| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.2 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹31.9 L+₹8,484.60 (0.27%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹34.7 L+₹2.9 L (9.23%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹37.9 L+₹6.1 L (19.2%)Rejected-Finance 59 100 AJIT NAGAR GATE KHERIA AGRA 282008 | AGRA | AGRA | UTTAR PRADESH | 282008 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹38.2 L+₹6.4 L (20.2%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹40.8 L
EMD Value
₹81,500
Closing Date
22 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Arun Kumar, Offg GE
Garrison Engineer West 62 Station Road Agra Cantt
ADDN/ALTN OF BLDG NO. T-01 (PHYSIOTHERAPY DEPT) IN MH AGRA UNDER GE (W) AGRA
2022_MES_529206_2
8012/901/E8
Open Tender
Civil Works
Item Rate
180 days
Ge West Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Ge West Agra
₹81,500
3 Oct 2022
23 Aug 2022
26 Sept 2022
23 Aug 2022
22 Sept 2022
7 Sept 2022
Amount
Dismantling cement ( corrugated /semicorrugated ,etc) sheets in roof covering including L type or J type hooks or cranked bolts etc complete all as specified and directed
S&F pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet for ridges 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
Taking down wooden roof truss exc 4 m but n.exc 8 m compled rafters or trussed beams span all as specified and directed
M&L for MS roof truss (framed trussed, purlins, crane gantries, rails and fasterning including distnace pieces cleats etc confirming to Fe290 grade E-165 complete all as specified & directed.
Dismantling timber scantlings 40 Sq. cm and over in section and in any position complete all as specified & directed.
M & L for cutting holes into or through brick wall built in cement mortar superfacial area not exc 150 Sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
M&L for reinforced cement concrete nominal mix, Type B1, using 20mm grades stone aggregate 1:2:4 as in slab supported on walls, beam, and columns in floors, roof and the like complete all as specified & directed.
M & L for MS TMT bars of 10mm dia and over, dia cut to length bent to shape required including cranking bending spirally, hooking ends and binding with mild steel wire not less than 0.9 mm dia(annealed) complete all as specified and directed by Engr-in-Charge.
Uses and wastage of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished flat surfaces of concrete complete all as specified & directed.
Uses and wastage formwork to edges of concrete flats, treads breaks in floors, window cill, conctete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide complete all as specified & directed.
M&L for RCC type B-1(using 20mm graded stone aggregate), 1:2:4 (Nominal mix) as in foundations, including rafts,footings,foundation beams, plinth beams, plinth bands; bases for columns,etc basement slabs,under reamed piles and mass concrete complete all as specified and directed.
M&L for RCC type B-1 using 20mm graded stone aggregate as in, 1:2:4 (Nominal mix) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for RCC type B-1 , using 20 mm graded stone aggregate 1:2:4 (Nominal mix) in columns, pillars, piers, posts and struts complete all as specified and directed.
M & L for mild steel TMT bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with, in stirrups and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
uses and wastage of formwork to side of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter rough flate finished surfaces of concrete complete all as specified and directed.
Uses and wastage of formwork to side and soffits of floor or roof beam, beam haunchings, girders, bressummers, lintels, cantilevers, shelves incl sup-ports, overhands, etc also splays between floors and beam etc rough flate finished surfaces of concrete complete all as specified and directed.
Uses and wastage of formwork to side of pillars, posts, struts, piers, columns and stanchions etc square, rectangular or polygonal fair finished surfaces of concrete complete all as specified and directed.
S&F mild steel joist channel angle or I sections fixed independently with out connecting plates etc of grade Fe-410-0 & Fe 310-0 complete all as specified and directed..
S&F MS rolled section as in main and cross beams hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc confirming to Fe290 grade E-165 complete all as specified and directed.
M & L for preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone) as in bed block and copping and benching embedding of hold fast etc complete all as specified and directed
Demolition of brickwork built in cement mortar including all quoins arches pillar etc complete all as specified and directed.
Excavation in trenches, in any kind of soil not exceeding 1.50 meter wide and not exceeding 1.50 meter in depth and getting out in soft/loose soil complete all as specified and directed by Engr -in-Charge.
Returning filling in including spreading levelling, watering and well remming in layers not exc 25cm thick complete all as specified and directed by Engr-in-Charge. complete all as specified and directed.
Removing excavated soil n.exc. 50m and deposited where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using stone aggregate) as in foundation complete all as specified and directed.
M&L for brick work with sub class B bricks in cm (1:6) straight or curved on plan exceeding 6.00 mtr mean radius complete all as specified and directed.
Taking down cement plaster on brick or stone surface walls including racking out joints, hacking for key, scrubbing down with water etc.complete all as specified and directed.
M&L for washed stone grit plaster on exterior walls in two layers under layer 12 mm cement plaster 1: 4 with water proofing compound @ 2% by weight of cement ( 1 cement : 4 coarse sand ) furrowing the under layer with scratching tool applying cement slurry on the under layer @ 3 Kg of cement per square metre top layer 15 mm cement plaster 1:1 / 2 : 2 (01 cement 1/2 corse sand : 2 stone chipping 10 mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing the top layer with brushes and water to expose the stone chippings complete all as specified and directed. Note - Payment for providing grooves and water proofing compound shall be made separately.
M & L for forming groove of uniform size 15 mm wide and 15 mm deep in the top layer of washed stone grit plaster as per approved attern using wooden battens naied to the under layer including removal of wooden battens repair to the edgs of panels and finishing the groove complete all as specified and directed.
Supply only liquid water proofing compound
M&L for rendering 10mm thick on faces of concrete surface in CM 1:4 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on any faces of brick work or on concrete surface in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M & L for three coats of white wash on new plastered surfaces of ceiling including preparation of surfaces complete all as specified and directed.
M&L for three coats of white wash on new plastered surface of walls including prepration of surfaces complete all as specified and directed.
M & L for preparation of newly plastered wall surfaces and appling two coat of cement base paint over a coat of primers with alkali resistant priming paint complete all as per specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of weather proof exterior paint (silicon based) over a coat of water based suitable primering as a base course as per manufacturer's instructions complete all as specified and directed.
Dismentling wall and ceiling boards( fibre pulp, insulation etc.) or insulation board /slabs/blanket any thickness including cover fillets complete all as specified and directed.
S & F in repair Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre
M&L for 4 mm thick non asbestos fibre cement building designer boards fixed in ceiling or laid/inserted to timber/GI/aluminun frame complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping, clean and washing down with water to remove dust etc including brushing neat cement slurry with 3 Kg of cement per Sqm complete all as specified and directed
M&L for rubber tiles with fabric backing or insert, plain coloured or marbled topping, matt or glossy, laid in floors with approved adhesive complete all as specified and directed.
M&L for non skid ceramic colour tiles joint free 7 to 8 mm thick (Square /rectangle) area of each tile excedding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and ponted in white or coloured cement to match over 15 mm thick scread bed in cm 1:6 complete all as specified and directed.
M&L for vitrified light shade ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in CM (1:6) for laying floor finishes complete all as specified and directed.
All as per item No-45 but on verticle surfaces such as skirting/dado over 10 mm thich rendering in cm 1:4 complete all as specified and directed.
M&L for glazed ceramic coloured tile 350x250x7mm / 450x350x7mm thick jointed and pointed with white or coloured cement over 10 mm thick rendering in cm 1:4 on vertical surface complete all as specified and directed.
M & L for solid PVC Wall lining consisting of 5mm thick plain but single side prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking off shutters from the frame) area not exc 1.5 Sqm each opening complete all as specified and directed.
All as per item No 50 here-in-before but exc area of opening 1.5 Sqm and not exc 4.00 Sqm each complete all as specified and directed.
S&F anodised aluminium frame for doors, windows ventilators with one or more rebate including joining cleats, screws, for fixing etc complete all as specified and directed.
S&F anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed.
S&F anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws etc complete all as specified & directed.
S&F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified & directed.
S&F aluminium partition of specified aluminium section top rail and middle rail 2.36 Kg/RM, bottom channel 2.59 Kg/RM including aluminium beads rubber gasket glazing pins screws, jointing cleats and 5mm thick frosted glass in upper portion and 12 mm thick prelaminated particle board, exterior grade prelaminated one side with decorative choice lamination and other side balancing white lamination in lower portion complete all as specified and directed.
S&F aluminium anodised grill with mesh size 75 mm and aluminium bar 6 mm XPM type including all accessories such as channels for fixing grill screws etc, aluminium section 15 micron thick anodizing complete all as specified and directed.
S & F galvanized stainless steel wire cloth 0.50 mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tacks wire staples complete all as specified and directed
S&F 12 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination , fixed with screws to timber/ aluminium frame work and sealing edges of board with PVC beading by chemical adhesive complete all as specified and directed.
S&F 4.8 mm thick sheet glass ordinary quality and area of glazing not exceeding 0.50 Sqm in each pane complete all as specified and directed.
S&F 4.8 mm thick figured glass, pinhead, are of glazing exceeding 0.50 Sqm in each pane complete all as specified and directed.
S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F mortice lock, vertical type of size 100 mm with mild steel body 4 lever complete all as specified and directed.
Demolition of Cement concrete (unreinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for 50 mm thick PCC (1:3:6) type C-1 (using 20 mm graded aggregate) as in plinth protection making surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 75 mm thick plain cement concrete Type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in paths, making XPM impressions, complete all as specified and directed.
M&L for hard core of gauge n. exc 63 mm with broken boulders or stone, spread, levelled watered and well rammed in layers n exc 15 cm thick complete all as specified and directed.
M&L for machine pressed coloured chequered tiles of size 25 cm x 25 cm x 25 mm thick set, jointed & pointed in grey cement with pigment over and including 20 mm thick screed in CM 1:6 complete all as specified and directed.
Cutting openings in brick wall built in cement mortar, through brick walls for door, window and other openings or enlarging existing openings, converting window into door opening etc or cutting out defective brick work for under pinning including providing fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc. to store and rubbish at distance not exc 50 m complete all as specified and directed.
S&F Soild PVC door frame of size 50mm x 47mm made out of 5 mm plain coloured PVC sheet, reinforced with MS square tube fixing in opening as per specification and drawing complete all as specified and directed.
S&F Factory made solid PVC moulded door shutter 28 to 30 mm thick(stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specifications & drawings shown in section 8 of SSR Part II complete all as specified and directed.
S&F 15mm dia GI tubes, medium grade with fitting, fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20mm dia GI tubes, medium grade with fitting, fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F gun metal ,globe or gate valve 20 mm bore with iron wheel head ,screwed both ends for iron pipe complete all as specified and directed
S & F 15 mm bore CP Bib taps fancy type cast copper alloy with crutch or butterfly handle sc-rewed down screwed for iron pipe or for brass ferrule and fixed (15mm bore dia of pipe ) complete all as specified and directed.
S & F 15 mm bore CP Stop valves fancy type ( angle valve) cast copper alloy screwed down high pre-ssure with crutch or but terfly handle screwed both ends for iron pipe or for unions and fixed ( 15mm bore dia of pipe ) complete all as specified and directed.
S & F 15mm bore Pillar taps fancy type cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
S&F 15 mm bore brass CP mixer ( wash basin /wall mixer)15 mm bore for mixing hot & cold water screwed down for iron pipe or any type of pipe and fixed in position complete all as specified and directed
S & F Brass chromium plated shower rose, 125mm size with or without swivel joints, any size, including fixing to pipe complete all as specified and directed
S & F PVC connections 600 mm long 15 mm bore with PTMT nuts complete all as specified and directed
S&F glass shelf PTMT fixed with CP brass screws and wooden / plastic cleats ( min wt 300 gm) complete all as specified and directed
S&F Vitreous China wash hand basin, white, flat back, size 550x400mm including brackets , waste pipe,complete all as specified and directed.
S&F 1000 ltr capacity rotational moulded polyethylene water storage tanks with cover & 20mm ball valves high pressure of PTMT with epooxy coated aluminium road & high density plastic ball (cylindrical vertical with closed top) hoisted and fixed in position incl disconecting and removal of existing tank complete all as specified and directed
S&F kitchen sinks made of stainless steel sheets 1 mm thick with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm and bowl size 410mmx330mmx 160mm complete all as specified and directed
S&F vitreous china wash down water closet pan pedestal pattern, white (excluding fixing flushing cistern and flush pipe) complete with seat cover, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminum hinging device complete all as spfd and directed.
S&F in repair vitreous China Orrissa pan with integral foot rest size 580xmmx440mm white with ‘P’ or ‘S’ trap front or back inlet and foot rests any pattern including concrete bedding complete all as specified and directed.
S&F low level flushing cistern of capacity 10 litre, ISI marked, with inlet ball valve , and handle including brackets of complete all as specified and directed.
S&F 125mm dia PTMT Grating with waste hole (minimum weight 40 gm) complete all as specified and directed.
S&F Stainless steel toilet paper holder recessed type complete all as specified and as directed
S & F Chromium plated brass hand ablution health faucet with and including 1.50 mtr long flexible tube, fancy type with necessary brass nuts & rubber washers, covered with chromium plated spring complete all as specified and directed.
S&F soap dish, brass, chromium plated,size 100X60mm, fixed to wall with rawl plugs and chromium plated screws complete all as specified and directed.
S&F vitreous china urinal, half stall type, white (excluding flushing cistern , flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement complete all as specified and directed.
S&F 32 mm waste coupling PTMT (half or full threaded) in basins, urinal etc. with bedded in red lead cement and other end fixed complete all as specified and directed.
S&F 15 mm dia urinal spreader of PTMT any colour for fixing with 15 mm dia pipe complete all as specified and directed.
S&F mild steel chromium plated tubular towel rail 20 mm dia D type 60cm long between flanges fixed in repairs complete all as specified and directed
S&F 110 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed by the Engineer-in-charge.
S & F 110 mm bore dia PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed
S & F 75mm bore dia PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed
S & F PVC (SWR) Bend any radious, 75 mm dia, complete all as specified and directed
S & F PVC (SWR) Junction (Single 'T' ) equal or un equal, 75 mm dia, complete all as specified and directed
S & F PVC (SWR) Gully traps125/110 mm set and jointed with solvent cement complete all as specified and directed
S & F PVC (SWR) Vent Cowl 110 mm dia complete all as specified and directed
S&F 75 mm dia outlet CI floor trap, with grating incl jointing to waste pipe, fixed in cement concrete type B1(1:2:4) complete all as specified and directed.
M&L for Machine cut kota stone 20-25 mm thick as in floor, laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing over and including 20mm thick screed bed in CM ( 1:6) as in floor complete all as specified and directed.
S&F 5.0 cm thick sand stone slabs in sun shades, chajjas, shelves, roof slabs etc n.exc. 2m in length punched dressed on face and along exposed edges, self faced on other side and set and pointed in CM 1:4 complete all as specified and directed.
M&L for providing 35 mm thick precast concrete louvers and jallies (measured solid) including all moulding frame type BO,1:2:4 using 12.5 mm graded stone aggregate set in cement mortar 1:4 complete all as specified and directed
M&L for granite stone 12 to 15 mm thick glazed (table rubbed and polished) fixed as in plateform/vertical surface and the like set in cement mortar 1:4 and pointed with white cement (1:2) using marble dust with admixture of pigment to match the shade of slab over and including screed bed or bedding layer of mortar 10 mm thick in cement mortar 1:4 for laying floor finishes, with rounded edges of stone complete all as specified and directed
M & L for plain cement concrete (1:4:8), type D-2, (using 40 mm graded stone aggregates) as in concrete bed to drain pipes of 150 mm bore laid to falls in trenches in any depth including packing under and haunching against the sides of pipes with concrete after the pipes are laid and tested complete all as specified and directed.
Supply and laying salt glazed stone ware drain pipes 150 mm dia (internal ) grade 'A' laid in trenches and jointed in cement mortar 1:1 including testing complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius in CM (1:4) complete all as specified and directed
M&L for 15mm thick cement plaster in CM (1:4) on fair faces of brick wall Pillar and projection surface even and smooth without using extra cement complete all as specified and directed.
M & L for precast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in precast slabs for covers of manholes including necessary form work and placing of manholes cover in position complete all as specified and directed by Engr-in-Charge.
Cutting into existing manholes for connecting internal dia of pipe 150mm in new drain, making good to pipe and rendering cutting out existing benching for channel (1/2 or 3/4section) in cement concrete 1 : 2 : 4 type B-1 by repairing benching as required complete all as specified and directed by Engr-in-Charge.
Construction of soakage wells exc, in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed masonary with top ring of M-25 Concrete, including intercepting chamber, screen chamber made of brick work in CM, RCC cover slab in M-25/ SFRC Cover interconnecting pipe of RCC/DWC complete filled with brick bats of size 2.4 Mtr x 6Mtr effective depth as per TD Drawing No 576 Sheet No 1/2 & 2/2.
Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/ colour /plaster to match with the existing location spot complete all as specified & directed.
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multi stranded copper conductor cable 1100 volts grade including 1.5sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0 mm thick ISI marked plastic laminated sheet cover for fixing switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
All as per item No-118 here in before but One socket outlet 5/6 Amps on board controlled by one switch complete all as specified & directed.
All as per item No-118 here in before but One socket outlet 5/6 Amps controlled by one switch on same board with other switches complete all as specified & directed.
All as per item No-118 here in before but one socket out let 3/5 pin, 5/6 Amps controlled by one 1way switch on independent board but not below the switch board of light points in same vertical plane complete all as specified & directed.
All as per item No-118 here in before but using 2.5 sqmm PVC FRLS insulated stranded copper cunductor cable and for one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed. NOTE-For item no 118 to 122 -: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (ii) Fittings like switches,sockets,regulators,lamp holders,light foittings shall be measured and paid for separately under appropriate item of schedule A. (iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade)
Supply and fix switch piano, flush type, single pole, 5/6 Amps one way, 230 volts complete all as specified and directed.
Supply and fix switch piano, flush type, single pole, 15/16 Amps one way, 230 volts complete all as specified and directed.
Supply and fix socket outlet, 5/6 Amps, flush type, 5 pin 230 volts complete all as specified and directed.
Supply and fix socket outlet, multi-purpose 3 pin 5/6 Amps and 3 pin 15/16 Amps complete all as specified and directed.
S&F for ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified and directed.
S&F switch, bell push button, single pole, 5/6 Amps, one way, 230 Volts complete all as specified and directed.
Supply and fix electrical bell model city ding dong (Ding dong type) AC, 230 Volts complete all as specified & directed. Make:- Anchor / Cona / Plaza as approved by GE.
Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed.Make: Anchor Cat No. 39797/ 39800 or equivalent as approved by GE.
Supply & fix rotory stepped type electronic fan regulator mini flush type 100 watt 230 Volts complete all as specified & directed.Make: Anchor Cat No.38284/38660 or equivalent as approved by GE.
Supply & fix in replacement, single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps 240 volts IK-08 As per IEC 61439-3 complete all as specified & directed. Make:- Legrand cat part No- 5078 11 & 4085 93 or equivalent model of make Siemens/ Schneider as approved by GE.
Supply and fixing in repair LED Bulb 15 watt, single phase, 230 Volts AC supply suitable for lamp holder complete all as specified and directed. Make :- Havells cat part No-LHLDDEEEML8R015 or equivalent Model of Philips/Bajaj/CG/ Wipro as approved by GE.
Supply & fix surface/wall mounting LED batten 20 watt luminaire having extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with mounting accessories complete with lamp holders fixed to wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No-ENDURALINEARNEOBS20WLED865SPCWH or equivalent Model of Philips/Bajaj/CG as approved by GE.
Supply & fix in repair surface/ ceiling mounting type 34 watt LED luminaire PLUTO NEO PENAL 2X2 environmental friendly new generation aesthetically ultra modern recess mounting with high brightness SMD LEDs as light source with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- PLR34WLED857S or equivalent model of make ,Philips/Bajaj/ Crompton Greaves as approved by GE.
Supply & fix in rerpair outdoor security light LED 36/40 watt luminaire IP 65/66 protection polyster powder coated with pressure die cast aluminium housing and robust construction with reflector cover pre anodised and flat white high transmission acrylic cover or toughened glass, natural white type with electronic driver, connector block etc with internally prewired fixed to building with and including 1.20M long bracket made out of 40mm dia light grade GI pipe bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/MS clamps & 12mm dia bolts, nuts & washers etc and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- ENDURAPEARLNEOSL40WLED757PASYTOPC,Phillips cat part no BRP052 LED 036 CW HP SLA FG S1 PSU GR or equivalent as approved by GE.
Supply & fix in repair surface mounting type bulkhead 10 watt LED luminaire ENDURA RUGBY NEO IP 65 environmental friendly, altra modern energy saving , decorative oval comprising of high brightness LEDs, connector block etc with internally prewired fixed to wall with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- Cat part No FT10WLED857SSYMBOPC or equivalent model of make Philips/ Bajaj/ Crompton Greaves as approved by GE.
Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor .
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for sub main wiring with four runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 10.0 sqmm drawn in and including rigid PVC conduit medium grade of suitable size but not less than 25mm dia with its accessories, concealed type, including two run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 10.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes :- Finished sub main wiring with four runs of 10.0 sqmm cable & two run of 10.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
Taking down distribution boards any size any type including MCB/MCCB of any specifiaction and making good the disturbed surfaces.
Supply and fix MCB DB vertical type 4 way VTPN sheet metal enclosure 415 volts with 100 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable ties for cable manegement suitable for housing MCCB TPN 415 Volts as incommer, IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mouting type double door factory fabricated (without MCB & MCCB but with enclosue blank plate) complete all as specified and directed . Make:- Legrand CAT No.507725 or equivalent model of make Siemens/ Schneider as approved by GE.
Supply and fix MCB DB 4 way sheet metal enclosure triple pole and neutral 415 volts with 100 Amp standard copper bus bar IP-43, IK-09 with metal doors of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mouting type double door factory fabricated as per IEC 61439-3 (without MCB but with enclosue blank plate) complete all as specified and directed . Make:- Legrand CAT No.5076 70 or equivalent model of make Siemens/ Schneider as approved by GE.
Supply and fix MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doors complete all as specified and directed. Make:- Legrand Cat Part No. 5076 11 or equivalent model of make Siemens/ Schneider as approved by GE.
Supply and fix MCB DB sheet metal enclosure factory fabricated double door SPN 4 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doorscomplete all as specified and directed. Make:- Legrand Cat Part No. 5076 10 or equivalent model of make Siemens/ Schneider as approved by GE.
Supply and fix MCCB 4 pole 100 to 125 Amp Icu 16 Kilo Amp and Ics 100% of Icu with adjustable 70% to 100% and thermal magnetic release suitable for fixing in VTPN DB. Make : Legrand cat part 4200 15 to 4200 16 or equivalent model of make Siemens/ Schneider as approved by GE.
Supply & fix Isolator TPN, 4 Pole, 415 Volts, 50 Hz AC Supply , 63 Amps, IP-20 as per IEC 60947-3 ISI marked complete all as specified & directed. Make:- Legrand CAT No. 4065 22 or equivalent model of make Siemens/ Schneider as approved by GE.
Supply & fix Isolator SPN , 100 Amps, 240 volts, 50Hz, IP-20 as per IEC 60947-3 ISI marked complete all as specified & directed. Make:- Legrand CAT No. 4065 04 or equivalent model of make ABB/ L&T/ Schneider as approved by GE.
Supply & fix Isolator SPN , 40 Amps, 240 volts, 50Hz, IP-20 as per IEC 60947-3 ISI marked complete all as specified & directed. Make:- Legrand CAT No. 4065 01 or equivalent model of make ABB/ L&T/ Schneider as approved by GE.
Supply & fix MCB SP, 40 to 63 Amps, 'C' Curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. Make:- Legrand CAT No. 4085 96 to 4085 98 or equivalent model of make Siemens/ Schneider as approved by GE.
Supply & fix MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. Make:- Legrand CAT No. 4085 87 to 4085 95 or equivalent model of make Siemens/ Schneider as approved by GE.
M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanised steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 .
M&L for electrically disconnecting and taking down existing ceiling/Exhaust fans from any hight or in any position from existing bldg and keeping in safe custody for reuse at site after necessary repare/ servicing & painting with one coat of synthetic enable paint and writing of MES/identification No. of fans and re hanging/ re-fixing in original position but including replacement of three core flexible copper conductor cable from ceiling rose to fan connector block of size 0.75 Sqmm and hanging fan clamps, nuts, bolts and rubber reel bush etc & testing for proper functioning complete all as directed at site by Engr-in- Charge
Supply & Laying, testing in repair cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade, with stranded aluminium conductor of size 70 Sqmm 3½ core compele all as specified and as directed. Make :- Havells, Grandlay, Polycab, Finolex
Supplying and laying un-rainforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable.
M&L for sand cushioning dry fine for cable cushioning below and above the cable complete all as specified and directed at site by Engr- in-Charge.
Supply and fixing GI Pipe 40mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed at site,. Make :- TATA, Jindal, Prakash Surya
S&F iron metal body heavy duty exhaust fan 300mm sweep, double ball bearing, copper wound, with louvers, 230 volts, 50 Hz, 5 strar rating including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm strandard copper conductor 3 core flexible cable cord complete all as specified and directed. Make:- Usha/ Bajaj/ Havells
Supply and fix ceiling fans, 1200mm sweep, 230 V, BEE 5 star rated, BLDC type complete with three blade, down rod of length 1 mtr to 2.5 mtr length, standard accessories as supplied by OEM, double ball bearing, copper wound with Squirrel cage induction motor, including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm strandard copper conductor 3 core flexible cable cord complete all as specified and directed. Make :- Havells, Bajaj, Khetain, Usha
VASUNDHARA AND COMPANY
M/S RISHI RAJ AGRAWAL
deva engineers
VISHESH BUILDERS
M/s Rahul Kumar Agrawal
saroj constructions
CREATIVE CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .