Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-Finance KOIL KOIL PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | L1 | Accepted-Finance Accepted being L1 bidder. | |
| 2 | L2₹16.6 L+₹1.6 L (10.8%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than L1 bidder. | |
| 3 | L3₹17.0 L+₹2.0 L (13.4%)Rejected-Finance BROADWAY SHIVPORA SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | L3 | Rejected-Finance Rejected being other than L1 bidder. | |
| 4 | L4₹17.8 L+₹2.8 L (18.5%)Rejected-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L4 | Rejected-Finance Rejected being other than L1 bidder. | |
| 5 | L5₹18.0 L+₹3.0 L (19.8%)Rejected-Finance 184 TENGPUNA PULWAMA PULWAMA PULWAMA JAMMU KASHMIR 192301 UDYAM JK 15 0009999 | PULWAMA | JAMMU AND KASHMIR | 192301 | L5 | Rejected-Finance Rejected being other than L1 bidder. |
| Sl No | Description | Qty | Unit | FG CONSTRUCTION L4 | M/S BASHIR AHMAD AND SONS L5 | MS Ghulam Hassan and Sons L2 | M/s Gh Qadir and Sons L1 | LEO TRADERS L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and installing in replacement of LED flood light 100 watt 230 V AC outdoor/indoor type with thermal management in multiple optics and equipped with IP66 protection, efficacy 120 lm/watt, with impact and corrosion resistant complete with driver and lamp including mounting arrangement i.e. GI bracket bend type made up from GI pipe 40mm size, complete all as specified and directed. | 100 | Each | 2,300 ₹2,30,000 | 2,900 ₹2,90,000 | 1,700 ₹1,70,000 | 2,200 ₹2,20,000 | 1,650 ₹1,65,000 Lowest |
| 2.00 | S&F in replacement of sheet metal steel plug & socket DB SP with metal clad 2 pin & earth plug and socket SPN, 20 Amps, 230 volts AC, surface mounting type complete with one MCB SP, 20 Amps, 10 kA complete all as specified and directed. | 40 | Each | 890 ₹35,600 | 700 ₹28,000 | 500 ₹20,000 Lowest | 500 ₹20,000 Lowest | 800 ₹32,000 |
| 3.00 | S&F in replacement of sheet metal steel plug & socket DB TPN with metal clad 5 pin & earth plug and socket TPN, 32 Amps, 415 volts AC, surface mounting type complete with one MCB TPN, 32-63 Amps, 10 kA complete all as specified and directed. | 40 | Each | 2,900 ₹1,16,000 | 1,500 ₹60,000 | 1,100 ₹44,000 | 1,000 ₹40,000 Lowest | 1,250 ₹50,000 |
| 4.00 | S&F in replacement of wiring for submain with FRLS PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 1.5 sqmm complete drawn in steel conduit fixed on the wall along with 1x 1.5 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified and directed. | 800 | RM | 120 ₹96,000 | 150 ₹1,20,000 | 190 ₹1,52,000 | 111 ₹88,800 Lowest | 150 ₹1,20,000 |
| 5.00 | S&F in replacement of wiring for submain with FRLS PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4 sqmm complete drawn in steel conduit fixed on the wall along with 1x 4.0 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified and directed. | 400 | RM | 190 ₹76,000 | 250 ₹1,00,000 | 200 ₹80,000 | 150 ₹60,000 Lowest | 250 ₹1,00,000 |
| 6.00 | S&F in replacement of flameproof wiring for submain with FRLS PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade complete drawn in steel conduit fixed on the wall along with PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified and directed of following size:-
(a) 4x6.0 RM + 1x6.0 RM | 350 | RM | 290 ₹1,01,500 | 380 ₹1,33,000 | 300 ₹1,05,000 | 211 ₹73,850 Lowest | 500 ₹1,75,000 |
| 7.00 | S&F in replacement of factory made load line DB's double door verticle type made out of CRCA mild steel sheet with insulating material like polyester epoxy quoted surface mounting 6 way VTPN 415 volts, vertical type, surface mounting with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete including MCCB 100 A four pole breaking capacity 16 kA for incoming completeall as specified and directed. | 20 | Each | 7,879.65 ₹1,57,593 | 5,500 ₹1,10,000 | 4,700 ₹94,000 | 4,500 ₹90,000 Lowest | 6,500 ₹1,30,000 |
| 8.00 | S&F in replacement of MCBs, SPN 40-63 Amp, 230 volts, 10 kA rupturing capacity, C curve type complete all as specified and directed. | 80 | Each | 650 ₹52,000 | 650 ₹52,000 | 400 ₹32,000 Lowest | 550 ₹44,000 | 500 ₹40,000 |
| 9.00 | S&F in replacement of MCBs, TPN 4 Pole 40-100 Amp, 415 volts, 10 kA rupturing capacity, B curve type complete all as specified and directed. | 60 | Each | 850 ₹51,000 Lowest | 900 ₹54,000 | 1,300 ₹78,000 | 1,200 ₹72,000 | 1,000 ₹60,000 |
| 10.00 | M&L for fixing of air termination, single pointed aluminium rod 12mm dia and 300mm long on PCC block, complete all as specified and directed.
Note- Work include making of PCC block for mounting of Aluminium Spikes | 120 | Each | 250 ₹30,000 | 200 ₹24,000 | 200 ₹24,000 | 100 ₹12,000 Lowest | 220 ₹26,400 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
8 Oct 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR C/o 56 APO PIN-937208
CERTAIN REPAIR TO FITTING/ FIXTURES TO HANGER AND BLAST PEN AND CONNECTED ITEMS AT AF STN AWANTIPUR
2026_MES_788682_1
GE (AF) AWA-45/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE (AF) AWANTIPUR
₹40,000
Yes
27 Oct 2026
10 Sept 2026
10 Oct 2026
10 Sept 2026
8 Oct 2026
24 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and installing in replacement of LED flood light 100 watt 230 V AC outdoor/indoor type with thermal management in multiple optics and equipped with IP66 protection, efficacy 120 lm/watt, with impact and corrosion resistant complete with driver and lamp including mounting arrangement i.e. GI bracket bend type made up from GI pipe 40mm size, complete all as specified and directed. | 100 | Each | - | - |
| - | S&F in replacement of sheet metal steel plug & socket DB SP with metal clad 2 pin & earth plug and socket SPN, 20 Amps, 230 volts AC, surface mounting type complete with one MCB SP, 20 Amps, 10 kA complete all as specified and directed. | 40 | Each | - | - |
| - | S&F in replacement of sheet metal steel plug & socket DB TPN with metal clad 5 pin & earth plug and socket TPN, 32 Amps, 415 volts AC, surface mounting type complete with one MCB TPN, 32-63 Amps, 10 kA complete all as specified and directed. | 40 | Each | - | - |
| - | S&F in replacement of wiring for submain with FRLS PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 1.5 sqmm complete drawn in steel conduit fixed on the wall along with 1x 1.5 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified and directed. | 800 | RM | - | - |
| - | S&F in replacement of wiring for submain with FRLS PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4 sqmm complete drawn in steel conduit fixed on the wall along with 1x 4.0 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified and directed. | 400 | RM | - | - |
| - | S&F in replacement of flameproof wiring for submain with FRLS PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade complete drawn in steel conduit fixed on the wall along with PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified and directed of following size:-
(a) 4x6.0 RM + 1x6.0 RM | 350 | RM | - | - |
| - | S&F in replacement of factory made load line DB's double door verticle type made out of CRCA mild steel sheet with insulating material like polyester epoxy quoted surface mounting 6 way VTPN 415 volts, vertical type, surface mounting with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete including MCCB 100 A four pole breaking capacity 16 kA for incoming completeall as specified and directed. | 20 | Each | 4 | ₹80 |
| - | S&F in replacement of MCBs, SPN 40-63 Amp, 230 volts, 10 kA rupturing capacity, C curve type complete all as specified and directed. | 80 | Each | 4 | ₹320 |
| - | S&F in replacement of MCBs, TPN 4 Pole 40-100 Amp, 415 volts, 10 kA rupturing capacity, B curve type complete all as specified and directed. | 60 | Each | 5 | ₹300 |
| - | M&L for fixing of air termination, single pointed aluminium rod 12mm dia and 300mm long on PCC block, complete all as specified and directed.
Note- Work include making of PCC block for mounting of Aluminium Spikes | 120 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
BOQ_884041.xls
BOQ • 0.29 MB
Tender45.pdf
Tender Documents • 1.68 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .