Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹27.3 L+₹2.1 L (8.16%)Rejected-AOC 589 BC BAZAR AMBALA CANTT AMBALA | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹27.5 L+₹2.2 L (8.87%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest Bidder | |
| 4 | L4₹27.8 L+₹2.5 L (9.87%)Rejected-AOC | L4 | Rejected-AOC Other than Lowest Bidder | |
| 5 | L5₹29.8 L+₹4.5 L (17.9%)Rejected-AOC 178 A BARODIA SCHEME NEAR RAILWAY STATION NEAR RAILWAY STATION BANI PARK JAIPUR RAJASTHAN 302006 UDYAM RJ 17 0169767 | JAIPUR | RAJASTHAN | 302006 | L5 | Rejected-AOC Other than Lowest Bidder |
Tender Value
₹35.7 L
EMD Value
₹71,400
Closing Date
12 Dec 2022, 6:00 pmClosed
GE (S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
PROVN OF CERTAIN (05 NOS) SANCTION WORK ( SPECIAL REPAIR/MINOR WORKS/ REVENUE WORKS) AT JAIPUR MIL STN UNDER GE(S) JAIPUR
2022_MES_557703_2
GE (S)/J-45P /2022-23 8726/E8
Open Tender
Civil Works
Item Rate
180 days
Jaipur
Class D category b(i)
9 documents required · 9 mandatory
₹500
GE (S) Jaipur
₹71,400
Yes
9 Jan 2023
10 Nov 2022
14 Dec 2022
10 Nov 2022
12 Dec 2022
30 Nov 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc Job No :- 07/SR-151.00 Job No :- 13/SR - 348.00 Job No :- 05/REV - 244.00
M&L Point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor FRLS cable of 1100 V grade PVC insulated and unsheathed cable inclosed in and including concealed/ pvc conduit 20 mm dia medium grade with all accessories ISI marked, including MS sunken box for mounting fitting like switches, sockets fan regulators modulor type etc. including 1.5 sqmm single core PVC insulated but unsheathed copper earth continuty conductor to common earth and connected FRLS cable 1100 V grade as continuous earth wire to earth dolly for followings ;-
One light/fan/ bell point controlled by one, one way switch. Job No :- 07/SR-108.00 Job No :- 13/SR-290.00 Job No :- 05/REV - 150.00
One 3 pin 5 Amp socket outlet on same board with other switches. Job No :- 07/SR-8.00 Job No :- 13/SR-12.00 Job No :- 05/REV - 17.00
One 3 pin 5 Amp socket outlet on independent board with other switches. Job No :- 07/SR-25.00 Job No :- 13/SR-32.00 Job No :- 05/REV - 29.00
All as per Item No 2 above but with 4 Sqmm copper cable for 3 pin 15 Amps socket outlet on independent board, including 4 Sqmm copper cable continuous earth wire and connecting to common earth dolly. Job No :- 07/SR-10.00 Job No :- 13/SR-14.00
S&F switch, piano type 230/250 volts :-
(a) Single pole, one way 5 Amp rating Job No :- 07/SR-141.00 Job No :- 13/SR-334.00 Job No :- 05/REV-196.00 Job No :- 03/REV-50.00
(b) Single pole, one way 15 Amp rating Job No :- 07/SR-8.00 Job No :- 13/SR-60.00 Job No :- 05/REV-48.00
(c ) Bell push, SP 5 Amp Job No :- 07/SR-2.00 Job No :- 13/SR-12.00
Bell Ding Don AC 230 volts single pole Job No :- 07/SR-2.00 Job No :- 13/SR-12.00
S&F Socket outlet piano type 230/250 volts :-
(a) Socket outlet 05 Amp 3 Pin & 2 Pin rating Make- Anchor Cat pt No-14304 or equivalent make as per Appendix 'B'. Job No :- 07/SR-33.00 Job No :- 13/SR-44.00 Job No :- 05/REV-46.00 Job No :- 03/REV-50.00
(b) Socket outlet 2in1, 3 pin 5 /15 Amp rating Job No :- 07/SR-8.00 Job No :- 13/SR-60.00 Job No :- 05/REV-48.00
M&L Ceiling rose surface bakelite 65x50mm, three terminals. Job No :- 07/SR-80.00 Job No :- 13/SR-200.00 Job No :- 05/REV-150.00
Taking down exhaust fan/celing fan of any type and capacity and refixing the same after minor repair oiling and geasing etc all as specified and dirted by EIC Job No :- 07/SR - 20 Job No :- 13/SR- 44.00
Supply & fix in replacement LED retrofit lamp ( size-4 feet), Regal Batten for LED tube, universal batten for T5 lamps surface/wall mounting IP 20 with twin core twisted flexible copper conductor cable with suitable size. Make - Havells cat No - REGALBATTENT5UPTO1X18WDSBSWH Or equivelent cat part in other makes as per Appendix 'B'. Job No :- 07/SR-78.00 Job No :- 13/SR-136.00
Supply & fixing in replacement Mirror surface mounted LED fitting 14 W (2 Feet)provided with a high output PMMA diffuser for glare free light , IP 20 with high brightness LEDs complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size. Make - Crompton cat pt No- LCL-14-CDL or equivelent cat part in other makes as per Appendix 'B'. Job No :- 07/SR-8.00 Job No :- 13/SR-12.00
S&F in repair factory made, sheet distribution boards, SP&N 8 ways, double door protection class IP-42 double door type suitable for mounting MCB/ MCCB, confirming to IS-13032, IS-8623, BS-5484 with minimum 200 amps, copper bus bar complete. Job No :- 07/SR - 4 Job No ;- 05/REV - 5
S&F in repair factory made, sheet distribution boards, TP&N 4 ways, double door protection class IP-42 double door type suitable for mounting MCB/ MCCB, confirming to IS-13032, IS-8623, BS-5484 with minimum 200 amps, copper bus bar complete. Job No :- 07/SR- 1 Job No ;- 05/REV - 1
S&Fin repair MCB 10 KA confirming to IS-8828 : 1996, IEC-898 : 1995 rupturing capacity of the under mentioned type and rating :-
(a) SP 5 to 32 amps Job No :- 07/SR-24.00 Job No :- 13/SR-100.00 Job No ;- 05/REV - 90
(b) SPN above 32 to 63 amps. Job No :- 07/SR-4.00 Job No :- 13/SR-10.00 Job No ;- 05/REV - 9
(c ) TPN 63 amps Job No :- 07/SR- 1.00
M & L Sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn through in and including PVC rigid conduit and conduit accessories fixed on surface/wall celing etc including provision of 1 run of 4 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity including taking down existing submain any size complete. Note: (i) Cost of hole in wall for any purpose to provide connection in Panel/DBs as per site requirement will be inclusive in unit quoted Rate. (ii) 2 run of 6 sqmm + one run of 4 sqmm earth and 1 RM conduit will be measured one unit. Job No :- 07/SR-90.00 Job No :- 13/SR-220.00 Job No ;- 05/REV - 208
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm burried directly in ground (earth pit not less than 2.25 meters deep below normal ground level ), with top edge of the plate not less than 1.5 mtrs below normal ground level , connected to and including galvanised earth strip 25X 4 mm by means of galvanised iron bolts , nut and washers and connected to other end to main panel board duly protected by galvanised iron pipe 25 mm dia " light grage " earth plate surrounded by packed layer of coat dust and common salt 15 cm thick all around bottom and top watering pipe 20 mm bore of galvanised iron " medium grade " with funnel all as shown on electrical plate No 5 of SSR part -I and connecting to earthing testing on completion including cast iron cover frane and PCC 1:3:6 type C-2 using 20 mm grade stone aggregate as in earthing pit with cast iron cover and frame including necessary earth work etc complete all as per specified and directed by Engr-in-Charge including taking down complete. Note 1- Following items deemed to be included in quoted rate (a) Earth electrode (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 meter (c) Material and labour for connecting earth electrode and earthing lead as specified (d) Adequate quantity of charcoal dust and common salt as per direction (e) All labour involved including testing of earth network.(f) Excavation and earth work or drilling holes for electrode (g) P.C.C pit and C.I cover (h) Funnel with watering pipe, wire mesh and copper lugs etc as specified (j) G.I. protection pipe pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. Job No :- 07/SR- 5.00 Job No :- 13/SR- 10.00 Job No :- 05/REV- 10.00
Supply and fixing of single pole and neutral enclosure with a two pin and a earth plug and socket complete with one single pole MCB of 20 Amps 240 volt Job No :- 07/SR-2.00 Job No :- 13/SR-4.00.
Supply and fixing in repair of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc Job No :- 13/SR
Supply & fixing lamp holder PVC body complete all as specified and directed with 01xLED bulb 9 watt Job No :- 13/SR
Supply & fix in reapir Exhaust fan steel body AC single phase 230 V of size 450mm sweep heavy duty with blades and frame and louvers all as specified and directed including taking down existing u/s exhaust fan. Note :- Old u/s exhaust fan will be deposited to MES (E/M) store yard. Job No :- 13/SR
S&F in repair factory made, sheet distribution boards, SP&N 12 ways, double door protection class IP-42 double door type suitable for mounting MCB/ MCCB, confirming to IS-13032, IS-8623, BS-5484 with minimum 200 amps, copper bus bar complete. Job No :- 13/SR - 10 Job No ;- 05/REV - 4
Supply and Fixing in replacement security lights LED 45 W Energy saving & Environmental friendly long life versatile pressure die cast aluminium IP 66 LED Wall mounted Light Luminaries are made of die casted aluminium body and toughened glass cover for uniformlight spread cames LED technology of Britelite. including bracket made out of suitable size of GI medium grade tubing and fixed with clamps nuts and bolts, washer complete all as specified . Make- CG cat Pt No-LSTP-45-CDL Or equivelent cat part in other makes as per Appendix 'B'. Job No :- 13/SR
Taking down US geyser(water heater) of any type and capacity and refixing/deposited to MES store all as specifed and directed by EIC under item here in after. Job No :- 13/SR
Refixng the serviceable geyser obtained srl item No 24.00 above after minor repair on site & testing trouble free functioning complete. Job No :- 13/SR
suplly and fixing electric water heater storage type stainless steel body with copper inner tank and heating element upto 2 KW capacity 25 litre BEE 5 star rate complete with all accessories such as safety valve thrmostate NRV connection pipe etc. Note :- Old u/s geyser will be deposited to MES (E/M) store yard. Job No :- 13/SR
M & L for Supplying, laying, connecting and testing in trenches, under floors/ roads or on walls Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armored, electric power cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade, of size 10 sqmm, 2 core including taking down complete. Job No :- 13/SR
Supply installing testing & commissioning of factory assembled diesel engine driven AC DG set to give an output of 15 KVA 20.5 BHP KW continuosly rating at a PF of 0.8 lagging 415 volt AC 3 phase 4 wire 50 HZ 1500 RPM directly coupled with diesel engine water cooled mounted on common base frame complete with floorgenerating set fully wired alternatortalling, testing & installation of silent diesel engine driven generating set 415 volts, 3 phase 4 wire engine as per IS : 10001/1 mounting fuel tak (service tank) of adequate capacity with fix other accessories etc line & accessories PCC foundation work as per manufacturers instructions vibration damper pads & other ac four storke electric start Diesel enginer conforming to BS accessories etc comprises the following as specified in particular specification. Make - Kirloskar MODEL HA 294 or equivelent cat part in other makes as per Appendix 'B'. (i) Diesel Engine (ii) Alternator (iii) Accustic Enclosures (iv) Base frame (v) Batteries Job No :- 01/MIN
M & L for Supplying, laying, connecting and testing in trenches, under floors/ roads or on walls Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armored, electric power cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade, of size 16 sqmm, 4 core . Job No :- 01/MIN
Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes, laying cables errection of poles / struts/stays etc n.exe 10 Sqm on plan not exceeding 1.5 metre in depth and getting out in any type of soil. Job No :- 13/SR-61.00 Job No :- 03/REV-28.00 Job No :- 01/MIN - 7.00
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in any type of soil. Job No :- 13/SR-45.00 Job No :- 03/REV-26.00 Job No :- 01/MIN - 5.00
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point. Job No :- 13/SR-16.00 Job No :- 03/REV-2.00 Job No :- 01/MIN - 2.00
M & L Sand cushioning to PVC under ground cable with screened and washed sand and jently punning down to provide a required cover. Job No :- 13/SR- 29.16 Job No :- 01/MIN - 4.75
M&L bricks for protection cover to under ground cable (with old size sub class `B` bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm as directed by Engineer in-charge Job No :- 13/SR- 2.80 Job No :- 01/MIN - 0.50
All as per Item No 2 above but with 2.5 Sqmm copper cable for 3 pin 15 Amps socket outlet on independent board, including 1.5 Sqmm copper cable continuous earth wire and connecting to common earth dolly. Job No :- 05/REV
All as per Item No 2 above but with 4 Sqmm copper cable for 3 pin 15 Amps socket outlet on independent board, including 2.5 Sqmm copper cable continuous earth wire and connecting to common earth dolly. Job No :- 05/REV
S&F in replacement LED flood light 60 watt 230 V AC Outdoor type with thermal nmanagement in multiple optics and equipped with IP 66 protection with impact aand correoison resitant complete with driver and lamp with necessary 3 core wre connection, Bracket mounting with all accessories pre-wired twin core twisted flexible copper conductor cable all as specified and directed by EIC Job No :- 05/REV
Supply & fix in replacement BATTEN, LED Light fittings 1 x 20 W ,240 volt( size-4 feet/1136 mm) long life, surface/wall mounting IP 20, luminaire per watt (Minium) extruded alluminium housing with frosted PMMA diffuser with high brightness LEDs complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size. Make - Syska CAT part No SSK-ALB-20W or equivelent cat part in other makes as per Appendix 'B'. Job No :- 05/REV
M&L for Sub main wiring with four runs of 10 Sqmm single core FRLS PVC insulated but in unsheathed multi stranded copper conductor cable 1100 volts grade drawn through and including of 25mm dia PVC rigid conduit medium with conduit accessories and fixed to the surface of wall/ceiling as per ISI including 2x 6.0 Sqmm PVC insulated copper conductor earth continuity wire including taking down of existing submain of any size. Note: (i) Cost of hole in wall for any purpose to provide connection in Panel/DBs as per site requirement will be inclusive in unit quoted Rate (ii) 4 run of 10 sqmm + 2 run of 6 sqmm earth and 1 RM conduit will be measured one unit. Job No :- 05/REV
S&F in reapir MCCB 100 amp 16 KA four pole compete all as specified and directed Job No :- 05/REV
Supply and Fixing in replacement LED street light fitting 45 watt 230 volt AC outdoor type with hihg pressure die cast aluminium hosing and heat resistant complete with driver lamp bracket with impact and corrision resistant including thermal management in multiple optics complete with IP 65/66 protection complete bracket made out of suitable size of GI medium grade tubing and fixed with clamps nuts and bolts, washer complete all as specified . Job No :- 05/REV
Supply & fix Air Circulator fans 230 volts single phase oscillating 750 mm sweep suitable for wall mounting star rating 5 BEE. Heavy duty all as specified and directed by engr-in-charge Job No :- 05/REV
Supply/fabrication & fixing of cooler stand made of 40mm x 40mm x 5mm MS angle iron including grouting in wall including two coat of synthetic enamalled paint over a coat of red oxide as directed by Engr-in- charge Note : (i). Drawing of MS stand shall be got approved by Engr-in-charge before fabrication Job No :- 03/REV
Supply, installed, commissioning & testing Desert Cooler electric driven (single phase)having copper winding exhaust fan type of 500mm sweep fan motor with 4 leaf heavy duty blade 1400 RPM and power consumption of 350 Watts, nominal airflow capacity of 6000cum per hour including PVC submersible pump copper winding complete single phase 230 volts , ISI marked Galvanized non corrosive steel body(minimum 20 gauge) and body dimension (1150mm X750mmX750mm) ,front grill rectangular shape and three side with opening steel shutter(size 750mmX 600mm ) with wooden chips pad and water storage tank capacity 90 ltr and three step rotary type controller including PVC pipe fitting , including PVC float valve 15 mm size with ON/OFF switch 1.5 meter connecting copper conductor 3 core lead with 3 pin outlet 5 amp and all as specified and directed by Engr-in -charge. Job No :- 03/REV
M&L Point wiring complete with PVC insulated and unsheathed cable 1.5 sq mm (nominal area) ISI marked ,FRLS,multi-stranded copper conductor single core including ISI marked PVC casing and capping with fittings and accessories fixed to wall / ceiling by means of PVC rowl plugs fastener with screws including hard wood board with top cover 3mm thick of plastic laminated sheets of required colour , and including 1.5 Sqmm PVC insulated and unsheathed FRLS,stranded copper wire conductor cable to common earth and connecting to earth dolly including colour coding of cable shall be Phase - Red, Neutral- Black and Earth- Green complete. Job No :- 03/REV
M&L for gun metal gate valve with iron wheel head, screwed both ends for jointing iron pipes, non rising, forged brass spindle class-1, ISI marked of following sizes.
(a) 15mm dia Job No :- 03/REV
(b) 20mm dia Job No :- 03/REV
M&L for tubes " medium grade " galvanised steel (GI) ISI marked with all fittings and fixed complete to walls and celling or laid in floors / trenches of the folowing sizes :
(a) 15 mm bore of pipe Job No :- 03/REV
(b) 20mm bore of pipe Job No :- 03/REV
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm burried directly in ground (earth pit not less than 2.25 meters deep below normal ground level ), with top edge of the plate not less than 1.5 mtrs below normal ground level , connected to and including galvanised earth strip 25X 4 mm by means of galvanised iron bolts , nut and washers and connected to other end to main panel board duly protected by galvanised iron pipe 25 mm dia " light grage " earth plate surrounded by packed layer of coat dust and common salt 15 cm thick all around bottom and top watering pipe 20 mm bore of galvanised iron " medium grade " with funnel all as shown on electrical plate No 5 of SSR part -I and connecting to earthing testing on completion including cast iron cover frane and PCC 1:3:6 type C-2 using 20 mm grade stone aggregate as in earthing pit with cast iron cover and frame including necessary earth work etc complete all as per specified and directed by Engr-in-Charge complete. Note 1- Following items deemed to be included in quoted rate (a) Earth electrode (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 meter (c) Material and labour for connecting earth electrode and earthing lead as specified (d) Adequate quantity of charcoal dust and common salt as per direction (e) All labour involved including testing of earth network.(f) Excavation and earth work or drilling holes for electrode (g) P.C.C pit and C.I cover (h) Funnel with watering pipe, wire mesh and copper lugs etc as specified (j) G.I. protection pipe pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. Job No :- 01/MIN - 4.00
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. Job No :- 07/SR
M&L 15 mm thick plaster in CM 1:6 on fair faces of brick walls or concrete surface, surface finished even and fair without using extra cement. Job No :- 07/SR
M&L 15 mm thick plaster in CM 1:4 on stone masonry surfaces or surface other than fair face of brick work of walls, finished even and fair without using extra cement. Job No :- 07/SR
M&L 5 mm thick plaster in CM 1:3 on ceiling surfaces or concrete surfaces finished even and fair without using extra cement. Job No :- 07/SR
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper of approved shade/tint over 1 mm thick wall care putty on walls all as specified & directed by Engineer-in-charge. Job No :- 07/SR
M&L for preparation of new plastered surfaces of ceiling & applying three coats of white wash. Job No :- 07/SR
M&L for preparation of new plastered surfaces on wall & applying two coats of weather based paint (exterior weather coat) all as specified & directed by Engr-in-Charge. Job No :- 07/SR
VARDHMAN SALES CORPORATION
SHREE BHAGWATI ENTERPRISES
LAKSHMI ASSOCIATES
M/s Bhavesh Construction Company
M/S TRADE LINKERS
M/s Radhey Enterprises
Shree Karni Electrovision
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .