| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-AOC H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹11.0 L+₹2,993 (0.27%)Rejected-AOC SKALZANGLING AIR PORT ROAD LEH LADAKH 194101 | LEH | LEH | LADAKH | 194101 | L2 | Rejected-AOC Not accepted being L2 | |
| 3 | L3₹13.2 L+₹2.2 L (20.0%)Rejected-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L3 | Rejected-AOC Not accepted being L3 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
14 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PARTAPUR
GE PARTAPUR
MAINT AND REPAIR TO VARIOUS EXTERNAL ELECTRIC SUPPLY ITEMS AT BASE CAMP AND KHALSAR UNDER GE PARTAPUR
2021_MES_451238_1
GE/P-35/2021-22
Open Tender
Civil Works
Works
180 days
GE PARTAPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE PARTAPUR
₹30,000
Yes
10 Jan 2022
14 Jun 2021
16 Jul 2021
30 Jun 2021
14 Jul 2021
30 Jun 2021
60 days
Amount
Taking out un-serviceable/faulty cable/service connection cable of any grade / type / class of any size for repair / replacement from pole / wall / cable duct under ground trench etc for re-use or removal from site of work all as specified and as directed by the Engineer-in-charge (Note- Excavation and earth work shall be measured and paid separately)
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 2 core 10 sqmm all as specified and directed.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 2 core 16 sqmm all as specified and directed.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 4 core 16 sqmm all as specified and directed.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 4 core 25 sqmm all as specified and directed.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 35 sqmm all as specified and directed.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 50 sqmm all as specified and directed.
M&L for Painting steel and iron surfaces, old/new surfaces of steel tublar poles/steel tublar swaged poles of any description, length n. exc 9 mtr above ground level incl angle iron/clamps bracket etc with one coat of silver aluminium paint two coat of synthetic enamel paint upto 1.5 mtr above coping in 30 cm wide strips in alternate black and Yellow colour complete all as directed by Engr-in-charge.
Supply and fixing Aluminium bus bar chamber 3 phase, 200 Amp capacity with 4 nos Al strips not less than 600 mm long, outdoor type including one MCCB of 125 Amps 4 Pole as incommer with locking arangement, grouting in pcc 1:3:6 and connecting with UG XLPE cable with suitable copper thimbles complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x60mm thickness not less than 6mm thick buried directly in ground( earth plate not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 2.5 mtr below the normal ground level connected to galvanized iron wire 4 mm dia by means of nuts bolts, nuts, check nuts and washers of GI steel all as shown in electrc plate Ni 5 connected to earth test point all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe light grade 40mm bore and GI watering pipe 20mm bore medium grade with funnel and wire mesh ,40mm thick pre cast RCC M-15 ( Nominal mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40X40X3mm frame for cover,PCC M-15 ( Nminal mix) pit, excavation and earth work in any type of soil and connected all as specified and as directed by Engineer-in-charge.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x60mm thickness not less than 6mm thick buried directly in ground( earth plate not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 2.5 mtr below the normal ground level connected to galvanized iron earth strip of size 25 x 4 mm thick by means of nuts bolts, nuts, check nuts and washers of GI steel all as shown in electrc plate Ni 5 connected to earth test point all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe light grade 40mm bore and GI watering pipe 20mm bore medium grade with funnel and wire mesh ,40mm thick pre cast RCC M-15 ( Nominal mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40X40X3mm frame for cover,PCC M-15 ( Nminal mix) pit, excavation and earth work in any type of soil and connected all as specified and as directed by Engineer-in-charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cable, fixing of stay etc 10 Sqm on plan and n exc 1.5 in depth and getting out in hard/dence soil complete all as specified and directed by Engineer-in-Charge.
Returing, filling in incl spreading, levelling watering and well remming in layers n.exc 25cm width, Complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above starting point Completed all as specified and diercted by Engineer-in-Charge.
Sand cushioning for under ground cable 8 cm before laying the cable and 15 cm after laying and streching the cable complete all as specified and directed by Engineer-in-Charge.
M&L Un-reinforced precast factory made concreate cable covers, class LV type-I, with flat size 250x150x40 mm Complete all as specified and directed by Engineer-in-Charge.
Supply and laying/fixing in replacement, GI pipe medium grade 40 mm bore (dia)including all type fittings fixed on walls/to poles with clamps /laid in trenches as cable protection all as specified and directed.
Supply and laying/fixing in replacement, GI pipe medium grade 50 mm bore (dia)including all type fittings fixed on walls/to poles with clamps /laid in trenches as cable protection all as specified and directed.
Supply and laying/fixing in replacement, GI pipe medium grade 80 mm bore (dia)including all type fittings fixed on walls/to poles with clamps /laid in trenches as cable protection all as specified and directed.
S&F MCCB 3 Pole, 415 V, 63 Amps with breaking capacity 16 KA, adjustable type complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 100 Amps with breaking capacity 25 KA, adjustable type complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 125 Amps with breaking capacity 16 KA, adjustable type complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 160 Amps with breaking capacity 36 KA, adjustable type complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 200 Amps with breaking capacity 36 KA, adjustable type complete all as specified and directed by Engr-in-Charge.
Supply,laying ,testing cable or unarmoured electric cable (service wire) in replacement of size 10 sqmm 2 core complete complete all as specified and directed.
Supply and installation erection commissioning and testing of main LT pannel cubical out door type weather/dust proof, factory made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including four pole aluminium bus bar 400 Amps capacity including control wiring with suitable size of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:-
MS Sheet body of LT Panel With double door angle iron frame
Incomming
(a) MCCB, 250Amps, 36 KA Optium 1.0 (Fixed TM range) 4 pole Make : INDOASIAN Cat No 830116-01 Nos
Outgoing
(b) MCCB, 63 Amps, 25 KA, Optium 1.0 (Fixed TM range) 4 pole Make : INDOASIAN Cat No 830050-01 Nos
(b) MCCB, 63 Amps, 25 KA, Optium 1.0 (Fixed TM range) 4 pole Make : INDOASIAN Cat No 830050-01 Nos
(d) MCCB, 25 Amps, 16 KA, Optium 1.0 (Fixed TM range) 4 pole Make : INDOASIAN Cat No 830016-01 Nos
(e) MCCB, 16 Amps, 10 KA, Optium 1.0 (Fixed TM range) 4 pole Make : INDOASIAN Cat No 830710-01 Nos
(f) LED type phase indicattor lamp (R Y B) - 01 Set
(i) Change over 200 Amps Make : INDOASIAN Cat No IN10A200-01 Nos
S&F cast iron cable route indicator in round shape duly marked/engraved "CABLE HT 11KV/Cable LT 101KV fixed on RCC block of size 250mm x 250mm x 250mm all as directed by Engineer in Charge.
Supply and fixing ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 800 Amps all as specified and directed.
Re-stringing, restretching ACSR conductor of overhead HT/LT line on steel poles after removing binding from insulator and rebinding the conductor with insulator including providing new binding wire jumpering providing with sleeves of appropriate size, ACSR conductor with colour code sleeves after restraining and removing unavoidable sags in the lines, complete all as specified and directed by Engr-in-charge.
M&L for Aluminium conductor steel reinforced (ACSR) in replacement as in over head conductor including provision of aluminium tapes for binding all as specified and directed by Engr-in-Charge. Note : (i) weight of ACSR conductors shall be determined by measuring the horizontal distance between center of two adjacent poles and compounding the weight of conductors of size and length provided and 3% extra added for sag, jointing, jumpers etc. (ii) The weight of the aluminium tapes shall not be added in the weight of the conductors for payment purpose. (iii) Size of ACSR conductor will be decided by GE/Engr-in-Charge as per electric load and site requirement.
Supply and fix in replacement Pin type insulator, porcelain, vitrous, white brown or green insulator incl one galvanized mild steel spindle, two galvanised iron washer and one galvanized iron nut of size 100mm height and 65mm dia for 1100 Volts complete all as specified and directed by the Engr-in-charge.
Supply and fix in replacement Pin type insulator, porcelain, vitrous, white brown or green insulator incl one galvanized mild steel spindle, two galvanised iron washer and one galvanized iron nut of size 50mm height and 65mm dia for 1100 Volts complete all as specified and directed by the Engr-in-charge.
M&L for Stay Assembly complete with Accessories as shown in electrical plate No 1 for 16mm dia of stay rod, 180 cm long complete all as specified and directed by Engineer-in-Charge. Note : Earth work shall be measured and paid for seperately.
M&L for loop type insulator, vitreous porcelain white, brown or green large size (65 x 90mm), clearance of hole 16mm complete all as specified and directed by Engr-in-Charge.
S&F in replacement Cross arm bracing, supports clamps and back plated fabricated from structral steel section including nuts, bolts ,washers, welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-Charge.
M&L for galvanised stay strand of size 7/4mm complete all as specified and directed by Engr-in-Charge.
S & F of gaurding wire ,cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia
M&L for line separators of LT OH lines with nut, bolts & washers straight type fixed at a point as directed and suitable for 4 wire complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete in foundation, filling and mass concrete type B1 1:2:4 using 20mm graded stone aggregate for LT panel board/poles foundation.
Supply and erecting and fixing in proper position steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.00metres long) Make: Advance steel tube, National tubing co, Mahindra industries, sohan lal and sons,Sidhartha all as specified and as directed. Note: (i) Excavation ,earth work and PCC shall be measured and paid separately. (ii) Painting will be measured and paid seperately under relevent item.
Material & Labour for PCC (1:3:6) type C-2 using 40 mm graded aggregate as in foundation of pole/stay and filling of mass concrete including providing necessary form work complete all as specified and as directed by the Engineer-in-charge
Material & Labour for PCC (1:2:4) type B-1 using 20 mm graded aggregate as in coping of pole including providing necessary form work complete all as specified and as directed by the Engineer-in-charge
PADMA ENTERPRISES
national engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .