment will be made for it.
Excavation in trenches n exc1.5m wide and n exc in depth for laying of cables and getting out in loose/soft soil complete all as directed.
Returing filling in including spreading, levelling watering and well ramming in layers not exc 25cm complete all as directed.
Removing excavated material n exc 50cm and deposting where directed at a level n exc 1.5m above the starting point complete all as directed.
Material and labour for sand filling in trenches fine dry sand as sand cushioning to cable 8 cm before laying of cables and 15 cm after laying cable which shall be punned down to 10 cm complete all as specified and directed. (Note : Only punned down thickness shall be measured and paid)
Supply and layingreinforceced precast concrete cable cover, class LV, type I, flat size 250mmx150mmx40mm laid across the cable complete all as specified and directed.
M&L for GI pipe light grade 100mm dia for protection of UG cable crossing of nallah/ bridge/road etc complete all as directed.
S & F in repair to double wall corrugated pipes 100mm dia for cable protection as per IS 16098 (Part 2), ISO 21138 (Part 3) all as directed
S & F in repair to double wall corrugated pipes 150mm dia for cable protection as per IS 16098 (Part 2), ISO 21138 (Part 3) all as directed
M&L cement concrete in 1:2:4 type B1 using 20mm grade stone aggregate for road cutting/pole couping exposed surfaced and fair and even finishing with out using any extra cement etc complete all as specified and directed
M & L for painting of LT panel, cope points, hydrant box as per approved colour (Red/Green, Blue) with 02 coat of red oxide and 01 coat acrylic weather proof paint all as directed and specified including scraping off old paint and along with new stickering as per existing.
Supply , fixing, testing in repairs of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 25 mm dia with 250 micron ( avera Schneider ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF Powerfill Loresco compound shall be supplied in 50 Pound Bag. ( 1 Bag of 50 Pounds required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set alongwith earth pit weatherproof incl all as specified . Note - Back-fill compound shall not be mixed with any soil while pouring in the bore hole.
shubham construction
AGRAWAL ASSOCIATES
NOEL ENGINEERS
sapana enterprises
Genius Construction Co.
Chakshu Enterprise
Roy and Sons Infrastructers
NARMARAJ ELECTRICALS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .