Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.8 L+₹1.3 L (5.84%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹23.2 L+₹1.6 L (7.67%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹24.3 L+₹2.8 L (13.0%)Rejected-Finance | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹24.7 L+₹3.2 L (15.0%)Rejected-Finance | L5 | Rejected-Finance L1 being accepted |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
9 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 867 EWS
GE 867 EWS C/O 99 APO PIN 913867
REPAIR/MAINTENANCE OF SECURITY LIGHTS AT PEDONG, ALGARAH, DALAPCHAND, AP ALGARAH AND TEESTA TCP UNDER GE 867 EWS
2020_MES_376278_1
CA NO GE / 867 / TOKEN / 37 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Pedong
Refer tender documents
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹40,000
Yes
4 Nov 2020
10 Sept 2020
10 Oct 2020
10 Sept 2020
9 Oct 2020
3 Oct 2020
10 Sept 2020 - 18 Sept 2020
60 days
Amount
Taking down LED 150/120/100/90/80/60/45/30/25 watts energy efficient street light fitting, identifying the fault, repair / replacement of old unserviceable accessories with new accessories, re-assembling and make the street light fitting functional and re-fixing in existing location and connecting with three core copper PVC insulated conductor of 1 Sqmm size (nominal area) of suitable length to connect the luminaries to overhead conductor/existing lines complete all as specified and as directed. Note:- Spare parts and PVC cable for connection required for repair to street light fittings shall be measured and paid separately under relevant items as supply only.
Supply only three core copper PVC insulated PVC sheathed multi core cble with electrolytic grade annealed copper copper conductor suitable upto 1100V grade confirming to IS:694 conductor of 1 Sqmm size (nominal area) complete all as specified and directed by EIC. Make: Havells/Polycab/Finolex or equivalent as approved by GE.
Supply only in replacement of LED street light driver of 150 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMPTON/ or equivalent as approved by GE.
Supply only in replacement of LED street light driver of 120 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMPTON/ or equivalent as approved by GE.
Supply only in replacement of LED street light driver of 100 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMTON/ or equivalent as approved by GE.
Supply only in replacement of LED street light driver of 90 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMTON/ or equivalent as approved by GE.
Supply only in replacement of LED street light driver of 80 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMPTON/ or equivalent as approved by GE.
Supply only in replacement of LED street light driver of 60 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMPTON/ or a equivalent as approved by GE.
Supply only in replacement of LED street light driver of 45 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMTON/ or equivalent as approved by GE.
Supply only in replacement of LED street light driver of 30 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMPTON/ or equivalent as approved by GE.
Supply only in replacement of LED street light driver of 25 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMPTON/ or equivalent as approved by GE.
Taking down existing worn out GI brackets from pole and supply and fixing GI pipe bracket made out of 40mm dia GI pipe (light grade of length 1.5 meter) bent to the required shape for holding the fitting with proper angle including providing two pair of MS flat iron clamps of size 40mm x 6mm of required length duly drilled for bolt holes with required nuts, bolts and washers of suitable size, including applying two coats of aluminium paint over a coat of red oxide primer to clamps after perparation of surfaces complete all as specified and as directed. Make: TATA/JINDAL/ZENETH.
S & F MCCB four pole 63 Amp, 415 Volts, 'C' Curve, 25 KA breaking capacity, Ics=100% Icu including taking down existing MCCB complete all as specified and directed by Engr-in-Charge. Make: LEGRAND /SIEMENS/SCHNEIDER.
Material and labour for 40 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection or as in stand for post top lantern including taking down/out existing pipe complete all as specified and directed by Egineer-in-Charge. Make: TATA/ZENETH/JINDAL
Material and labour for taking down/up existing 40 mm dia bore GI tubing Light grade, and refixed/ laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection or as in stand for post top lantern complete all as specified and directed by Egineer-in-Charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge. Note:- Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately. Make of cable shall be CCI / Gloster / ICC / Unistar / NICCO / Asian (RPG) / Havells / Polycab/PRG/Universal/Plaza/Crystal cables/Terracom/ Rallison/Mescab/Jeypore/KEI
Taking out existing cable and relaying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core and connecting with necessary lugs complete all as specified and directed by Engineer-in-Charge. Note:- Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5 in depth for taking out /laying of cable etc., and getting out in soft/loose soil.complete all as specified and directed by Engineer-in-Charge.
Returning, filling in soil, including spreading leveling, watering and wall ramming in laying not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exe 50m and depositing where directed at alevel n.exe 1.5m above the starting point complete all as directed by Engineer - in -Charge.
Supply and spreading of dry sand in trenches for cable coushioning and punned down complete all as specified and directed by Engineer-in-Charge. Note:- Punned thickness only shall be measured for payment purpose.
M&L for common burnt bricks, sub class 'B', of size 250 x 125 x 75 mm laid in trenches for cable protection complete all as specified and directed by Engineer-in-charge.
Supply & fixing LED street Light in aluminum PDC housing toughened glass cover with IP 66 protection of 80 Watt including lamp fixed toexisting bracket including electrical connection complete with 2 runs of 2.5 Sqmm single core copper cable ISI marked stranded to LT terminal box to fitting complete including taking down existing fitting all as specified and as directed. Make: SURYA cat part No. SLE UL 80W IP66 LXN or equivalent make of Havells/Philips/CG as approved by GE.
S&F 3 Phase automatic streeet light switch using infrared sensor based nature swich the following features including taking down existing switch compete all as specified and directed. (a) Automatic switching on at dusk (30lux),Automatic switching off at dawn(10 lux) (b) No time setting or sesonal resetting or longitude -latitude setting (c) Over voltage and low voltage trip with auto reset. (d) The sensor(Nature switch ) along with suitable power contactors and input out put MCBsshould be enclosed in pole/wall mountable enclosure made of rust proof,shock proof, termite proof and FR grade SMC material(Sintex make or equivalent) and conforming to IP-66. (e) The contactors,MCBs and circuit wiring(minimum 16 sq mm) should be suitable enough to take 3-phase load of 8-KW/32 Amps per phase) Model : Swadeep-66-8kW3P(Nature switch/Sensor-Kakatiya/Bajaj/Healer.Contactors-BCH/L&T/Schneider.MCBs-Hager/Schneider/L&T, Circuit wiring -Poly cab/Finolex or equivalent) or equivalent model of Bajaj/Havells approved by GE.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge. Note:- Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately. Make of cable shall be CCI / Gloster / ICC / Unistar / NICCO / Asian (RPG) / Havells / Polycab/PRG/Universal/Plaza/Crystal cables/Terracom/ Rallison/Mescab/Jeypore/KEI
Sub Total of Schedule 'A'
Schedule of Credit (Minus) Rs. 35,360.00 B/F from Ser page No. 26 NOTE: Bidder shall insert credit amount as rate Rs. 35,360.00 in Green field under Col-M. If bidder does not insert the amount the same will be deducted from total amount of Schedule 'A' and accordingly total amount of tender will be considered in deciding the lowest tender.
Sub Total of Schedule of Credit
PRASAD PRADHAN AND SON
SANJAY MITTAL
MS MAYA PRAKASH GOEL AND SONS
GEETA CONSTRUCTION
C. M. AGARWAL AND CO
MS BRAHMA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .