Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
29 Jun 2026, 6:00 pm5d left
Similar tender results from the same govt authority in the past 3 years.
GE (NW) Mankhurd
GE (NW) Mankhurd
CERTAIN REPAIRS MAINT OF AC PIPE LINES, INSULATION, DUCTING, CONTROL WALLS AND OTHER CONNECTED AC WORKS AND OTHER MAINT WORKS IN THE AOR OF AGE EM UNDER GE (NW) MANKHURD.
2026_MES_770490_1
8583/E8
Open Tender
Civil Works
270 days
GE (NW) Mankhurd
As per tender document
8 documents required · 8 mandatory
₹500
GE (NW) Mankhurd
₹86,000
Yes
8 Jun 2026
8 Jun 2026
1 Jul 2026
8 Jun 2026
29 Jun 2026
22 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply only compressor oil as per requirement, complete all as specified and directed, Make :Servo, HP, BP, Sheetal N-68, Freezol 36 | 100 | Ltr | - | - |
| 2 | Supply only refrigerant (R-22) gas as per requirement, complete all as specified and directed. Make : MAFRON/FLORON/ REFRON/ FREON NOTE FOR ITEM NOS. 1 TO 2: The quantity of the above items shall only be operated to the extent required for topping-up as specified in the relevant other connected items of BOQ. | 140 | Kg | - | - |
| 3 | Supply and fix in repairs automatic capacity control pilot solenoid valve suitable for the liquid line of AC Plants of various capacity complete all as specified and directed, Make :- Rotex, Avcon, SPORLAN, DANFOSS. | 10 | Each Job | - | - |
| 4 | M & L for thermal insulation of 150mm bore chiller water piping with 50mm thick fibre glass wool, crown 150 and of density 24 Kg/Cum, the glass wool shall be covered with and including 24 SWG aluminium sheet cladding, complete all as specified and directed, Make: Lloyd's / TWIGA/ FGP Ltd. | 25 | RM | - | - |
| 5 | -Dittio- all as per item No. 04 above but of 80mm bore chiller water piping | 25 | RM | - | - |
| 6 | -Dittio- all as per item No. 04 above but of 50mm bore chiller water piping | 25 | RM | - | - |
| 7 | Pumping down the existing refrigerant from the plant of 75/80 TR capacity, carrying out the leakage testing of plant with the pressure of Nitrogen gas and monitoring for 24hrs to assess leakages, rectification of leakage by brazing & replacement of necessary gaskets wherever required, vacumizing of the plant by vaccum pump and keep-it upto 24 hours for testing and rectification of leakages if any, finally recharging of existing refrigerant gas to the plant and topping up of refrigerant if required to maintain the standard pressure etc complete including testing of the plant for smooth functioning complete all as specified & directed.
Location : Missare Mine, TS Mahul | 3 | Each Job | - | - |
| 8 | Supply and fix in repairs hi wall split units indoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality including taking down old u/s indoor AC unit of capacity 2 Ton electric driven single phase 230 Volt complete all as specified and directed.Make as per sample | 6 | Each | - | - |
| 9 | -ditto- all as per item No 8 above but for 1.5 Ton capacity complete all as specified and directed.Make as per sample | 6 | Each | - | - |
| 10 | Supply and fix in repairs hi wall split units outdoor (Condener unit) of capacity 2 Ton including filling of refrigerant including taking down old u/s outdoor AC unit complete all as specified and directed.Make as per sample | 6 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
8583TENDERPAGES.pdf
Tender Documents • 0.65 MB
BOQ_862843.xls
BOQ • 0.90 MB
Download all tender documents and submit your bid