Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.3 LAccepted-AOC NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | L-1 | Accepted-AOC FOUND LOWEST AND REASONABLE | |
| 2 | L-2₹31.2 L+₹7.7 L (32.9%)Rejected-Finance H O 325 JAIPUR HOUSE AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | L-2 | Rejected-Finance Being other than lowest | |
| 3 | L-3₹31.8 L+₹8.4 L (35.7%)Rejected-Finance 179 143 1 INDA NEAR SHAKTI BHAVAN KHARAGPUR 721305 | KHARAGPUR | PASCHIM MIDNAPORE | WEST BENGAL | 721305 | L-3 | Rejected-Finance Being other than lowest | |
| 4 | L-4₹32.4 L+₹8.9 L (38.0%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L-4 | Rejected-Finance Being other than lowest | |
| 5 | L-5₹37.9 L+₹14.4 L (61.4%)Rejected-Finance | L-5 | Rejected-Finance Being other than lowest |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
19 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) TECH AREA AGRA
GE (AF) TECH AREA AGRA
REPAIR/MAINT OF ELECTRICALLY OPERATED HANGAR GATE INSTALLED AT BLDG NO P-567, P-568, P-569 P-570,T-7 AND T-8 UNDER GE(AF) (TECH AREA) AT AF STN, AGRA
2021_MES_496901_1
8200-1370/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) TECH AREA AGRA
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) TECH AREA AGRA
₹72,000
Yes
21 Mar 2022
23 Dec 2021
21 Jan 2022
23 Dec 2021
19 Jan 2022
7 Jan 2022
23 Dec 2021 - 29 Dec 2021
60 days
Amount
Repair & maintenance of guide chanel & wheels of (Hanger gate having height upto 22 Mtr) for Bldg No P-567 front and rear having total 24 leaves(12 leaf each side) including greasing/ oiling and repair maintenance and servicing of gear box for smooth transmission of power to operate the gate smooothly. The work shall be got executed as per direction given by Engr-in-Charge.
Repair & maintenance of guide chanel & wheels of (Hanger gate having height upto 22 Mtr) for Bldg No P-568 front and rear having total 24 leaves(12 leaf each side) including greasing/ oiling and repair maintenance and servicing of gear box for smooth transmission of power to operate the gate smooothly. The work shall be got executed as per direction given by Engr-in-Charge.
Repair & maintenance of guide chanel & wheels of (Hanger gate having height upto 22 Mtr) for Bldg No P-569 front and rear having total 24 leaves(12 leaf each side) including greasing/ oiling and repair maintenance and servicing of gear box for smooth transmission of power to operate the gate smooothly. The work shall be got executed as per direction given by Engr-in-Charge.
Repair & maintenance of guide chanel & wheels of (Hanger gate having height upto 15 Mtr) for Bldg No P-570 front and rear having total 8 leaves(4 leaf each side) including greasing/ oiling and repair maintenance and servicing of gear box for smooth transmission of power to operate the gate smooothly. The work shall be got executed as per direction given by Engr-in-Charge.
Repair & maintenance of guide chanel & wheels of (Hanger gate having height upto 22 Mtr) for Bldg No T-7 front side having 8 leaf including greasing/ oiling and repair maintenance and servicing of gear box for smooth transmission of power to operate the gate smooothly. The work shall be got executed as per direction given by Engr-in-Charge.
Repair & maintenance of guide chanel & wheels of (Hanger gate having height upto 22 Mtr) for Bldg No T-8 front side having 8 leaf including greasing/ oilingand repair maintenance and servicing of gear box for smooth transmission of power to operate the gate smooothly. The work shall be got executed as per direction given by Engr-in-Charge.
Repair to top track trolly with 12 Nos horizontal axis rollers & 4 Nos vertical axis rollers including replacement of unserviceable part & hardware, bearings & steel rope for smooth working/operation of gate complete all as specified and directed. (For hangar height upto 22 Mtr) Make : Unidor TM or equivalent as approved by GE.
Repair to top track trolly with 8 Nos horizontal axis rollers & 4 Nos vertical axis rollers including replacement of unserviceable part ie. hardware, bearings & steel rope for smooth working/operation of gate complete all as specified and directed. (For hangar height upto 15 Mtr) Make : Unidor TM or equivalent as approved by GE.
Repair to top track trolly with 8 Nos horizontal axis rollers & 4 Nos vertical axis rollers including replacement of unserviceable part & hardware, bearings & steel rope for smooth working/operation of gate complete all as specified and directed. (For hangar height upto 22 Mtr) Make : Unidor TM or equivalent as approved by GE.
Note : For Item 1 to 6:- (i) Contractor shall visit the site of work prior quoting the rates against respective items. Further the contractor shall visit site every week and will check and carry out service and repair as to required at site and as directed by Engr-in-Charge. (ii) Payment will be made only once for the month for any number of complaints/breakdowns. (iii) Any other repair/maint required shall be measured & paid seprately(as persite requirement) under respective items herein after. (iv) During maintenance and replair/replacement of gate, any damage including civil work occurs, the same shall be make good by the contractor without any exta cost to Govt. (v) Contractor shall repair/replace the item of gate and make the gate smooth for working/operating with immediate as pointed out by Engineer-in-Charge. If contractor fails to do the same within 07 days, a panelty for the same @ 2000/- per day shall be charged from the contractor. (vi) Cost of all the special T&P and tools including boom lift etc as required shall be deemed to be included in the unit rate quoted. No extra charge shall be paid for this purpose. (vii) Contractor shall deployed trained tradesmen. The trademen shall be qualified to keep equipment properly and take care to maintain hanger gate in proper and safe operating condition. (viii) Contractor shall examine periodically maintance and repair including safety devices and make proper record of testing in the form of monthly, Quarterly, and yearly basis.
S&F mild steel work such as stopper to guide chanel and other similar items including cutting welding conforming to E-290 grade E-165 as per existing shape/size complete all as specified and directed.
M&L for welding n exc 10 cm in length and thickness of metal to be welded not exc 6mm complete all as specified and directed.
S&F in replacement proxy switches M-30 of existing capacity complete all as specified and directed
S&F in replacement indicator of gate fixed at door with start stop and emergency switch of existing make/size/capacity complete all as specified and directed.
Repair including replacement of defective/wornout parts in control panel of gate including wiring & electrical fitting/fixture (from control panel to starter) complete all as specified and directed.
S&F in replacement of unserviceable glass relay 24V DC,500 ohm complete all as specified directed.
S&F in replacement MCB SP 6 to 32 Amp 240 V 'C' Series 10 KA complete all as specified and directed.
S&Fin replacement MCB TP 32 to 63 Amp 240 V 'C' Series 10 KA complete all as specified and directed.
S&F in replacement power supply AC to DC 220V/24V complete all as specified and directed.
S&F Laying connecting and testing in replacement of LT Cable of size 2.5 Sqmm 4 core, 1100 Volt PVC insulated heavy duty flexible cable with ennealed bare copper conductor flexible industrial cable complete all as specified and directed.
S&F Laying connecting and testing in replacement of LT Cable of size 1sqmm 4 Core 1100 Volt PVC insulated of flexible cable with ennealed bare copper conductor flexible industrial cable complete all as specified and directed.
S&F in replacement controlled wire of size 1 Sqmm multi standard copper conductor PVC insulated with colour code grey & black complete all as specified and directed.
S&F in replacement PVC connector with 2 Amp rating glass fuse NS4 complete all as specified and directed.
S&F in replacement of digital type Amp meter 0 to 200 Amp as per existing size complete all as specified and directed.
S&F in replacement of thermal over load relay of capacity 5 to 12 Amp rating complete all as specified and directed.
S&F in replacement of contactor 3 pole 220 Volt 16Amp with NC block complete all as specified and directed.
Supply & refilling/ Top up of gear oil in special geared motors .
M&L for Radium sheet with letters or numbers of any width & height , pasted on 1mm thick galvanised plain MS sheet of size 1.2 Mtr x 1.2 Mtr with necessary fixing arrengement on hanger doors complete all as specified and directed
Dismantling / taking out gear motor capacity 2/2.5 HP 3 phase including disconnecting electric connection and transporting to workshop for repairing works including rewinding with super enamelled copper winding wire of existing gauge and replacement of unserviceable bearing etc complete all as specified and directed
M&L for repairing of parachute hanging devices installed at PP&RS including replacement of unserviceable parts and control wiring, contactor etc and servicing of motors to make the parachute hanging devices serviceable as directed by Engineer-in-charge and specified by users manual of manufacturer with smooth operation all as specified and directed. Note:- (i)The contractor has to visit the site of parachute hanging device installed at PP&RS before quotting the rates. (ii) The contractor has to provide all special T&P to access the parachute hanging device for neccessary repairs (iii) The contractor will appproach the OEM/rep of OEM for any special guidance if repair the above hanging devices is required for smooth function of parachute hanging device and this provision is deemed to be included in quoted rates. (iv) Testing of parachute hanging devices with full satisfaction of user and Engineer-in-charge after carrying out repair work.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .