| 1 | L1₹36,900Qualified Make: BPE
Model: BPE NIY 1 KVA 1000 VAH Online UPS ITX MF1101L3 30 Min 1 Yr AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE NIY 1 KVA 1000 VAH Online UPS ITX MF1101L3 30 Min 1 Yr | ₹36,900 | L1 | Qualified |
| 2 | L2₹39,210+₹2,310 (6.26%)Qualified Make: LUMINOUS
Model: Luminous LB1000UNO 1KVA UPS C 101 5 FIRST FLOOR TAGORE NAGAR RAIPUR CHHATTISGARH 492001 | RAIPUR | CHHATTISGARH | 492001 | Make: LUMINOUS
Model: Luminous LB1000UNO 1KVA UPS | ₹39,210+₹2,310 (6.26%) | L2 | Qualified |
| 3 | L3₹40,786+₹3,886 (10.5%)Qualified Make: microtek
Model: UPS 1000VA WITH INBUILT BATTERY 7AH 2NOS. MICROTEK TWINGUARD 1 B VASHISHT NAGER BABYAL ROAD NEAR HARYANA GRAMIN BANK AMBALA CANTT AMBALA HARYANA 133001 INDIA | AMBALA | HARYANA | 133001 | Make: microtek
Model: UPS 1000VA WITH INBUILT BATTERY 7AH 2NOS. MICROTEK TWINGUARD | ₹40,786+₹3,886 (10.5%) | L3 | Qualified |
| 4 | L4₹41,760+₹4,860 (13.2%)Qualified Make: MICROTEK ONLINE UPS
Model: MICROTEK TWIN GARD A 103 BHARAT NAGAR NEW FRIENDS COLONY NEW DELHI SOUTH DELHI DELHI 110025 | SOUTH EAST DELHI | DELHI | 110025 | Make: MICROTEK ONLINE UPS
Model: MICROTEK TWIN GARD | ₹41,760+₹4,860 (13.2%) | L4 | Qualified |
| 5 | Disqualified Make: better power
Model: Make: Better Power, Model: HR 1KVA30M_2 0 BETTER POWER SERVICES PVT LTD A K AZAD ROAD REHABARI KAMRUP ASSAM 781008 | KAMRUP METRO | ASSAM | 781008 | Make: better power
Model: Make: Better Power, Model: HR 1KVA30M_2 | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
28 Jul 2018, 4:00 pmClosed
Online UPS Online UPS ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 1.0 KVA As per GeM Catalogue. Technology IGBT-PWM without inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer
IGBT-PWM with inbuilt isolation transformer
IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave
50Hz single phase 160V - 260V sinewave
50Hz
Three phase 300 V - 450V sinewave
50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz
3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 15
30
60
90
120
180
2 40 Minimum VAH (VAH) 1000 Warranty for UPS (Years) 1 1
2
3
4
5 Movable trolly for Batteries Without With
Without
Without trollery but with rack 1/4 Warranty for battery 1 1
2 Degree of Protection IP21 IP21
IP20 Cabling 5 meters for input and out put Without With
Without Paralleling kit for synchronising Without With
Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Current Yes - Indicators for mains presence
Battery charging and discharging
Output Over Load
Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with Yes - 2/4 IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. 4465 - Type Test Certificate date 27/02/2014 - Name of Lab MICROTEK INTERNATINAL PVT LTD - Address of Lab MICROTEK
ROHTAK ROAD
NEW DELHI - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anshuman Das 181202
OFFICE OF COMMANDANT
49 ARMD REGT
JAURIAN
NEAR AKHNOOR
JAMMU AND KASHMIR 10 15
322095
GEM/2018/B/45677
Online UPS
15 days
Jammu And Kashmir; Jammu
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS Online UPS ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 1.0 KVA As per GeM Catalogue. Technology IGBT-PWM without inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz single phase 160V - 260V sinewave | - | - | - |
| 50Hz | - | - | - |
| Three phase 300 V - 450V sinewave | - | - | - |
| 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz | - | - | - |
| 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 15 | - | - | - |
| 30 | - | - | - |
| 60 | - | - | - |
| 90 | - | - | - |
| 120 | - | - | - |
| 180 | - | - | - |
| 2 40 Minimum VAH (VAH) 1000 Warranty for UPS (Years) 1 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 Movable trolly for Batteries Without With | - | - | - |
| Without | - | - | - |
| Without trollery but with rack 1/4 Warranty for battery 1 1 | - | - | - |
| 2 Degree of Protection IP21 IP21 | - | - | - |
| IP20 Cabling 5 meters for input and out put Without With | - | - | - |
| Without Paralleling kit for synchronising Without With | - | - | - |
| Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Yes - Indicators for mains presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with Yes - 2/4 IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. 4465 - Type Test Certificate date 27/02/2014 - Name of Lab MICROTEK INTERNATINAL PVT LTD - Address of Lab MICROTEK | - | - | - |
| ROHTAK ROAD | - | - | - |
| NEW DELHI - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anshuman Das 181202 | - | - | - |
| OFFICE OF COMMANDANT | - | - | - |
| 49 ARMD REGT | - | - | - |
| JAURIAN | - | - | - |
| NEAR AKHNOOR | - | - | - |
| JAMMU AND KASHMIR 10 15 | - | - | - |
Exempted
28 Jul 2018
11 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_322095.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .