Loading…
Loading…
Tender Value
₹43.9 L
EMD Value
₹87,900
Closing Date
18 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Fund (DRF)
TECHNICAL
12 conditions · 1 needing a document upload
Offers received from the firms, who are either working or completed Supply, installation and commissioning of chiller pipe, pump and its associated work for centralize AC plant with Government department or semi Government department shall only be entertained
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Replacement of old chilled water pipe line of main AC plant installed at IRCA Building New Delhi.
150-Elect-Elect-CR-416
150-Elect-Elect-CR-416
Open
Works - General
6 Months
South West, Delhi
₹0
₹87,900
18 Mar 2026
23 Feb 2026
4 Mar 2026
45 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 43,93,500 | ||
| — | — | — | 50,000 | ||
| Dismantling of old unserviceable insulated chilled water pipeline from the AC Plant room and removing the old pipe line with associate equipments from the AC Plant room and keeping in safe custody of SSB/Depot, or SSE/Elect/Store as per Railway's requirement. | — | 1.00 | — | — | |
| — | — | — | 3,36,000 | ||
| Supply, installation, Testing and commissioning of MS piping,Size 200 mm dia NB, minimum 6 mm thick , C Class as per IS 1239 (Part 1) 2004/IS:3589) of reputed make and connecting to various AHUs ,plants,Pump etc along with associated accessories as per site requirement and technical specification attached. | — | 70.00 | — | — | |
| — | — | — | 1,70,000 | ||
| Supply, installation, Testing and commissioning of MS piping,Size 150 mm dia NB, C Class as per IS 1239 (Part 1) 2004/IS:3589) of reputed make and connecting to various AHUs ,plants,Pump etc along with associated accessories as per site requirement and technical specification attached. | — | 50.00 | — | — | |
| — | — | — | 1,55,000 | ||
| Supply, installation, Testing and commissioning of MS piping,Size 125 mm dia NB, C Class as per IS 1239 (Part 1) 2004/IS:3589) of reputed make and connecting to various AHUs ,plants,Pump etc along with associated accessories as per site requirement and technical specification attached. | — | 50.00 | — | — | |
| — | — | — | 3,42,000 | ||
| Supply, installation, Testing and commissioning of MS piping,Size 100 mm dia NB,C Class as per IS 1239 (Part 1) 2004/IS:3589) of reputed make and connecting to various AHUs ,plants,Pump etc along with associated accessories as per site requirement and technical specification attached. | — | 120.00 | — | — | |
| — | — | — | 2,16,000 | ||
| Supply, installation, Testing and commissioning of MS piping,Size 80 mm dia NB, C Class as per IS 1239 (Part 1) 2004/IS:3589) of reputed make and connecting to various AHUs ,plants,Pump etc along with associated accessories as per site requirement and technical specification attached. | — | 90.00 | — | — | |
| — | — | — | 80,000 | ||
| Supply, installation, Testing and commissioning of MS piping,Size 50 mm dia NB, B Class pipe for drain piping. | — | 50.00 | — | — | |
| — | — | — | 1,54,000 | ||
| Insulation on chilled water piping ,size 200 mm dia X 75 mm thick using expanded polystyrene (20 kg/cu m density) TF grade pipe section covered with vapour barrier (500 mil polyethylene sheet) wrapped with expanded wiremesh and finished with sand cement mortar and painted with synthetic enamel paint as per the site requirement and technical specification attached. | — | 70.00 | — | — | |
| — | — | — | 90,000 | ||
| Insulation on chilled water piping ,size 150 mm dia X 50 mm thick using expanded polystyrene (20 kg/cu m density) TF grade pipe section covered with vapour barrier (500 mil polyethylene sheet) wrapped with expanded wiremesh and finished with sand cement mortar and painted with synthetic enamel paint as per the site requirement and technical specification attached. | — | 50.00 | — | — | |
| — | — | — | 70,000 | ||
| Insulation on chilled water piping ,size 125 mm dia X 50 mm thick using expanded polystyrene (20 kg/cu m density) TF grade pipe section covered with vapour barrier (500 mil polyethylene sheet) wrapped with expanded wiremesh and finished with sand cement mortar and painted with synthetic enamel paint as per the site requirement and technical specification attached. | — | 50.00 | — | — | |
| — | — | — | 1,32,000 | ||
| Insulation on chilled water piping ,size 100 mm dia X 50 mm thick using expanded polystyrene (20 kg/cu m density) TF grade pipe section covered with vapour barrier (500 mil polyethylene sheet) wrapped with expanded wiremesh and finished with sand cement mortar and painted with synthetic enamel paint as per the site requirement and technical specification attached. | — | 120.00 | — | — | |
| — | — | — | 67,500 | ||
| Insulation on chilled water piping ,size 80 mm dia X 50 mm thick using expanded polystyrene (20 kg/cu m density) TF grade pipe section covered with vapour barrier (500 mil polyethylene sheet) wrapped with expanded wiremesh and finished with sand cement mortar and painted with synthetic enamel paint as per the site requirement and technical specification attached. | — | 90.00 | — | — | |
| — | — | — | 27,500 | ||
| Insulation on chilled water piping ,size 50 mm dia X 25 mm thick for drain pipe using expanded polystyrene (20 kg/cu m density) TF grade pipe section covered with vapour barrier (500 mil polyethylene sheet) wrapped with expanded wiremesh and finished with sand cement mortar and painted with synthetic enamel paint as per the site requirement and technical specification attached. | — | 50.00 | — | — | |
| — | — | — | 68,000 | ||
| Supply, installation, Testing and commissioning of Butterfly valves, PN 10 (Make: Flowserve (Audco)/C&S/Marck/Advance) reputed make,size 125mm in the chilled water pipeline duly insulated in the same manner as the insulated pipeline as per the site requirement and technical specification attached. | — | 8.00 | — | — | |
| — | — | — | 72,000 | ||
| Supply, installation, Testing and commissioning of Butterfly valves, PN 10 (Make: Flowserve (Audco)/C&S/Marck/Advance) reputed make,size 80 mm in the chilled water pipeline duly insulated in the same manner as the insulated pipeline as per the site requirement and technical specification attached. | — | 16.00 | — | — | |
| — | — | — | 1,12,000 | ||
| Supply, installation, Testing and commissioning of Balancing valves (Make : C&S/Marck/Advance)reputed make,size 125mm in the chilled water pipeline duly insulated in the same manner as the insulated pipeline as per the site requirement and technical specification attached. | — | 4.00 | — | — | |
| — | — | — | 1,52,000 | ||
| Supply, installation, Testing and commissioning of Balancing valves (Make : C&S/Marck/Advance)reputed make,size 80 mm in the chilled water pipeline duly insulated in the same manner as the insulated pipeline as per the site requirement and technical specification attached. | — | 8.00 | — | — | |
| — | — | — | 32,000 | ||
| Supply, installation, Testing and commissioning of Dual Plate Non Return valves (Make : C&S/Marck/Advance) size 125mm in the chilled water pipeline duly insulated in the same manner as the insulated pipeline as per the site requirement and technical specification attached. | — | 4.00 | — | — | |
| — | — | — | 34,000 | ||
| upply, installation, Testing and commissioning of Y Strainer (Make : SANT/DS Engg./Marck/Emerald) ,ize 125mm in the chilled water pipeline duly insulated in the same manner as the insulated pipeline as per the site requirement and technical specification attached. | — | 4.00 | — | — | |
| — | — | — | 3,36,000 | ||
| Supply, installation, Testing and commissioning of 65mm(Size) 3 way modulating valve in globe valve type construction and linear in operation complete with actuator and control thermostat (digital) of Siemens/Honeywell/Belimo make in the chilled water pipeline duly insulated in the same manner as the insulated pipeline as per the site requirement and technical specification attached. | — | 8.00 | — | — | |
| — | — | — | 12,60,000 | ||
| Replacement with supply, installation, Testing and commissioning of horizontal split casing pump set having CI impeller, non - asbestos gland packing and coupled with suitable TEFC electric motor operating on 1450 RPM with factory fitted base frame complete as required suitable for delivering 81 CMH at 38 m head for chilled water pumping requirement, duly insulated with nitrile rubber sheet pasted on the pump body as per the site requirement and technical specification attached. (Makes of Pumps: Wilp (M&P)/ Jyoti/ KSB/ Flowmore/ Beacon - weir; Motors:Siemens/ ABB/ Crompton/ Kirloskar) | — | 4.00 | — | — | |
| — | — | — | 4,37,500 | ||
| Steel structural work for making bridge for supporting/ running chilled water main supply/ return pipeline over and above the steel fabricated bridge structure to run between the AC plant room and the main IRCA building including making suitable concrete foundations for supporting the steel structure columns as required. The design shall be got checked from Dy CEE/PRS or the concerned SSE before starting the work. The steel structure would be painted using synthetic enamel paint including application of red oxide preimer as required. | — | 2500.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Chilledwaterpipe_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .