Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹5,980
Closing Date
14 Sept 2020, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE O and M TKGTPS
T(K)GTPS, Thirumakottai
Routine ,preventive ,breakdown maintenance in AC and HRSG system
2020_EB_177516_1
Enq.No.W-170/20
Open Tender
Miscellaneous Works
Works
180 days
TKGTPS, Thirumakottai
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹5,980
Yes
17 Sept 2020
27 Aug 2020
15 Sept 2020
27 Aug 2020
14 Sept 2020
27 Aug 2020
180 days
Amount
Regular maintenance works inAC &HRSG system at T(K)GTPS
Maintenance of 60TR-centralised A/c system for central control room Charges for Routine Inspection for any abnormal noise, leak in 60TR centralized A/c Compressor, condenser and Air handling unit etc., as per the direction of Engineer in charge.
Charges for attending leak in the system by testing with N2 Gas and refilling of R22 Gas, replacement of oil seal and alignment of motor in the centralized A/C Plant as per the direction of Engineer in charge.
Charges for manual descaling of condenser unit of centralized A/C System using wire brush as per the direction of Engineer in charge.
Charges for cleaning of Air handling Unit Blower Fan or replacement of V Belts, greasing of bearing or cleaning of filter elements etc., of centralized A/C System as per the direction of Engineer in charge.
Charges for attending gland leak or topping up of oil replacement of bearing etc., in condenser Cooling water Pump of centralized A/C System and alignment of motor as per the direction of Engineer in charge.
Charges for cleaning of Cooling Tower Fins or checking of alignment of Cooling Tower Fan blade, motor etc., as per the direction of Engineer in charge
Maintenance of 15 TR packaged A/c unit at switchyard control room Charges for Routine inspection for any abnormal noise, leak in 15TR packaged A/C Compressor, Condenser and Blower Unit etc., of packaged A/C Unit of Switchyard Control Room as per the direction of Engineer in charge.
Charges for attending leak in the System by testing with N2 Gas and refilling of R22 Gas in the packaged A/C unit of Switchyard Control Room as per the direction of Engineer in charge.
Charges for servicing of condenser outdoor unit of the packaged A/C unit at Switchyard Control Room as per the direction of Engineer in charge
Maintenance of split A/c unit at various locations Charges for Routine inspection for any abnormal noise, leak in condenser and Blower unit etc., of split A/C Unit as per the direction of Engineer in charge.
Charges for attending leak in the system by testing with N2 Gas and refilling of R22 Gas replacement of electrical spares etc., in the split A/C unit as per the direction of Engineer in charge.
Charges for servicing of condenser outdoor unit of the split A/C unit as per the direction of Engineer in charge
Maintenance of window A/c units at various locations Charges for servicing 1 No. window A/C unit once in 3 months (or) replacement of Electrical spares or rewinding of Blower Fan Motor etc., as per the direction of Engineer in charge
Attending leaks in high pressure valves upto 1/2" to 11/2 '' in HRSG Attending leaks in valves by renewal of Gland packing / flange gaskets and tightening of valve gland/flanges as per the direction of Engineer in charge
Attending leaks in high pressure valves of size 2" to 4" in HRSG Attending leaks in valves by renewal of Gland packing / flange gaskets and tightening of valve gland/flanges as per the direction of Engineer in charge
Regular maintenance works in Phosphate dosing tank cleaning, flushing of lines/ attending leaks in valves/flanges / renewal of gland rope in pumps, loading and unloading of materials as per the direction of Engineer in charge
Charges for dismantling the sample coolers (HP/IP/LP) from its original position, lowering downing end cleaning of inlet and outlet valves, releasing the choked cooler bundles throughly using HCl acid and assembling again into original position, as per the direction of Engineer in charge
Attending leaks in pipe lines / renewal of pipe lines/ renewal of valves upto 1½” in HRSG Weld joints as per the direction of Engineer in charge
Attending leaks in pipe lines / renewal of pipe lines/ renewal of valves from 2 “ to 4” in HRSG Weld joints as per the direction of Engineer in charge
Periodical maintenance of Walkdown and visual inspection of HRSG drain system, IBD and CBD tanks, connected pipe lines and valves, etc., observe for any water/steam leaks and rectify the minor defects by tightening of gland / removal of gland packing's and replacing by new one, lubricating of valves, easying the valve operation and renewal of gaskets as per the Direction of Engineer In-charge
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .