| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.4 L+₹3.9 L (15.9%)Rejected-Finance 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance L2 | |
| 3 | L3₹28.7 L+₹4.2 L (17.3%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | - | Rejected-Technical not having catagory as per NIT |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
12 Jul 2025, 6:00 pmClosed
CWE PATIALA
HQ COMMANDER WORKS ENGINEER BLDG No 26 NEW LALBAGH PATIALA 147001 Contact 01752200082
REPAIR REPLACEMENT OF UNSERVICEABLE LIGHTENING PROTECTION SYSTEM FLAME PROOF FITTINGS AND ALLIED MAINT WORKS IN TECH/DOMESTIC AREA AT MIL STN DAPPAR
2025_MES_712684_1
CWE/PAT/T-02/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DAPPAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
AGE I DAPPAR
₹74,000
5 Aug 2025
5 Jun 2025
14 Jul 2025
5 Jun 2025
12 Jul 2025
28 Jun 2025
5 Jun 2025 - 26 Jun 2025
Amount
Taking down carefully Copper/aluminium / flame proof point wiring on wooden batten /in pvc conduit /steel conduit, on surface / pvc casing and capping (light/Socket/Power) complete including (any type of fittings such as switches, ceiling roses, pendants, regulators, sockets etc) making good distrubed surfaces of walls. Floors etc to match with the existing including disconnection of electric connections, complete all as specifed and as directed.
M&L for Flame proof point wiring with single core PVC insulated and unsheathed 1100 volt grade (FRLSH) electric cable with multi stranded copper conductor of size2.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia surface type including all flame proof conduit fittings and accessories such as tees, junction boxes, bends, clamps, screws etc duly tested / certified by CMRI Dhanbad suitable for six lights controlled by one flame proof rotary switch SP one way and including drawing continuous earth wire PVC insulated unsheathed 1100V grade cable with stranded copper conductor of size 2.5 Sqmm and connected to earth dolly complete conforming to IS-694 all as specified and as directed.
M&L for Flame proof point wiring with single core PVC insulated and unsheathed 1100 volt grade (FRLSH) electric cable with multi stranded copper conductor of size 1.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia surface type including all flame proof conduct fittings and accessories such as tees,junction boxes, bends, clamps, screw etc duly tested / certified by CMRI Dhanbad suitable for two lights controlled by one flame proof rotary switch SP one way and including drawing continuous earth wire PVC insulated unsheathed 1100V grade cable with stranded copper conductor of size 1.5 Sqmm and connected to earth dolly complete conforming to IS-694 all as specified and as directed.
Re-fixing of any type of light fitting at any height dislocated from its original place or after dismantling from its orignal place at a location as directed complete all as specified and as directed. Note:- Minor spares like / connecting wire less than 1 mtrs, screws, raul Plug & making smooth the distrubed surface will be included in the quoted rate
S&F totally enclosed flame proof/weather proof direct entry type rotary switch single pole on & OFF rotary motion switch in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 230Volts 16 Amps, AC ON/OFF switch operated externally by Knob having 02 Nos of M-20 cable entries, earthing terminals suitable for mounting on Wall/Steel structure etc duly tested / certified by CMRI-Dhanbad complete all as specified and as directed.
S& F in repair totally enclosed flame proof/weather proof LED fixture 2x20 Watts 1200mm with aluminium extruded and aluminium heat sink, System Lumen Efficacy ≥100 Lm/W operating Voltage between 140-270Vac , Power Factor more than 0.90%, LED Driving Current < 70% of rated maximum forward current,THD less than 20%, CRI more than 80%, Luminaire intergal driver with 2KV surge protection, Over Load Protection, No Load Protection and BIS Marking (R no. for Driver), Driver Certiifcation IEC64347-2-13 IS(15885), Over all electrical efficency more than 90%, Driver electrical efficiency will be > 85%, with 2 year warranty all as specified and as directed.
S&F in replacement Flame proof 8 way distribution board for mounting MCBs/RCBO's ELCB etc. as per IS specification and CMRI approved of factory made fabricated out of cast aluminium alloy LM-06 grey appoxy powder coated finish, fitted with DIN Channel neutral link, Earth links and 200 Amps rated bus bar. The DB shall be having with IP-65 protection. The DBs shall also be consisting and including the following:- (a) MCB SPN 230 volts AC 50 Hz 40 Amps - 01 Nos (b) MCB single pole 240 volts AC 50 Hz 10 Amps - 6 Nos.
S&F in repair/replacement flame proof flexible metalic hose conduit 20 mm dia complete all as specified and as directed.
S & F in replacement 100W LED flame Proof Flood Light with System Lumen Efficacy≥100 Lm/W operating Voltage between 140-270Vac, Driver will have cut off at > 300 Vac, Power Factor more than 0.95%, LED CCT 5665±355K as per ANSI BIN, LED Driving Current < 70% of rated maximum forward current, Luminaire intergal driver with 5KV surge protection, Over Load Protection, No Load Protection and BIS Marking (R no. for Driver), Driver Certiifcation IEC64347-2-13 IS(15885), Driver should be concealed under IP66,Over all electrical efficency more than 90%, Driver electrical efficiency will be > 85% connecting with PVC copper cable of size 3x1 sqmm as per IS 10322 at Least 2 Year on site warranty without any condition.complete as specified and as directed.
M & L in replacement earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to galvanised iron steel earth lead wire 4 mm dia by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC reinforced pit cover, and charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SI Part-I ( 2009). complete all as specided and directed. NOTE :- The unit rate includes for protection pipe 15mm and GI earth wire 4mm from top of earth plate upto 7.50 mtr above ground level.
M & L for replacement of flame proof top for flame proof Switch / socket as per sample complete all as specified and directed.
S &F in replacement flame proof socket & plug combined in LM6 cable termination box in LM6, 16A 415V 4P + earth complete all as specifed and as directed.
S&F in replacement Flame proof sub main wiring with two single core 6 sqmm + 1 x 6 Sqmm earth wire multistandard copper conductor cable (FRLSH), PVC insulated cable 1100 volts grade and 6 Sqmm as continious earthing single core copper continious earthign drawing and including extra including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 25 mm dia surface type including all flame proof conduit fittings all as specified and as directed.
S&F in replacement Flame proof sub main wiring with two single core 2.5 sqmm + 1 x 2.5 Sqmm earth wire multistandard copper conductor cable (FRLSH), PVC insulated cable 1100 volts grade and 2.5 Sqmm as continous earthing single core copper continous earthing drawing in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20 mm dia surface type including all flame proof conduct fittings all as specified and as directed.
S&F in replacement Flame proof socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and as directed.
M&L for replacement of earthing complete with and including using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of the plate not less than 1.5 m below the normal ground level connected with 20 x 3mm as earthing lead/ strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber and pit cover in PCC (1:2:4), type B1, using 20 mm graded stone aggregate, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade GI pipe for watering, 40 mm dia light grade Gl pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-I (2009) connected to earthing test point all as specified and indicated including testing on completion all as specified and as directed by Engineer-in-Charge. NOTE : - (i). Earthing strip GI/copper upto 7.5m will be measured and paid under this item only. (ii). The earth chamber shall be constructed 50 cm away from the edge of earth pit and the cost of the same is deemed to be included in the rate quoted for above item. (ii). Quoted rate is deemed to be inclusive of cost of demolition of old earthing as directed by Engr-in-Charge. (iii). The new earthing so constructed must have resisitance value below 2 ohms. If the aforesaid resistance value is not achieved contractor has to make proper aadditions/alterations to the newly constructed earthing at his own cost.
S&F in replacement thread type lamp holder procelain base / as per sample for flame proof fitting complete all as specifed and as directed.
S&Fin replacement thread based LED lamp 14Watt suitable for existing lamp holder proided under Ser item No 17here-in-before complete all as specified and as directed. Note:- The cost of necessary connection wire FRLSH making connection shall deemed to be included in the quoted rate.
Re-fixing of static discharge handle dislocated from its original position all as specified and directed. Note:- The cost of any minor repairs to the wall surface, screws, nut bolts, washers etc required for the purpose shall deemed to be included in quoted rates)
S&F in replacment of copper earth strip of size 20 x 3 mm buried in ground or fixed on wall connecting at ends, nuts and bults, jointing alongwith suitable size of PVC / ceramic insulators as directed Engr-in-Charge complete all as specified and as directed.
Demolition and taking out old damaged earth pit PCC chamber with cover and M& L for preparation of new PCC chamber and pit cover in cement concrete 1:2:4 type B1 all all as shown electrical plate No-3 of SSR-2009 Part-I complete all as specified and directed
Re-fixing of dislocated aluminium / GI strip / Copper strip of any size and at any height to its place after proper straightening on insulators using required size of screws for proper fixing of strip insulators complete all as specified and as directed. NOTE - The cost of any type of job like drilling, welding, screws etc. required for fixing of strip and required insulators on the any size / type on existing surface like PCC wall, asbestos sheet, etc. at site shall deemed to be included in the quoted rates.
Re fixing of dislocated aluminium terminal rod of any size and at any height using required suitable nut and bolts , screws etccomplete all as specified and directed.
Dismantling and taking down distroted / broken Aluminium strip of any size including removal of broken / distroted insulators from the roof / along the wall / floor and making smooth the disturbed surface with minor masonry repairs as required and all as per specified and directed by Engr-in-Charge.
Dismantling and taking down distroted / broken GI strip of any size including removal of broken / distroted insulators from the roof / along the wall / floor and making smooth the disturbed surface with minor masonry repairs as required complete all as r specified and as directed.
M&L for cement conctere (1:2:4) type B1 (using 20 mm graded stone aggregate) for replacement of block of suitable size including necessary form work for grouting of porcelain/PVC insulators on the roof (appx. 35 feet above GL) and making good to PCC pavement/road/hard standing etc complete all as specified and as directed. NOTE: - (i) Size of PCC block required for erection of GI pipe-air termination arrangement shall be approved by Engieer-in-charge (ii) The quoted unit rate shall deemed to be inclusive of arrangements required for fixing of PCC blocks at any height and on any surface.
S&F in replacement air termination single pointed, aluminium rod 12 mm dia and 300mm long at any height, to be screwed and sturdily fixed to GI pipe of 40 mm dia with and including two sets of suitable size nut, bolt, washers (02 Nos.) complete all as specified and as directed. NOTE:- PCC block and GI pipe required shall be measured and paid separately under relevant items of Sch 'A'.
S&F aluminium strip of size 25 x 3.15mm for lighting protection at any height on roof / along the wall / floor duly fixed on suitable size of PVC / ceramic insulators with a gap of not greater than 1 mtr between two inslators complete all as secified and as directed by Engineer-in-Charge. Note:- The cost of insulators of required size and screws for proper fixing of strip shall deemed to be included in quoted rates.
All as per serial item No 28 here-in-before but GI strip of size 32 mm x 6 mm.
M&L for earthing complete with galvanized steel earth plate electrode 60×60cm×6mm thick electrode burried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with 32×6 mm galvanized iron as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber and pit cover in PCC (1:2:4), type B1, using 20 mm graded stone aggregate, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade GI pipe for watering, 40 mm dia light grade Gl pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-I (2009) connected to earthing test point as indicated and testing on completion including dismantling and removing old unserviceable earthing complete all as specified all as directed. NOTE : - (i). Earthing strip GI upto 7.5m will be measured and paid under this item only. (ii). The earth chamber shall be constructed 50 cm away from the edge of earth pit and the cost of the same shall deemed to be included in the rate quoted for above item. (ii). Quoted rate is deemed to be inclusive of cost of demolition of old earthing as directed by Engr-in-Charge. (iii). The new earthing so constructed must have resisitance value below 2 ohms. If the aforesaid resistance value is not achieved contractor has to make proper additions/alterations to the newly constructed earthing at his own cost.
M&Lfor replacement test point terminal block made out of gun metal or phosphorus bronze size 75 x 75 x 25 mm thick drilled and screwed including 03 Nos 8 mm dia 25 mm long hexagonal head screws fixed to GI strip bracket fixed to porcelain/PVC insulators on wall complete all as specified and as directed.
Excavation in trenches in any type of soil not exc 1.5 m wide and not exc 1.5 m depth and getting out including forming bottom surfaces to required level or slope complete all as specified and as directed.
Returning filling in excavated soil including spreading, leveling, watering and well ramming, in layers not exceeding 25 cm thick complete all as specified and as directed.
Removal of surplus soil to a distance n exc in 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed.
S&F in repairs/replacement 40mm dia. GI pipe, light grade, burried in trenches/ as support / on walls / surface as earth continuity protection pipe for strip etc complete all as specified andas directed.
M& L for testing of lighting protection system & earthing (except new earthing ) at various locations in Tech Area in the presence of of Engineer -in -Charge by removing all earthing connections from the earth test points and measuring the resistance of earthing & lightning protection network using an earth tester (as approved by Engr-in-Charge) The test results of lightening protection and earthing shall be recorded during testing and the defective earthings & lightening protection systems shall be noted/recorded on test result sheet and shall be signed by JE, Enginer-in-charge and contrctor and kept on record . Items to be repaired/ to be renewed must be noted down during recording of test of earthing and lighting protection system complete all as specifiedsnd as directed. NOTE: (i) The earthing showing test result beyond 5 ohms are to be renewed and will be measured & paid for separately under relevant item of Sch 'A'. (ii). Meter for measuring the resistance of each earthing and conncted accessories will be arranged by the contractor.
S&F in replacemetof existing old any type of light fittings, LED Endura Well Glass light 40watt, pressure die cast aluminum housing, 240V, including necessary fittings with suitable in-built electronic driver complete all as directed and as specified and as directed. NOTE: - The cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections shall deemed to be included in the quoted rates.
HARISH SALES CORPORATION (BID ID -3347431)
Esha Engineers (BID ID -3356415)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .