ELV work in Construction of CTO Building (RHS Part) under Construction of Mini Secretariat at Sri Ganganagar
2026_RSRDC_536289_1
RSRDC NIT No. 688/2025-26 Dated 06.02.2026 Sl No 03
Open Tender
Civil Works - Water Works
240 days
Construction of Mini Secretariat at Sri Ganganagar
PLEASE REFER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹1,180
PD RSRDC ELECT II JAIPUR THROUGH NEFT/RTGS/IMPS
₹1.6 L
6 Mar 2026
9 Feb 2026
19 Feb 2026
9 Feb 2026
18 Feb 2026
10 Feb 2026
Local Area Networking
S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required.
S&F following sizes of ISI marked ( IS:14927 P - II ) uPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners etc. as required.
32 mm x 12 mm
100 mm x 50 mm
Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, U/UTP (Unscreened/Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by LSZH Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies ranging from 250 to 500 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect.
Supply and Installation of unshielded/360 degree shielded PCB based Information outlets made of high impact plastic body with ABS, Flammability rating UL 94 V-0 with provision for protection against dust in jack or Faceplate, suitable for Cat 6/6A application complying to latest amendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat 6/6A standards at frequencies 250/ 500 MHz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have toolless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA 568 C.2 & ISO/IEC 11801 or latest standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocol (VOIP) Specifications in existing modular/MS Boxes along with necessary connections as required. All as per pre approved by Engineer in charge.
Cat 6, Un-sheilded Information Outlet
Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture with dust cover, material should be High-impact, flame retardant, thermoplastic, UL listed material, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge.
Single Aperture
Supply, Installation, Testing and Commissioning of Rack mounted 19" 1U, 24 Port loaded, CRS chasis, powder coated, sheet steel, High-impact, flame retardant, thermoplastic, UL Listed, Modular Patch Panels with Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required. All as per pre approved by Engineer in charge.
Modular Patch Panel Loaded with Cat -6 I/O
Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).
Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord
Supply, Drawing and OLTS Testing, of OM2 Multi mode (50/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.651 with outer sheath, cable should be used for LAN and WAN back bones, for indoor/outdoor installations these sheathed cable be placed in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect.
6 fiber
12 Fiber
Supply, Installation, OTDR/OLTS Testing & Fusion Splicing of Fiber OM2 Multimode Pigtail (50/125 µm) made of glass fiber optic, should be fitted at one end with any one type of single SC/LC/SN/CS type connector in acc., as per latest ammendments of TIA/EIA 569 Standard Specification as per requirments complete in all respect.
Supply, Installation, & Testing of Indoor duplex OM2 Multimode patch cord (50/125 µm made of glass fiber optic with LSZH jacket, 2.0x4.1 mm, Multimode ITU G 651 Mounted on both sides with SC/LC/SN/CS type Duplex connectors in acc. with IEC 61754-20. Zirconia (ceramic) ferrule with a PC polished endface geometry, connectors should be tuned in accordance with IEC 61755-3-1 and qualified in acc. with IEC 61753-1 for category U (uncontrolled environment, duplex clip and white plastic dust cover, should comply to delta IL < 0.2 dB after 500 mating cycles, there should be an optional Visual coding, mechanical coding and lock protection on the patch cords which can be added on later stage. patch cords's performance should be acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, as per requirements.
Supply, Installation, & Testing of 19" 1U Rack Mounted/ surface mounted aluminum/ CRCA powder coated, OM2 multimode glass Fiber Optic Cable Patch panel/LIU loaded with flangeless/screwable adapters for SC/LC/SN/CS type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleeves, screws, nuts to install the panel for rackmount applications as per requirement. All as per pre approved by Engineer in charge.
Multi Mode LIU 12 Ports
Multi Mode LIU 24 Ports
Supply, Installation, OTDR / OLTS Testing & Fusion Splicing of Fiber Singlemode Pigtail (9/125 µm (OS2) made of glass fiber optic, with semi-tight buffer PA/PBT, Ø 0.9 mm, yellow, singlemode G652.D (9/125 µm (OS2), should have length of min 1.5m, should be fitted at one end with any one type of single SC/LC/SN/CS type connector in acc. with IEC 61754-20, Should be delta IL < 0.2 dB after 500 mating cycles, It should be Zirconia (ceramic) ferrule with a PC polished endface geometry connector qualified in acc. with IEC 61753-1 for category U (uncontrolled environment). and qualified in acc. with IEC 61753-1, Performance acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, Standard Specification as per requirements.
Supply, Installation, & Testing of Indoor duplex Singlemode patch cord (9/125 µm (OS2) made of glass fiber optic with LSZH jacket, F8 2.0x4.1 mm, yellow, singlemode G652.D (9/125 µm (OS2) Mounted on both sides with SC/LC/SN/CS type Duplex connectors in acc. with IEC 61754-20. Zirconia (ceramic) ferrule with a PC polished endface geometry, connectors should be tuned in accordance with IEC 61755-3-1 and qualified in acc. with IEC 61753-1 for category U (uncontrolled environment, duplex clip and white plastic dust cover, should comply to delta IL < 0.2 dB after 500 mating cycles, there should be an optional Visual coding, mechanical coding and lock protection on the patch cords which can be added on later stage. patch cords's performance should be acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, as per requirements.
Single Mode Patch Cord 1 Mtr.
Single Mode Patch Cord 2 Mtr.
Supply, Installation, & Testing of 19" 1U Rack Mounted/ surface mounted aluminum/ CRCA powder coated, OS2 Single mode glass Fiber Optic Cable Patch panel/LIU loaded with flangeless/screwable duplex adapters for SC/LC/SN/CS type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleeves, screws, nuts to install the panel for rackmount applications as per requirement complete in all respect. All as per pre approved by Engineer in charge.
12 Ports
24 Ports
Supply & Installation of IP-20 & IK-08 , Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19" angles with wall mounting provision on wall. Accessories like: 1 No of 19" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.
12 U Rack with Width 600 mm & Depth 400 mm + 100 mm
15 U Rack with Width 600 mm & Depth 400 mm + 100 mm
Supply & Installation of IP-20 & IK-08 , Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet,Vertical Mounting Rail 1.6 MM with 'U'Marking, front sturdy sheet steel frame folded from one piece and welded with 5mm toughened glass door, with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, Set of 75 mm height 4 castors, 2 of which have brakes, Accessories like: 5 Nos of 19" 1U Horizontal Cable manager, 2 Nos of vertical cable managers, 1 no. Keyboard Tray, 4 Nos of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 2 No of 19" 1U, mountable socket strips with 6 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable complete in all respect.
42 U Rack with Width 600 mm & Depth 800 mm
Supplying, installation, Testing and commissioning of following capacity 24 port Non POE Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snooping V1/V2. IGMP / MLD Groups 1K or more, IPv4 / IPv6 Loopback Interface , 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.0Ǫ, Port based, Ǫ-in-Ǫ , Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snooping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.0P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.0p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.0ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
Supplying, installation, Testing and commissioning of following capacity 24 port POE Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snooping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.0Ǫ, Port based , Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snooping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.0P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.0p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.0ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required.(For Each SM Fiber) all switches & related Fiber modules should be of same make & category for seamless integration with each other of Enterprise class.
1G SFP Single Mode/Multi Mode
10 G SFP + Single Mode/Multi Mode
Supply, installation, Testing and Commissioning of 1000 base-LX/LH single mode/Multi mode fibre to 1000 base-T copper giga bit , Media Convertor complete as required complete in all respect.
Fiber Fusion Splicing with OTDR/OLTS Testing of Fiber Single/ Multi mode (per splice) of glass Fiber Optic Cable including jointer box and cleaning the cable and making splice as per standard practice complete in all respect.
CCTV Survelience system
SITC of IP Based 2MP Dome camera: 1/2.8" or larger Progressive Scan CMOS Sensor with resolution: (1920 x 1080) @30 fps with a varifocal 2.8mm to 12mm lens or better. Should Support H.264, H.265, MJPEG, Quad/Triple streaming profiles, Frame rate upto 1-30 fps, IR Range - 40mtr or higher, 120dB WDR, 2DNR/3DNR, BLC. Camera should support Open standard to support ONVIF (PROFILE S, PROFILE G, PROFILE T), 1/1 Audio In/Out or better and 1/1 Alarm In/Out or better, onboard storage upto 512GB (SD card not included). The camera supports advanced Video Analytics (VA) including motion detection and alarm should be trigger on Tampering, Network disconnect, IP address conflict. CCTV should have password protection, privacy mask, IP address filtering, Metal Housing, Vandal-proof housing, IP67, IK10, DC 12V & PoE, Complete with Junction box for cable management. Operating Conditions within -20°C to 60°C or better. The MAC address of Camera/NVR must be registered in the name of OEM. Regulatory approvals include FCC, BIS/UL, CE. CCTV cameras must be BIS Registered Cyber Security Certified by STQC as per IoTSCS and meet the Essential Requirement (ER) issued by MeitY for security. The CCTV OEM should have its service/ support center in Rajasthan.
SITC of IP Based 2MP Bullet camera: 1/2.8" or larger Progressive Scan CMOS Sensor with resolution: (1920 x 1080) @30 fps with a varifocal 2.8mm to 12mm lens or better. Should Support H.264, H.265, MJPEG, Quad/Triple streaming profiles, Frame rate upto 1-30 fps, IR Range - 50mtr or higher, 120dB WDR, 2DNR/3DNR, BLC. Camera should support Open standard to support ONVIF (PROFILE S, PROFILE G, PROFILE T), 1/1 Audio In/Out or better and 1/1 Alarm In/Out or better, onboard storage upto 512GB (SD card not included). The camera supports advanced Video Analytics (VA) including motion detection and alarm should be trigger on Tampering, Network disconnect, IP address conflict. CCTV should have password protection, privacy mask, IP address filtering, Metal Housing, Vandal-proof housing, IP67, IK10, DC 12V & PoE, Complete with Junction box for cable management. Operating Conditions within -20°C to 60°C or better. The MAC address of Camera/NVR must be registered in the name of OEM. Regulatory approvals include FCC, BIS/UL, CE. CCTV cameras must be BIS Registered Cyber Security Certified by STQC as per IoTSCS and meet the Essential Requirement (ER) issued by MeitY for security. The CCTV OEM should have service/ support center in Rajasthan.
SITC of 64CH NVR for 2/5 MP cameras with minimum 8 SATA HDD Support with minimum 80 TB capacity (minimum 10TB Capacity per slot - Hard Disk Not Included), minimum 1 HDMI output port, Video comression - H.265/H.264/JPEG, 1/1 Audio In/Out, Preview Capability - Upto 4K, Playback: 16-channel simultaneously. NVR should support minimum 512 Mbps throughput bandwidth (256 incoming bandwidth), ONVIF compliance (Profile S/G/T). Recording resolution up to 4K/8MP, minimum 2 USB Ports, minimum 1 Ethernet Ports (RJ-45) 10/100/1000Mbps, RAID 0/1/5/10 or better. The system shall operate in 0°C to +50°C or better with BIS, FCC, CE. The CCTV OEM should have its service/ support center in Rajasthan.
SITC of 3.5" 4TB internal HDD for cctv recording ,capable for 24x7 operation, hdd rpm capacity shoud be 7200 rpm or better, Buffer should be 512 MB as required of following size.
SITC of following diagonal size professional Display, 4k Resolution, Brightness(Typ.) 440 nit and above , Contrast Ratio-2000:1 and above, Viewing Angle(H/V)-178/178, Response Time(G-to-G) 8ms, Input: RGB- Analog D-SUB, Video- HDMI 2.0 (2), HDCP- HDCP 2.2, Audio- Stereo mini Jack, USB- Only F/W upgrade, Outputs: RGB- DP1.2(Loop- out), Audio- Stereo mini Jack, External Control- RS232C(in/out), RJ45, External Sensor Detachable type(IR Ambient). Operation Hour 24/7. mounting bracket etc. as required.
SITC of IP-PBX which is IP at its core and act as a Unified Communication System with IP switching technology and 100% non-blocking, configured for below mentioned. The system should be IPV6 ready, should have VoIP and Voice mail at its core i.e. these modules should be mountable on the CPU. The system should be Q Sig Ready, inbuilt Auto-attendant facility, Returned Call to Original Caller (RCOC), CLI based DISA (Mobile Extension)System, Should support SNMP manager for managing and monitor network elements, audit network usage and detect network faults, should support SIP over TLS and SRTP, minimum 2 Gigabit Ethernet ports for LAN and WAN, built-in multi-party conferencing facility with 21 party in a single conference, minimum one RS232 ports for SMDR/PMS/CAS Interface. The System have have capability to also act like Universal Media Gateway when required. The System should have facility of Conversation recording on Analog/Digital/IP ports as well as on Mobile SIP Smartphones, UC Client application for Android, iPhone and on Windows PC. Power supply should be inbuilt and SMPS type with input ranges from 100 – 240 V AC, 47-60 Hz OR 48VDC +/- 15%. The system must have Certification: TEC, CE, FCC, ROHS.
192 analogue extensions, 08 PSTN Trunk Port, 30 Channel SIP PRI, 08 Digital Port, 15 IP User License, 5 IP Softphone/mobile user license, 08 VoIP Channel License along with 8 port Voice Mail expandable upto minimum 224 TDM ports and minimum 500 SIP/IP users without any add-on CPU or chassis/hardware platform.
SITC of Type-I IP Phone with 128 x 64 or better –pixel Graphical LCD , Extended SIP Protocol, LED for Call and message wait Indication, 3 Feature Keys:Headset, Mute, Hands-free speaker phone, 4 Context Sensitive Keys, 2 Line keys with Function such as navigation, Call Appearance , feature status, Volume Control Keys, 2 X RJ45 10/100/1000 Mbps Ethernet Ports, Power Over Ethernet (IEEE 802.3af), minimum one RJ9 Handset port, one RJ9 Headset port & Power Supply - 5VDC 0.6A, Power consumption - 1Watt, 0°C to 45°C or better, Certifications: TEC, CE, FCC, RoHS.
SITC of Pure IP-PBX which is IP at its core with IP switching technology and is having pure IP Architecture with embedded hardware platform, configured for 180 IP Extension, 04 PSTN Trunk Port, 30 Channel SIP PRI, 5 IP Softphone/mobile user license, 64 VoIP Channel License along with 4 port Voice Mail expandable upto 2000 IP Extensions without any add-on CPU/hardware platform. System should have provision to connect any TDM trunk and FXS extensions i.e. CO, PRI, GSM, Radio with external VoIP Gateway from same OEM. The system should support at least 21 concurrent Call Tapping and Conversation Recording, 64 Participants Audio Conference, 21 Three-party Conference Provision. The system should be IPV4 & IPV6 ready, should have VoIP and Voice mail at its core,The system should support SIP/IP extensions and SIP Trunks with the single VoIP module over SIP Protocol. The system architecture should be non-stackable eliminating individual power supply for each chassis. The system should have inbuilt Auto-attendant facility with multi lingual IVR, Corporate Directory Integration, Unified messaging, Returned Call to Original Caller (RCOC), CLI based DISA System, minimum 2 Gigabit Ethernet ports for LAN and WAN to separate out local and VoIP traffic on the external network. The system should have adapter based power supply with output of 24V DC, 2.5A. It should have dual power supply port for Hot redundancy. Certification: TEC, CE, FCC, ROHS.
SITC of IP user license for 10 User with required VOIP Channels. compatible to the IP PBX being used.
SITC of Daughter-board Module for VoIP Channels and IP user license. compatible to the existing IP PBX being used.
SITC of VoIP-FXS-FXO Gateway configured for required FXS(Analog) / FXO(CO) ports, VoIP Channels with SIP Accounts, minimum 1 Ethernet Port for network connectivity. It shall employ IP/PCM/TDM, 100% non-blocking, Digital-IP switching technology. It should have Password Protected Web based UI, TR069 for Mass Management, SNMP for Mass Monitoring, PCAP Trade. The Gateway device should have Peer-to-peer dialing facility with table entries. The Gateway device must have interoperability with different service providers. The Gateway should be available with Power supply/Power Adaptor of 24VDC, 2.5 A with maximum 60W power Consumption. Certification: TEC, CE, FCC, RoHS.
32 FXS / Analog ports, 32 VoIP Channels with 32 SIP Accounts
Supply, Installation, Testing & Commissioning of Chairman Unit with fixed microphone and flexible stem prority button for chairman microphone ,optioal chime tone facility for proceeding chairman announcement with two headphone socket built in loudspeaker is automatcally muted when the microphone is on/off button chairman mike unit should have a frequency responce 400hz to10hz ,length of microphone from base to steam should not be less than 488 mm in size ;nominal acoustic input 85 db SPL,dimensions (without microphone) (HxWxD) 50x135x135 mm; weight of unit should not be less then 1.2 kg ;operating temperature -5°C to +45°C,two 3.5mm (0.14 in) stereo headphone sockets; including make connecion testing etc complete as required.
supply, Installation, Testing & Commissioning of Delegate mike Unit with fixed microphone and flexible stem prority button for Deligate mike microphone ,optioal chime tone facility for proceeding Delegate mike announcement with two headphone socket built in loudspeaker is automatcally muted when the microphone is on/off button Delegate mike unit should have a frequency responce 400hz to10hz ,length of microphone from base to steam should not be less than 488 mm in size ;nominal acoustic input 85 db SPL,dimensions (without microphone) (HxWxD) 50x135x135 mm; weight of unit should not be less then 1.2 kg ;operating temperature -5°C to +45°C,two 3.5mm (0.14 in) stereo headphone sockets; including make connecion testing etc complete as required.
Supply, Installation, Testing & Commissioning of Control Unit for giving power to chairman unit asd delegate unit with inbulit 3 band equlilzer unit comprrising of knobs at 250hz, 2khz and 8khz volume control for 1 mic input 8 pin din connector for loop through should also consists microphone input with xlr connector with rated output impedance of 1000ohm and systems should have capability to control up 50 dicussion unit,unit dimensions should not be less then (85mm x 360mm x 250 mm) in size; including make connection testing etc complete as required.
SITC of 30 Watt speaker with taping facility having frequency range of 65Hz-20KHz@(-10db) with power handing of 200Watt continuous and more than 350 Watt @peak etc complete as required.
SITC of following capacity BIS certified 1Phase Input, 1Phase Output advance DSP controlled IGBT based rectifier Online UPS with Inbuilt Isolation Transformer having 0.99 Input power factor & 0.8 Output factor, Input voltage & frequency range of 180-300V on full load/ 110-300V on 50% load & 50 Hz +/- 5% and output voltage & frequency of 230V+/-1% & 50 +/- 0.1 Hz. Overall efficiency of upto 92% (without Transformer Loss), Overloading of 105 - 110% 30 mins, 111 - 130% 5 mins,131 - 150% 10 sec, THDv of < 3% for Linear & < 5% for Non linear load.UPS should have LED Panel with LCD display showing load level, Battery Voltage Level, Input & Output Voltage, Input & Output Frequency. UPS should have protection from Input High / Low;Over Load;Short Circuit; Over Temperature and give audible alarms on Battery Mode;Low Battery;Fault;Over Load & Bypass Mode. SMF Batteries of 12V VRLA for 30 mins with MS Rack and necessary cable for UPS to Batteries Installation. UPS should have valid Certification like Type III environmental declarations from third party renowned agency complying to ISO 14025, CE, ROHS,BIS,EN 62040-1, EN 62040-2, IEC 62040-3 Etc. as required.
5KVA UPS with 4992 VAH Battery
Supplying and drawing Fire Resistant flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables.
2 x 1.5 Sq.mm Unarmoured With Outer Sheath in Red Color
SITC of EN 54 / VDS certified Analog addressable Multi criteria photo thermal detector with mounting base & LED etc. as required.
SITC of EN 54 / VDS certified photoelectric Analog addressable Smoke detector with mounting base & LED etc. as required.
SITC of EN 54 / VDS certified Addessable Manual Call point (MCP) with LED / FIRE Indication Etc. as required.
SITC of EN 54 / VDS certified Addressable sounder with strobe light, Loop powered from FACP with sound level 90 dB and programmable from the panel etc. as required.
SITC of EN54 / VDS certified Microprocessor based intelligent, Analogue addressable,modular, Fire Alarm Control Panel with each loop capacity of 198 detectors/devices with minimum Loop length up to 1.2 KM and 500 mA loop power as per NFPA 72 approval. The Panel shall be able to give pin point location of addressable units via the address code for each unit. The Panel shall also be able to automatically switch off all control switches when-ever any Alarm is triggered. . The panel shall have 230 + 5 % volts power supply, Automatic battery charger, 24 AH 2 x 12V, SMF Lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condtion. Loop interface cards, communication module, Touch screen display unit to indicate Fire / Fault Signal of individual unit, inbuilt networking port( both RS485 & Ethernet), Serial port for printer, two supervisory inputs, two position key switch and USB port for programming.including the cost of all accessories Etc. as required.
2 - Loop Panel
SITC of Workstation latest Intel® i7 processor, Intel Chipset motherboard, 08 GB RAM, 1 TB SATA HDD at 7200 rpm, with 2 x 4GB GPU type higher end Graphic card for H.265 compression technique with dual display ports/DVI/ HDMI port, Giga LAN Card, wireless Keyboard, wireless optical Mouse.
SITC of EN 54 / VDS certified Active Repeater Panel for Fire Alarm System with inbuilt networking port ( both RS485 & Ethernet ), Serial port for printer, two supervisory inputs, two position key switch and USB port for programming. The Repeater Panel shall have touch screen display unit to acknowledge, reset, silence, program, view hisory events.etc (All functions similar to main panel) The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search. including the cost of all accessories Etc. as required.
SITC of Voice Alarm controller with built-in USB, MP3, AM/FM player, Bluetooth v5, SD Card with PTT Mic & required zone Paging system with prerecorded messages for voice evacuation·Provides required broadcast zone output function, the peak power of each zone 1000W, 1 line input , 1 microphone input, provides mix and emergency paging output mode as required of following zone.
SITC of 6W Ceiling Speaker with max SPL1M/1W 95dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W
Supply and laying speaker cable of ollowing size 2 core twin twisted multi stranded electrolytic grade copper conductor, overall PVC insulated and armoured cable (Blue colour) on surface/ above false ceiling including cost of GI spacers, saddles etc. as required.
GST @18 Percent
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.32 MB
EligibilitycriteriaofBiddersforqualifyinginTechnicalBid.pdf
Tender Documents • 0.59 MB
Engineering_Cost.pdf
Tender Documents • 0.48 MB
gentcalongwithdlptc.pdf
Tender Documents • 0.41 MB
PdBankAccountNumberDetails.pdf
Tender Documents • 0.30 MB
various_Circulars_orders.pdf
Tender Documents • 1.42 MB
agrement.pdf
Tender Documents • 0.45 MB
AnnexureABCD_RTPPAct2012_AnnexureC.pdf
Tender Documents • 0.10 MB
BOQ_955249.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid