Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAdmitted-Finance | ₹1.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.4 Cr+₹1.9 L (1.43%)Admitted-Finance 31 A SELVAVINAYAGAR KOIL STREET THIRUVALLUVAR NAGAR ITI BACKSIDE G N MILLS POST COIMBATORE DISTRICT PIN 641 029 | COIMBATORE | COIMBATORE | TAMIL NADU | 641029 | ₹1.4 Cr+₹1.9 L (1.43%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | CLASSIC ENGINEERING ENTERPRISES L2 | KSP and Co L1 |
|---|---|---|---|---|---|
| 1.00Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. | |||||
| 1.10 | 1200mm dia FULL BORE ELECTROMAGNETIC FLOW METER | 1 | Nos | 13,05,000 ₹13,05,000 | 13,01,200 ₹13,01,200 Lowest |
| 1.20Supply and Delivery of MS D/F Dismantlig Joint with IS-2026 Gr. E250, Studs & Nuts Stainess Steel AISI-304 Sealing Ring EPDM Rubber types to pressure rating of 2.0 PN to be used in Raw Water Pump houses Confirming to IS.2062 , IS1538 etc. Completed.Dismantling Joint | |||||
| 1.30 | 1200mm dia | 1 | Nos | 7,00,000 ₹7,00,000 | 6,89,500 ₹6,89,500 Lowest |
| 1.40Charges for Erection and Commissioning of 1200mm dia Electromagnetic Flow Meter and Dismandling Joint including removing the Existing Flow meter, Welding the Flange, with all other accessories, Including Material Handling Charges, Transporting and Labour Charges etc. | |||||
| 1.50 | 1200mm dia FULL BORE ELECTROMAGNETIC FLOW METER | 1 | Nos | 7,00,000 ₹7,00,000 | 6,79,900 ₹6,79,900 Lowest |
| 1.60Supply, Delivery, of 600mm Cast Steel Non-Rising Spindle Sluice valves (Manually Gear Operation) types to pressure rating of 2.0 PN to be used in Pump houses (Long body / Long face to Face) Confirming to IS.14846/2000(PD Type) | |||||
| 1.70 | 600mm dia | 5 | Nos | 8,00,000 ₹40,00,000 | 7,82,400 ₹39,12,000 Lowest |
| 1.80Manufacture, supply and delivery of DI D/F Slanted seat Tilting Disc Swing Check Valve in single piece body and closed eye disc construction. Hemisherical disc with 59 degree inclination for fast open and closing. Corrosion proof and wear resistent(triple offset) disc face & body seat face, both made of fusion bonded Nickel Chromium weld overlay and microfinished. Body and disc of ductile cast iron GGG-40, medium free(dry) shafts of stainless steel and bearings of Zincfree Bronze, Valve should have provision for internal damping unit for reducing the effects of water hammer/surge, if required at later stage. Electrostatic epoxy powder/liquid coating(EP-P) inside and outside color blue RAL 5005 with minimum coating thickness of 150 microns. The EPDM rubber & Epoxy Powder should be approved by W 270.(EP-P it isa resi-coat powder approved for drinking water application, applied through fusion bonding technology process by dipping the shot-blasted casted components heated upto 200deg C). Face to face dimensions as per EN 558-1 series 14 and flange connections as per EN 1092-2/IS | |||||
| 1.90 | 600mm dia | 5 | Nos | 7,65,000 ₹38,25,000 | 7,59,500 ₹37,97,500 Lowest |
Tender Value
₹1.6 Cr
EMD Value
₹1.6 L
Closing Date
20 Mar 2025, 3:00 pmClosed
THE COMMISSIONER, SALEM CITY MUNICIPAL CORPORATION
Salem City Municipal Corporation, Fort Main Road, Salem.
Revamping the existing Water Treatment Plant 155MLD in Thottilpatti relating to Salem Corporation Dedicated Water Supply Scheme.
2025_MAWS_532772_1
E2-EST NO-7716-2024-2
Open Tender
Civil Works
Lump-sum
180 days
SALEM CITY MUNICIPAL CORPORATION
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1.6 L
25 Mar 2025
15 Mar 2025
20 Mar 2025
15 Mar 2025
20 Mar 2025
15 Mar 2025
Amount
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished.
1200mm dia FULL BORE ELECTROMAGNETIC FLOW METER
Supply and Delivery of MS D/F Dismantlig Joint with IS-2026 Gr. E250, Studs & Nuts Stainess Steel AISI-304 Sealing Ring EPDM Rubber types to pressure rating of 2.0 PN to be used in Raw Water Pump houses Confirming to IS.2062 , IS1538 etc. Completed.Dismantling Joint
1200mm dia
Charges for Erection and Commissioning of 1200mm dia Electromagnetic Flow Meter and Dismandling Joint including removing the Existing Flow meter, Welding the Flange, with all other accessories, Including Material Handling Charges, Transporting and Labour Charges etc.
1200mm dia FULL BORE ELECTROMAGNETIC FLOW METER
Supply, Delivery, of 600mm Cast Steel Non-Rising Spindle Sluice valves (Manually Gear Operation) types to pressure rating of 2.0 PN to be used in Pump houses (Long body / Long face to Face) Confirming to IS.14846/2000(PD Type)
600mm dia
Manufacture, supply and delivery of DI D/F Slanted seat Tilting Disc Swing Check Valve in single piece body and closed eye disc construction. Hemisherical disc with 59 degree inclination for fast open and closing. Corrosion proof and wear resistent(triple offset) disc face & body seat face, both made of fusion bonded Nickel Chromium weld overlay and microfinished. Body and disc of ductile cast iron GGG-40, medium free(dry) shafts of stainless steel and bearings of Zincfree Bronze, Valve should have provision for internal damping unit for reducing the effects of water hammer/surge, if required at later stage. Electrostatic epoxy powder/liquid coating(EP-P) inside and outside color blue RAL 5005 with minimum coating thickness of 150 microns. The EPDM rubber & Epoxy Powder should be approved by W 270.(EP-P it isa resi-coat powder approved for drinking water application, applied through fusion bonding technology process by dipping the shot-blasted casted components heated upto 200deg C). Face to face dimensions as per EN 558-1 series 14 and flange connections as per EN 1092-2/IS
600mm dia
Supply, Delivery of MS D/F Dismantlig Joint with IS-2026 Gr. E250, Studs & Nuts Stainess Steel AISI-304 Sealing Ring EPDM Rubber types to pressure rating of 2.0 PN to be used in Raw Water Pump houses Confirming to IS.2062 , IS1538 etc. Completed.
600mm dia
Charges for Erection and Commissioning of 600mm dia Cast Steel Non-Rising Spindle Sluice valves, Tilting Disc Swing Check Valve and Dismandling Joint including removing the Existing Flow meter, Welding the Flange, with all other accessories, Including Material Handling Charges, Transporting and Labour Charges etc.
600mm dia
CLASSIC ENGINEERING ENTERPRISES (BID ID -1274543)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.03 MB
Tendernotice_2.pdf
PDF • 1.03 MB
BOQ_634200.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .