| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹33.8 L+₹2.4 L (7.75%)Rejected-Finance SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹34.9 L+₹3.6 L (11.4%)Rejected-Finance 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹36.0 L+₹4.6 L (14.7%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹39.4 L+₹8.0 L (25.6%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L5 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
13 Jul 2021, 6:00 pmClosed
Lt Col Sidhartha Singhal
GE (P) Dappar
Repair street lights, UG cables, poles, overhead conductor, solar lights, garden lights and connected items at domestic and tech area at Mil Stn Dappar under GE (P) Dappar
2021_MES_446846_2
GE (P) DPR-11/2021-22
Open Tender
Civil Works
Works
180 days
GE (P) Dappar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (P) Dappar
₹70,000
Yes
26 Aug 2021
19 Jun 2021
15 Jul 2021
19 Jun 2021
13 Jul 2021
23 Jun 2021
19 Jun 2021 - 23 Jun 2021
Amount
Taking out old unsv cable and supply, laying, connecting and testing or passing through pipe, XLPE 1100 volts grade heavy duty underground cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire 10 sq mm 2 core normal cross sectional area complete all as specified and as directed by Engineer-in-Charge.Note : All minor spares such as cable gland, aluminium lugs etc & minor jobs such as cutting, welding etc is deemed to be included in the quoted rates.
All as per item No 1 here in before but of 4 core 16 sqmm.
All as per item No 1 here in before but of 3.5 core 25 sqmm.
All as per item No 1 here in before but of 3.5 core 35 sqmm.
All as per item No 1 here in before but of 3.5 core 50 sqmm.
All as per item No 1 here in before but of 3.5 core 70 sqmm.
Supply only street/security light bracket made out of 40mm dia light grade 1.5mtr bent to shape for fixing on any type of pole/wall with clamps nuts and bolts complete all as directed by engr-in-Charge. Make of GI pipe shall be Jindal/TATA/Swastik. Note:Cost of necessary GI items such as reducer, coupler, etc. required to be fitted with GI bracket so as to proper fittment of luminaries with bracket is deemed to be included in the quoted rate.
Supply and fix weather proof aluminum conductor 4 sqmm 2 core, flat cable for connection from looping box to street light fitting. Make :-Grandlay/Havells/Polycab.
S & F in replacenment of old unvs box Street light control junction box 280x170x130mm from cable looping box to the connector of the luminarie made out of FRP sheet and arrangement 3 phase 4 wire system with R.Y.B.& N studs and control for incoming & outgoing cables with MCB SP 10 Amps 230 volts with neutral link including flat iron 25x3 mm “D” clamps (2 Nos) suitable for mounting of box to pole /Angle of required size & shape including bolts nuts & washers complete all as specified.”NOTE: - The quoted rate is deemed to be inclusive of cost of suitable size incoming & outgoing cable glands & lugs.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of CI / GI pipes iiue in trenches and getting out in soft/loose soil complete all as specified and as directed by Engr-in-Charge .
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at level not exc 1.5 mtr above the starting point complete all as specified and as directed by Engr-in-Charge.
Returning, filling in trenches including, leveling walring and wall raming in layers not exc 25 cm in soft / loose soil, complete all as specified and as directed by Engr-in-Charge .
M&L Sand cushioning (dry sand) to underground cable for cable protection provided with layers 8cm deep before laying and 15cm after laying the cable complete all as specified and as directed.
Supply & laying un-reinforced precast concrete cable cover class LV type 1, flat size 250mm x 150mm x 40 mm complete all as specified & as directed.
Taking down old unsv fitting and supply and fix LED flood light fitting 120 watts, IP65 class with separate integral driver and with pressure dia-cast aluminium housing all as per Crompton Make, Cat Pat No JETAIRISFLS120WLED757APNBLTG or eq in Havells/Bajaj/HPL. NOTE - The quoted rate is deemed to be inclusive of cost of minor spares and misc jobs to be carried at site for fittment of luminarie.
Supply & fix power contactor 3 pole, type ML-3, with 2 NO + 2 NC aux contacts with standard coil voltage 415 volts, Rating 40 Amp as per Cat No. 90721 of M/s L & T or eqivalent in M/s Siemens/ Schneider/ABB including testing connecting commissioning complete all as specified and as directed.
Dismantling and disconnecting unsv. timer, supply, fixing and commissioning Digital type Time switch having sleek MCB shaped design with front display and DIN rail mounting, power reserve for atleast 1500 hrs, operating voltage - 240 V AC, 50 Hz, working temp. upto 55 degree celcius complete with all accessories. Make - L&T Crono, CAT No. - 67DDT0 or equivalent of makes as specified in list of makes.
M&L for application of two coats of aluminium paint on steel tubular/rail pole of 9/11/13/15 M long externally after removal of old paint, rust, dust, oil, grease or any other foreign deposits by paint removers or burning off by blow lamps, cleaning with scrapers and chemicals for removal of rust for any number of coats of any width or girth incl. numbering of poles in blackbase & white letters paint and incld. painting five no. strips upto 30 cm on bottom of pole with black and red colour paint alternately all as specified and as directed by Engr-in-Charge.
S&F LED LUMINARIE, pressure die cast aluminum housing, 70watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete all as directed and specified by Engr-in-charge. MAKE of make Havells cat part no -ENDURACITYLINERNEOSL70WLED757PASYBOTG or Equivalent in Makes as mentioned in PS of thsi tender. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate.
S&F LED LUMINARIE, pressure die cast aluminum housing, 45 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete all as directed and specified by Engr-in-charge. MAKE of make Havells cat part no - ENDURAPEARLNEOSL45WLED757PASYTOPC or Equivalent in Makes as mentioned in PS of thsi tender. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate.
S&F sheet metal enclosure distribution board suitable for MCB SPN 10 Amps, 10 kA, 'C' curve. Make - Legrand, L&T, Schenider. NOTE - The quoted rate is deemed to be inclusive of cost of minor spares and misc jobs to be carried at site for fittment of luminarie.
Dismantling and taking out steel poles/struts/PCC poles of any size incld demolition of PCC foundation complete all as specified and as directed by Engineer-in-Charge.
Supply, erection and commissioning in replacement 6 Meter high Pole (approx. dimensions - lower pipe -1.2 mtr, remaining M.S - 3.8 mtr + 1 mtr having lower section OD 114 mm and top section 76mm diameter) made out of GI pipe as per IS 1239 fitted with square Mild steel plate of dimension not less than 300mm x 300mm X 12 mm thick which should be joined with the pole at the bottom through welded joints with 4 no. circular holes of dia 20mm on 250 mm PCD suitable for M12 bolts. The pole must have a decorative casting at Bottom (approx. dimensions of - (a). Casting - height 183mm/ lower dia 172mm/ upper dia 150mm, (b). middle section casting - height 121mm/ lower dia 138mm/ upper dia 100mm). The pole shall have window cutting of size not less than 300 mm x 70 mm fitted with weather proof flush door & locking arrangement to accommodate electrical accessories (Bakelite plate and connector) for power supply connection. The window cover should be fitted with allen screws to the pole and is to be provided in bottom section of the body of the pole and shall be machined and polished properly to give it a smooth surface as per IS 2629 and IS2633. The pole shall have decorative casting at the top of the shaft. The decorative pole shall be duly pre-treated and painted UV resistant coating in approved color shade. The Pole & the cast iron embellishments should be machined & polished properly to get the smooth finish. The coating should have a DFT of not less than 80-90microns. Entire unit shall be given an extensive three Stage treatment with PU based etch primer, Zinc phosphate primer and Poly Urethane paint of approved color & prescribed for such surfaces to make it absolutely rust and corrosion proof, as well as giving it a pleasing appearance all as per Havells make Model/Cat Ref. No. - EROSPOLET0306M or equivalent in makes Bajaj/Crompton. NOTE - 1. Contractor has to get the design of the decorative pole approved from the GE (P) Dappar prior to procurement of the pole. 2. Quoted rate is deemed to be inclusive of cost of - (a). all jobs and spares required for the efficient erection and commissioning of poles, (b). spares required for connection of UG cable to the pole, (c). pole PCC foundation as specified by OEM of the pole, (d). M12 bolts - 04 Nos. as specified by OEM of the pole.
Supply and fix round single round arm bracket suitable for Pole as specified in Item no. 25 above all as per Havells Make Model - Orbit Plus S and as specified and directed by Engr -in- charge. NOTE - COst of all minor jobs and spares required for fittment of bracket on the pole is deemed to be included in the quoted rate.
Supply and fix in replacement classic look pressure die casted LED Fitting 72 Watt, IP 66, IK 07 with high performance electronic driver having operating voltage range: 140 V - 270 V with average life L70B50: 50000 built-in potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit Protection, over Voltage protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS15885 Part-2/Sec 13, PC lens to ensure better uniformity of light distribution all as per Havells Make Cat part No: EROSPT72WLED730PSYMTOPC or equivalent in Makes as specified in this tender.
Supply & Fixing of solar post top with high efficiency poly crystaline solar module of IP 65 maintaince free Lithium battery with wattage 20 W, 5700k 6-8 Hrs charging time of pole entry 57 mm dia with length of pole 5 mtrs long including all Necessary accessories of Nut Bolt and required for mounting of pole all as specified by Engr- In Charge Make : Havells Cat pat No: LHKTBVU7FA6J020 in Equivalent in Crompton /philips Note : Quoted rate is deemed to be inclusive of - (a) Cost of PCC Pole foundation. (b) Cost of Nuts an Bolts for fixing of pole to the PCC foundation. (c) Cost of minor spares required to connect the cable to the pole.
Dismantling of ACSR conductors of service feeder or distribution span complete all as specified and as directed.
Supply only aluminium conductor, steel reinforced, of size 6/1 x 2.59 mm (Weasel) straining properly on insulators with and including aluminium tape/winding wire, clamps & jumpers etc. complete all as specified. Note : 3% for sag shall be added in measurement Make : Bharat Conductor /Nicco/ALLIND.
Dismantling of unserviceable cross arms of MS Chanel/angle sections etc complete all as specified and directed.
M&L cross arms, bracing, supports, clamps and back plates fabricated from structual steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicted and inclusive of one primer coat one under coat and two finishing coat of aluminium paint complete all as specified.
Restringing and Fixing ACSR Conductor reinforced of any size to proper sag incl binding on insulator all as specified and as directed by Engr-in-Charge
Cutting & trimming of tree branches any girth and size around overhead lines to a clear distance 1.5 mtr both sides of overhead line with in a 25 to 40 mtrs span gap of HT/LT lines including clearing the complete site all as specified and as directed by the Engr-in-Charge.
M&L for stay assembly complete with accessories as shown in electric plate No.I including loop type insulator, stay clamps etc with diameter of stay 20 mm of stay rod complete all as specified & as directed. Note: - Loop type insulator, PCC foundation, Exc & earth work & GI stay strand will be measured and paid seperately under relevent items of Sch 'A'
M & L for earthing with galvanised iron earth plate of size 600x600x6mm thick buried directly in ground not less than 2.25m below normal ground level,earth plate packed on all sides with charcoal mixed with salt in alternate layers of 15 cm thickness connected by galvanised iron earth strip 32x6mm soldered & riveted toearth plate, galvanised iron earth strip will be provided by using 50mm bore galvanised iron pipe (light grade) earth plate to transformer body and neutral or test point of transformer, including flat iron clamp 25x3mm including bolts, nuts and washers complete including watering galvanised iron pipe 20 mm dia 'Light grade' 2.5mm long the earthing includes PCC pit including necessary earth works and disposal of surplus soil to a distance not less than 50m, chamber of PCC 1:4:8 type D-2 using 40mm graded stone aggregate, coping shall be of PCC 1:3:6 type C-I using 20mm graded stone aggregate, RCC pit cover 50mm thick in1:2:4 type B-I using 20mm graded stone aggregate, rein forced with 8mm dia @ 15cm c/c complete all as shown on sketch No 3 of SSR-I of 2009 and as specified and as directed by Engr-in-Charge.
S&F in repairs 6-32 A SP MCB, 10 kA 'C' series, 240 V AC, 50 Hzcomplete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
S&F in repairs 32 A TP MCB, 10 kA 'C' series, 415 V AC, 50 Hz complete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
S&F in repairs 63A TPN MCB, 10 kA 'C' series, 415 V AC, 50 Hz complete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
Supply and relplace existing u/s indicating lamp LED type suitable to operate on 230 volts AC Supply of R/Y/B colour as per site requirement all as specified and as directed.
S&F in replacement Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO or equivalent in makes as specified.
S&F in replacement Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL132010OOOO or equivalent in makes as specified.
supply and replace existing unserviceable CT as that of existing ratio and model suitable for 3 phase supply
Painting to electric control panel of E/M installations by cleaning the existing old paint with the help of mechanical tools such as wire brush, scraper and sand paper from the surface of panel and painting the prepared surface with two coat of synthatic enamel paint of approved shade over a coat of red oxide primer complete all as specified and as directed.
Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 25 to 50 sqmm, core outdoor type and taking down fault complete all as specified and as directed by Engr-in-Charge. Make : Denson/M Seal/Birla
Dismantling of unserviceable insulator any type and any size complete all as specified.
S&F in replacement Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified.
S&F Shackle Type, Porcelain, vitreous, white, brown or green insulator having working pressure 1100 Volts, height 75mm and dia 90mm including galvanised mild steel straps, washers, insulator bolts, washers and nuts complete all as specified and as directed.
M&L for erection of internally and externally hot dipped galvanized 3 MM thick steel sheet (grade S355JO) 7 Mtr long 'smart poles' of octagonal cross-section with integral camouflaged junction box for incorporating control gears with flush door with necessary locking arrangements, having base plate-220x2260x12MM to be grouted on suitable size shallow foundation with M-15 concrete with 750 MM long 04 Nos. 20MM dia. bolts and 4MM anchor plate, mounted with pole top mounting spigot type hot galvanised single arm street light mounting bracket Single arm bracket 1000 mm in length all as per instructions and technical specifications of OEM and to the complete satisfaction of Engr-in-Charge. Make-Bajaj, Cat Ref. No. - BOP-7030 or of equivalent makes specified in the list of makes.
M/s Friends Engineering Works
HARISH SALES CORPORATION
M/S Sonu Traders
SANJEEV ENTERPRISES
NAVREET CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .