Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹19.5 L+₹1.2 L (6.36%)Rejected-Finance NOT AVAILABLE | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹19.5 L+₹1.2 L (6.41%)Rejected-Finance BAM GAON SILAPATHAR DIST DHEMAJI ASSAM | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹19.9 L+₹1.5 L (8.44%)Rejected-Finance NOT AVAILABLE | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹20.7 L+₹2.4 L (13.2%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹21.5 L
EMD Value
₹43,000
Closing Date
4 Aug 2020, 6:00 pmClosed
MAJ JYOTI PRAKASH SAHOO
GE 872 EWS C/O 99 APO
SPECIAL REPAIRS TO BLDG No. OWT-08 (MT OFFICE), OWT-16 (SM AND DSC OFFICE) AND OWT-18 (RATION STORE) OF DOU AND SPECIAL REPAIRS TO BLDG No. T-17 (JCOS AND ORS LIVING) OF SUTC AT LIKABALI MIL STN UNDER GE 872 EWS (8714/T-14/E8)
2020_MES_356231_1
8814/T-14/E8
Open Tender
Civil Works
Item Rate
183 days
LIKABALI
As per tender documents
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹43,000
Yes
7 Sept 2020
26 Jun 2020
5 Aug 2020
26 Jun 2020
4 Aug 2020
10 Jul 2020
26 Jun 2020 - 30 Jun 2020
Amount
B/R SERVICES/WORKS
Demolition Cement Concrete (un-reinforced) of any description in Ground Floors, Pavings, etc. not exc. 150mm thickness (above or below Ground Level) and removing debris, etc. to a distance not exc. 100.00 Metre, complete all as specified and as directed.
Demolition Brick Work or Pre-cast Concrete Masonry, built in Cement Mortar and in any Position including all Quoins, Arches and Pillars, etc., complete all as specified and as directed.
Dismantling Timber Scantling 40 Sq Cm and Over in Section in Unframed Work, complete all as specified and as directed.
Dismantling Timber Fillets, Rails, Posts, Rafters, Purlins, etc. Under 40 Sq Cm in Section in Unframed Work, complete all as specified and as directed.
Taking down Chowkat or Frame of any description (without Taking Off Shutter from the Frame) not exc. 1.50 Square Metre Each, complete all as specified and as directed.
Taking down Chowkat or Frame of any description (without Taking Off Shutter from the Frame), exc. 1.50 Square Metre but not exc. 4.00 Square Metre Each, complete all as specified and as directed.
Taking down Shutter of any description, exc. 1.00 Square Metre but not exc. 2.00 Square Metre Each, complete all as specified and as directed.
Dismantling Plain or Corrugated Steel Sheeting of any gauge and thickness, complete all as specified and as directed.
Dismantling Wall and Ceiling Boards (Fibre, Pulp, Insulation, etc.) or Insulation Boards/ Slabs/ Blankets of any descriptions including Cover Fillets, complete all as specified and as as directed.
Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing) and removing debris, etc. to a distance not exc. 100.00 Metre, complete all as specified and as directed.
Taking down Cement Plaster including raking out Joints, hacking for Key, scrubbing down with Water and removing Debris, etc. etc. to a distance not exc. 100.00 Metre, complete all as specified and as directed.
Taking out Broken Glass of any description from Wooden or Metal Frames, or Stone, Concrete or Brick surrounds of any thickness or size; Hacking out Old Putty or Removing Beads, etc., complete all as specified and as directed.
M&L Brick Work Half Brick thick with Sub-Class ‘B’ Bricks (Old Size Bricks), Straight or Curved on Plan to any Radius, built in Cement Mortar 1:4, complete all as specified and as directed.
M&L Cutting Holes in Brick Walls, not exc. Half Brick thick, built in Cement Mortar for inserting of Holdfasts, Lugs, etc. and Making Good to Dismantled Portion with Cement Concrete 1:2:4 (20mm graded stone aggregate) or Cement Mortar 1:3 (as required) and adjoining Surfaces in Cement Mortar 1:4, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) in Scantling, Cleansawn, Timber fixed (Unframed work), fixing with Nails, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) Plain Fillets, Cleansawn, Square, Rectangular or Triangular in Section, exc. 13.00 Sq Cm but not exc, 25.00 Sq Cm, fixed with Nails, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned), Plain Fillets, Wrought, Square, Rectangular or Triangular in Section, exc. 6.00 Sq Cm but not exc, 13.00 Sq Cm, fixed with Nails, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) Plain, Solid, Straight, Chowkats and Frame, Wrought, Framed rebated on the Solid, Rounded or Chamfered, put together with Glue pinned at Joints, complete all as specified and as directed.
M&L Taking down Chowkat or Frame of any description, not exc. 1.50 Square Metre Each and Refixing in the Same Opeing, complete all as specified and as directed.
M&L Taking down Chowkat or Frame of any description, exc. 1.50 Square Metre but not exc. 4.00 Square Metre Each and Refixing in the Same Opeing, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) Glazed and Skeleton Shutter 35mm thick, Open rebated and prepared to receive Glass, Gauze, etc. (without Sash Bars), Edges of Framing plain, chamfered or rounded. fitted with cut and mitred Beads for securing glass, etc.; sizes of Members of Shutters as specified in SSR Part I, Section 8, Clause 8.24(a) and fitted to Chowkat, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) Glazed and Skeleton Shutter 30mm thick, prepared to receive Gauge/Glass (without Sash Bars) fixed with mitred beeds supplied and fitted to Chowkat and securing Glass, Gauge, etc. sizes of Members of Shutter as specified in SSR Part-I, Section 8, Clause 8.24(b) and fitted to Chowkat, complete all as specified and as directed.
S&F Flush Shutter 35mm thick, Solid Core Construction, with Block Board Core and Plywood Face Panels, Commercial type on Both Sides including Teakwood Lipping 6.0mm thick, fixed with Nails, complete all as specified and as directed.
M&L Refixing Shutter of any description in Same Opening, exc. 1.00 Square Metre but not exc. 2.00 Square Metre Each including necessary Resecuring, or Easing & Adjusting, etc., complete all as specified and as directed.
M&L Refixing Shutter of any description in Same Opening, exc. 1.00 Square Metre but not exc. 2.00 Square Metre Each including necessary Resecuring, or Easing & Adjusting, etc., complete all as specified and as directed.
S&F Steel Ventilator with Centre Hung Shutter including Two Pairs of Brass Cup Pivots, Catch Spring and Pully Wheel, complete all as specified and as directed.
M&L Mild Steel Bands, Straps, Supports or Stays for Rainwater, Ventilating Pipes including Bolts, Hooks (Stay) for large Gates; Hook and Pintle Hinges: large Hasps and Staples; Hand Made Sliding Bolts; Clamps; Holdfasts; Wall Ties and similar small Articles conforming to Fe-290 Gde-E-165, complete all as specified and as as directed.
S&F Aluminium anodised Barrel Tower Bolt, 125mm long, Extruded Section, complete all as specified and as directed.
S&F Aluminium anodised Barrel Tower Bolt, 150mm long, Extruded Section, complete all as specified and as directed.
S&F Aluminium alloy, anodised, Sliding Door Bolt 300mm long with Hasp, Staple (Bolt type) and Fixing Clips of Sheet, Cast or Extruded Sections and Fixing Bolts and Sliding Bolts of Extruded Sections or Cast-Aluminium alloy and fixed, complete all as specified and as directed.
S&F Mild Steel Butt Hinge 75mm in size, medium weight, Cold Rolled, complete all as specified and as directed.
S&F Mild Steel Butt Hinge 100mm in size, medium weight, Cold Rolled, complete all as specified and as directed.
S&F Aluminium Handle 125mm, anodised, Extruded Sections, Fabricated type, complete all as specified and as directed.
S&F Aluminium Handle 150mm, anodised, Extruded Sections, Fabricated type, complete all as specified and as directed.
S&F Mild Steel 300mm, Ordinary Rat Tail Rod pattern Springs including Roller and Roller Plate, complete all as specified and as directed.
S&F Floor Door Stopper having Overall length of Cover Plate 150mm of Aluminium Alloy Body and Tongue, anodised, with Hard Drawn Steel Spring, fixed in Floor, complete all as specified and as directed.
S&F Curtain Rails (Harrison Rails) Aluminium anodised 24mm Outer dia, fixing with and including Brackets, Stops, Rollers, Side Holders, etc, and Fixed-in-repairs, complete all as specified and as directed.
M&L Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staples, complete all as specified and as directed
M&L Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staples and Fixing-in-repairs, complete all as specified and as directed
S&F Sheet Glass 3.0mm thick, Plain, Ordinary quality and Glazing with Oil Putty in Square not exc. 0.50 Sqm in Each Pane, complete all as specified and as directed.
S&F Pre-painted Galvalume Aluminum Zinc Coating GI based Corrugated Steel Sheet 0.50mm thick Coloured, having Tensile Strength of 550 Mpa in Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed.
M&L Fixing only Pre-painted Galvalume Aluminum Zinc Coating GI based Corrugated Steel Sheet 0.50mm thick Coloured (Serviceable Galvalume Sheets obtained from Item No. 1.08 here-in-before) in Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed.
S&F Pre-painted Galvalume Aluminum Zinc Coating GI based Plain Steel Sheet 0.50mm thick Coloured, having Tensile Strength of 550 Mpa in Ridges/ Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed.
M&L Aluminum anodised Powder Coated Snap Grid Frame Work of size 605x605mm in False Ceiling with and including Hangers 4.0mm dia GI (upto 1200mm length) for adjusting Level, fixed to Roof Slabs by means of Ceilling Cleats made out of GI Flat 40x3.0mm in size, 60mm long and Expansion Hold Fasteners 12.5mm dia, 40mm long, complete all as specified and as directed.
M&L Galvanised Powder Coated Snap Grid Frame Work of size 605x605mm in False Ceiling with and including Hangers 4.0mm dia GI (upto 1200mm length) for adjusting Level, fixed to Roof Slabs by means of Ceilling Cleats made out of GI Flat 40x3.0mm in size, 60mm long and Expansion Hold Fasteners 12.5mm dia, 40mm long, complete all as specified and as directed.
S&F HSPC Non-Asbestos Fibre Cement Building Boards 4.0mm thick, Pre-primed, Self Embossed, Textured Designer Boards, Water Resistant, Termite Resistant, Fire Resistant for insulation, fixed or laid/ inserted to Aluminum Snap Grid Frame Work with Screws, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (20mm graded stone aggregate) 75mm thick in Plinth Protection, etc., Laid in Alternate Panels, finished Concrete Surfaces Even and Smoooth without Using Extra Cement, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (12.5mm graded stone aggregate) 25mm thick in Sub-base for laying of Tiles, etc., finished Concrete Surfaces Fair and Even, complete all as specified and as directed.
M&L Non-skid Ceramic Coloured/Designer Tiles 7.0mm to 8.0mm thick (square/ rectangular) area of Each Tile exc. 0.18 Sqm but not exc. 0.38 Sqm (1st quality) in Floors, Jointed in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, laid over and including Screed or Screed Bed 15mm thick in Cement Mortar 1:6, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed will deem to include in Quoted Unit Rate.
M&L Non-Skid Ceramic Coloured/Designer Tiles 7.0mm to 8.0mm thick (square/ rectangular) area of Each Tile exc. 0.11 Sqm but not exc. 0.18 Sqm (1st quality) in Floors, Jointed in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, laid over and including Screed or Screed Bed 15mm thick in Cement Mortar 1:6, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed will deem to include in Quoted Unit Rate.
M&L Non-Skid Ceramic Coloured/Designer Tiles 7.0mm to 8.0mm thick (square/ rectangular), area of Each Tile exc. 0.11 Sqm but not exc. 0.18 Sqm (1st quality) in Vertical Surfaces i.e. Dado, Skirting, etc., set in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, fixing over and including Screed or Screed Bed 10mm thick in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed will deem to include in Quoted Unit Rate.
M&L Rendering (Internal) 15mm thick in Cement Mortar 1:6 on Brick/ PCC Blocks or Concrete Works, finished Plastered Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed.
M&L Rendering (External) 15mm thick in Cement Mortar 1:4 on Brick/PCC Blocks or Concrete Works including mixed with WPC, finished Fair and Even, complete all as specified and as directed. NOTE : Water Proofing Compound (WPC) will be Measured and Paid saperately under appropriate Item.
Supply only Water Proofing Compound (as approved), conforming to IS:2645-2003, complete all as specified and as directed.
M&L Preparing Newly Plastered Surfaces of Walls and applying Three Coats of White Wash, complete all as specified and as directed.
M&L Preparing Old treated Plastered Surfaces of Walls and applying One Coat of White Wash, complete all as specified and as directed.
M&L Preparing New Plastered Surfaces of Walls and applying Two Coats of Distemper Oil Emulsion (as approved Tint) over a Coat of Chalk Whitening (Priming Coat), complete all as specified and as directed.
M&L Preparing Old Treated Plastered Surfaces of Walls and applying Two Coats of Distemper Oil Emulsion (as approved Tint), complete all as specified and as directed.
M&L Preparing Surfaces by Complete Removal of Existing Surfaces Treatment on Walls and applying Two Coats of Distemper Oil Emulsion (as approved Tint), complete all as specified and as directed.
M&L Preparing Newly Plastered Surfaces of Walls and applying Two Coats of Cement Based Paint (as approved Tint) over a coat of Alkali Resistant Priming Paint, complete all as specified and as directed.
M&L Preparing Surfaces by Complete Removal of Existing Treatment on Walls and applying Two Coats of Cement Based Paint (as approved Tint), complete all as specified and as directed.
M&L Preparing New Wooden Surfaces of any description, over 10 Cm in Width or Girth and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of as approved Tint) over a Coat of Pink Primer, complete all as specified and as directed.
M&L Preparing Old Painted Wooden Surfaces of any description, over 10 Cm in Width or Girth and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of as approved Tint), complete all as specified and as directed.
M&L Preparing Old Painted Wooden Surfaces of any description, over 10 Cm in Width or Girth and applying One Coat of Synthetic Enamel Paint (1st quality/ grade Paint of as approved Tint), complete all as specified and as directed.
M&L Preparing New Wooden Surfaces of any description, not exc. 10 Cm in Width or Girth when unconnected with other Painting or when Painted in different Tint and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of as approved Tint) over a Coat of Pink Primer, complete all as specified and as directed.
M&L preparing New or Previously Treated Surface of Wood and Wood based Materials of any description and girth and treated with Two Coats of Creosote Oil, complete all as specified and as directed.
M&L Preparing previously Untreated Surfaces of Wood and Wood Based Materials, of any description and girth not otherwise described and treating with Tar or Coal Tar Black Paint to Backs of Chowkats, etc. Area tarred exc. 0.10 Sqm but not exc. 0.50 Sqm Each including Sanding with Clean Sharp Sand after tarred, complete all as specified and as directed.
M&L Preparing previously Untreated Surfaces of any description and girth not otherwise described and treating with Tar or Coal Tar Black Paint to Holdfast or similar Small Items, Area tarred not exc. 0.10 Sqm Each including Sanding with Clean Sharp Sand after tarred, complete all as specified and as directed.
E/M SERVICES/WORKS
M&L Taking down carefully Copper/Aluminium Point Wiring (Light, Fan, Socket or Power) complete from in any position including Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fittings, etc., Making Good disturbed surfaces of Walls/ Ceillings, etc. in Cement Mortar 1:3 including providing Surface Treatment (Colour Washing/ Distempering/ Painting) wherever required to match the Existing Finishes, complete all as specified and as directed.
M&L Taking down/out unserviceable Sub-main Wiring from Batten/ Conduit/ PVC Casing Capping of any description, Making Good disturbed surfaces of Walls/ Ceillings, etc. in Cement Mortar 1:3 including providing Surface Treatment (Colour Washing/ Distempering/ Painting) wherever required to match the Existing Finishes, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/ FAN POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3/5 PIN SOCKET OUTLET 6 AMP POINT on INDEPENDENT BOARD, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire for ONE 3/5 PIN SOCKET 6 AMP POINT on SAME BOARD, complete all as specified and as directed.
M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3/5 PIN SOCKET OUTLET 6/16 AMP POINT on INDEPENDENT BOARD, complete all as specified and as directed.
M&L Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc., complete all as specified and as directed. NOTE :- (a) Cost of 3-Runs of Cables & 1-Run of PVC Casing Capping shall deem to be include in the Quoted Unit Rate and the same will be Mesured as ONE UNIT. (b) Sub-main Wiring will be measured PVC Casing Capping only. Wires required for looping, etc. as ordered will deem to be include in the Quoted UNIT RATE.
S&F PVC Casing Capping (ISI Marked) of size 25mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc., including Taking down/ out unserviceable PVC Casing Capping, complete all as specified and as directed.
S&F PVC Rectangular Block of size 100x100x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed.
S&F Switch Piano 6 Amp, Single Pole, Flush type, 1-way, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Socket Outlet 6 Amp, 3 Pin, 2-in-1, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Switch Socket Combination 6 Amp, 3 Pin, 2-in-1, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Switch Socket Combination 6/16 Amp, 3 Pin, 2-in-1, Multi Plug, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Lamp Holder PVC/ Polycarbonate type with Back Plate suitable for Batten Fitting and connecting up, complete all as specified and as directed.
S&F Ceiling Rose 65x50mm, 3 Terminals, Surface Bakelite suitable for 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Ceiling Fan Regulator, Dimmer Switch type, 230 Volt AC, Rotary Stepped Electronic, 120/280 Volt including necessary Connection and connecting up, complete all as specified and as directed.
S&F LED Lamp 7 Watt, 230 Volt (as approved) including Taking down unserviceable Lamp of any description, complete all as specified and as directed. MAKE : HAVELS, MODEL : LED ADORE 7 W E27 WW Ball Lamp or equivalent in Make : BAJAJ/ CG/ C&S/ PHILIPS (as approved by GE).
S&F LED Bulk Head e-TATRA Series Light Fitting 1x6.0 Watt having Plastic Housing with Clear Prismatic Diffuser LED 6.0 Watt Lamp and connecting up with and including suitable size Twisted Flexible Copper Conductor Cable including Taking down unserviceable Light Fitting of any description, complete all as specified and as directed. MAKE : C&S E-TARTA Series 6W or equivalent in Make : BAJAJ/ CG/ HAVELS/ PHILIPS (as approved by GE).
S&F LED Decorative Wall Light Fixture 1x10 Watt made of Polycarbonate with LED 10 Watt Bulb and connecting up with and including suitable size Twisted Flexible Copper Conductor Cable including Taking down unserviceable Light Fitting of any description, complete all as specified and as directed. MAKE : BAJAJ/ CG/ C&S/ HAVELS/ PHILIPS (as approved by GE)
S&F LED Integrated Batten T-5 Tube Light Fitting 1x20 Watt with LED 20 Watt and connecting up with and including suitable size Twisted Flexible Copper Conductor Cable including Taking down unserviceable Light Fitting of any description, complete all as specified and as directed. MAKE : HAVELS E-LITE PRIDE PLUS 20W or equivalent in Make : BAJAJ/ CG/ C&S/ PHILIPS (as approved by GE).
M&L Taking down Ceiling Fan, Exhaust Fan of any Make, Size after disconnecting and Keep in Safe Custody for Re-hanging/ Re-fixing, complete all as specified and as directed.
M&L Preparing Old Painted Surfaces of Fan including Cleaning, Washing, Rubbing and Filling Cavities with Filler, applying One Coat of Synthetic Enamelled Paint (as approved) with Spray Painting Machine and Writing MES No. with Black Paint, complete all as specified and as directed.
M&L Hanging/Fixing only Ceiling Fan, Exhaust Fan and connecting with and including suitable size Copper Conductor Cable from Ceiling Rose to Connector of the Fan, complete all as specified and as directed.
S&F MCB Single Pole 6 Amp to 32 Amp, 'C' Series, 50 Hz, 10 kA, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F MCB Single Pole & Neutral 6 Amp to 32 Amp, 'C' Series, 50 Hz, 10 kA, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F MCB Single Pole & Neutral 40 Amp, 'C' Series, 50 Hz, 10 kA, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F MCB Distribution Board Sheet Metal Enclosure, Single Door with Steel Phosphotised Powder painted, SPN, 4-way, 240 Volt with 200 Amp rated Neutral Bars & Earth Bar and connecting up including Taking down/out unserviceable MCB DB, complete all as specified and as directed. MAKE : HAVELS, Cat No. DHDPSHOSRW04 or equivalent in LEGRAND/ L&T/ SCHNEIDER (as approved by GE)
S&F MCB Distribution Board Sheet Metal Enclosure, Single Door with Steel Phosphotised Powder painted, SPN, 8-way, 240 Volt with 200 Amp rated Neutral Bars & Earth Bar and connecting up including Taking down/out unserviceable MCB DB, complete all as specified and as directed. MAKE : HAVELS, Cat No. DHDPSHOSRW08 or equivalent in LEGRAND/ L&T/ SCHNEIDER (as approved by GE)
Supply & Laying or Passing through Pipe 1100 Volt grade heavy duty, Cross-sectional area 10 Sqmm, 2 Core, Flat or Circular Cable with PVC insulated Aluminium Conductor served with an inner sheathing of PVC Tape armoured with Galvanised Steel Wire or Tape and Overall PVC sheathed in Service Connection suspended by insulating Hangers not more than 1.0 Metre apart including 4.0mm Suspension Wire including Taking down/ out Unserviceable Service Connection, complete all as specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing including Taking down/out unserviceable Earthing of any description, complete all as specified and as directed.
B S ENTERPRISE
M/S Raju prasad
SHRI MANOJ KONWAR
D. D. Construction
LALIT DOLEY
M H KHAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .