Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹53,180
Closing Date
20 Jun 2024, 12:00 pmClosed
SE EUDC-III GHAZIABAD
SE EUDC-III GANDHI NAGAR GZB
Work of Installation of VCB, Tailless Unit, Fuse Set for HT protection, Control Panel, CT/PT Unit etc.. at various site Under Business Plan Scheme 2024-25 in the Area of EUDD-IV, VII, X, XI and EUTD-III Ghaziabad Under the jurisdiction of EUDC-III, G
2024_PVVNL_924153_1
81/W/2023-24/EUDC-III GZB
Open Tender
Electrical Works
Item Rate
90 days
SE EUDC-III GANDHI NAGAR GZB
Please Refer Tender Documents
2 documents required · 2 mandatory
₹3,540
Superintending Engineer EUDC-III GZB
₹53,180
24 Jun 2024
4 May 2024
20 Jun 2024
4 May 2024
20 Jun 2024
4 May 2024
Amount
Dismantling of 11 KV VCB for O/G CTR 200/100/5A, 350 MVA old & Damaged at various site and Safley carriage from work site to Store center/JE store loading and unloading both side.
Dismantling of 11 KV VCB & Bus Coupler Old & Damaged at various site and Safley carriage from work site to Store center/JE store loading and unloading both side.
Dismantling ofDamaged 33 kv Control Panel at various site and Safley carriage from work site to Store center/JE store loading and unloading both side.
Dismantling of Steel melatable Srap at various site and Safley carriage from work site to Store center/JE store loading and unloading both side.
Dismantling of Damage CT-PT Unit Scrap at various site and Safley carriage from work site to Store center/JE store loading and unloading both side.
Dismantling of Steel Scrap (Control Pannel) and Safley carriage from work site to Store center/JE store loading and unloading both side.
Carriage & Installation/fixing of 11 KV VCB for O/G CTR 200/100/5A, 350 MVA complete in all respect as per RESPO norms. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 11 KV VCB for I/C CTR 200/100/5A, 350 MVA complete in all respect as per RESPO norms. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 11 kv Bus Coupler complete in all respect as per RESPO norms. from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 33 kv Control Panel for Single Transformer complete in all respect as per RESPO norms. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 33 kv Control Panel for double Transformer complete in all respect as per RESPO norms. from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 33 kv VCB with structure 800 A, 750 MVA complete in all respect as per RESPO norms. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 33 kv CT, 200/100/1-1-1 A complete in all respect as per RESPO norms. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 11 KV/110 3 Phase BUS PT,Class 0.5 Burden 100 VA, 50 Hz rated Voltage 11 KV Suitable for STEELMEC Make VCB. complete in all respect as per RESPO norms. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 11 KV/110V 3 Phase BUS PT, Class 0.5 Burden 100 VA, 50 Hz rated voltage 11 KV, suitable for PASCAL Make VCB. complete in all respect as per RESPO norms. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 11 KV Epoxy Resin Cast Indoor Type CT (800/400/5A) Core 1 Class 0.5, Burden15 VA Core 2 Class 5 P 10, Burden 15 VA CT Voltage Rating 11 KV Suitable complete in all respect as per RESPO norms. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 11 KV Epoxy Resin Cast Indoor Type CT (600/300/5A) Core 1 Class 0.5, Burden15 VA Core 2 Class 5 P 10, Burden 15 VA CT Voltage Rating 11 KV Suitable complete in all respect as per RESPO norms. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 11 KV Epoxy Resin Cast Indoor Type CT (400/200/5A) Core 1 Class 0.5, Burden15 VA Core 2 Class 5 P 10, Burden 15 VA CT Voltage Rating 11 KV Suitable complete in all respect as per RESPO norms. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 11 KV Epoxy Resin Cast Indoor Type CT (300/150/5A) Core 1 Class 0.5, Burden15 VA Core 2 Class 5 P 10, Burden 15 VA CT Voltage Rating 11 KV Suitable complete in all respect as per RESPO norms. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 33 kv outdoor CT (400-200-1) complete in all respect as per RESPO norms. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 11 kv Outdoor CT/PT unit 10/5 complete in all respect as per RESPO norms. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 11 kv Outdoor CT/PT unit 15/5 complete in all respect as per RESPO norms. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 11 kv Outdoor CT/PT unit 20/5 complete in all respect as per RESPO norms. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage & Installation/fixing of 11 kv Outdoor CT/PT unit 25/5 complete in all respect as per RESPO norms. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of line material as:- MS Angle- 50 Kg, 11 KV D/O Fuse Set- 440 Nos, MS Channel 100x50x2240 mm- 44 Nos, MS Channel 125x65 mm- 5160 Kg, MS Channel 100x50 mm- 264 Kg, Battery charger- 10 Nos, Battery bank- 10 Nos, Three phase Relay testing kit- 1 Nos, LT Three phase meter Accuchek(0.2s class)-1 Nos, MRI CORD- 1000 Nos from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Fixing of MS Angle at various site complete in all respect as per RESPO norms.
Fixing of 11 KV D/O Fuse Set at various site complete in all respect as per RESPO norms.
Fixing of MS Channel 100x50x2240 mm at various site complete in all respect as per RESPO norms.
Fixing of MS Channel 125x65 mm at various site complete in all respect as per RESPO norms.
Fixing of MS Channel 100x50 mm at various site complete in all respect as per RESPO norms.
Installation of Battery charger at various site complete in all respect as per RESPO norms.
Installation of Battery bank at various site complete in all respect as per RESPO norms.
Providing and construction of Plinth & Foundation of 33 kv VCB with Material at various site complete in all respect as per RESPO norms.
Supply and fixing of LT Tailles Unit 700 Amp. (Marbale 48x24x1, 12 No. Stud & Copper Strip) at various site complete in all respect as per RESPO norms.
Supply and fixing of Lugs at various site complete in all respect as per RESPO norms.
Supply and fixing of Clamp with Nut & Bolt at various site complete in all respect as per RESPO norms.
Supply and fixing of Bolt Nut & Washer with Clamp at various site complete in all respect as per RESPO norms.
Supply and fixing of Control Cable 4x2.5 Sq.mm at various site complete in all respect as per RESPO norms.
Supply and fixing of Control Cable 2x2.5 Sq.mm at various site complete in all respect as per RESPO norms.
Supply and fixing of OC/EF MAIN RELAY (Make-Ashida) at various site complete in all respect as per RESPO norms.
m/s panwar contaruction co. shamli
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .