| 1 | L1₹7.0 CrAccepted-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | ₹7.0 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹7.1 Cr+₹16.0 L (2.29%)Rejected-AOC H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | ₹7.1 Cr+₹16.0 L (2.29%) | L2 | Rejected-AOC Other than lowest bidder |
| 3 | L3₹7.2 Cr+₹24.0 L (3.45%)Rejected-AOC I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹7.2 Cr+₹24.0 L (3.45%) | L3 | Rejected-AOC Other than lowest bidder |
| 4 | L4₹7.2 Cr+₹27.2 L (3.91%)Rejected-AOC 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹7.2 Cr+₹27.2 L (3.91%) | L4 | Rejected-AOC Other than lowest bidder |
| 5 | L5₹7.6 Cr+₹68.4 L (9.83%)Rejected-AOC C 33 3971 GALI NO 6 JALANDHAR CANTT 144005 | JALANDHAR | JALANDHAR | PUNJAB | 144005 | ₹7.6 Cr+₹68.4 L (9.83%) | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹7.5 Cr
EMD Value
₹7 L
Closing Date
5 Sept 2024, 6:00 pmClosed
CE Chandigarh Zone
HQ CE Chandigarh Zone N Area, Airport Road Chandigarh-160003
CE CHZ/CHM/T-05/2024-25 PROVN OF AGE E/M COMPLEX INCLUDING MRS 750 KVA AT SUBATHU UNDER GE KASAULI
2024_MES_656458_1
CECHZ/CHM-05/2024-25
Open Tender
Civil Works
Works
540 days
Subathu
Please refer Tender Documents
9 documents required · 9 mandatory
₹3,000
GE Kasauli
₹7 L
Yes
27 Nov 2024
30 May 2024
7 Sept 2024
30 May 2024
5 Sept 2024
20 Jul 2024
30 May 2024 - 8 Jun 2024
Amount
Schedule 'A'Section-I (Double Storey Building Works )
Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed structure for building (double story) AGE E/M complex including MRS as shown on drawings comprising of steel wall panel , trusses, purlins etc manufactured out of minimum 0. 75 mm thick steel sheet as per design requirements with prefabricated structure/PEB and external wall , internal walls, internal cladding, precoated galvalume Sheets 0.5mm thick pent roof with false ceiling, ramps, RCC foundation, floor finishes, RCC slab complete building as per design parameters duly approved by NIT/IIT.
Lump sum price worked out by the Contractor for "SITE CLEARANCE, DEVELOPMENT AND MISC EARTH WORK" as as listed in Sch 'A' Sec II
Lump sum price worked out by the Contractor for "INTERNAL ELECTRIFICATION WORK" as listed in Sch 'A' Sec III
Lump sum price worked out by the Contractor for "INTERNAL WATER SUPPLY WORK" as listed in Sch 'A' Sec IV
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL WORK" as listed in Sch 'A' Sec V
Lump sum price worked out by the Contractor for "ROAD, PATH CUILVERT AND HANDSTANDING WORK" as listed in Sch 'A' Sec VI
Lump sum price worked out by the Contractor for "COMPUND WALL / FENCING & GATE WORK" as listed in Sch 'A' Sec VII
Lump sum price worked out by the Contractor for "PROTECTIVE WORK" as listed in Sch 'A' Sec VIII
Lump sum price worked out by the Contractor for "AREA DRAINAGE WORK" as listed in Sch 'A' Sec IX
Lump sum price worked out by the Contractor for "EXTERNAL WATER SUPPLY WORK" as listed in Sch 'A' Sec X
Lump sum price worked out by the Contractor for "EXT ELECTRIC SUPPLY WORK" as listed in Sch 'A' Sec XI
Lump sum price worked out by the Contractor for "DEMOLITION WORKS" as listed in Sch 'A' Sec XII
Provide a provisional sum for structural steel water tank staging suitable for 1000 ltr tank
INTERNAL ELECTRIC SUPPLY WORKS:- Point wiring with PVC insulated and unsheathed cable single core multistranded FRLSH copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in and including medium grade PVC rigid non metalic conduit concealed in any type of wall should be conforming to IS-9537 with all accessories including modular cover plate, base plate and MS metal box of thickness 1.2mm as per site, 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for :-
One light/fan point controlled by one switch
One switch socket outlet 3 pin,6Amp on the independent board
One switch socket outlet 3 pin,6 Amp on same board
All as per item No. 14 above but with 2.5 sqmm ( Nominal cross sectional area ) cable with 2.5 Sqmm size copper earth continuity conductor for 3 pin 15/16 A socket outlet on independent board complete all as specified and directed.
S&F LED Bulb 7Watt complete all as specified and directed.
Supply and fix BLDC ceiling fans 5 star rated (Without Remote), complete with three blade, down rod, accessories 230V, 1200mm sweep, with BLDC motor all as specified and directed.
Supply & Fixing exhaust fan, energy efficent sturdy engineering plastic copper winding, bush bearing complete with louvers, shutters, mounting on wall, 230V, 50 Hz, 1200 RPM, 300mm sweep complete all as specified and directed.
Supply and fixing Aluminium housing LED 20 Watt batten with inbuilt Li Ion battery for power backup of 2 to 3 hrs complete
Supply and fixing wall Mounting LED fitting 10 watt, 2 ft basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver complete all as specified and directed.
S & F Bulkhead luminaire Decorative Energy saving new generation 10W LED IP65 with opal diffuser incl electronics driver & connection with copper flexible cable 3 core complete all as specified and directed.
Earthing complete with and including galvanised steel earth plate electrode 60 cmx 60cm x 6 mm thick surrounded by mixture of charcoal and salt in alternate layers, buried directly in ground vertically in a pit of depth not less than 2.25 meter deep below ground level with top as of the plate at a depth of not less than 1.5 mtrs below normal ground level connected to galvanized iron or steel earth lead wire 4.0 mm dia,( NO 8 SWG) by means of bolts ,nuts, check nuts and washers of galvanised iron or steel earth wire protected by galvanised steel pipe 15 mm bore (light grade) and connected to main switch or main control board all as shown in electrical plate No. 3 of SSR - 2009(Pt I) & including necessary excavation and earth work. The rate also include charcoal and salt in alternate layers, 20 mm bore GI pipe (Light grade ) for watering , protection pipe funnel, wire mesh , PCC 1:2:4 type B1 chamber in cement concrete ,50 mm thick precast RCC M-25 ( Normal mix) cover duly reinforced with XPM (weight not less than 3 kg /sqm ) and CI frame etc , and including provision of test point , connecting to test point and testing on completion etc, complete all as specified. NOTE : The unit rate include earthing lead and protection pipe upto 7.5 metre from top of earth plate.
INTERNAL WATER SUPPLY WORKS:- Supply and fixing for snow white vitreous china EWC single piece type 360x640x685 mm including PP Soft Close seat cover, Hinges, Dual flush cistern fittings, fixing accessories, S/P trap and riser fittings complete fixed in floor with brass screw complete all as specified and directed.
S&F 15 mm bore brass chromium plated Two way bib taps with knob to operate, complete all as specified and directed.
S&F cast copper alloy chromium plated health faucet with 1.0 mtr flexible pipe 15mm as approved complete all as specified and directed.
S&F wash hand basin vitreous china white, wall hung of size 585x450x220 mm with full pedestal including fixing accessories, SS coupling and waste pipe complete all as specified and directed.
S&F 15mm bore Brass chromium plated single lever wash hand basin pillar cock quarter turn complete all as specified and as directed.
S&F of Vitreous china urinal partition white of size 310x700 mm.
Supply and fixing CP openable type brass grating 125 mm size square or rounded etc. fixed with cement complete all as specified and as directed.
Supply and fixing 15 mm bore chromium plated fancy type brass angular stop cock with wall flanged screwed down high pressure screwed both ends for iron pipe or for unions complete all as specified and directed.
Providing, fixing, testing and commissioning of PVC Gully Trap of 300mm x 300mm size incl P/S trap clear inside with 100 mm dia outlet making excavation pit in all kinds of soil excluding soft rock and hard rock to a size of 600 x 600 mm and laying of 100 mm thick 1:4:8 mix cement concrete bed and constructing chamber with internal clear dimension of 300 x 300 mm using brick work 115 mm thick in cement mortar 1:6 up to a height of 300 mm above gully trap or up to 100 mm above paving level, plastering internal and external surface with cement mortar 1:4 to 15m thick finishing to smooth inside surface with necessary benching and channelling providing 150 x 150 mm size cast iron grating, including 40 mm thick precast RCC cover slab, clearing the surplus material, earth etc. complete. The Weight of Cover & Frame not be less than 8 kg as per standard design.
Supplying and construction of intercepting chambers of internal dimension of 450x450x600 up to 600 depth in 230mm thick brick masonry in 1:3 cement mortar, 150mm thick foundation in 1:3:6 cement concrete, haunching and benching in 1:2:4cement concrete, 20mm thick waterproof cement plastering in 1:3 to both internal and external surface finished with floating coat of neat cement, D.I. heavy duty rectangular type manhole cover and frame totally weighing not less than 75 Kg. fixed over 100mm thick RCC coping in 1:2:4 cement concrete with 10mm dia. HYSD bars at 100mm center to center both ways, curing, including backfilling , disposal of surplus earth, dewatering and water proofing of man holes, complete
S& F shall priming monoblock pumpset 1 HP (0.75 KW) single phase 220V, 50 HZ having discharge 40 LPM head 12 mtr, speed 2800 rpm pipe size 25mmx25mm complete as specified and directed by Engr-in-Charge
Providing and fixing testing and commissioning of PVC waste pipe 150 mm dia of approved make (UPVC pipes Agri pipes of 6 Kg / Sq.cm OR foam core SN-4 pipes) confirming to IS:4985 for drainage system cut to required length. Pipe to be laid below ground level in trenches upto required depth to the required slope. (for complete external under ground sewer drainage network) (SEWER )
Sewage Disposal:- RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for complete for 50 users complete all as specified
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.0 M dia X 3.0 M effective depth complete all as specified
EXTERNAL WATER SUPPLY:- M&L for cutting & making one additional connection of GI pipe 40mm dia from 80/100 mm dia existing GI water distribution line including all necessary fitting etc. Note : (i) Excavation and returning filling for making branch connection will be measured and paid under relevant items. (ii) GI clamp, fittings etc required for making branch connection are deemed to be incluled in overall cost.
Dismantling & taking out of existing MS flanged pipe heavy duty of size 150mm dia from proposed approach road for proposed AGE E/M office complex and MRS and re-laying the existing MS flanged MS pipe heavy duty of size 150mm as directed by the Enginer-in-Charge during execution of work including all necessary required fittings such as flanged, bend, Tee or other MS specials, nut bolt washer & rubber/fiber gasket 3mm thick including all necessary T&P and earth work inclusive in the unit rate. Note : Earth work for taking out existing MS pipe will be measued and paid separetaly
Supply , Laying and jointing of hot finished seamless carbon steel pipe of YST-240, grade B as per ASMT A106/IS-151239, Sch 40, nominal area size NPS 150mm, outer dia 168.30mm, with nominal wall thickness 7.1mm and weight 28.22 Kg/RM laid in trench in hard/dense soil under road, culvert, etc including all necessary fittings such as Tee, Bend, Nipple etc including nut bolt washer, rubber/fiber gasket of 3mm thickness all as specified & directed by Engineer-in-charge Note : (i) Welding works i.e flanged to be welded in plain end of pipe etc inclusive in the unit rate, nothing will be paid extra in this account. (ii) Earth work shall be measured and paid seperatly.
EXTERNAL ELECT SUPPLY:- Supplying & fixing of double walled corrugated HDPE duct pipe of 63mm outer dia (OD 63mm & ID 51mm)confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as specified and direcetd.
Supplying & fixing of double walled corrugated HDPE duct pipe of 110mm outer dia (OD 110mm & ID 96mm) confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as specified and direcetd.
Supply, installation, Testing, Commissioning of Oil Cooled, Copper wound, Step down "BIS marked & BEE star labelled " transformer of capacity 250 KVA plinth mounted outdoor type with latest feature complete with standard fitted HT 11 KV, 3 phase, LT 433 V, 3 phase, 4 wire, 50 C/S ONAN oil natural air natural, delta connection on primary HT 11 KV side and star connection on secondary LT 433V with tapping at in steps of 2.5% from -7.5 % to + 7.5 % of rated voltage on HV side and to be changed by means of hand operated off load tap changing gear including first filling of new transformer oil of dilectric strength not less than 55 KV with all fitting and accessories such as LT box with cable gland, HT box with cable gland, Silica gel, breather, Oil level indicator gauge, drain out valve (oil tank), exhaust vent, air release valve, temp gauge, cast iron wheel etc. comply with EEL 2 IS 1180 (level 2). Following items/ Accessories included in this rate therefore. The Manufacturer must have valid BIS license, BEE License, ISO Certificates and Lab must be NABL approved to ascertain genuine product quality including installation, testing and commissioning complete all as specified with following specifications :- (i) Name, rating & diagram plate (ii) Off circuit tap changing switch (iii) Earthing terminals (iv) Lifting lugs (v Oil drain valve with plug (vi) Oil filter valve with plug (vii) Conservator with oil filling hole (viii) Thermometer pocket (ix) Air release plug (x) Silica gel breather (xi) Removable inspection opening (xii) Explosion vent Notes : (1) Drawing of transformer shall be approved by the GE before placing order by contractor. (2) Pre commissioning test of transformer shall be carried out by SEI or rep of accepting officer and the unit rate quoted shall deemed to include cost of the same. (3) T & P required for testing shall be arranged by contractor with overall cost.(4) Transformer test certificate to be produced by contractor from OEM of Transformer (5) Pre dispatch inspection shall be carried out by rep of AO within quoted rate. (6)PCC platform of size 2.00m x 2.00m x 1.2m including Chainlink fancing around the plateform with steel door including locking arrangment complete for transformer all as directed by Engr-in-Charg.
Single shaded reflective sign board of size 2x1 M of high intensity reflective sheet computer cut, back ground of sky blue/green colour and white letters mounted aluminium sheet 2mm thick fixed on angle iron frame of size 40x40x6 mm and supported by angle iron 40x40x6 mm complete all as per manufacturer's instruction and as specifed. Note- Unit rate quoted shall include the cost of angle iron frame, supports, nuts and washers etc complete all as directed by Engineer-in-Charge.
M&L for GI tubing Bracket 40mm light grade1.5 mtr length, 135° bend shape including grouting/fixing 2-Nos clamps required size,including bolts for fixing street light complete.
Supply & fix FRP junction box (weather proof) of size 240 x 130 x 95 mm including single phase connector arrangement alongwith suitable clamps including MCB SP. 6 Amps 10 KA rating,fixing with flat iron clamps, nuts and bolts complete all as specified and directed. Make : Sintex or equivalent
Supplying, fixing, connecting and commissioning and testing of 11 KV, 350 MVA, 630 AMP indoor type, 01 Set of 05 VCB panel board (Comprising of 01 No incomer VCB Panel & 04 Nos outgoing VCB panels) horizontal drawout horizontal isolation floor mounting motorized panel with 230V motor mechanism & 24 V DC shunt/Close coil and other fittings & accessories including installation, testing and commissioning complete all as specified with following specifications :-
(6) Indication Lamps / Push Buttons (Incomer/outgoing) (a) R, Y, B, Indication Lamp - 03 Nos (b) Breaker ON/OFF Indicating Lamps - 02 Nos (c) Spring charging Indication Lamp - 01 No (d) Auto Trip Indication Lamp - 01 No (e) Trip Circuit Healthy Indication - 01 No (7) Miscellaneous Items (Incomer/outgoing) (a) Trip/Neutral/Close Switch - 01 No. (b) Trip Circuit Healthy Push Button - 01 No (c) Fuse/MCB for spring Charge motor - 01 No (d) Fuse/MCB for AC/DC Supply - 01 No (e) Panel space heater with thermostat - 01 No (f) Panel illumination with switch - 01 No (g) 5 Amp. 3 Pin Socket with switch - 01 No (h) Copper Bus Bar - 01 Set (j) Bus Bar (for Earthing) - 01 Set (k) Control Fuses, Ferules & Wiring - 01 Set (l) M.S. Cubical with Powder Coating - 01 Set (m) 8 Window Announciator Model No. S1-801 - 01 Set (n) Power Pack with 02 nos. 12V, 100 AH maintenance free batteries & in built charger - 01 Set for power backup (o) Suitable size MS frame rack Note : (1) Drawing & specification of VCB shall be approved by the GE before placing order by contractor. (2) Pre commissioning test of VCB shall be carried out by SEI or rep of accepting officer and the unit rate quoted shall deemed to include cost of the same. (3) T & P required for testing shall be arranged by contractor with overall cost. (4) Pre dispatch inspection shall be carried out by rep of AO within quoted rate.
Supplying, fixing, connecting and commissioning and testing of 10 steps microprocessor based Automatic Power Factor improvement static condenser (Cap banks) of capacity 125 KVAR for 250 KVA Transformer 0utdoor type panel compaly with 10 tank spray base tricationic phosphating treatment process for powder coating painted with RAL 7032 & PU foam gasket without mannual pasting,joint less suitable for 1100V grade 3 phase 50 Hz AC supply.fully compartmentalized design, floor mounted, fabricated out of 3.15mm MS Sheet ,having plinth of 100 mm front door and back opening having locking arrangement prewired with copper conductor PVC insulated cable/extension strips and connected with suitable size thimbles/lugs duly suitable chemical treatment including locking arrangement suitable for mounting, with required sheet metal enclosures, thimbles , Fan 8'' (200mm) sweep 230V AC Axial, PVC flexible Cu wire 16 Sqmm stranded red, PVC CU wire 2.5mm dia Strd Flex Blk., PVC CU wire 1.5mm dia Strd Flex Blk, CT shorting terminals, Terminal block 2.5 Sqmm all as specified and directed, and all other electric incoming and outgoing connections with PVC insulated multi stranded copper wire of suitable size and PVC flexible conduit medium quality as required, comprising of following:
(e) 15KVAR CAPACITOR BANKS FIXED TYPE (01 No): (i) MCCB 63A TP, 10KA - 01 No. (ii) 50A TP AC 3, duty contactor 240V AC coil -01 No (iii) 15 kVAR, 440V, 50 Hz, 3 Phase, Capacitor cylindrical type, Heavy duty MPP- 01 No (iv) Green with 1No + 1NC Cont, 240V, AC - 01 No (v) Red with 1No + 1NC Cont, 240V, AC - 01 No (vi) LED indicating lamp Red, 240V, AC – 01 No (vii) LED indicating lamp Green, 240V, AC – 01 No (viii) Off push button flush red- 01 No (ix) MCB,6A,SP for control- 01 No. (f) 10 KVAR CAPACITOR BANKS (03 NOs): (i) MCB 32A TP, 'C' Curve - 03 Nos. (ii) 32A TP AC 3, duty contactor, 240V AC coil -03 Nos (iii) 10 kVAR, 440V, 50 Hz, 3 Phase, Capacitor cylindrical type, Heavy duty MPP- 03 Nos (iv) Green with 1No + 1NC Cont, 240V, AC - 03 Nos (v) Red with 1No + 1NC Cont, 240V, AC - 03 Nos (vi) LED indicating lamp Red, 240V, AC - 03 Nos (vii) LED indicating lamp Green, 240V, AC - 03 Nos (viii) Off push button flush red- 03 Nos (ix) MCB, 6A, SP for control- 03 Nos (g) 5 KVAR CAPACITOR BANKS (03 NOs): (i) MCB 16A TP, 'C' Curve - 03 Nos. (ii) 25A TP AC 3, duty contactor, 240V AC coil -03 Nos (iii) 5 kVAR, 440V, 50 Hz, 3 Phase, Capacitor cylindrical type, Heavy duty MPP- 03 Nos (iv) Green with 1No + 1NC Cont, 240V, AC - 03 Nos (v) Red with 1No + 1NC Cont, 240V, AC - 03 Nos (vi) LED indicating lamp Red, 240V, AC - 03 Nos (vii) LED indicating lamp Green, 240V, AC - 03 Nos (viii) Off push button flush red- 03 Nos (ix) MCB, 6A, SP for control- 03 Nos Note : (1) Drawing of APFC Panel shall be approved by the GE before placing order by contractor. (2) Pre commissioning test of APFC Panel shall be carried out by SEI or rep of accepting officer and the unit rate quoted shall deemed to include cost of the same. (3) T & P required for testing shall be arranged by contractor with overall cost.
Supply & Fix of High Voltage Insulating Synthetic Mats with High dielectric strength for 11KV as per IS 15652, Fire Retardant, Insulation resistance minimum 100000 Mega Ohm with 5000V Megger, Good chemical properties to with Stand Load and Movement of breaker Trolleys and Associated Electrical Equipment, No adverse Effect of Acids, Alkalis to the specification Nominal Thickness of earth mat - 2.5mm Width 1 Mtr past on floor complete all as specified and directed.
Supply and spread stone aggregate of size 20 mm at transformer yard complete all as directed by Engr-in-Charge
Rolling and consolidating road formation surfaces in cutting with 8 to 12 tonne capacity power road roller, watering as necessary including filling in hollows and depressions and consolidating to the required level, gradient and camber complete all as specified and directed.
M & L for laying and compacting 150mm thick (compacted thickness) Granular Sub Base (GSB) grading as per Grading II of Table 400-1 of MoRTH specifications for Road and Bridge works, 2013 in a single layer over compacted sub grade consisting of natural sand, crushed gravel, crushed stone, crushed slag, or combination thereof as per the grading required. The materials are mechanically mixed, spread and leveling on the sub grade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 80-100 KN static weight for achieving required compaction density of at least 98 % of the Maximum Dry Density. Consolidating to required gradient and camber complete all as specified and directed with finished surface tolerances as per Table 900-1 of MoRTH specifications for Road and Bridge works, 2013 complete all as specified and directed.
Providing, Laying, compaction of Wet Mix Macadam conforming to Clause 406 of MORT&H Specifications for Road and Bridge Works (Fifth Revision) , 250 mm thick (compacted thickness,125 mm thick in two separate layers) with mechanically crushed graded stone aggregates and granular material (size range 53 mm to 0.075 mm ), grading of aggregates as per Table 400-13 of MORT&H Specifications for Road and Bridge Works (Fifth Revision) ,including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 12 tonne capacity to achieve the desired density , required gradient and camber etc., complete all as specified and directed by Engineer-in-Charge. NOTES: 1. The WMM shall be laid in two layers i.e each layer of 125 mm thick (compacted thickness). 2. For payment purpose,both layers shall be considered as one unit.
Preparation of un-surfaced water mixed macadam (WMM) surfaces by brushing with wire brushes for removing caked mud ,dust, loose material, foreign material etc., sweeping with power brooms and finally fanning the cleaned surface with air compressors to remove all loose dirt etc. and applying evenly a priming coat on un-surfaced wet mix macadam surfaces conforming to Clause 502 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), with cationic bituminous emulsion SS1 grade,confirming to IS 8887(latest edition) @ 7.5 kg per 10 sq metres using primer distributor which shall be self-propelled or towed bitumen pressure sprayer complete all as specified and directed.
Applying cationic bituminous emulsion RS1 grade,confirming to IS 8887(latest edition) @ 2.5 kg per 10 sq metres using primer distributor which shall be self-propelled or towed bitumen pressure sprayer complete all as specified and directed.
Providing and laying 30 mm thick (consolidated thickness) Bituminous Concrete (BC) layer conforming to clause 507 of MoRT&H specifications for road and bridge work (Fifth Revision) including cost of coarse aggregates, fine aggregates, filler, 5.5% binder (paving Bitumen grade VG-30) content by weight of total mix and crushed aggregates of grading 2, Anti Stripping Agent, Warm Mix Additives (quantity, quality and grade as per the approved Job Mix Formula) etc, cleaning and pre-heating of the mineral aggregate, filler & bitumen to the specific temperature, thoroughly mixing with binder of specified bitumen content, Anti Stripping Agent, Warm Mix Additives as per mix design in Hot Mix Plant of 100-120 TPH capacity, carrying the hot mixed materials by means of tipper, trucks, or any other approved and suitable arrangements, laying the hot premixed materials over the prepared surface by means of paver finisher including manual operation as and when required for proper grade, level and camber thorough rolling with power roller 8 to 12 tonnes smooth wheeled, vibratory and tandem roller with necessary hand packing and pinning to give an even surface, including running expense of all plants and machineries, inclusive of proper traffic control during laying to the satisfaction of Engineer-in-Charge, required quality control tests at required interval etc complete in all respects complete all as specified and directed.
NOTES : (i) The contractor shall quote the rate against Item considering 5.5% VG-30 bitumen content. Job mix formula as per clause No 505.3.3 of MoRT&H specifications for road and bridge work (Fifth Revision) for bituminous concrete shall be got designed from NIT/ CTL/ Govt Engg College and shall be got approved from GE in writing well before commencement of work without any financial effect to the department. Also the bitumen content shall not be less 5.4% by weight of total mix as per clause 507.2.5 of MoRT&H specifications (Fifth Revision). (ii)The cost of materials, transportation, Job mix formula from lab and testing charges for various tests as required are included in the unit rate quoted by the contractor. (iii) Cost of filler i.e rock dust, hydrated lime or cement is deemed to be included in unit rate. (iv) If qty of binder contents is less than the qty as specified in respective items of BOQ, it shall be adjusted at supply only rates of paving bitumen @ Rs 55.00 Per Kg and if qty of binder contents is more than the qty as specified in respective items of BOQ no adjustment shall be made. (v) After spreading of mix as per clause 507.4.7 of MoRT&H specifications entire surface during the operation shall be rolled with road roller 8-10 tonnes (smooth wheeled) followed with vibratory road roller of 8 -10 tonnes static weight, followed by finish rolling with 6 to 8 tonnes smoooth wheeled tandem roller as per clause No 507.4.8 of MoRT&H specifications (Fifth Revision) and the cost of the same shall be deemed to be included in the quoted rate.
Less Schedule of Credit(Minus)
R B TRADERS (BID ID -3074547)
SATISH AND CO (BID ID -3074212)
Sant Construction Co. (BID ID -3074147)
M/S Mukesh Kumar Gupta (BID ID -3087029)
M/S ANIL KUMAR (BID ID -3079963)
M/s Sagar Associates (BID ID -3073715)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .