Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-Finance H NO 2 ADARSH NAGAR ARJUN NAGAR NEAR MITTAL NURSING HOME AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-Finance Being lowest | |
| 2 | L2₹17.3 L+₹1,001 (0.06%)Rejected-Finance 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹17.9 L+₹58,806 (3.40%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹18.4 L+₹1.1 L (6.59%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹19.3 L+₹2.0 L (11.7%)Rejected-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
10 Jan 2020, 6:00 pmClosed
GE WEST AGRA
62 Station Road Agra Cantt
REPAIR AND MAINTENANCE OF SPLIT/WINDOW AC WATER COOLER FREEZE DEEP FREEZER ETC WITH MISC EM WORKS UNDER AGE EM (W) OF GE (W) AGRA
2019_MES_306936_1
8012/707/E8
Open Tender
Civil Works
Item Rate
270 days
GE WEST AGRA
For enlisted firm scanned copy of application on letter pad scanned copy of tender fee scanned copy of enlistment letter scanned copy of EPF allot letter Scanned copy GST registration number for unenlisted firm as per NIT
9 documents required · 9 mandatory
₹500
GE WEST AGRA
₹50,000
Yes
30 Mar 2020
16 Dec 2019
17 Jan 2020
16 Dec 2019
10 Jan 2020
30 Dec 2019
Amount
Labour only Servicing /repairing/maintenance of window type AC of 1.5/2.0 TR capacity AOR of AGE E/M (W) Agra and other area including repair/replacement of unserviceable/ burnt/ worn out spare parts (Shall be measured & paid separately under respective items as supply only here in after) and making appliance serviceable and testing on full load after repair/ replacement work of cooling appliances as per standard engineering practice and keeping proper records of maintenance activities (to be mentioned in maintenance record register supplied by the contractor) by skilled mechanic alongwith proper tools, safety measures etc complete all as specified and directed by Eng-in-Charge. Notes:- (i) Material required for repair/ replacement of defective parts shall be measured and paid separately under respective items here in after. (ii) Cost of minor items such as nuts, bolts, washers, screws, clips, saddles oil, grease etc as required at site to be included in unit quoted rates of items/jobs, & mechanic should be in position of all type of equipments. (iii) Location and place of complaints shall be as per requirement of maintenance work as per requirement under GE (W) Agra as directed by Engineer in charge/ JE concerned. (iv) Contractor shall be responsible to provide conveyance and required T&P for attend the complaints.
All as per item No. 1 here in before but for split AC of capacity 1.5/2.0 TR capacity.
All as per item No. 1 here in before but for refrigerator of any capacity.
All as per item No. 1 here in before but for deep freezer/ water cooler / water dispenser of any capacity.
Supply and fixing & testing of hermetically sealed unit compressor for 40/80 ltr capacity water cooler with compressor oil including gas charging and testing complete all as specified and directed. Make: KIRLOSKAR / TECUMESH/LG
Supply and fixing & testing of hermetically sealed unit compressor for 60/120 ltr capacity water cooler with compressor oil including gas charging and testing complete for water cooler all as specified and directed. Make: KIRLOSKAR / TECUMESH / LG
Supply and fixing & testing of hermetically sealed unit compressor for 150 ltr capacity water cooler with compressor oil including gas charging and testing complete for water cooler all as specified and directed. Make: KIRLOSKAR / TECUMESH / LG
Supply and fixing & testing of hermetically sealed unit compressor for 280/310 ltr capacity Deep Freezer with compressor oil including gas charging and testing complete for Deep Freezer all as specified and directed. Make: KIRLOSKAR / TECUMESH /LG Note for item No. 5 to 8: (i) Refrigerant gas shall be measured and paid separately under respective item here in after as supply only. (ii) Compressor shall be accompanied by Purchase voucher from authorized dealer of manufacturer and manufacturer's test certificate.
Supply only starting capacitor of 40-60 MFD capacity for water cooler any capacity complete all as specified and directed. Make: Epcos/TipconTesla
Supply only running capacitor of 10 MFD capacity for water cooler 40/80 ltr capacity complete all as specified and directed. Make: Epcos/TipconTesla
Supply only running capacitor of 15 MFD capacity for water cooler 60/120 ltr capacity complete all as specified and directed. Make: Epcos/TipconTesla
Supply only running capacitor of 25 MFD capacity for water cooler 150 ltr capacity complete all as specified and directed. Make: Epcos/TipconTesla
Dismantling burnt electric blower motor of AC of size 1/10 HP and fixing the same in its existing position after rewinding with super enameled copper winding wire of existing gauge and turn with and including top quality insulation materials such as varnish, cotton tape and sleeve etc and replacement of worn out/ unserviceable gun metal bushes complete all as specified and directed.
Dismantling of burnt electric blower of AC of size 1/8 HP and fixing the same in its existing position after rewinding with super enameled copper winding wire of existing gauge and turn with and including top quality insulation materials such as varnish, cotton tape and sleeve etc and replacement of worn out/ unserviceable gun metal bushes complete all as specified and directed.
Supply only flexible copper conductor cable PVC insulated & PVC sheathed of size 40/0.0076, 1100 Volt grade 3 core complete all as specified and directed. Make: Havells/Polycab/ Plaza/ Finolex
Supply only perforated condenser unit with copper tube and aluminium joints suitable for any type water cooler complete all as specified and directed.
Supply only over load/starting relay kit suitable for 165/280 ltrs capacity refrigerator of approved make and testing complete all as specified and directed.
Supply only thermostat switch suitable for 165 to 310 Ltr capacity refrigerator of approved make complete all as specified and directed. Make : INDFOSS / RENUTROL.
Supply and fixing & testing of company repaired hermetically sealed unit compressor for Refrigerator of 280 / 310 ltrs capacity with compressor oil including gas charging and testing complete all as specified and directed. Make : KIRLOSKAR/TECUMESH/GODREJ
Supply and fixing & testing of company repaired hermetically sealed unit compressor for Refrigerator of 165 ltrs capacity with compressor oil including gas charging and testing complete all as specified and directed Make : KIRLOSKAR/TECUMESH/GODREJ Note for item No 19&20 : (i) Refrigerant gas shall be measured and paid separately under respective item here in after as supply only. (ii) Compressor shall be accompanied by Purchase voucher from authorised dealer of manufacturer's and manufacturer's test certificate.
Supply only timer for frost free refrigerator (Self defrosting type) of capacity 280 to 310 ltrs capacity, suitable for LG / Samsung make refrigerators all as directed.
Supply only sensor switch for frost free refrigerator (Self defrosting type) of capacity 280 to 310 ltrs capacity, suitable for LG / Samsung make refrigerators all as directed.
M & L for repairing the refrigerator or water cooler body by cutting the worn out/ rusted/damaged portion of body with the help of gas welding and jointing the pieces of 18 gauge MS sheet with gas welding as required and making the surface smooth to match the existing surface by grinding and then applying two coats of DUCCO paint with spray machine over one coat of red oxide primer complete all as specified and directed
Supply only door gasket suitable for 165 to 310 Ltrs capacity of approve quality/ make of refrigerator complete all as specified and directed
Supply only vegitable tray made out of high quality PVC / plastic, clear transparent type suitable for 165 to 310 Ltrs capacity refrigerator of of approved quality/ make complete all as specified and directed
Supply only thermostat switch adjustable type suitable for window type AC of 1.5 TR / 2 TR Capacity complete all as specified and directed. Make : RENUTROL / INDFOSS
Supply only starting relay suitable for any type AC of 1.5 TR/2 TR capacity complete all as specified and directed. Make : Anpurnaa / Microtech/RENUTROL
Supply and fixing & testing of company repaired hermetically/rotary sealed compressor unit with compressor oil suitable for 1.5 TR capacity window type AC including gas charging complete all as specified and directed. Make : KIRLOSKER / TECUMESH.
Supply and fixing & testing of company repaired hermetically/rotary sealed compressor unit with compressor oil suitable for 2 TR capacity window type AC including gas charging complete all as specified and directed. Make : KIRLOSKER / TECUMESH.
Supply and fixing & testing of company repaired hermetically/rotary sealed compressor unit with compressor oil suitable for 1.5 TR capacity Split AC including gas charging complete all as specified and directed. Make : KIRLOSKER / TECUMESH.
Supply and fixing & testing of company repaired hermetically/rotary sealed compressor unit with compressor oil suitable for 2 TR capacity Split AC including gas charging complete all as specified and directed. Make-KIRLOSKER/ TECUMESH. Note for Item No 28 to 31 (i) Refrigerant gas will be measured and paid separately under respective item here in after. (ii) Compressor should be accompanied by Purchase voucher from authorised dealer of manufacturer and manufacturer's test certificate.
Supply only starting capacitor of 100-120 MFD capacity for air conditioner 1.5 TR complete all as specified and directed. Make : EPCOS/TIPCON/TESLA
Supply only starting capacitor of 120-150 MFD capacity for air conditioner 2.0 TR complete all as specified and directed. Make : EPCOS/TIPCON/TESLA
Supply only running capacitor of 36 MFD capacity for air conditioner 1.5 TR complete all as specified and directed. Make : EPCOS/TIPCON/TESLA
Supply only running capacitor of 40/ 45 MFD capacity for air conditioner 2.0 TR complete all as specified and directed. Make : EPCOS/TIPCON/TESLA
Dismantling of burnt blower motor 1/6 HP capacity of split type AC and rewinding the same with super enameled copper winding wire of same gauge and turn with and including top quality insulation material such as varnish, cotton tape & sleeves etc and replacement of gun metal bush / bearing and re-fixing back in its original position complete after testing all as directed.
Supply only aluminium / hard PVC fan blade of blower motor suitable for window type AC of 1.5 TR / 2 TR capacity complete all as specified and directed.
S & F in repairs PCB suitable for 1.5/2.0 TR capacity split type AC complete all as specified and directed.
S & F in repairs PCB suitable for 4.0/5.0 KVA capacity voltage stablizer complete all as specified and directed .
S & F in repairs PCB suitable for 0.50/1.0 KVA capacity voltage stablizer complete all as specified and directed .
Taking out burnt components of auxiliary PCB of voltage stabilizer of 4.0/5.0 KVA capacity and re-fixing back in original position after making it serviceable/repair complete all as specified and directed.
Taking out burnt components of auxiliary PCB of voltage stabilizer of 0.50/1.0 KVA capacity and re-fixing back in original position after making it serviceable/repair complete all as specified and directed.
S & F in repairs auxiliary transformer of voltage stabilizer of 4.0/5.0 KVA capacity complete all as specified and directed.
S & F in repairs auxiliary transformer of voltage stabilizer of 0.51/1.0 KVA capacity complete all as specified and directed.
S & F in repair main transformer of voltage stabilizer 5.0 KVA capacity complete complete all as specified and directed.
S & F in repair main transformer of voltage stabilizer 4.0 KVA capacity complete complete all as specified and directed.
S & F in repair main transformer of voltage stabilizer 1.0 KVA capacity complete complete all as specified and directed.
S & F in repair main transformer of voltage stabilizer 0.50 KVA capacity complete complete all as specified and directed.
S & F in repairs auto cut off relay / time delay relay complete suitable for the 4.0/5.0 KVA capacity voltage stabilizer complete complete all as specified and directed.
S & F in repairs MCB, SP, 25 Amp, 'C' series complete all as specified and directed.
Supply only plazma filters of window type AC/Split AC of capacity 1.5 TR/ 2 TR of any make, dismantling and cleaning the unit with air blower including replacement of air filter complete all as specified and directed.
M&L for cutting and removing the rusted/ worn out portions of the water cooler bottom / base of any make/ size and making new base with MS sheet and angle iron of the existing gauge and size, including provision of standing legs made either with sheets or angle iron and also carried out two coats of black synthetic enameled paint over a coat of red oxide all as specified and directed
M&L for taking down carefully window type ACs of any capacity, any make and refixing the same in other location in the same complex including making all necessary electric connections and making functional the same at new location all as directed.
M&L for taking down carefully the indoor and outdoor unit of split Air conditioner of any capacity from existing location and fixing the complete unit in new location of same complex including making all electric and copper tubing connections and necessary wall brackets provided for the outdoor unit all as specified and directed.
Supply only copper tubes of 5/8’’ dia of 2.0 TR capacity Split Air conditioner including flare nuts as required at sit complete all as specified and as directed.
Supply only copper tubes of 3/8’’ dia of 1.5 TR capacity Split Air conditioner including flare nuts as required at sit complete all as specified and as directed.
Supply only copper tubes of 1/2’’ dia of any type Split Air conditioner including flare nuts as required at sit complete all as specified and as directed.
Supply only flexible PUF type foam type insulation suitable for insulating the suction and discharge line of split Air conditioner complete all as specified and as directed.
M&L for repair to remote control of any type of ACs (Split/ Window) including replacement of worn out parts all as directed.
Supply only swing motor for any type AC complete all as specified and directed
Supply & fix in repairs solonoied reverse switch for any type of split AC complete all as specified and directed
M & L for detection of leakage of deep freezer inside the cabinet/puf/insulated body including changing new condenser/Puf of complete deep freezer of capacity 300 ltrs and make it functional complete all as specified and as directed.
Supply only outdoor split AC 2.0 TR capacity condenser unit with copper tube as per existing make complete all as specified and directed.
Supply only outdoor split AC 1.5 TR capacity condenser unit with copper tube as per existing make complete all as specified and directed.
Supply only refrigerant gas M-22 in cylinders of required capacity including transportation, loading and unloading charges for collection of empty cylinders from MES store yard of AGE E/M, returning the same cylinder or other cylinder after refilling and testing of cylinders including test certificate by authorised agencies complete all as specified and directed.
Supply only refrigerant gas M-134 (a) in cylinders of required capacity including transportation, loading and unloading charges for collection of empty cylinders from MES store yard of AGE E/M, returning the same cylinder or other cylinder after refilling and testing of cylinders including test certificate by authorised agencies complete all as specified and directed.
Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbedsurfaces of wall/ floor complete all as specified and directed.
M&L for concealed sub-main single phase two wire with PVC insulated and unsheathed FRLS, multistranded copper conductor cable of size 4.0 sqmm drawn through & including PVC rigid conduit medium quality 20mm bore from main board to sub main board including 2.50 Sqmm PVC insulated unsheathed FRLS stranded copper conductor cable as earth wire including cutting chases to brick wall for inserting conduit and making good in CM 1:4 and finishing the surface to match with the existing specifications complete all as specified and directed. (Note: (i) Measuring unit comprises two sub main wire, one earth wire, conduit and cutting chases all as described above. (ii) Proper colour code for different wires phase, neutral & earth shall be used. (iii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Supply only indoor unit with copper tubing of split type suitable for 1.5 TR capacity all as per existing model remote control type including remote control and testing complete all as directed. MAKE : HITACHI/VOLTAS/BLUE STAR/TOTAL LINE.
Supply only indoor unit with copper tubing of split type suitable for 2.0 TR capacity all as per existing model remote control type including remote control and testing complete all as directed. MAKE : HITACHI/VOLTAS/BLUE STAR/TOTAL LINE.
Supply and fixing in repair sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin and earth plug and socket with one No.MCB, SP, 230 volts, 20 Amps complete all as specified and directed. Make : Legrand cat part No-4024-32 to 37 or eqivalant model of Havells/HPL
PD GUPTA AND COMPANY
M/S RAJENDRA KUMAR AGARWAL
M/S J J ENTERPRISES
Shiva Enterprises
Gupta Automobiles
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .