Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹22.8 L+₹3.1 L (15.5%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹24.9 L+₹5.1 L (25.9%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹25.0 L+₹5.2 L (26.5%)Rejected-Finance BHU | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹26.6 L+₹6.9 L (34.8%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
21 Sept 2023, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE(AF) Chakeri
REPAIR /MAINT OF LT OVER HEAD LINES, UG CABLE, CONTROL PANELS AND OTHER MISC E/M CONNECTED WORK IN DOMESTIC AREA AT 7 AFH KANPUR
2023_MES_615301_1
8647/E8
Open Tender
Civil Works
Item Rate
180 days
Area under GE(AF) EM Chakeri
As per tender documents
9 documents required · 9 mandatory
₹500
GE (AF) E/M CHAKERI
₹60,000
Yes
17 Nov 2023
23 Aug 2023
27 Sept 2023
24 Aug 2023
21 Sept 2023
8 Sept 2023
Amount
Excavation in trenches n.exc. 1.5 m wide and n.exc.1.5m in depth for laying of XLPE insulated Cable including getting out in soft/loose soil all as specified & directed by Engr-in-Charge
Returning filling in and including spreading leveling watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as directed by Engineer in Charge.
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc 1.5 m above starting point all as directed by Engineer in Charge.
M&L for spreading & leveling dry clean Ganga sand in trenches for cushioning UG cable (15 cm before laying of cable and 08 cm after laying of cable ) complete all as specified and directed. (Note: For payment purpose punned thickness of sand shall be measured)
M&L for sub class old size of Brick in trenches for cable protection of LT Cables with width equal to length of brick complete all as specified and directed.
S&F in replacement of 80 mm dia light grade galvanised steel tubing with all fittings and fixed to poles / walls with mild steel clamps, bolts, nuts and washers complete all as spefified and directed
S&F in replacement of 50 mm dia light grade galvanised steel tubing with all fittings and fixed to poles / walls with mild steel clamps, bolts, nuts and washers complete all as spefified and directed
M & L for boring through existing road with trench less method for passing of UG Cable all as directed by Engineer in Charge.
Supply and laying XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 400 sq mm 3.5 core ,laid in trenches /ducts /encased in GI pipe /fixed to pole including taking out of existing unserviceable cable / OH conductor all as specified and directed. Note:- Layout digram/Key plan of cable laid shall be recored in MB
All as per item no. 09 here in before but XLPE cable of size 240 Sqmm, 3.5 core
All as per item no. 09 here in before but XLPE cable of size 185 Sqmm, 3.5 core
All as per item no. 09 here in before but XLPE cable of size 150 Sqmm, 3.5 core
All as per item no. 09 here in before but XLPE cable of size 120 Sqmm, 3.5 core
All as per item no. 09 here in before but XLPE cable of size 95 Sqmm, 3.5 core
All as per item no. 09 here in before but XLPE cable of size 70 Sqmm, 3.5 core
All as per item no. 09 here in before but XLPE cable of size 50 Sqmm, 3.5 core
All as per item no. 09 here in before but XLPE cable of size 35 Sqmm, 3.5 core
All as per item no. 09 here in before but XLPE cable of size 25 Sqmm, 4.0 core
Taking out old defective UG cable of any size up to 300 Sqmm, 3/3.5 core all as directed by Engineer in Charge.
Re laying of serviceable Cable obtained of any size and discription in any position complete all as directed by Engineer in Charge. (i) Excavation, earth work, sand cushioning, protection cover/GI pipe shall be measured and paid separately under respective item of Schedule 'A'. (ii) Layout of cable rout shall be mentioned in MB for record purpose.
Supply Joining , commissioning and testing in replacement of Heat Shrinkable end termination joint Out door type and suitable for cable of size 120 to 185 sqmm 3 core complete with all fittings and jointing materials suitable for HT11 KV ( E ) XLPE cable all as specified and directed.
Supply Joining , commissioning and testing in replacement of Heat Shrinkable straight though joint suitable for cable of size 120 to 185 sqmm 3 core complete with all fittings and jointing materials suitable for HT11 KV ( E ) XLPE cable all as specified and directed.
Supply Joinging , commissioning and testing in replacement of Heat Shrinkable end termination joint Out door type and suitable for cable of size 240 to 300 sq mm 3 core complete with all fittings and jointing materials suitable for HT11 KV ( E ) XLPE cable all as specified and directed.
Supply Joinging , commissioning and testing in replacement of Heat Shrinkable straight through joint suitable for cable of size 240 to 300 sq mm 3 core complete with all fittings and jointing materials suitable for HT11 KV ( E ) XLPE cable all as specified and directed.
M&L for replacement heat shrinkable type straight through joint suitable for cable of size 25 to 50 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
M&L for replacement heat shrinkable type straight through joint suitable for cable of size 70 to 150 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
M&L for replacement heat shrinkable type straight through joint suitable for cable of size 185 to 400 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
M&L for replacement heat shrinkable type End joint suitable for cable of size 25 to 50 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
M&L for replacement heat shrinkable type End joint suitable for cable of size 70 to 150 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
M&L for replacement heat shrinkable type End joint suitable for cable of size 185 to 400 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
Supply, installation, commissioning and testing in replacement powder coated factory made panel board outdoor type CPRI approved confirming to IP 64 protaction, of suitable size made of Robust steel sheet construction made from min 2.10 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate. The panel will be prewired with suitable size PVC insulated copper conductor cable, multistranded housed with the following accessories:-
M&L for replacement of floor mounted LT panel board outdoor type factory made and tested (CPRI approved) 415 volts 3 phase 4 wire 50 HZ AC supply having busbar chamber 800 Amps Aluminium strip TPN, installed on porcelain insulators, and copper conductor wiring , the panel shall be dust and vermin proof and made up of 3.15 mm CRCA mild steel sheet and 40x40x6 mm thick angle iron frame work , powder coated finish over one coat of red oxide primer out side and in side, front and rear opening type, with aprons for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated solid copper conductor FRLS cables, IS -694 marked of adequate size but not less than 4 sq mm and suitable to accomodate and including the following acessories:-
M&L for earthing complete with galvanised or steel earth plate electrode of size 600x600x6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to strip 32x 6 mm size drwn throun 40mm GI light grade pipe with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 3 of SSR -2009 Part-I and connecting to earthing test point,main switch board and testing on completion including PCC chamber concrete (1:3:6) type C-2 and RCC cover 75mm thick reinforced with mild steel TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all as shown in electrical plate in No 3 of SSR(Pt-I)2009 and including providing earth identification plate (indicating earth test results, earthing number & date of earthing with black paint over white paint back ground) of 1.6mm thick welded with 25x25x5mm angle iron goruted in ground in PCC 1:3:6 type C2 complete all as specified and dirfected by Engineer-in-charge. Note:- up to 7.5mtr earth strip shall be deemed to be inclusive in quoted unit rate.
M&L for in replacement of danger notic plate of 1.6 mm thick mild steel sheet vitreous enameled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT system of size 25x20 mm all as directed by Engineer in Charge
Material and labour for replacement of old rubber insulating mat of size 2Mx1MX25 MM Thick for HT equiment ISI Marked all as specified and direceted.
S& F in replacement insulator pin type porcelain vitreous white brown or green including galvanized MS spindle two GI Washers and one GI Nut 150 mm height 150 mm dia for 11000 volts grade complete all as specified and directed .
S&F in replacement of disc type insulator porcelain vitreous white brown or green including 145mm high and 255 mm dia ball & socket type single disc assemblpy for 11000 volts grade complete all as specified & directed.
M & L for applying one coat of superior quality enameled aluminium paint on all exposed surface on steel tubular poles (HT Poles) cross arms including all associated fitting after necessary surface preparation of old painted surface complete including marking space for numbering by good quality black paint on steel surface of size 150x100 mm at 1.5 Mtr from thick white paint including providing 3 Nos strips of air force blue colour all as directed. Note : All the required T & P items like ladders, safety belts and helmets etc shall be deemed in the quoted rates. Pole number with location shall be recored in MB
Disconnecting cable connection of LT panel /Feeder Pillor Box of any size and capacity cleaning thoroughly with vaccum cleaner and CRC and shifting care fully to new location , making cable connection for incoming and out going cables along with required cable glands and lugs and foundation work at new location all as specified and directed.
S & F in replacement of PVC insulated heavy duty electric weather proof flat twin core cable with aluminium conductor 1100 Volts grade, cross sectional area 6 Sqmm all as specified & directed by Engineer in Charge.
Allas per item no. 41 here in before but 10 Sqmm
Allas per item no. 41 here in before but 16 Sqmm
S & F in replacement of initial charging battery 12 volts, 180 AH including filling with necessary electrolyte solution having warrentee for 36 month (Minimum) all as specified & directed by Engineer-in-charge. Note: Warrentee certificate issued by manuafcturer' along with purchade voucher shall be submitted by contractor)
S & F in replacement on load change over switch, 800 Amps, 4 pole with steel sheet metal enclosure, panel mounted type with fixing arragement in existing wall angle iron frame 50x50x4mm with welding work and PCC works etc including making electrical connections complete all as specified and directed.
S & F in replacement on load change over switch, 630 Amps, 4 pole with steel sheet metal enclosure, panel mounted type with fixing arragement in existing wall angle iron frame 50x50x4mm with welding work and PCC works etc including making electrical connections complete all as specified and directed.
S & F in replacement on load change over switch, 400 Amps, 4 pole with steel sheet metal enclosure, panel mounted type with fixing arragement in existing wall angle iron frame 50x50x4mm with welding work and PCC works etc including making electrical connections complete all as specified and directed.
S & F in replacement on load change over switch, 200 Amps, 4 pole with sheet metal enclosure, panel mounted type with fixing arragement in existing wall angle iron frame 50x50x4mm with welding work and PCC works etc including making electrical connections complete all as specified and directed.
M&L for detection of HT/LT fault by using fault locator machine highering from civil authority complete all s specified and directed by Engr-in -Charge. Note :- In one length of cable from Panel/DB/Transformer to Panel/Transformer all faults considered as single job complete all as specified and directed. Record generated by Machine shall be submitted by the contractor while claiming payment.
M&L in repairs to phase sequence controler of any capacity & of any make by removing out the burnt wiring from the panel after taking proper electric shut down & disconnecting the cable, checking it thoroughly for working at auto & manual mode and rectifing them, including overhauling of the contractor, replacement of wornout connector,wiring, nuts & bolts,minor part of contactor etc reassembling , re-installation ,testing & commissioning complete all as directed by Engineer-in- charge.
Supply and fixing in replacement of single phase preventer for phase controler all as specified & directed by Engr-in-charge.
Supply and fixing in replacement of single phase preventer for phase controler all as specified & directed by Engr-in-charge.
Supply and fixing in replacement of contactor suitable for phase controler of capacity 100 Amp all as specified & directed by Engr-in-charge.
Supply and fixing in replacement of contactor suitable for phase controler of capacity 160 Amp all as specified & directed by Engr-in-charge.
Supply and fixing in replacement of phase sequence relay suitable up to 200 Amp phase sequence corrector all as specified & directed by Engr-in-charge.
M&L for replacement of Air circuit breaker (ACB) of capacity 800 Amps 4 pole with breaking capacity 50 kA with thermal magnetic release (Mannual drawout type) complete all as specified and directed by Engr-in-Charge. Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor. Machine number with location shall be recored in MB.
S & F in replacement of MCCB, thermal magnetic protection type of 630 Amps ,50 KA, 4 Pole, 415V , Ics=100%Icu, fixed with and including lugs, nuts, bolts, washers, spacers, studs, links etc. testing and commissioning and making all necessary adjustment for fixing of MCCB in panels complete all as specified and directed.Make MCCB :- Legrand / L&T / ABB / C&S as approved by GE
All as per Item No. 58 above but MCCB of rating 500 Amps 36 KA, 4 Pole, 415V
All as per Item No. 58 above but MCCB of rating 400 Amps 36 KA, 4 Pole, 415V
All as per Item No. 58 above but MCCB of rating 350 Amps 36 KA, 4 Pole, 415V
All as per Item No. 58 above but MCCB of rating 250 Amps 25 KA, 4 Pole, 415V
All as per Item No. 58 above but MCCB of rating 200 Amps 25 KA, 4 Pole, 415V
All as per Item No. 58 above but MCCB of rating 160 Amps 25 KA, 4 Pole, 415V
All as per Item No. 58 above but MCCB of rating 100 Amps 25 KA, 4 Pole, 415V
All as per Item No. 58 above but MCCB of rating 63 Amps 16 KA, 4 Pole, 415V
S & F in replacement of MCCB, thermal magnetic protection type of 250 Amps , KA, 3 Pole, 415V , Ics=100%Icu, fixed with and including lugs, nuts, bolts, washers, spacers, studs, links etc. testing and commissioning and making all necessary adjustment for fixing of MCCB in panels complete all as specified and directed.Make MCCB :- Legrand / L&T / ABB / C&S as approved by GE
All as per Item No. 67 above but MCCB of rating 200 Amps 36 KA, 3 Pole, 415V
All as per Item No. 67 above but MCCB of rating 160 Amps 36 KA, 3 Pole, 415V
All as per Item No. 67 above but MCCB of rating 125 Amps 16 KA, 3 Pole, 415V
Clearing away all grass vegetation ,saplings, shrubs, brush wood undergrowth roots and trees not exceeding 30 CM girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance soft/loose soil and getting out including sprinkling anti vegitation chemical for complete area with spray machine complete all as specified & directed.
S & F in replacement sheet metal enclosure suitable for fixing 4 pole MCCB of any capacity mounted type with fixing arragement in existing wall / angle iron frame incl welding work etc including making electrical connections complete all as specified and directed.
santosh electronics
Bharat Sales Corporation
Lalta Prasad vijay kumar Forwarding Agency
YS CONSTRUCTION
SAKSHAM SUPPLIERS BUILDERS
M/s A S Electrical
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .