Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.5 CrAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹1.7 Cr+₹15.3 L (9.99%)Rejected-Finance | 2 | Rejected-Finance L2 | |
| 3 | 3₹1.7 Cr+₹19.6 L (12.8%)Rejected-Finance UTTAR SONAKHALI NARAYANTALA BASANTI SOUTH 24 PARGANAS | BASANTI | SOUTH 24 PARGANAS | WEST BENGAL | 3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | SREE MAA ENGINEERING WORKS L2 | ElectroTrade L1 | TARUN ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.00 | Laying & dressing of following 33 KV XLPE cable in the excavated cable trenches is per drawing no. PLN(D)/SS/126, dt. 23.06.2018 and instruction of the Site Engineer:Cable 33 KV XLPE 3 x 400 sq. mm | 10,485 | Mtr | 81.75 ₹8,57,148.75 | 75 ₹7,86,375 Lowest | 85 ₹8,91,225 |
| 2.00 | Survey of H.T & L.T cable route as per instruction of Site Engineer and submission of route survey drawing ( in two copies) inscribing different land marks | 5,090 | Mtr | 2.94 ₹14,979.87 | 2 ₹10,180 Lowest | 3.1 ₹15,779 |
| 3.00 | Excavation of soil by cutting of Metalled Road/Cement Concrete/Brick Soling etc & re- instatement of the same as per instruction of Site Engineer | 810 | CUM | 150.42 ₹1,21,840.2 | 148 ₹1,19,880 Lowest | 165 ₹1,33,650 |
| 4.00 | supply & laying of 1st Class Bricks (Kiln Burnt) | 30,960 | Nos | 9.49 ₹2,93,934.24 | 9.35 ₹2,89,476 Lowest | 10.85 ₹3,35,916 |
| 5.00 | Supply & fixing/ laying of G.I Pipe (Medium) (Non-TATA) as per I.S.I of the following sizes suitable for cable protection as per instruction of Site Engineer:G.I Pipe 200 mm dia.(Medium) | 72 | Mtr | 2,263.93 ₹1,63,002.96 | 2,256 ₹1,62,432 Lowest | 2,838 ₹2,04,336 |
| 6.00 | Excavation of soil for making of trial hole (Minm. Size 1.1 X 0.5 X 1.2M depth ) as per instruction of the Site Engineer including backfilling the excavated soil. | 31 | CUM | 37.06 ₹1,148.86 | 35 ₹1,085 Lowest | 41.72 ₹1,293.32 |
| 7.00 | Micro-Tunnelling work with laying of HDPE pipe as per instruction of Site Ingineer and as per site condition for laying of U.G. cable including supply of HDPE pipe as per IS: 4984-2016 including preparation and submission of drawing for such cable laying:With 200mm dia. HDPE Pipe of PE-80, PN-6 | 8,730 | Mtr | 1,678.87 ₹1,46,56,535.1 | 1,635 ₹1,42,73,550 Lowest | 1,715 ₹1,49,71,950 |
| 8.00 | Supply & fixing of Aluminium connector as per instruction of the Site Engineer | 24 | Nos | 1,626.28 ₹39,030.72 | 1,585 ₹38,040 Lowest | 1,710 ₹41,040 |
| 9.00 | Fixing of Brackets on existing cable support structure | 6 | Nos | 5,178.59 ₹31,071.54 | 3,535 ₹21,210 Lowest | 6,225 ₹37,350 |
| 10.00 | Making & fixing of end termination joint outdoor type for 33 KV XLPE cable including fixing of the jointing box at the existing structure as per instruction of the Site Engineer: Cable 33 KV XLPE 3 x 400 sq. mm | 4 | Nos | 2,398 ₹9,592 | 2,290 ₹9,160 Lowest | 2,890 ₹11,560 |
Tender Value
Refer Docs
EMD Value
₹3.1 L
Closing Date
5 Mar 2026, 3:00 pmClosed
The Regional Manager
Office of the Regional Manager, South 24 Parganas Region
Laying of 3C 33 KV 400 sq mm XLPE UG cable by Micro tunneling from Birlapur 132 KV GSS to Dongaria PHE1 and PHE2 and others related works for feeding to existing 33 KV Bulk Power at Dongaria PHE1 PHE2 under Behala Division under South
2026_WBSED_994783_1
RM/S24PGS/ETender/2025-26/E-52
Open Tender
ELECTRICAL WORKS ORG
Item Rate
BEHALA
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹3.1 L
Office of the Regional Manager
13 Oct 2026
6 Feb 2026
9 Mar 2026
6 Feb 2026
5 Mar 2026
10 Feb 2026
9 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Laying & dressing of following 33 KV XLPE cable in the excavated cable trenches is per drawing no. PLN(D)/SS/126, dt. 23.06.2018 and instruction of the Site Engineer:Cable 33 KV XLPE 3 x 400 sq. mm | 10,485 | Mtr | - | - |
| 2 | Survey of H.T & L.T cable route as per instruction of Site Engineer and submission of route survey drawing ( in two copies) inscribing different land marks | 5,090 | Mtr | - | - |
| 3 | Excavation of soil by cutting of Metalled Road/Cement Concrete/Brick Soling etc & re- instatement of the same as per instruction of Site Engineer | 810 | CUM | - | - |
| 4 | supply & laying of 1st Class Bricks (Kiln Burnt) | 30,960 | Nos | - | - |
| 5 | Supply & fixing/ laying of G.I Pipe (Medium) (Non-TATA) as per I.S.I of the following sizes suitable for cable protection as per instruction of Site Engineer:G.I Pipe 200 mm dia.(Medium) | 72 | Mtr | - | - |
| 6 | Excavation of soil for making of trial hole (Minm. Size 1.1 X 0.5 X 1.2M depth ) as per instruction of the Site Engineer including backfilling the excavated soil. | 31 | CUM | - | - |
| 7 | Micro-Tunnelling work with laying of HDPE pipe as per instruction of Site Ingineer and as per site condition for laying of U.G. cable including supply of HDPE pipe as per IS: 4984-2016 including preparation and submission of drawing for such cable laying:With 200mm dia. HDPE Pipe of PE-80, PN-6 | 8,730 | Mtr | - | - |
| 8 | Supply & fixing of Aluminium connector as per instruction of the Site Engineer | 24 | Nos | - | - |
| 9 | Fixing of Brackets on existing cable support structure | 6 | Nos | - | - |
| 10 | Making & fixing of end termination joint outdoor type for 33 KV XLPE cable including fixing of the jointing box at the existing structure as per instruction of the Site Engineer: Cable 33 KV XLPE 3 x 400 sq. mm | 4 | Nos | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 10.34 MB
BOQ_2434062.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .