| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹9.4 L+₹45,300 (5.06%)Rejected-Finance | L2 | Rejected-Finance bidder is not L1 | |
| 3 | L3₹9.7 L+₹78,043 (8.72%)Rejected-Finance 12 HAJI MD MOHASIN SQUARE KOL 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L3 | Rejected-Finance bidder is not L1 | |
| 4 | L4₹10.5 L+₹1.6 L (17.6%)Rejected-Finance A 8 SAKHARAM GANESH DAUSKAR SARANI KOLKATA 700 025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L4 | Rejected-Finance bidder is not L1 | |
| 5 | L5₹10.6 L+₹1.6 L (18.1%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L5 | Rejected-Finance bidder is not L1 |
Tender Value
Refer Docs
EMD Value
₹19,461
Closing Date
22 Jan 2025, 3:00 pmClosed
Executive Engineer-I,CKHED,PWDte.
Central Kolkata Health Electrical Division P-12, C.I.T Road(1st floor) KOLKATA
Air conditioning arrangement of the 1st floor Office space of CMS, Kolkata
2025_WBPWD_795920_1
WBPWD/EE-I/CKHED/eNIT-93( R )/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
CMS
Please refer Tender documents.
3 documents required · 3 mandatory
₹19,461
Central Kolkata Health Electrical Division
11 Apr 2025
7 Jan 2025
27 Jan 2025
7 Jan 2025
22 Jan 2025
14 Jan 2025
14 Jan 2025
Amount
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Vide page No D-11, Item No-15] Incoming - 415V, 25/35KA, 160A, FPMCCB (1 -nos)[Vide page No D-8, Item No-10] Outgoing - 10KA, (C-characteristics) 63A, TPMCB - (6 -nos)[Vide page No D-6, Item No-7
6 way [Legrand/ L&T]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [D-10, 14] Incoming - 415V,63A, FPMCB Isolator [ Legrand ] (1-nos) [ D-5,6 ] (1-nos) Outgoing - 10KA, (C-characteristics) 6-32A, SPMCB [ Legrand ]- (18-nos) [ D-6,7 ]
6 way [Legrand/ L&T]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Gloster/RR Kable/Finolex) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire incl. cutting channel and making necy. connection as required. [E-9,1]
a) 4x6 sqmm+2x 4sqmm ECC [Vide page no-E-9,item no-1(s)]
e) 4 x 10 sqmm+2x 6 sqmm ECC) [ For AC ] [Vide page no-E-9,item no-1(d1)]
f) 4 x 16 sqmm + 2 x 10 sqmm ECC) [ VTPN to TPNDB ] [Vide page no-E-9,item no-1(g1)]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.[Vide page No F-5, Item No-9 (i)& (ii)]
4 x 6 sqmm+2x 4 sqmm ECC) [(F-5,9(iii&ii))]
4 x 10 sqmm + 2 x 6 sqmm ECC [ F-5,9(iv&iii)]
4 x 16 sqmm + 2 x 10 sqmm ECC) [ F-5,9(v&iv)]
Supply and Delivery of 1.1 KV grade following sizes Al. armoured PVC/XLPE cable (Gloster/Havells/polycab/KEI/Currency) as mentioned below as per choise of EIC.
4 Core 70 sqmm
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. [[Vide page No F-1, Item No-2(d)]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. [[Vide page No F-4, Item No-7]
4 Core 70 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. [Vide page No F-5, Item No-8(b)]
4 Core 70 sqmm
Supply & Delivary 7.5TR capacity concealed type Split Air Conditioner of rated cooling capacity of 90000 BTU/hr. with 3Nos. rotary compressor, 3nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-400V-3ph-50Hz. Air-flow/per IDU:- 1000CFM. ( Make: Hitachi/Voltas/Daiking)
Supply & Delivery of 5 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 60000 BTU/hr. with 2 Nos. rotary compressor, refrigerant R-410A, 2 nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-400V-3ph-50Hz. Air-flow/per IDU:- 1000CFM. ( Make: Hitachi/Voltas/Daiking)
Erection & Commissioning Charges incl. refrigerant R-410A for 7.5 TR concealed type Split Air Conditioner
Erection & Commissioning Charges incl. refrigerant R-410A 5TR concealed type Split Air Conditioner
Copper Refrigeration pipe line for liquid and suction line with fittings, elbows, bends, supports & brackets (Make-Ryoku)
(5/8" OD with 0.6 mm thick) Make- Ryoku
(3/8" OD with 0.6 mm thick) Make- Ryoku
Supply & Fixing Pipe Insulation in liquid & suction line with 9mm nitrile rubber tube (Accoflex)
b) (3/8" OD with 0.6 mm thick)
(5/8" OD with 0.6 mm thick)
Control copper Cabling from Condensing Unit to control panel (Make: KEI/polycab/ finolex)
a) 4 core 2.5 sq.mm communication cable
S & L of Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors.
a) 25 mm dia
Charges for scaffolding arrangement incl. lifting for outdoor & indoor units
Supply and fixing flexible canvass connection for concealed split air-conditioners.
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (50 mm x 50 mm x 6 mm) for making platform for installation of outdoor unit of Concealed split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be barricaded & safe for ODU maintenance. Area of the platform is 3Mtr. x 1.2Mtr.Structural design should be approved by E.I.C.
Cutting iron windows and macking door there for passage for outdoor installation, fixing and provision for future maintenance purpose. Including charges of welding , masonary charges, labour charges and materials charges for sand ,cement , chipes etc.
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
R.N.ROY ELECTRICAL CONTRACTOR (BID ID -5996587)
MODERN REFRIGERATION AND ELECTRICAL WORKS (BID ID -6035027)
MAXCOOL REFRIGERATION CO. (BID ID -5998367)
SKY DECORATIONS PRIVATE LIMITED (BID ID -5994860)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .