Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹5.4 LQualified Make: Base Light
Model: Base Light 420X 6052 1 SECTOR D VASANT KUNJ NEW DELHI DELHI 110070 | NEW DELHI | DELHI | 110070 | Make: Base Light
Model: Base Light 420X | L1 | Qualified | |
| 2 | L2₹5.4 L+₹100 (0.02%)Qualified Make: Base Light
Model: Base Light 420X 27 BANK ENCLAVE LAXMI NAGAR DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: Base Light
Model: Base Light 420X | L2 | Qualified | |
| 3 | Qualified Make: Base Light
Model: Base Light 420X 91 23 JOGI VALI GLI DEVI PURA II KRISHNA NAGAR KRISHNA NAGAR DEVI PURA II BULANDSHAHR UTTAR PRADESH 203001 | BULANDSHAHR | UTTAR PRADESH | 203001 | Make: Base Light
Model: Base Light 420X | - | Qualified | |
| 4 | L3₹5.4 L+₹150 (0.03%)Disqualified Make: SECUTEC
Model: SECUTEC- S2000 10 239 KHICHRIPUR EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | Make: SECUTEC
Model: SECUTEC- S2000 | L3 | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
23 Jul 2018, 5:00 pmClosed
Emergency lighting and accessories (PORTABLE EMERGENCY LIGHTING SYSTEM Tower type With AC Genset) Emergency Lighting And Accessories (PORTABLE EMERGENCY LIGHTING SYSTEM Tower Type With AC Genset) ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Portable emergency lighting system consisting one Gen set
Tower/Telescopic collapsible mast/Vertical mast
LED Luminaire
Supporting kits
Tool Kits
Storage box for tool kit (Tool kit list to be furnihed by seller at the time of supply) Yes - Rating of Generator set (in KVA) (Minimum) 0.5 KVA 0.5 KVA
1.0 KVA
2.0 KVA
3.0 KVA
5.0 KVA
6.0 KVA
8.0 KVA Number of cylinder in the Engine 2 Cylinder 2 Cylinder
3 Cylinder Minimum continuous working hours 8 hours 2 hours
4 hours
8 hours
10 hours
12 hours
30 hours
60 hours
90 hours
100 hours Gen set fuel tank capacity (Minimum) - 3 litres 3 litres
5 litres
7 litres
10 litres
20 1/6 in litres litres
40 litres
80 litres
100 litre
120 litres Type of fuel Petrol - Minimum System Lumens 50000 As per GeM Catalogue. IP rating of LED Luminaire IP67 - Ruggedised Storage Box for main equipment Yes - TOWER CONSTRUCTION Maximum of height of Tower/lelescopic collapsible mast/Vertical Mast with light source (in meters from base ground level) Yes - Material of Tower/Telescopic collapsible mast Vertical Mast Mild steel Aluminium
Mild steel
Galvanised Iron
Fiber Minimum thickness of Tower/Telescopic collapsible mast/Vertical Mast material (+/-5%) 3 mm - Method of step up and step down of Tower Telescopic collapsible mast/Vertical Mast Manual - Step up and step down time of Tower Telescopic collapsible mast/Vertical Mast </=2 Minutes - The strength of the Tower/Telescopic collapsible mast/Vertical Mast tower is to provide support for it to remain erect at wind speed of 40 km/hr - GENERATOR SET CONSTRUCTION Generator Set: Recoil start portable AC Generating set comprising AC Generator with declared rating 230 V Single Phase of unit power factor conforming to IS:13364 (Part 1/92) and petrol Yes - 2/6 run air cooled four stroke single cylinder engine with resettable circuit breaker in the AC output Type of mounting With out trolley With out trolley
With trolley Engines shall conforming to IS:7347/1974 (Reaffirmed in 2006) latest Yes - Alternator shall conforming to IS: 13364 (Part 1)/1992 (Reaffirmed 2003) latest Yes - System should work on 220/230V
50 Hz AC supply and for connecting to the mains shall have provision for 15 Amps 3 Pin/2 pin Socket and a suitable lead wire with plugs at both ends Yes - LED LUMINAIRE CONSTRUCTION LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes - Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes - LED Modules as per the IS: 16103(Part-2)/2012 Yes - Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt - LED chip Efficacy ≥130 Lm/Watt - Colour temperature (+/-500K) 6000K - Working life for LED (Minimum 50
000 burning hours as per LM-80 report) >/= 50
000 burning hours - Colour Rendering Index(CRI) ≥70 - Optic lense materal (UV Poly carbonate lense - 3/6 stabilised) The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes - The luminaire body must be corrosion resistant powder coated Yes - All fastners must be of stainless steel Yes - Extruded silicon loop gasket shall be provided to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust
water
insects etc.
Yes - Luminaries light transparency should be of Toughened glass Yes - Toughned transparent glass cover thickness >/=4 mm - Toughned Glass shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes - Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes - Operating temperature range -20 deg. C to +50 deg. C - "Manufactures Name and and brand on the aluminium die cast body " Engraved/Embossed - Date of manufacture (month-year)
and lot number as identification mark inside of each unit Yes - REPORTS AND Availability of type test Yes - 4/6 CERTIFICATIONS reports from Central Government Laboratory/NABL Accrediated/ILAC Laboratory for complete Portable emergency lighting system including for Engine
Alternator and Luminaires as per relevant IS specifications as applicable Luminaire System must have EMI/EMC compliance as applicable (Test reports shall be furnish on demand by buyer/consignee) Yes - Availability for LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government NABL/ILAC accrediated lab. (Reports shall be furnish on demany by buyer/Consignee) Yes - Availability of LM 80 & TM 21 (Ref. IS:16105:2012) Report and Photo biological report for LED report from Central Government NABL/ILAC accrediated lab. (LM-80 report shall have the Pohoto Biological report of the LED Chip being used in the luminaire) (Reports shall be furnish on demany by buyer Consignee) Yes - LED Luminaire shall have Complusory Registration(CRS) of BIS for safety as per IS 10322 (Part 5/Section 5): 2012 or as applicable for portable emergency lighting system as applicable as on date Yes - 5/6 Total Weight of complete system (Must declare) in Kg </=100 Kg - Warranty for complete system 2 Years - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Narender Singh 134116
50TH BN ITB POLICE SEC-26 PANCHKULA HARYANA 1 15
337348
GEM/2018/B/47814
Emergency lighting and accessories (PORTABLE EMERGENCY LIGHTING SYSTEM Tower type With AC Genset)
15 days
Haryana; Panchkula
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Emergency lighting and accessories (PORTABLE EMERGENCY LIGHTING SYSTEM Tower type With AC Genset) Emergency Lighting And Accessories (PORTABLE EMERGENCY LIGHTING SYSTEM Tower Type With AC Genset) ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Portable emergency lighting system consisting one Gen set | - | - | - |
| Tower/Telescopic collapsible mast/Vertical mast | - | - | - |
| LED Luminaire | - | - | - |
| Supporting kits | - | - | - |
| Tool Kits | - | - | - |
| Storage box for tool kit (Tool kit list to be furnihed by seller at the time of supply) Yes - Rating of Generator set (in KVA) (Minimum) 0.5 KVA 0.5 KVA | - | - | - |
| 1.0 KVA | - | - | - |
| 2.0 KVA | - | - | - |
| 3.0 KVA | - | - | - |
| 5.0 KVA | - | - | - |
| 6.0 KVA | - | - | - |
| 8.0 KVA Number of cylinder in the Engine 2 Cylinder 2 Cylinder | - | - | - |
| 3 Cylinder Minimum continuous working hours 8 hours 2 hours | - | - | - |
| 4 hours | - | - | - |
| 8 hours | - | - | - |
| 10 hours | - | - | - |
| 12 hours | - | - | - |
| 30 hours | - | - | - |
| 60 hours | - | - | - |
| 90 hours | - | - | - |
| 100 hours Gen set fuel tank capacity (Minimum) - 3 litres 3 litres | - | - | - |
| 5 litres | - | - | - |
| 7 litres | - | - | - |
| 10 litres | - | - | - |
| 20 1/6 in litres litres | - | - | - |
| 40 litres | - | - | - |
| 80 litres | - | - | - |
| 100 litre | - | - | - |
| 120 litres Type of fuel Petrol - Minimum System Lumens 50000 As per GeM Catalogue. IP rating of LED Luminaire IP67 - Ruggedised Storage Box for main equipment Yes - TOWER CONSTRUCTION Maximum of height of Tower/lelescopic collapsible mast/Vertical Mast with light source (in meters from base ground level) Yes - Material of Tower/Telescopic collapsible mast Vertical Mast Mild steel Aluminium | - | - | - |
| Mild steel | - | - | - |
| Galvanised Iron | - | - | - |
| Fiber Minimum thickness of Tower/Telescopic collapsible mast/Vertical Mast material (+/-5%) 3 mm - Method of step up and step down of Tower Telescopic collapsible mast/Vertical Mast Manual - Step up and step down time of Tower Telescopic collapsible mast/Vertical Mast </=2 Minutes - The strength of the Tower/Telescopic collapsible mast/Vertical Mast tower is to provide support for it to remain erect at wind speed of 40 km/hr - GENERATOR SET CONSTRUCTION Generator Set: Recoil start portable AC Generating set comprising AC Generator with declared rating 230 V Single Phase of unit power factor conforming to IS:13364 (Part 1/92) and petrol Yes - 2/6 run air cooled four stroke single cylinder engine with resettable circuit breaker in the AC output Type of mounting With out trolley With out trolley | - | - | - |
| With trolley Engines shall conforming to IS:7347/1974 (Reaffirmed in 2006) latest Yes - Alternator shall conforming to IS: 13364 (Part 1)/1992 (Reaffirmed 2003) latest Yes - System should work on 220/230V | - | - | - |
| 50 Hz AC supply and for connecting to the mains shall have provision for 15 Amps 3 Pin/2 pin Socket and a suitable lead wire with plugs at both ends Yes - LED LUMINAIRE CONSTRUCTION LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes - Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes - LED Modules as per the IS: 16103(Part-2)/2012 Yes - Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt - LED chip Efficacy ≥130 Lm/Watt - Colour temperature (+/-500K) 6000K - Working life for LED (Minimum 50 | - | - | - |
| 000 burning hours as per LM-80 report) >/= 50 | - | - | - |
| 000 burning hours - Colour Rendering Index(CRI) ≥70 - Optic lense materal (UV Poly carbonate lense - 3/6 stabilised) The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes - The luminaire body must be corrosion resistant powder coated Yes - All fastners must be of stainless steel Yes - Extruded silicon loop gasket shall be provided to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust | - | - | - |
| water | - | - | - |
| insects etc. | - | - | - |
| Yes - Luminaries light transparency should be of Toughened glass Yes - Toughned transparent glass cover thickness >/=4 mm - Toughned Glass shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes - Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes - Operating temperature range -20 deg. C to +50 deg. C - "Manufactures Name and and brand on the aluminium die cast body " Engraved/Embossed - Date of manufacture (month-year) | - | - | - |
| and lot number as identification mark inside of each unit Yes - REPORTS AND Availability of type test Yes - 4/6 CERTIFICATIONS reports from Central Government Laboratory/NABL Accrediated/ILAC Laboratory for complete Portable emergency lighting system including for Engine | - | - | - |
| Alternator and Luminaires as per relevant IS specifications as applicable Luminaire System must have EMI/EMC compliance as applicable (Test reports shall be furnish on demand by buyer/consignee) Yes - Availability for LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government NABL/ILAC accrediated lab. (Reports shall be furnish on demany by buyer/Consignee) Yes - Availability of LM 80 & TM 21 (Ref. IS:16105:2012) Report and Photo biological report for LED report from Central Government NABL/ILAC accrediated lab. (LM-80 report shall have the Pohoto Biological report of the LED Chip being used in the luminaire) (Reports shall be furnish on demany by buyer Consignee) Yes - LED Luminaire shall have Complusory Registration(CRS) of BIS for safety as per IS 10322 (Part 5/Section 5): 2012 or as applicable for portable emergency lighting system as applicable as on date Yes - 5/6 Total Weight of complete system (Must declare) in Kg </=100 Kg - Warranty for complete system 2 Years - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Narender Singh 134116 | - | - | - |
| 50TH BN ITB POLICE SEC-26 PANCHKULA HARYANA 1 15 | - | - | - |
Exempted
23 Jul 2018
16 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_337348.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .