Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAccepted-AOC 15 BOH ROAD DEFENCE ENCLAVE AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹36.2 L+₹27,404.40 (0.76%)Rejected-AOC WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC OTHER THAN LOWEST | |
| 3 | L3₹37.7 L+₹1.8 L (5.03%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN LOWEST | |
| 4 | L4₹40.1 L+₹4.2 L (11.8%)Rejected-AOC VILLAGE POST JAGANOO TEHSIL UDHAMPUR JAGANOO UDHAMPUR1 UDHAMPUR JAMMU KASHMIR 182124 UDYAM JK 22 0011509 | UDHAMPUR | JAMMU AND KASHMIR | 182124 | L4 | Rejected-AOC OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹70,800
Closing Date
19 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Dhar Road Udhampur
GE Army Dhar Road Udhampur
PROVISION OF CERTAIN SANCTIONED WORKS AT DHAR ROAD UDHAMPUR
2020_MES_395139_3
8066/NIT-46/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
GE Army Dhar Road Udhampur
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
GE Army Dhar Road Udhampur
₹70,800
Yes
8 Mar 2021
6 Jan 2021
21 Jan 2021
6 Jan 2021
19 Jan 2021
7 Jan 2021
6 Jan 2021 - 7 Jan 2021
60 days
Amount
Surface excavation not exc 30 cm deep and avg 15 cm and getting out in hard/dense of soil all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard / dense soil all as specified and directed.
Excavation over areas n exc 1.5 m in depth and getting out in soft/loose soil all as specified and directed.
Excavation in post hole each n exc 0.5 cum getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm, watering and removing surplus soil to a distance n exc 50m and making good surface complete all as specified.
M&L for PCC 1:4:8, Type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified.
M&L for brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified.
M&L for brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified.
M&L for brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM (1:3) complete all as specified.
M&L for brick work with sub class 'B' st or curved on plan to any radious in half brick thick walls builts in cement mortar 1:4 complete all as specified
M&L for 75mm thick cement concrete type D-2 (1:4:8) using 40mm graded stone aggregates as in sub base of flooring all as specified.
Returning filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm all as specified.
Removing excavated material exc 250 M and not exc 500m and deposited where directed all as specified.
M&L for 15 mm thick cement plaster in cement mortar 1:6 on brick or concrete surface etc. on walls finished even and smooth without using extra cement, all as specified .
M&L for 15 mm thick cement plaster in cement mortar 1:4 on brick or concrete surface etc. on walls finished even and smooth without using extra cement, all as specified .
M&L for 15 mm thick rendering on fair faces of brick work or cement concrete surfaces in cement mortar 1:4, finished fair and even without using extra cement incl mixing of water proofing compound complete all as specified. (Note: Water proofing compound shall be measured and paid for separately)
M&L for 15 mm thick rendering on fair faces of brick work or cement concrete surfaces in cement mortar 1:6, finished fair and even without using extra cement incl mixing of water proofing compound complete all as specified. (Note: Water Proofing compound shall be measured and paid for separately)
Supply only liquid water proofing compound (Makes :Pidilite Industries / Impermo /Snowcem India Ltd / Sika )
M&L for 10mm thick cement plaster on brick or concrete surfaces, as in ceiling / facia / chajja etc. in cement mortar 1:3 finished even and smooth without using extra cement, all as specified .
M&L for glazed ceramic white tiles 350x250x 7mm thick on vertical surfaces of walls, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 10mm thick rendering in CM (1:4) backing of wall tiles such as dado/skirting in vertical surface complete all as specified and as specified.
M&L for Non skid ceramic coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM (1:4) complete all as specified
M&L for Non skid ceramic coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM (1:4) complete all as specified
M&L for glazed ceramic coloured tiles 7mm thick on vertical surfaces of walls area of each tile not exc 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick rendering in CM (1:4) backing of wall tiles such as dado/skirting, risers to steps etc complete all as specified and as specified.
M&L for Non skid ceramic coloured tiles 7-8mm thick on vertical surfaces of walls area of each tile exc 0.06 sqm but not exc 0.09 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 10mm thick rendering in CM (1:4) backing of wall tiles such as dado/skirting etc complete all as specified and as specified.
M&L Vitrified tiles 10 mm thick (square/ rectangular) polished of light shade, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed set in CM 1: 4 complete all as specified and as specified.
M&L Vitrified tiles 10 mm thick (square/ rectangular) polished of light shade, area of each tiles not exceeding 0.36 sqm on vertical surfaces of walls, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick rendering in CM (1:4) backing of wall tiles such as dado/skirting, risers to steps etc complete all as specified and as specified.
M&L for preparing new surfaces and applying three coats of white wash on wall complete all as specified.
M&L for preparing new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer, complete all as specified
M&L for preparing new surfaces and applying two coats of white wash on ceiling surfaces complete all as specified.
M&L for preparation of new wooden or wood based surfaces exceeding 10 cms in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, all as specified.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coasts of synthetic enamel paint over a coat of red oxide primer complete all as specified.
S&F factory made solid panel PVC door shutter 30 mm thick ( style ) consisting of frame made out of mild steel tubes for top and bottom rails . Mild steel frame shall be covered with heat mounded plain cover PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail , lock rail and bottom rail on either side and gap insert for top rail and bottom rail ; Paneling of plain colour PVC sheet to be fitted in the mild steel frame welded /sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement supplying and fixing in the frame at site as per specification clause No 8B.1 to 8B.10 and drawing on page No 146 of MES SSR-2010 Part-II.
S&F factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specification and drawing on Page No 150 MES SSR-2004 Part-II and as directed by the Engr- in-Charge.
S&F factory made, 35mm thick 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the side of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, 35 mm thick complete, all as specified and directed by Engr-in-Charge.
S&F factory made, 2nd class hard wood, 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass / gauge etc. (without sash bars) edges or framing plain, chamfered or rounded fitted with cut or mitered beads for securing glass etc. size of members of shutters as specified in SSR Part - I section 8.20 (a), all as specified and directed by Engr-in-Charge
S&F pressed steel frames of size 125x60mm, made of 1.25mm thick sheet, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate incl filling hollow of frame with plain cement concrete type B0 (1:3:6 ) using 12.5mm graded aggregates complete all as specified as directed.
S&F pressed steel frames of size 105x60mm, made of 1.25mm thick sheet, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate incl filling hollow of frame with plain cement concrete type B0 (1:3:6 ) using 12.5mm graded aggregates complete all as specified as directed.
S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, 300 mm long.
S&F aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt, all as specified .
S&F aluminium alloy butt hinges 100mm long with galvanised mild steel hinge pin type C 21.
S&F aluminium handles cast type, anodised, 150 mm size complete, all as specified .
S&F MS 150mm long ordinary rat tail rod pattern spring incl roller and plate complete all as specified
S&F steel windows made up of box steel section of 16 gauge MS sheet outer frame, shutter frame and centre frame with outer side glazed shutter and inner side wire gauged shutter fixed as shwon in drg consisting with two nos pintol hinges 75mm long, two Nos stove enemaled tower bolts 150 mm long and one No steel handle, deovitailed or welded each panels complete with necessary cleats and stopers all as specified as directed.
S&F steel ventilator made up of box type steel section of 16 gauge MS Sheet frame, fixed type suitable to fix half portion wire cloth and half portion glass with suitable MS beading or flat or oil putty as shown in drawing No CE UZ/TD/1302/2009 sheet 1/3 to 3/3 fixed complete all as specified and directed. (MS Gaurd bar/grill work will be measured and paid separately).
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing; frame work for water tanks and similar work conforming to Fe 290 Gde-E-165 all as specified .
S&F MS work in bands, straps, supports or stays for rainwater, ventilating pipes, incl bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe 290 Gde-E-165
S&F sheet glass ordinary quality (frosted) and glazing with oil putty in square n. exc 0.50 Sqm in each pane 4mm thick all as specified.
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanised wire staple all as specified.
M&L 75 mm thick hard core of broken stones and boulders of gauge n exc 63mm, deposited, spread and levelled in layeres n exc 15cm thick watered and rammed to true surface all as specified as directed.
M&L for 50 mm thick plain cement concrete type C2 ( 1:3:6) using 40 mm graded aggregate as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) finished even and smooth at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight all as directed at site.
S&F 15mm bore steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings all as specified.
Re-fixing only 15mm bore steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings
S&F 20 mm bore steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings
S&F 25 mm bore steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings
S&F Bib taps, chromium plated with crutch or butterfly handle screwed down for iron pipe or for brass ferrule and fixed for bore of pipe 15 mm, all as specified.
S&F Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 20 mm bore and fixed, all as specified and directed
S&F Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 15 mm bore and fixed, all as specified and directed
S&F Stop valve/Angle valves 15mm bore dia or pipe, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S&F vitreous china bowl urinal flat back, size of 465 × 355 × 265 mm with grating and union for discharge pipe all as specified and directed
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm long complete all as specified and directed
S&F PVC connections 15 mm size with PTMT nuts of length 600 mm long complete all as specified and directed
S&F vitreous china Wash basin white type of size 550x400 mm including CP waste fitting & waste pipe etc with sutiable fixing arrangement to wall complete all as specified and directed.
S&F Pillar taps, cast copper alloy, with capstan heads , chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm and fixed in repairs, all as specified.
S&F Waste coupling, 32mm dia, but suitable for urinals of PTMT (half or full threaded) .(Minimum weight 32mm-45gms)complete all as specified.
S&F Vitreous china squatting pan of pattern Orissa Pattern size 580x 440 mm white with ‘P’ or ‘S’ trap , front or back inlet but excluding flushing cistern and flush pipe including placing in position in floor and embedded in cushion of PCC 1:7:12 type E-1 and finishing the top surfaces to match with the existing flooring..(Make: - Hindware/ Parryware/ Johnson)
M&L Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) white including 'P' or 'S' trap, complete all as specified.
S&F PVC (Plastic polymer Cistern) valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete including taking down by dismantling the existing unserviceable cistern of any description.(Make: - SLIMLINE (ECONOMY) with front knob of Parryware or equivalent in Hindustan Sanitary ware)
S&F PVC (SWR) pipes, 110 mm external dia double socketed in any length with rubber joints, fixed to walls or laid in trenches with PVC brackets/clips complete all as specified.
S&F PVC(SWR) bends suitable for 110 mm external dia complete all as spd
S&F PVC (SWR) junction single, (single T) equal or unequal of 110mm dia
S&F PVC (SWR) pipes, 75 mm external dia double socketed in any length with rubber joints, fixed to walls/under floor with PVC brackets/clips including pipe under floor will be coverd in PCC 1:3:6 complete all as specified.
S&F PVC (SWR) bends suitable for 75 mm external dia complete all as specified
S&F PVC (SWR) junction single, (single T) equal or unequal of 75mm dia complete all as specified.
Add to item No 70 if provided with acess door complete all as specified.
Add to item No 73 if provided with acess door complete all as specified.
S&F PVC (SWR) 75mm vent cowl complete all as specified.
S&F PVC (SWR) 100mm vent cowl complete all as specified.
S&F PVC (SWR) floor trap 75mm , with grating incl jointing to waste pipe fixed in cement concrete type B1 (1:2:4).
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity 500 litres all as specified in SSR Part-I.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity 1000 litres all as specified in SSR Part-I.
S&F Ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or fixed of size 20 mm bore, (Min Wt 20mm- 210 gms)
S&F 20mm PVC nipple suitable for HDPE water tank (Min Wt 20mm-45gms) complete all as specified.
S&F 15mm PVC nipple suitable for HDPE water tank (Min Wt 15mm-38gms) complete all as specified.
S&F PVC waste pipe 800mm long suitable for 32mm dia waste coupling complete all as specified.
M&L for reinforcement cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, roof beam and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete, all as specified.
M&L for 40 mm thick damp proof course to horizontal or vertical surfaces including necessary formwork in cement concrete 1:2:4, type B-0, using water proofing compound, complete all as specified. NOTE: Water proofing compound will be measured and paid for separately under respective item of BOQ.
M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
M&L mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
M&L for providing precast cement concrete type B1, 1:2:4 (using 20mm graded stone aggregates) as in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings kneelers, apex stones, pier caps, columns, posts, boundary pillars, weatherings, throating etc. and setting in CM 1:4 complete with joints to match complete all as specifed and directed
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F rolled mild steel work as in main and cross beams, hip and jack rafters, purlins where connected to common rafter and running rails and guides for siliding doors, fixed with angle cleat or other connecting plates conforming to Fe-410-W(Gde-E-250) quality-B all as specified and as direceted by Engr-in-Charge.
S&F rolled mild steel sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates conforming to Fe-410-W(Gde-E-250) quality-B all as specified and as direceted by Engr-in-Charge.
S&F MS powder coated decorative mild steel curtain rod of 25 mm dia with brackets both side of globe all as specified and directed by Engr-in-charge.
S&F stainless steel soap dish fixed to plugs chromium plated brass screws, all as specified.
S&F Tubular Towel rail 20mm dia, D type, 60cm long between flanges of brass chromium plated fixed with and including chromium plated brass screws and wooden / plastic cleats all as specified.
S&F in repair Tubular Towel rail 20mm dia, D type, 60cm long between flanges of brass chromium plated fixed with and including chromium plated brass screws and wooden / plastic cleats all as specified.
S& F Jet spray suitable for EWC complete all as specified and directed.
S& F CP health faucet complete all as specified and directed.
S&F CP Shower rose 125mm size with 300mm long CP arm complete all as specified and directed.
S&F concealed stop valves fancy type, chromium plated, cast copper alloy, with long shank and cup screwed for iron pipe or for unions of bore dia 15mm and fixed, all as specified.
S&F PVC (SWR) multy floor trap 75mm , with grating incl jointing to waste pipe fixed in cement concrete type B1 (1:2:4) all as specified.
S&F corner glass shelf 200 mm(brass brackets) complete all as specified and directed.
S&F Shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum wight 300 grms)complete all as specified.
S&F mild steel (50x50x6) Fe 410-W(Gde-E-250) quality - A joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated)
S&F galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured
M&L for preparation of old painted steel surfaces of any discription, applying two coats of syntetic enamel paint over one coat of red oxide, zinc chrome primer complete all as specified
M&L machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment over and including 25mm thick sand cushioning layer complete all as specified
M&L machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment over and including 25mm thick sand cushioning layer complete all as specified
M&L 100mm thick PCC (1:4:8) type D-2 using 40mm graded aggregate as in sub base of interlocking tiles complete all as specified as directed.
M&L for pre cast cement concrete block masonry 1:3:6, type C-1, using 20mm graded stone agg as in kerb stone, made to shape and size as directed and set and jointed in cement mortar 1:3 including necessary excavation and earth work and removing surplus soil to distance not exceeding 50 mtr complete all as specified.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed,
M&L for prepration of new or previously untreated concrete surfaces of any description over 10 cm girth or width , not otherwise described and applying two coats of synthetic enamel paint over a coat of primer all as sppecified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping, cleaning and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 Kg of cement per sqm complete all as specified.
Taking down cement plaster including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms counter type wash hand basin and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including15mm thick screed bed in cement mortar (1:4) complete all as specified.
M&L for taking down and refixing in same opening shutters of any description exc 2 Sqm each complete all as specified.
M&L for providing & fixing false ceiling with gypsum based ceiling tiles and frame work (with aluminium foil on one side) of size 595x595 mm of thickness not less than 9 mm incl GI powder coated frame angle/tee grid frame work for ceiling with following specifications (a) S7F angle of side 25x25x1 mm powder coated (b) 25x25x1 mm GI powder coated at bottom tee as in main member (c) 25x25x1mm thick GI powder coated at bottom tee as in cross members (d) S&F 1.6mm dia GI wire suspenders alongwith adjustable clamps to maintain levelling incl fixing to ceiling fasteners as per manufacturer's instructions complete. Make: VINYL TOUCH of LaGyp (LAFARGE) or equivalent in GYPROC (SAINT GOBAIN)
M&L for preparing of old wall surfaces and applying one coat of OBD complete all as specified.
M&L for preparing new plastered surfaces of walls and applying two coats of OBD over a coat of alkali resistant primer of any description of approved tint complete all as specified.
Preparing new plastered surfaces of walls and applying two coats of weather coat paint as on facia, fins, chajja border, columns, drops, parapets, etc. over a coat of painting primer, complete all as specified
M&L for providing precast cement concrete louvers and jalies, 25mm thick, set in cement mortar 1:4 (measured solid) incl mouldings complete all as specified.
M&L for providing RCC type B1, 1:2:4 (Using 20mm graded stone aggregate) as in lintel beam on pre cast RCC Jali and like, incl necessary form work complete all as specified.
M&L for anodised aluminium partition wall with aluminium frame size 100x44x1.48mm thick partition duly fitted with peosprane rubber beading, tinted glass panes 5.5 mm nominal thickness or 12mm thick prelaminated melamine faced both side decorative exterior grade type II particle board panels complete all as specified and directed all as specified.
M&L for 150 mm thick lean cement concrete type B-2, 1:2:4 (using 40mm graded aggregates)as in sub base chequered finished complete all as specified.
M&L providing cement concrete type B1, 1:2:4 using 20mm graded aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, like including weathering, slightly rounded or chamfered angles and throating, as directed.
M&L providing precast cement concrete type B1, 1:2:4 using 20mm graded aggregate set in CM 1:4 in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified.
M&L Cement concrete type B1, 1:2:4 using 20mm graded stone aggregate in surface channels and drains.
M&L 150mm bore SGSW drain pipes grade 'A', laid in trenches and jointed complete all as specified.
M&L for cement concrete bed type D2, 1:4:8 using 40mm graded stone aggregate for 150mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified.
Construction of soakage well of size 1.2 m dia x 3.0 m depth comprising of excavation in any type of soil, foundation in PCC 1:3:6 walls of honeycomb masonry with brick work all as shown in drg No CE/TDT1202/2003 top ring of M-25 concrete including intercepting chamber and screen chamber made of brick mansonry in cement mortor 1:4, RCC cover slabs in M-25/SFRC covers, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as shown on drawing and as directed
Construction of soakage well of size 1.8 m dia x 3.0 m depth comprising of excavation in any type of soil, foundation in PCC 1:3:6 walls of honeycomb masonry with brick work all as shown in drg No CE/TDT1202/2003 top ring of M-25 concrete including intercepting chamber and screen chamber made of brick mansonry in cement mortor 1:4, RCC cover slabs in M-25/SFRC covers, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as shown on drawing and as directed
Construction of septic tank with cover slab, RCC M-25 (Design Mix) for 10 users with brick work in CM 1:4 (with top slab at gropund level) incl necessary excavation and earth work in any type of soil and disposal of surplus soil as directed, RCC man hole covers with angle iron welded frame, CI vent shaft with CI cowel complete all as shown on drawing and as specified and directed by Engr-in-Charge.
Construction of septic tank with cover slab, RCC M-25 (Design Mix) for 25 users with brick work in CM 1:4 (with top slab at gropund level) incl necessary excavation and earth work in any type of soil and disposal of surplus soil as directed, RCC man hole covers with angle iron welded frame, CI vent shaft with CI cowel complete all as shown on drawing and as specified and directed by Engr-in-Charge.
Cutting into existing manholes for connecting new drains, of 150 mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required, complete all as specified.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, incl forms, moulds,mitred/stopped ends etc complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
Demolition of brickwork of stone/boulder masonry, build in lime mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles
Demolition of cement concrete of any description complete all as specified.
Dismantling water tanks 500/1000 Ltrs capacity and removing to store.
Dismantling wrought iron or mild steel work of any description not otherwise provided.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 sqm each complete all as specified.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 sqm and not exceeding 4.0 sqm each complete all as specified.
M&L for 25 mm thick plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in floors finished rough all as specified.
M&L for 15 mm thick cement plaster in cement mortar 1:4 on roof surfaces finished even and smooth without using extra cement, using water proofing compound including taking down existing roof treatment of any description and any type all as specified. (Note: Water proofing compound shall be measured and paid for separately)
M&L for providing and laying 40mm thick PCC (1:2:4) using 20mm graded agg with WPC complete all as specified and directed by Engineer-in-Charge. (Note: Water proofing compound shall be measured and paid for separately)
M&L for priming the roof surface with bituminous primer conforming to IS-3384 @ 0.30 ltrs/Sqm and applying a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20 Kg/Sqm and thereafter provide polymeric water proofing membrane (five layered) of weight not less than 3 Kg/Sqm with centre layer core of 90 micron high molecular density polyethylene film followed by another coat of semi hot blown 85/25 grade bitumen @ 1.20 Kg/Sqm blinded with fine sand in dry condition @ 0.50 Kg/Sqm all as specified (Make of polymeric water proofing membrane : M/s IWL India Ltd/M/s STP Texas Ltd/Bengal Bitumen)
Complete removal all exsting old plastered surfaces of walls and applying two coats of cement base paint all as specified and dircted by Engr In Charge
Complete removal all exsting old plastered surfaces of walls and applying two coats of OBD paint all as specified and dircted by Engr In Charge.
Complete removal incl preperation old decorated wall surfaces applying two coats of white wash on wall complete all as specified.
Complete removal incl preperation old decorated of ceiling surfaces applying three coat of white wash complete all as specified.
Preparation of new steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, all as specified.
Preparation of old steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint, all as specified.
Preparation of old steel and iron surfaces not exceeding 10 cms width or girth and applying one coat of synthetic enamel paint, complete, all as specified.
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, all as specified.
Taking up or down steel tubing with connections for cleaning for refixing complete of bore 15mm, all as specified .
S&F in repair Bib taps, long body, fancy type, chromium plated with crutch or butterfly handle screwed down for iron pipe or for brass ferrule and fixed for bore of pipe 15 mm all as specified.
S&F in repair CP Pillar tap, fancy type chromium plated with crutch or butterfly handle screwed down high pressure with or without letterd hot or cold with long screed shanks and fly nuts screwed for iron pipe all as specified.
S&F in repair CP Stop/angle valves 15mm bore dia or pipe, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repair stainless steel soap dish fixed to plugs chromium plated brass screws, all as specified.
Dismantling of cast iron or PVC pipes including all fittings and accessories, 100/75 mm dia and in any position all as specified.
S&F in repair PTMT grating round 100 mm size, all as specified.
S&F in Repair PVC waste pipe 800mm long suitable for 32mm dia waste coupling complete all as specified.
S&F in repair MS powder coated decorative mild steel curtain rod of 25 mm dia with brackets both side of globe all as specified and directed by Engr-in-charge.
Dismantling of plain, corrugated or semi corrugated AC sheeting, of any description, roof coverings all as specified.
Cutting chases for concealed water tubing or concealed conduit etc. cutting exceeding 20cm in girth and making good in cement mortar 1:3 complete all as specified.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons, dado,skirting etc.
M&L for machine cut kota stone slab 20-22 mm thick as in floor over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete incl screed bed or bedding layer of mortar 20mm thick in cement mortar 1: 4 for laying floor finishes complete all as specified and directed.
M&L, Kota stone slab 20-22mm thick as in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 10 mm thick 1:3 cement mortar all as specified
Dismantling wall and ceiling board (fibre, pulp, insulation etc or insulation boards/ slabs/blankets any thickness incl cover fillets complete all as specified and directed.
Taking down carefully aluminium / copper point wiring (light, fan, socket or power ) complete, including fittings and fixtures such as switches, ceiling roses, light fittings, regulators, sockets etc, removing materials to store, or keeping in safe custody for offering credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., all as specified and as directed.
M&L for concealed point wiring on wall and ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white/ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screws and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of paris/putti or distemper / colour wash with same as per existing colour surfaces all as specified and directed by Engineer-in-Charge for one light/fan point controlled by one switch
All as per item No 175 above but for one switch socket outlet point 3 pin 5 Amps on Independent board with one way switch complete.
All as per item No 175 above but for one switch socket outlet point 3 pin 5 Amps on same board with one way switch complete
All as per item No 175 above but for one power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S&F switch piano flush type (ISI marked), single pole, one way 5 Amps, 240 Volts complete all as specified and directed. Make : Anchor/Cona/Havells
S&F switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts complete all as specified and directed. Make : Anchor/Cona/Havells
S&F socket outlet 3 pin, 6 Amp piano flush type complete all as specified and as directed. Make : Anchor/Cona/Havells
S&F socket outlet, 2 in 1, 3/5 pin 6 / 16 Amp, piano flush type complete all as specified and directed. Make : Anchor/Cona/Havells
S&F switch socket combination 3 pin 5 Amps multi pin flush type. Make : Anchor/Cona/Havells
S&F ceiling rose surface bakelite 65x50mm 3 terminals. Make : Anchor/Cona/Havells
S&F of PVC Lamp holder Insulated body bracket holder /Angle holder. Make : Anchor/Cona/Havells
S&F switch socket combination 5/15Amps multipin flush type. Make : Anchor/Cona/ Havells
S&F fan regulator, electronic, step type, 80 watt socket size suitable for single phase AC, 240 volts, 50 Hz, rotary type all as specified and as directed. Make : Anchor/Cona/Havells
Taking down old / unserviceable fittings of any type, make and wattage complete all as specified and directed.
S&F wall mounted LED batten 18/20 Watt with 01 No LED tube rod, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver including dismantling and taking down unsv FTL fitting T8 any type complete all as specified and directed. Make: Crompton Cat Part No LDL-20-CDL or equivalent in Philips/Wipro
S&F wall mounted LED batten 18/20 Watt with 01 No LED tube rod, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete all as specified and directed. Make: Crompton Cat Part No LDL-20-CDL or equivalent in Philips/Wipro
S&F LED bulk head 6.5K/3K fitting, 1 x 9 watt including lamp, with new generation energy saving & environment friendly long life including all accesssories conforming to cat part No SSK BH 9W Make of `SYSKA' including taking down old u/s fitting all as specified and as directed.
Taking down old sub main wiring of any size any type complete all as specified and directed.
Sub main wiring complete with two runs of 6 sqmm FRLS single core PVC insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade, multistranded with copper conductor drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories concealed to walls / roofs / floors etc., and including provision of PVC insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade 4 sqmm for earth continuity conductor and making good the disturbed surfaces also matching the exisiting surfaces all as specified and as directed by Engr-in-Charge. (For measurement purpose 2 run of 6 sqmm + 1 run of 4 sqmm). Make:- Havells/Plazza/Polycab
Sub main wiring complete with two runs of 4 sqmm FRLS single core PVC insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade, multistranded with copper conductor drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories concealed to walls / roofs / floors etc., and including provision of PVC insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade 2.5 sqmm for earth continuity conductor and making good the disturbed surfaces also matching the exisiting surfaces all as specified and as directed by Engr-in-Charge. (For measurement purpose 2 run of 4 sqmm + 1 run of 2.5 sqmm). Make:- Havells/Plazza/Polycab
Disconnecting from mains and Taking down old unsv sheet metal enclosures of MCB any type and capacity including unsv MCBs.
S & F double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed.Make Legrand/Scheinder/L&T
S&F SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way, confirming to IS 13032 & 8623 complete all as specified and directed. Make: Schneider (Electric)/Legrand/L&T .
S&F SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 2 way, confirming to IS 13032 & 8623 complete all as specified and directed. Make: Schneider (Electric)/Legrand/L&T.
S&F MCB SPN, 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make: Schneider Electric/Legrand/L&T.
S&F MCB Single pole & neutral 240 volts,63 Amps 10 KA all as specified and as directed.Make :- Legrand/Scheinder/L&T
S&F MCB single pole, 240 volts, 6 to 32 Amps 10 KA all as specified and as directed by Engr-in-Charge.Make :- Legrand/Scheinder/L&T
S&F in replacement of AC/ geyser box by sheet steel enclosure in single pole neutral fitted with two pin and earth plug and socket complete with MCB SP 240 volt 20 Amps C series of suitable rating complete all as specified and directed . Make Legrand/Scheinder/L&T
S&F Geyser (water heater) of 25 Ltrs capacity having 5 star rating 240 volt fixing with the help of washer grouting bolts/ nuts etc alongwith connection of geyser inlet and outlet by PVC flexible connection pipe with two brass adopter for carrying hot water as specified and directed Make Havells or eqvts of bajaj /philips/crompton
S&F of exhaust fan 450 mm sweep, 1400 RPM 230 volt, single phase with louver and connection with 3 core suitable size copper conductor including making hole of required size and making good the disturbed surface complete all as specified and directed. Make -Crompton/ Bajaj/Khaitan/Havells
S&F of exhaust fan 300 mm sweep, 900 RPM 230 volt, single phase with louver and connection with 3 core suitable size copper conductor including making hole of required size and making good the disturbed surface complete all as specified and directed. Make: Crompton/ Bajaj/Khaitan/Havells
S&F ceiling fan complete with electronic type regulator and accessories 230 V, 1200mm sweep complete with down rod. Make: Havells/Bajaj/Crompton etc
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to galvanised earth lead wire 4.00mm GI earth continuity conductor including 15 mm bore pipe Light grade for protection of lead by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel connected to maint switch control board upto 7.5 mt away from earth electrode all as shown as per plate No 05 of Sl part - I including necessary earth work, PCC 1:3:6 type C1 chamber, RCC cover slab of 50 mm thick 1:2:4 with 8 mm CTD 140 mm C/C with suitable handle, watering pipe 20 mm dia light grade pipe with funnel, charcoal, salt and testing on completion and including taking old unserviceable earthing with connected items all as specified and directed by Engr-in-Charge including taking down old/unsv earthing.
M&L for dry sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M & L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable all as specified and directed.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
Taking out old unserviceable underground cable of the10 sqmm 2 core size or service connection and making good the disturbed surface to original position complete all as specified and directed
Supply, laying, testing and commissioning LT cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm, 2 core in trenches, duct/ laid on wall etc incl. suitable size lugs, thimbles,GI nuts and bolts, washers, insulation tape etc complete all as specified and directed. Make of cable : Havells, Polycab, Nicco, Gloster,Finolex
Supply, laying, fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 6 sqmm 2 core with required aluminium cable lugs all as specified and directed. Make of cable : Havells, Polycab, Nicco, Gloster,Finolex
Supply and laying in trenches/floors or fixed to Pole/Wall GI pipe light grade with fittings of size 40 mm bore for protection of cable including dismantling existing pipe complete all as specified and directed by the Engineer-in-Charge.
DAVINDER SINGH
TARUN BUILDERS
NARESH KUMAR KHAJURIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .