Loading…
Loading…
Tender Value
₹5.1 Cr
EMD Value
₹4.0 L
Closing Date
20 Feb 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
S AND T
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or " V" whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
The tenderer must have successfully completed any of the following during last 07(seven) years, ending last day of month previous to the one in which tender is invited: Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Similar Nature of Work for this tender is " Any work of Signal or Telecom involving trenching, laying and testing of signaling or telecom cables.
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Sch A-Replacement of defective & Overaged Quad cable in BDC-TBAE, BWN-SKG, KAN-TIT, BWN-BGNA, DKAE & BLY in HWH Divi. Sch B-Laying of 2 x 48 Fibre OFC cable in Bandel-Tribeni, Barddhaman-Saktigarh, Khana-Talit, Barddhaman-Balgona in HWH Divi".
SDSTE-ETN-6Q-BDC-TBAE-25
SDSTE-ETN-6Q-BDC-TBAE-25
Open
Works - General
9 Months
Howrah, West Bengal
₹0
₹4.0 L
20 Feb 2026
27 Jan 2026
108 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 4,23,78,686.35 | ||
| — | — | — | 2,00,52,737.94 | ||
| "Supply of 6 QUAD UNDERGROUND JELLY FILLED QUAD CABLE FOR SIGNALLING AND TELECOM INSTALLATION SIZE:6QUAD X 0.9 MM DIA AS PER RDSO SPECIFICATION NO-IRS:TC- 30/2005(VER.1) WITH AMENDMENT NO.5 OR LATEST AMENDMENT INSPECTION : RDSO." | — | 57.00 | — | — | |
| — | — | — | 51,443.1 | ||
| "Supply 20 Pair CT box (Cable termination box Spec. No. IRS-TC/18-75 or latest. ) INSPECTION : CONSIGNEE." | — | 30.00 | — | — | |
| — | — | — | 25,731 | ||
| "Fixing of Outdoor cable termination box or termination of outdoor PIJF/QD cable installation portion including fixing of 20 Pair CT box on wall /inside location box termination of cable in CT box & sealing cable termination box Spec. No. IRS-TC/18-75 or latest. INSPECTION : CONSIGNEE. Execution " | — | 20.00 | — | — | |
| — | — | — | 61,15,200 | ||
| "Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4"" of 1:2:4 concreting should be done. (b-1)Payment will be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. " | — | 24960.00 | — | — | |
| — | — | — | 7,92,300 | ||
| Supply, transportation at site and installation of RCC cable route marker engraved and painted on both side along the route at every 30 meter and at route diversion. The cable route marker is to be fabricated as per drawing No S.I. S&T /1/2024. The fixing work is to be done as per extent practice of E.Rly and as per Railway site supervisor. INSPECTION : RDSO. | — | 1900.00 | — | — | |
| — | — | — | 2,85,000 | ||
| Laying of Signalling/Telecom /Power / Quad/ OFC cable of different size through DWC/GI/HDPE pipe in the Trench with protective work as per instruction of site engineer as per railway practice, it includes fixing of cable on wall with suitable clamps(the clamps and screws should be made of Stainless steel). All the fixing materials including Coller, bend, junction etc. shall be supplied by the contractor. (Cable shall be transported from store to site by the contractor). | — | 57000.00 | — | — | |
| — | — | — | 1,27,488 | ||
| REPAIRING OF PUCCA ROAD TO ORIGINAL STATE IN L.C.GATE AREA AFTER CABLE LAYING. | — | 498.00 | — | — | |
| — | — | — | 1,24,390 | ||
| "Cutting of concrete platform to a depth of 200 mm and width of 100 mm to lay DATA/POWER/Telecom cable through DWC Pipe of 63/50 mm dia. Contractor has to redress the cutting place into its original position without destroying the beauty after cable laying. This includes supply of DWC pipe of 63/50 mm dia. of IS: 14930 Pt-II mark. " | — | 500.00 | — | — | |
| — | — | — | 1,55,135 | ||
| Supply of Thermoshrink Jointing kits for underground 0.9MM dia conductor 4/6 Quad cable as per RDSO spec. No IRS :TC/77-2012, Rev.3 with Amd no 1 & 2 or latest. Inspection by authorised representative of Sr. DSTE/HWH. Note: material to be made available just before execution so that the life does not expire before use. INSPECTION : CONSIGNEE. | — | 71.00 | — | — | |
| — | — | — | 58,316 | ||
| Jointing (Straight through or derivation joint) of 4/6 Quad Cable | — | 61.00 | — | — | |
| — | — | — | 1,98,500 | ||
| "Supply of DWC pipe along with Socket/Coupler Conforming to IS:14930, Part-II (Earlier BSEN-50086-1 BSEN-50086-2-4) for protection of Underground/ Communication / Signaling / OFC cable. The Pipe to be of 63MM outer dia 50MM inner dia. The pipe to be of ISI Marked with non- flame propagating, anti rodent properties and have IP 67 protection on coupling arrangement to be supplied at 6mtr length. INSPECTION CONSIGNEE." | — | 500.00 | — | — | |
| — | — | — | 15,500 | ||
| Placing of DWC HDPE /RCC/GI pipes along with collars in trenches at places near track and road, crossings, platform cuttings etc. | — | 500.00 | — | — | |
| — | — | — | 8,48,640 | ||
| Supply of G.I. pipe with iron clamps on bridge / culverts / track crossing etc. for cable laying jointing with threaded collers of 80 mm normal bore Spec. No. IS:1239 medium grade. INSPECTION-RITES. | — | 800.00 | — | — | |
| — | — | — | 60,720 | ||
| Installation for G.I. pipe & collers (Spec. No. IS:1239 medium grade), in Track Crossing bridge, and any other place as advice by sectional supervisor. ( This includes installation of GI pipe dismantled from Bridge) . | — | 800.00 | — | — | |
| — | — | — | 2,08,010 | ||
| Supply of 4W way station DTMF equipment as per RDSO spec. no IRS-TC@47<47@93 or latest ( with 4 wire telephone as per spec. No IRS-TC@45&47@97 or latest. Make- Bentron, Epsilon or similar and supply of 12V/7AH power supply unit for control phone. Inspection by Consignee | — | 31.00 | — | — | |
| — | — | — | 38,967 | ||
| Installation of 4W way station DTMF equipment as per RDSO spec. no IRS- TC@47<47@93 or latest ( with 4 wire telephone as per spec. No IRS-TC@45&47@97 or latest. Make- Bentron, Epsilon or similar and supply of 12V/7AH power supply unit for control phone. | — | 31.00 | — | — | |
| — | — | — | 6,11,225 | ||
| Supply and installation of lightning and surge protection device both Class 'B' & Class 'C' between line and neutral and neutral & earth of approved type. INSPECTION-RITES. | — | 25.00 | — | — | |
| — | — | — | 38,796 | ||
| "Supply of V.F. transformer 1220:600/470 /:1220 as per IRS:TC-22/ 76 or latest. Inspection - consignee " | — | 53.00 | — | — | |
| — | — | — | 22,790 | ||
| "Installation of V.F. transformer 1220:600/470 /:1220 as per IRS:TC-22/ 76 or latest. Inspection:- consignee " | — | 53.00 | — | — | |
| — | — | — | 1,04,720 | ||
| "Supply of earth electrode mild steel galvanized, light class, IS:1239(PART-I)- 1979.earth electrode pipe should be with 3 mm thick, 50 mm dia and perforated(staggered),5 mm dia holes, 2 nos per 305 mm length with clamp of MS FLAT (galvanized) of size 35 mm x 6 mm (SPEC.NO.226 STD). Earth pipe should include CI threaded cap. Materials to be procured and designed as per Drg No. SI/TYP/0097 dated 25.03.25. INSPECTION CONSIGNEE." | — | 70.00 | — | — | |
| — | — | — | 63,770 | ||
| "Supply of MS FLAT (SPEC. NO. 226 STD or latest) of size 35 mm x 6 mm with length 5 mtr with holes of 12 mm dia at both ends as per CSTE/ER'S Drg No. SI/TYP/0097 dated 25.03.25.Inspection: by Consignee." | — | 70.00 | — | — | |
| — | — | — | 81,270 | ||
| "Fixing of earth electrode including laying and installation of MS flat of size 35 mm x 6 mm with length 5 mtr or as per extant practice of Eastern Railway. As per CSTE/ER'S Drg No. SI/TYP/0097 dated 25.03.25 for apparatus cases, signal post & other equipment as per instruction of site engineer. Provision for fixing MS flat at apparatus cases/ signal post/other equipment should be made by the firm at site. Full threaded bolts of 10 mm dia and length 40 mm should be welded in the apparatus cases in such way that the MS flat at apparatus case end can be fixed from outside or from inside. Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. All hardware and other miscellaneous materials required for installation to be supplied by the contractor except earth electrodes and MS flat. Note: -all materials required to be arranged by the contractor except 2 core cable will be supplied by the railway. (This includes provision of equipotential earth by connection the adjacent exsisting earth by desire G.I./ copper tape/cable. " | — | 70.00 | — | — | |
| — | — | — | 39,970 | ||
| "Provision of cement concrete enclosure for earth electrodes as per DRG. NO. S&T/C36(NKG). This includes supply of all materials by the contractor duly inspected by consignee. " | — | 70.00 | — | — | |
| — | — | — | 17,864 | ||
| "LOADING, UN-LOADING & TRANSPORTATION OF MATERIALS INCLUDING CABLES, LOCATION BOXES AND MISCELLANEOUS ITEMS REQUIRED FROM VARIOUS PLACES IN 9MT TRUCK TO THE RAILWAY STORES AS PER SITE ENGINEER. (i) TRANSPORTATION OF MATERIALS" | — | 350.00 | — | — | |
| — | — | — | 28,473.62 | ||
| "LOADING, UN-LOADING & TRANSPORTATION OF MATERIALS INCLUDING CABLES, LOCATION BOXES AND MISCELLANEOUS ITEMS REQUIRED FROM VARIOUS PLACES IN 9MT TRUCK TO THE RAILWAY STORES AS PER SITE ENGINEER. (ii) Loading and Unloading " | — | 14.00 | — | — | |
| — | — | — | 6,51,163 | ||
| — | 185.00 | — | — | ||
| — | : - "Disconnection Day to | & Reconnection other telecom works. assist Telecoml Supervisor | Equipments Labours(Helper/Assistant) Other S&T | ||
| — | — | — | 16,343 | ||
| "Supply of SITEL PRIMARY Cell (Dry, Leclanche) - 1.5 V shall not be less than 45 AH as per Specification IRS:S- 95/96 Amd. - 1. INSPECTION CONSIGNEE." | — | 25.00 | — | — | |
| — | — | — | 3,93,000 | ||
| "Supply of half size apparatus case (As per as per RDSO drawing No. RDSO/S-11507). This includes supply of location box (GKP type) with 'E' type lock & key, fitted on location door on both side, E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11507. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee subject to procurement from RECOMMENDED LIST OF FIRMS FOR MECHANICAL SIGNALLING ITEMS if value of whole item in work less than 5 lakhs or as per extant policy.INSPECTION CONSIGNEE." | — | 50.00 | — | — | |
| — | — | — | 1,55,250 | ||
| "Casting, concreting and curing of concrete foundation (in ratio 1:3:6), erection and installation of half size apparatus case (GKP type) Apparatus Case as per DRG.NO. RE/S&T/SIG/TENDER /SK/8/85 with 'E' type lock on CC foundation. This includes cost of all materials required for fixing holding down bolts, casting, concreting. Note: - bolts, nuts and washers, bitumen compound to be supplied by contractor and bitumen compound to be used in between apparatus case and foundation as per site engineer. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. Note: - Location boxes to painted with anti-corrosive paints as per IS: - 9862-1981, one and half feet from the bottom, on all surfaces-both inside and outside. Inspection: Consignee" | — | 50.00 | — | — | |
| — | — | — | 22,500 | ||
| Supply of hard wood shelves thickness 25 mm for keeping equipment's and batteries in the location box (FULL or HALF GKP /other type) with suitable varnish and anti-termite chemicals fitted on angles with nuts & bolts. Inspection: -Consignee (notebalance quantity may be taken from Rly store if available). 450 x 400 x 25 MM for half size location box. INSPECTION CONSIGNEE. | — | 50.00 | — | — | |
| — | — | — | 90,20,000 | ||
| Transportation of HDT machine with accessories including handling of stores materials, preparation of sites and boring for placing of 110 mm dia HDPE PIPE for crossing of S&T cables together a bridges/culverts, pucca road/crossing, boring trench shall be minimum 3 (three) meter below the river bed and 1(one) meter below the track/road/pucca road crossing area. This includes supply of accessories for HDPE pipes, including, cost of fuel and all other items etc.which will be required for laying of cable through it. The work shall be executed as per instruction of site engineer. HDPE PIPE TO BE SUPPLIED AS PER RDSO SPEC. Contactor shall provide all material required for boring and adequate nos. of labors for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.Boring up to the length of 150 meters. (A) Preparation of site for Horizontal Boring shall be carried out in presence of Railway Representative. | — | 5000.00 | — | — | |
| — | — | — | 40,000 | ||
| Transportation of HDT machine with accessories including handling of stores materials, preparation of sites and boring for placing of 110 mm dia HDPE PIPE for crossing of S&T cables together a bridges/culverts, pucca road/crossing, boring trench shall be minimum 3 (three) meter below the river bed and 1(one) meter below the track/road/pucca road crossing area. This includes supply of accessories for HDPE pipes, including, cost of fuel and all other items etc.which will be required for laying of cable through it. The work shall be executed as per instruction of site engineer. HDPE PIPE TO BE SUPPLIED AS PER RDSO SPEC. Contactor shall provide all material required for boring and adequate nos. of labors for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. (B) Laying of 6 quad/Signalling cable/Power Cable with nylon rope through 110 mm HDPE pipe and back filling of boring pit. | — | 5000.00 | — | — | |
| — | — | — | 3,00,560 | ||
| "Supply, installation and complete indoor wiring of 19 inch (42U) covered Rack of size 2035 mm x 600 mm x 600 mm (Approx.). The rack shall be complete with all fittings for housing SDH equipment, Primary MUXES, DDF, MDF using crone modules and other equipment like runway ladders etc. completely wired and equipped with integrated protection modules for all channels as per technical specifications and other stipulations of tender document. It should be possible to lock all the equipment with only order wire telephone remaining outside the rack. Inspection: Consignee." | — | 8.00 | — | — | |
| — | — | — | 35,750 | ||
| "Supply of Disconnect Terminal Block, screw less type, 4-wire front entry (Two in-put & Two out-put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3).INSPECTION: CONSIGNEE." | — | 650.00 | — | — | |
| — | — | — | 2,200 | ||
| Supply of End plate 2.5mm/0.091 in thick as per site requirement.INSPECTION CONSIGNEE. | — | 220.00 | — | — | |
| — | — | — | 2,200 | ||
| "Supply of End Stopper 10mm/0.0394 in width as per site requirement.INSPECTION CONSIGNEE." | — | 220.00 | — | — | |
| — | — | — | 5,450 | ||
| "Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement.INSPECTION: CONSIGNEE." | — | 50.00 | — | — | |
| — | — | — | 11,200 | ||
| "Supply of Markers strip. INSPECTION: CONSIGNEE." | — | 700.00 | — | — | |
| — | — | — | 1,61,100 | ||
| "Supply of hylam sheet 12mm . Inspection: consignee" | — | 30.00 | — | — | |
| — | — | — | 8,060 | ||
| Excavation of Track Crossing,road Crossing (Earth Work and Re-instatement of Track after laying of GI pipe or same) as per direction of site supervisor. | — | 500.00 | — | — | |
| — | — | — | 21,616.95 | ||
| Supply and installation of Wall mounted 19",6U foldable Rack with fan and 6 no sockets and accessories. Make: HCL, VALRACK & APW or Similar. INSPECTION : CONSIGNEE. | — | 5.00 | — | — | |
| — | — | — | 77,405.7 | ||
| "Supply of Emergency socket Box of FRP Material approved type complete with 6 pin way female pin as per RDSO Spec. No. RDSO/SPN/TC/44/2002 Ver. 2 Amd 3 or latest amendment.INSPECTION CONSIGNEE." | — | 30.00 | — | — | |
| — | — | — | 1,97,996.04 | ||
| Supply and installation of 4 port Lan extender as per Tech Spec. IP configured Make DAX/ NOMUS or Similar. Support speed up to 2MBPS FOR DISTANCE UP TO 5 KM OF 0.50 mm Dia Single pair cable, should operate in Half/Full duplex Mode with min 4 Nos of 10/100 Base T, ethernet (IEEE PO 2.3 COMPLIENCE), Support RJ -11 for connecting copper cable,support RJ 45 for connecting ethernet port,protection against lightning & accidental power cable pair, configured through console, Telenet of HTTP (WAVE BROUSER), visual indication to know LINK, ETHERNET & POWER; POWER SUPPORT 230V AC ± 10% & 50HZ;TEMP RANGE 0 TO 45 DEGREE. INSPECTION : CONSIGNEE. | — | 6.00 | — | — | |
| — | — | — | 5,97,232 | ||
| "Supply of 2 MB Programmable Primary Digital drop insert multiplexer as per RDSO Specs. IRS TC- 68/2004 (Amnd.1) or latest with conference facility and other stipulation to tender documents and fully wired for 30 channels complete with power supply card, remote control, supervision facility and all other accessories, installation material, manuals etc. It should have facilities to accommodate data interface card in multi drop mode and should be able to support cards needed for video conferencing and ISDN. It shall support NMS installed at Test Room and may operate local/remote location of entire section. It also includes submission of all technical documents, manuals and supply of all miscellaneous items which will be required for final testing and commissioning of system. The above MUX should be equipped with following circuits: No. 49.00 1,49,308.00 - i) 2 wire/ 4 wire E&M VF circuits ( minimum 16 nos ckts) ii) Subscriber loop circuits ( minimum 4 nos ckts) iii) Exchange loop interface circuits (minimum 8 circuits ) iv) This also includes connecting all pigtails, optical patch cords etc. to the SDH equipment. This also includes connection of SDH and primary MUX equipment with all interface cards to the 48V Bus including supply of wires and connectors termination of all evens on DDF taking PVC cable over runway or a wall and termination of VF interface circuit to the Krone type. Inspection:(i) RDSO " | — | 4.00 | — | — | |
| — | — | — | 45,488 | ||
| "Installation, wiring, testing and commissioning of 2 MB Programmable Primary Digital drop insert multiplexer as per RDSO Specs. IRS TC- 68/2004 (Amnd.1) or latest with conference facility and other stipulation to tender documents and fully wired for 30 channels complete with power supply card, remote control, supervision facility and all other accessories, installation material, manuals etc. It should have facilities to accommodate data interface card in multi drop mode and should be able to support cards needed for video conferencing and ISDN. It shall support NMS installed at Test Room and may operate local/remote location of entire section. It also includes submission of all technical documents, manuals and supply of all miscellaneous items which will be required for final testing and commissioning of system. The above MUX should be equipped with following circuits: - i) 2 wire/ 4 wire E&M VF circuits ( minimum 16 nos ckts) ii) Subscriber loop circuits ( minimum 4 nos ckts) iii) Exchange loop interface circuits (minimum 8 circuits ) iv) This also includes connecting all pigtails, optical patch cords etc to the SDH equipment. This also includes connection of SDH and primary MUX equipment with all interface cards to the 48V Bus including supply of wires and connectors termination of all evens on DDF taking PVC cable over runway or a wall and termination of VF interface circuit to the Krone type. All materials such as wires for Earthing & power supply, wire carrying aluminium ladder, MCB, Connectors, foundation bolts, nuts, base frame, mounting accessories for fitting of transformers, U-Link Panels, inter connecting cables etc. required for the above shall be supplied by the contractor." | — | 4.00 | — | — | |
| — | — | — | 4,47,215 | ||
| SUPPLY OF BRIDGE CARD AS PER LATEST SPECIFICATION. THIS INCLUDES SUPPLY OF BRIDGE SHELF (12 CARDS PER SHELF) WITH ALL ACCESSORIES FOR HOUSING THE BRIDGE CARD. INSPECTION BY CONSIGNEE. NOTE: IN CASE THE CARD CONTAIN LESS THAN 8 CIRCUITS OR 6 CIRCUITS PER CARDAS MENTIONED ABOVE, THE EQUIVALENT NO. OF CARDS TO EQUAL THE REQUIREMENT OF 8 CIRCUITS OR 6 CIRCUITS PER CARD MUST BE OFFERED BY THE VENDOR. Make Webfil. | — | 5.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
CheckListAnnexItoVIIIUPDATED_1.pdf
AnnexureIX.pdf
Annexure-X.pdf
Annexure-XI_1.pdf
AnnexureV.pdf
Annexure-VA.pdf
Annexure-VIA.pdf
Annexure-VIB.pdf
GCC-2022-Updated-25.09.24.pdf
JPO-CABLEDIGGINGWORK-VICINITYOFUNDERGROUNDCABLE-SRDSTESRDEN-C-240124.pdf
TermsofPayment.pdf
LabourCessAddendumCorrigendumslipno.4.pdf
ACS1.pdf
ACS2.pdf
ACS3.pdf
ACS4.pdf
ACS5.pdf
ACS6.pdf
ACS7.pdf
ACS8.pdf
ACS9.pdf
ACS10.pdf
Updatedtenderdocument_15-6Q.pdf
EarthElectrode.pdf
TECHNICALCIRCULAR112_CABLEDUCT.pdf
NewEarthPipeDrawing.pdf
AnnexureBDC-TBAE.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .