Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹87.8 LAccepted-AOC | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹93.6 L+₹5.7 L (6.52%)Rejected-Finance | L2 | Rejected-Finance Other than Reasonable | |
| 3 | L3₹96.0 L+₹8.1 L (9.25%)Rejected-Finance CANADA BUILDING 224 DR D N ROAD FORT MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L3 | Rejected-Finance Other than Reasonable | |
| 4 | L4₹98.3 L+₹10.4 L (11.9%)Rejected-Finance | L4 | Rejected-Finance Other than Reasonable | |
| 5 | L5₹99.6 L+₹11.7 L (13.4%)Rejected-Finance | L5 | Rejected-Finance Other than Reasonable |
Tender Value
₹1 Cr
EMD Value
₹1.8 L
Closing Date
13 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Jorhat
HQ CWE (AF) Jorhat, Rowriah, Assam -785005
83933/E8 REINSTALLATION OF MAFI LIGHTS AT AF STATION JORHAT UNDER GE (AF) JORHAT
2021_MES_475432_2
83933/E8
Open Tender
Electrical and Maintenance Works
Item Rate
GE (AF) Jorhat
Please refer tender documents
5 documents required · 5 mandatory
₹1,000
Yes
GE (AF) Jorhat
₹1.8 L
Yes
30 Dec 2021
22 Nov 2021
18 Dec 2021
22 Nov 2021
13 Dec 2021
29 Nov 2021
60 days
Amount
The complete scope of the work related shall be got executed under guidance/ supervision of USERS. The contractor shall ensure that the operational requirement of USERS are not affected during execution and the hardware and software is integrated with the existing system. Contractor shall ensure that complete Air Field lighting work including DGPS survey shall be got executed through the specialist agency namely M/s TATA POWER SED/ M/s AMA Pvt Ltd/ M/s Honeywell Automation Ltd/ M/s Three D Integrated Solutions Ltd/ M/s YPR Engineering Solutions Pvt Ltd/ M/s Vardhaman Airports Solutions and any other agency approved by E-in-C’s Branch/ Air Field having experience of execution of three similar works in past and approval obtained from GE/ USERS (ii) Post re-installation of Mafi light, CAMC warranty benefits would be applicable and contractor shall submit an undertaking in this regard. (iii) The contractor in consultation with with specialist agency shall submit a layout plan of conduits with consideration of future expansion and approval obtained from GE/USERS before laying conduits during the resurfacing of runway.
Supply, installation and commissioning of uni-directional high intensity elavated runway edge light fixture on existing transformer housing box with suitable arrangement to receive light fixtures with all required accessories including alignment, levelling, setting of fixture,connection/ inter-connection with isolating transformer. The light fixtures should be suitable for operations on 5 KV, 50 Hz, series circuit 2.8 to 6.6 Amps series circuit to meet ICAO requirement for over run area (RED) complete with breakable coupling, mounting assembly, optical assembly, base plate, gasket, bi-pin lamp holder, connecting lead i/c supply of suitable watt, 6.6 Amps halogen lamp, SS bolts and washers, etc. complete all as specified and as directed. Make : Vardhaman Airport Solutions of model No. VAS REL-1 or equivalent model in AMA/ ATG / ADG SAFE GATE/ HONEYWELL as approved.
Installation, testing and commissioning only for elevated light fixtures for stopway on existing transformer housing box with suitable arrangement to receive light fixtures with all required accessories including alignment, levelling, setting of fixture, connection/ inter-connection with isolating transformer and light fixtures complete all as directed.
Supply and installation for 12" shallow base suitable for dismantled inset runway edge light, threshold inset light and approach inset light along with testing and commissioning inset type high intensity runway edge, threshold and approach light fitting by cutting the PCC manually or with the core cutting machine for 12" shallow base and fixing with suitable compound with side cable entry and all assemblies of the fitting in order as per ICAO norms including making necessary conections with secondary lead, plug and sockets and sealing with rubber/ PVC tape etc. complete all as specified and as directed. Make: ATG of model No. ZM480 or equivalent model in ADB SAFE GATE/ HONEYWELL as approved.
Supply and installation for 8" shallow base suitable for dismantled runway centerline inset lights, touchdown zone (TDZ) inset light and stop bar inset lights alongwith testind and commissioning insert type high intensity runway ceter line touch down zone (TDZ) and stop bar light fitting by cutting the PCC manually or with the core cutting machine for 8" shallow base and fixing with suitable compound with side cable entry and all assemblies of the fitting in order as per ICAO norms including making necessary conections with secondary lead, plug and sockets and sealing with rubber/ PVC tape etc. complete as specified and as directed. Make: ATG of model No.ZM203I or equivalent model in ADB SAFE GATE/ HONEYWELL as approved.
Supply and fix for secondary connectors kit (plug) and making field connections of secondary connector kit (plug) with copper conductor, AFL cables with connector including crimping applying HT tape complete all as specified and as directed. Make: EFLA of model No. KD501.1 or equivalent model in ATG/ ADB SAFE GATE/ HONEYWELL / Vardhaman Airport Solutions as approved .
Supply and fix for secondary connectors kit (recepticle) and making field connections of secondary connector kit (recepticle) with copper conductor, AFL cables with connector including crimping applying HT tape complete all as specified and as directed. Make: EFLA of model No. KD502.1 or equivalent model in ATG/ ADB SAFE GATE/ HONEYWELL/ Vardhaman Airport Solutions as directed.
Supply and fix for 5 KV grade primary connector and making field connections of 5 KV grade primary connector with 5KV grade PVC insulated, PVC sheathed single core, 6.0 sqmm copper conductor, AFL cables with primary connector including crimping applying HT tape complete all as specified and as directed. Make: EFLA of model No. KD510.6 or equivalent model in ATG/ ADB SAFE GATE/ HONEYWELL/ Vardhaman Airports Solutions as approved.
Supply, laying and commissioning for 6.0 sqmm, 1.0 core size 5 KV grade PVC insulated and PVC sheathed, anti-termite and anti-rodent, multistranded copper conductor Air field lighting cable confirming to IS 1554 (Part-II) with up to date amendments complete all as specified and as directed. Make: ANKUR/ RALLISON/ UNIKA/ EUPEN as approved.
Supply, laying and commissioning for 4.0 sqmm, 1.0 core, 600 volt grade AGL secondary cable with multistranded annealed tinned copper conductor, EPR insulated, color coded (Red & Black), laid up and PCP/ TPE Sheathed complete all as specified and as directed. Make: ANKUR/ RALLISON/ UNIKA/EUPEN as approved.
Supply, installation, testing and commissioning for 200 watt, 6.6 Amps, 5000 volt, 50 Hz series isolating transformers encapsulated in polyester resin, finally moulded in neoprene type rubber complete all as specified and as directed. Make: ATG of model No. L-831, ADG Safegate of model No. ITX-L-831-6 or equivalent model in BILDAL ELECTRICALS PRIVATE LTD/Vardhaman Airports Solutions/ HONEYWELL as approved.
Installation, testing and commissioning only for 200 watt, 6.6 Amps, 5000 volt, 50 Hz series isolating transformers encapsulated in polyester resin, finally moulded in neoprene type rubber complete all as specified and as directed.
Supply and installation for C.I isolating transformer housing box, water tight round type, metal container of outside dia 330 mm and maximum height 450 mm made of 10 mm thick cast iron moulding all round, except the top surface, which is 15 mm thick, cast iron moulding suitable to receive a light fitting base plate on the top and underground housing associated with transformer power cable and having a clear hole at two side surface centre 75 mm above bottom surface suitable to receive of 50 mm outer dia, HDPE/ G.I. pipe and check nut as required. The box should have two SS earth bolts of M10 x 30 mm tapped inside near the hole away from the hole centre and having a drain hole at the bottom suitably tapped to receive 15 mm dia, medium grade GI pipe and having clear opening of 220 mm at the top surface and 6 nos. M10 tapped hole at the hole centre 260 mm to receive fitting base plate and bolts and the housing box including a base concrete (1:3:6) type C2 (using 40mm graded broken stone aggregate) of size 630 x 630 x 100 mm thick, all round cement concrete (1:2:4) type B1 (using 40mm graded broken stone aggregate), 150 mm thick, the top sloped with cement concrete (1:2:4) (using 20mm graded broken stone aggregate) along with excavation and returning filling etc. complete all as specified and as directed. Make: Vardhaman Airport Solutions of model No. VAS-CI or equivalent model in Deepak Metal Works/ Kanishak Trading company/ Hare Krishna Industries as approved.
Installation of removed precast transformer housing(TH) boxes with a base cement concrete (1:3:6) type C2 (using 40mm graded broken stone aggregate) of size 630 x 630 x 100 mm thick, all round cement concrete (1:2:4) type B2 (using 40mm graded broken stone aggregate), 150 mm thick, the top sloped with cement concrete (1:2:4) type B1 (using 20mm graded broken stone aggregate) including providing and fixing 300 mm long 15 mm dia medium grade GI pipe with check nut for drainage of water including excavation and returning filling etc. complete all as specified and as directed.
Supply and laying for 4.00 mm dia GI wire earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and as directed.
Material and labour for earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire by means of nut, bolts and washers made out of galvanised iron mild steel and connected to neutral of transformer as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab including 8mm dia TMT bars @ 100mm centre to centre both ways with one handle for lifting made out of 10mm dia MS bar, funnel, wire mesh, 20 mm bore galvanized steel tubing (medium grade) for watering, filling charcoal or coke and salt in alternate layers, 15mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including taking down unserviceable earthing and complete necessary testing all as shown on electrical plate No.2 of SSR Part-I. (Note: GI lead and protection pipe upto 7.5metres shall deem to be included in the quoted rate).
Supply and laying for 50 mm outer dia doubled walled corrugated (DWC) HDPE (high density polyethylene) pipe, ISI marked, confirming IS:14930, Part-II in existing trench/ masonary open duct including coupling, splicing, jointing of pipe etc. complete all as specified and as directed.
Fixing only for 20mm flexible conduit for secondary cable complete all as directed.
Fixing only for 40mm flexible conduit for secondary cable complete all as directed.
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 m in depth for laying cable and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick with soils complete all as specified and as directed.
Removing of excavated material (soil) to distance not exc.50metres and deposited where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed.
Material and labour for dry river sand as in sand cushioning in trenches/ ducts for protection of underground cable (below, above and around the UG cable laid in trenches) of 23 cm spread thickness ( 8 cm in depth before laying the cable and 15 cm in depth after laying the cable) and consolidated (punned) up to 18 cm thickness complete all as specified and as directed. Note : - Thickness after punning shall be measured for payment
Material and labour for sub class 'B', old size bricks for cable protection cover, common burnt clay building bricks, laid dry and flat abutting each other with width equal to length of brick and gap between adjacent bricks not exc.10mm complete all as specified and as directed.
Material and labour for kerf cutting for laying secondary cable in concrete surface using expansion joint, kerf cutting of 10 mm width and 30 mm depth shall be done on PQC surface.The kerfs would be cleaned and filled with sealant as the secondary cables are laid.
Material and labour for kerf cutting for laying secondary cable in concrete surface using expansion joint, kerf cutting of 10 mm width and 30 mm depth shall be done on bitumenous surface.The kerfs would be cleaned and filled with sealant as the secondary cables are laid.
Material and labour for kerf cutting for laying secondary cable in concrete surface using expansion joint, kerf cutting of 10 mm width and 50 mm depth shall be done on PQC surface.The kerfs would be cleaned and filled with sealant as the secondary cables are laid complete all as specified and as directed.
Material and labour for kerf cutting for laying secondary cable in concrete surface using expansion joint, kerf cutting of 10 mm width and 50 mm depth shall be done on bitumenous surface.The kerfs would be cleaned and filled with sealant as the secondary cables are laid complete all as specified and as directed.
Execution of complete DGPS survey of the runway and marking of inset light points to be installed on runway complete all as specified and as directed.
Installation, testing and commissioning only of elevated light fixtures for runway edge light on existing transformer housing box with suitable arrangement to receive light fixtures with all required accessories including alignment, leveling, setting of fixture, connection/inter-connection with isolating transformer and light fixtures complete all as per directed
Installation, testing and commissioning only of elevated light fixtures for turn pad light on existing transformer housing box with suitable arrangement to receive light fixtures with all required accessories including alignment, leveling, setting of fixture, connection/inter-connection with isolating transformer and light fixtures complete all as per directed
Installation, testing and commissioning only of elevated light fixtures for Taxi Way light on existing transformer housing box with suitable arrangement to receive light fixtures with all required accessories including alignment, leveling, setting of fixture, connection/inter-connection with isolating transformer and light fixtures complete all as per directed
Sanidhya Enterprises
AMA Private Limited
satyabhama and co
HAMTECH ENGINEERING PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .