Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L1 | Accepted-AOC Reasonable rate | |
| 2 | L2₹16.5 L+₹1.5 L (10.2%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L2 | Rejected-Finance Quoted amount higher than L1 | |
| 3 | Rejected-Technical 13 14 RAJA GARDEN NEAR RAJOURI GARDEN METRO STATION NEW DELHI WEST DELHI DELHI 110015 UDYAM DL 11 0014726 07AAAPA2227M1Z3 B 18AAAPA2227M1Z0 G 02AAAPA2227M1ZD M 07AAAPA2227M1Z3 R MII STATUS AS VERIFIED | WEST DELHI | DELHI | 110015 | - | Rejected-Technical Unenlisted contractor DD in lieu of tender cost and certain requisite documents has not been uploaded hard copies of documents not receive |
Tender Value
₹16.5 L
EMD Value
₹33,000
Closing Date
27 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander
HQ 137 Wks Engrs PIN 914137 Co 99 APO
PROVISION OF 125 KVA GENERATOR WITH ANCILLARIES FOR FOREIGN TRAINING NODE AT CIJW SCHOOL VAIRENGTE
2021_MES_477113_3
8587/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Vairengte
Class E
Category b i
2 documents required · 2 mandatory
₹500
GE Silchar
₹33,000
4 Mar 2022
29 Dec 2021
29 Jan 2022
29 Dec 2021
27 Jan 2022
13 Jan 2022
60 days
Amount
Supply, Install, test and commissioning of silent Diesel engine driven Generating set, AC, 415 volts, 3 phase 4 wire, 50 Hz PF 0.8 lagging, 1500 RPM of capacity 125 KVA with accoustic enclosure, Noise level dBA<75 comprising of the following and testing complete all as specified and directed.
(A) Diesel Engine : Four cylinder, liquid cooled, naturally aspirated and developing 156 BHP @ 1500 RPM, vertical engine, electric start, compression ignition, 4 stroke designed to run continiously @ 1500 RPM Confirming to IS 10002 / ISO 3046, BS:5514 standards with an overload capacity of 10% for one hour in every 12 hours operation, DG set to comply with CPCB-II norms and shall comprise of the following accessories:- (i) Radiator, Cooling system with fan. (ii) Micro fuel pump with electronic governor. (iii) Dry tube air cleaner (iv) Lubricating oil filter (spin on type) (v) 12 Volts electric starting system (vi) Battery charging alternator (vii) Stop Solenoid (viii) Lubricating oil pressure gauge. (ix) Water temperature gauge (x) Ammeter to show the reading of battery charging (xi) K cool super plus coolant (xii) First fill of Lubricating oil. (xiii) Safety shut down system for low lubricating oil, high engine temperature (xiv) Air valve and drain plug arrangement.
b. GEN-SET CONTROLLER Following indication / LCD display should be available in the digital Gen set controller (i) Lubricating oil pressure (ii) Battery voltage (iii) Engine RPM (iv) Fuel level in the day tank (v) Engine running hours indication (vi) AC Current (vii) AC Voltage (viii) AC Frequency (ix) Unit generated indicator for the items as mentioned from (vi) to (viii) (x) Suitable CTs for displaying the electrical parameters c. Safety alarm required in the digital Genset Controller:- (a) High Engine temperature (b) Low lubricating oil pressure (c) Low radiator water level (d) Low fuel level (e) Battery high voltage (f) Under / Over speed safety trips requirred in the Digital Genset Controller (g) High engine temperature (h) Low lubricating oil
(B). ALTERNATOR Alternator suitable for continious operation rated as 1500 RPM, 415 Volt, 3 phase 4 wire system, rated for output 100 KW / 125 KVA, 50 Hz, 0.8 PF in SPDP enclosure, insulation class 'H' self excited and self regulated, brushless, foot mounted in single / double bearing construction on end shields conforming to IS:4722/BS EN 60034-1 & will suitable for tropical condition. Full load efficiency of the alternator offered should be above 90%.
(D) Accoustic enclosure : The accoustic enclosure shall be designed and manufactured conforming to relevant standards suitable for outdoor installation exposed to weather conditions, and to limit noise level of <75 db (A) at a distance of 1 metre from the enclosure as per CRCB II norms insulation confirms to VL94-HF1 class for flamability. The enclosure shall be fabricated out of CRCA sheet of thickness not less than 2.0mm thick and shall be powder coated.
(E) Control Panel (i) Control panel - Overload and earth protection including all accessories such as power contractor, relays, all material equipments etc (ii) IP rating of Control Panel - IP 53
(F) Battery (i) Battery type & specification - Maintenance free confirming to IS : 14257 for high cranking performance (ii) Battery capacity (Ah) - not less than 150 (iii) Number of Battereis - 01
(G) Test Reports DG set meet requirements of Environmental (Protection) Rules 1986, in respect of noise and emission norms, as described in STC.
(H) Warranty / Installation & Commissioning (i) Warranty - 02 Years (ii) Installation and Commissioning with testing
Notes: (i) Design / Drawing / BOM of the DG set showing the dimension is to be obtained from the OEM / Authorised supplier and is to be got approved from GE before placing final order to the manufacturer. (ii) The cost of servicing including minor repairs / replacement such as topping up of coolant, engine / lubricating oil as well as lubricating filters including periodical checking of the complete DG sets for the complete defect liability period as and when required shall deemed to be included in the quoted rate. (iii) Any things missed out in the technical specification and as specified by manufacturers but technically required for efficient working of DG sets shall deemed to be included in the quoted rate. (iv) The quoted rate shall deemed to be included of first fill of engine oil and final successful acceptance test. (v) The quoted rate shall deemed to be included of 12 hours test run at site in the present of representative of Accepting Officer. All testing arrangements / equipement, resistive load including POL shall be made available by the contractor.
(vi) Cost of Foundation using PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) (below ground level 20 cm and above ground level 30 cm) or as per instruction of Manufacturer but with minimum all around space of 0.50m from the accoustic enclosure) including necessary excavation and earth work shall deemed to be included in the quoted rate. (vii) Foundation drawing as per the manufacturer's recommendation to be submitted to the GE through Engr-in-charge for approval before commencement of work.
Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 120 Sqmm 3.5 core laid in trenches or fixed to wall / pole / ceiling as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc complete all as specified and as directed. Note : Earth work, brick protection and sand cushioning and GI Pipe will be measured and paid separately under respective item.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil etc complete all as specified and as directed.
Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed .
Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed .
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to requirred thickness complete all as specified and as directed. (Note: Thickness of sand cushioning after punning down shall be measured for payment purpose)
Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of 32 x 6mm size by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion, complete all as specified and as directed. (Note: Earth strip upto a length of 7.50 m from earthplate shall be deemed to be included in quoted rate.)
kapoor and co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .