Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹34.0 L+₹2.0 L (6.37%)Rejected-AOC 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L2 | Rejected-AOC NOT ACCEPTED | |
| 3 | L3₹37.6 L+₹5.7 L (17.7%)Rejected-AOC NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC NOT ACCEPTED | |
| 4 | L4₹42.3 L+₹10.3 L (32.3%)Rejected-AOC | L4 | Rejected-AOC NOT ACCEPTED |
Tender Value
Refer Docs
EMD Value
₹68,980
Closing Date
23 Jan 2021, 6:00 pmClosed
GE (SOUTH) UDHAMPUR
GE (SOUTH) UDHAMPUR C/O 56 APO
PROVN OF RETAINING WALL NEAR BLDG NO NP-33 AT 9 PARA (SF) PROVN OF SOLAR WATER HEATER PLANT WITH ALLIED ANCILLARIES FOR NORTHERN COMD PRO UNIT AND CERTAIN REVENUE WORKS AND MINOR WORKSUNDER GE (SOUTH) UDHAMPUR
2020_MES_407158_1
GE/S(U)-57/2020-21
Open Tender
Civil Works
Item Rate
240 days
AOR OF GE (SOUTH) UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (SOUTH) UDHAMPUR
₹68,980
Yes
10 May 2021
26 Dec 2020
25 Jan 2021
26 Dec 2020
23 Jan 2021
9 Jan 2021
26 Dec 2020 - 6 Jan 2021
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation & not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.
PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Brick work with sub-class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
Brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
Returning, filling including spreading leveling watering and well ramming in layers not exceeding 25 mm in any type of soil complete all as specified and directed.
Removing excavated material (soils) exceeding 250 m but not exceeding 500 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs etc complete all as specified and directed by Engr-in-Charge.
Providing M-25 design mix (using 20 mm graded aggregate) as in beams, cantilever, lintels over 1.5 m complete all as specified and directed.
Providing M-25 design mix (using 20 mm graded aggregate) as in slabs supported on walls, beams and columns in floor, roof, landing, balcknies, conopies, decks, slab and in shelves and like complete all as specified and directed.
Form work to soffits of suspended flat slabs such as roof slabs, landings and similar work, not exceeding 200 mm thick (Horizontal or sloping) complete all as specified and directed.
Form work to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/PCC bands in wall, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide complete all as specified and directed.
TMT bars 10 mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per ser item No 13 above but 5 mm dia and over including 10 mm dia in stirrups, spaces and binders etc. complete all as specified and directed.
10 mm thick rendering on fair faces of brick/ concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and directed.
15 mm thick rendering in two layers (10 mm + 5 mm) on fair faces of brick/concrete or stone surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete with water proofing compound complete all as specified and directed. (WPC shall be measured separtely).
Supply only liquid water proofing compound complete all as specified and directed.
05 mm thick CM 1:3 rendering on fair surfaces of ceiling work and finished even and smooth without using extra cement complete all as specified and directed.
10 mm thick rendering as backing coat to receive the tiles on fair faces of brick /concrete surfaces in cement mortar 1:3 and finished even and rough complete all as specified and directed.
Preparation of new plastered surfaces on walls and applying three coats of white wash complete all as specified and directed.
Preparation of new plastered surfaces on ceiling and applying three coats of white wash complete all as specified and directed.
Preparation of new plastered surfaces on walls and applying two coats of cement based paint complete all as specified and directed.
Shingle filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and blinded with earth and rammed including watering complete all as specified and directed.
75 mm thick cement concrete (1:4:8) type D-2 as sub base to floor complete all as specified and directed.
25 mm thick cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregates) as in floor and finished even and fair complete all as specified and directed.
10 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes complete all as specified complete all as specified and directed.
Non-skid coloured ceramic tiles (square/ rectangular) 7 to 8 mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and directed.
50 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 sqm each) area with 6 mm wide joints and 10 mm wide joints between the walls and plinth protection, finished even and smooth without using extra cement, outward slope of not less than 1:12, the joints shall be filled with mastic filling comprising one coat of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
Mild steel ventilators (Box type) factory made with top hung shutters and bottom fixed type shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all as specified and directed. Note : (i) The window shall be fabricated as per Drg CEUZ/TD/1269/2008 Sh 1/3 (ii) Glazing, wire gauge shall be measured and paid separately.
Framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work confirming to Fe 290 Gde-E-165 quality A including one shop coat of zinc chromate primer paint including preparation of surfaces at contractor's workshop before fabrication complete all as specified and directed.
4 mm thick glass sheet of ordinary quality not exceeding 0.5 Sqm in each pane complete all as specified and directed.
Preparation of newly steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube and fixed in opening as per specification and drawing complete all as specified and directed.
Factory made solid panel PVC Moulded door shutter 28 to 30 mm thick stiles with 2, 4 or 6 raised panel design with 2 mm thick Moulded PVC sheet on the front face and 2 mm thick plain coloure PVC sheet on back face complete all as specification and drawing complete all as specified and directed.
Aluminum handles cast type, anodised, 150 mm size complete all as specified and directed.
Aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt complete all as specified and directed.
Mild steel cold rolled butt hinges medium weight 100 mm long complete all as specified and directed.
10 mm thick rendering in CM 1:3 on roof sufaces, finished even and smooth without using extra cement complete all as specified and directed. Note :- Supply only water proofing compound shall be measured and paid seperately under the respective item.
Steel water tubing of nominal bore dia 15 mm medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and directed.
Steel water tubing of nominal bore dia 20 mm medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and directed.
20 mm dia, ball brass, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
500 ltrs capacity rotational moulded polythylene water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed in SSR Part I.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including cast iron P trap, bore of pipe 100 mm and provision of concrete bedding complete all as specified and directed.
10 litres Vitreous China valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
Supply only flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified and directed.
PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
Angle valve, cast copper alloy fancy type screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore complete all as specified and directed.
Stop valve (concealed type), cast copper alloy fancy type, chromium plated with long shank and cup screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore complete all as specified and directed.
15 mm dia bib tap fancy type chomium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
Vitreous China wash basin (Pedestal), white, flat back, size 550 mm x 400 mm excluding tap, chain, plug and porcelain stopper but including brackets and cutting for and pinning in ends of brackets complete all as specified and directed.
Pillar taps 15 mm bore fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' and cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
Brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and directed.
Chromium plated soap dish and fixed with CP brass screws in wooden/plastic cleat complete all as specified and directed.
100 mm dia cast iron sanitary connection pipe upto 300 mm length complete all as specified and directed.
Cast iron soil, waste and vent pipes (sand cast) 100 mm bore in any length with or without ears with cement joints laid in trenches or in floor complete all as specified and directed.
Cast iron soil, waste and vent pipes (sand cast) 75 mm bore in any length with or without ears with cement joints laid in trenches or in floor complete all as specified and directed.
Cast iron soil, waste and vent pipes (sand cast) 75 mm bore in any length with or without ears with cement joints fixed to wall complete all as specified and directed.
Cast iron bend (any radius) diminishing pieces or tapers 100 mm bore fitted with oval access door complete all as specified and directed.
Cast iron bend (any radius) diminishing pieces or tapers 75 mm bore fitted with oval access door complete all as specified and directed.
75 mm bore Cast iron cowls complete all as specified and directed.
Cast iron floor trap 75 mm, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
Stack clamps made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore complete all as specified and directed.
Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe), bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
Vitreous china urinal partition white of size 310 x 700 mm about 40 cm above floor line complete all as specified and directed.
Stainless steel wall mounted cloth hanger with 6 peg set as approved and complete all as specified and directed by Engr-in-Charge.
Shower roses 15 mm chromium plated with or without swivel joints, any size, including 125 mm long arm and fixing to steel pipe or union complete all as specified and directed.
Brick work with sub-class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.
15 mm thick rendering on fair faces of brick work or concrete surfaces in cement motor 1:4 and finished even and smooth without using extra cement complete all as specified and directed.
Cement concrete 1:3:6 type C-1 (using 20 mm graded aggregate) as in surface channels and drains including necessary formwork etc. complete all as specified and directed.
Extra for forming fair finished drain or channel 30/45 cm inner girth in cement concrete, using extra cement, including forms moulds, mitered /stopped ends etc. complete all as specified and as directed.
150 mm bore Sail-glazed stone ware drain pipes laid in trenches and jointed complete all as specified and directed.
Cement concrete 1:4:8 type D-2 (using 40 mm graded aggregate) in bed to 150 mm dia pipes including packing under and haunching against the sides of pipes after they are laid and tested for complete all as specified and directed.
Providing precast cement concrete 1:2:4 type B-1 (using 20 mm graded aggregate) as in manholes cover slab etc. complete all as specified and directed by Engr-in-Charge.
Providing cement concrete 1:2:4 type B-0 in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones, bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles complete all as specified and directed.
Mild steel TMT bars 6 mm to 8 mm dia cut to length bent to shape required including cranking bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed.
Providing M-25 design mix (using 20 mm graded aggregate) as in beams, cantilever, lintels over 1.5 m complete all as specified and directed.
Providing M-25 design mix (using 20 mm graded aggregate) as in slabs supported on walls, beams and columns in floor, roof, landing, balcknies, conopies, decks, slab and in shelves and like complete all as specified and directed.
Providing Reinforced Cement Concrete M-25 design Mix (using 20 mm graded aggregate) as in foundation including rafts, footings, foundation beams, plinth beams, bases of columns etc. complete all as specified and directed.
Providing Reinforced Cement Concrete M-25 design Mix (using 20 mm graded aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed.
Use and waste formwork to sides of concrete foundation footings base of coloumns sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished flat surface of concrete complete all as specified and directed.
Use and waste formwork to sides of columns, pillars, posts, struts, piers and stanchions, rectangular or square for rough finished flat surfaces of concrete complete all as specified and directed.
Hard core of broken stones or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick including watering and rolled to true surface complete all as specified and directed.
EWC of size 380 mm x 660 mm x 765 mm Bowl for Coupled WC with UF soft close seat cover, hingle, fixing accessories set and accessories set including S Trap-250 mm complete all as specified and directed. Make : Jaquar Cat Part No LYS-WHT-38751S including flushing cistern with cistren fittings Make : Jaquar : LYS-WHT-38201
Health faucet with 8 mm Dia 1.2 Metre long Flexible Tube & Wall Hook complete all accessories complete all as specified and directed. Make : Jaquar, Cat Part No : ALD-573
Toilet roll holder with flap complete all as specified and directed. Make : Jaquar, Cat Part No : ACN-1153N
Towel rack 600 mm long with lower hangers but with 3 hooks complete all as specified and directed. Make : Jaquar, Cat Part No : ACN- 1181FHN
Soap dish complete all as specified and directed. Make : Jaquar, Cat Part No : AQN -7731
Overhead shower 150 x 150 mm Squarel Shape Single flow (ABS Body Chrome Plated with Grey Face Plate) with Rubit Cleaning System including shower arm complete all as specified and directed. Make : Jaquar, Cat Part No : OHS-35495
Single Lever Extended Basin Mixer (Height -95 mm) with Popup Waste System with 450 mm Long Braided Hoses complete all as specified and directed. Make : Jaquar, Cat Part No : FON-40052B including necessary fittings.
Bib cock with wall Flange bore of pipe 15 mm complete all as specified and directed. Make : Jaquar, Cat Part No : OPP-15037M
Angular stop cock with wall flange bore of pipe 15 mm complete all as specified and directed. Make : Jaquar, Cat Part No : OPP-15053PM
Concealed stop cock with wall flange bore of pipe 15 mm complete all as specified and directed. Make : Jaquar, Cat Part No : OPP-15083KPM
Corner Glass Shelf (with Bracket) complete all as specified and directed. Make : Jaquar, Cat Part No : ACN-1173
Towel rail 300 mm Long for wash basin area complete all as specified and directed. Make : Jaquar, Cat Part No : ACN- 1101N
Mirror cabinet with PVC body and openable shutter, shelves and size 350 mm x 450 mm complete all as specified and directed. Make : ARCO or JINDAL
32 mm dia PVC waste pipe complete all as specified and directed.
Rough excavation not exceeding 1.5 m deep and getting out out in hard/dense soil complete all as specified and directed.
Rough excavation not exceeding 1.5 m deep and getting out out in hard rock complete all as specified and directed.
Excavating over areas, not exceeding 1.5 m deep and getting out in hard/dense soil complete all as specified and directed.
Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
Extra over stone walling for hammer dressing with miximum depression on face from straight edge held against the dressed surface not exceeding 40 mm to face stones (Lime or sand stone) and dressing of face beds and joints, as specified of ranom rubble walling, uncoursed or brought upto courses complete all as specified and directed.
Precast cement concrete Block (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) as in bond stones set in cement mortar 1:6 complete all as specified and directed.
Raised pointing to random or polygonal rubble, uncoursed or brought upto courses stone masonry in cement mortar 1:4 complete all as specified and directed.
PVC 110 mm dia pipe in any length with rubber rings joints laid as in weep holes complete all as specified and directed.
Hand packing (any thickness) at back of wall over arches etc. and rising (or lowering) to the required labour complete all as specified and directed.
Use and waste formwork to sides and soffits of floor or roof beams, beam hunching, girders, lintels, cantlievers, shelves including supports etc. for rough finished flat surfaces of concrete complete all as specified and directed.
Roughening surfaces of old concrete surfaces by picking sweeping, cleaning and washing down with water to remove dust etc. including taking down tarfelt and brushing neat cement slurry @ 3 Kg/Sqm including 15 mm thick plastering in CM (1:4) finished even and smooth mixed with water proofing compound complete all as specified and directed. (WPC shall be measured and paid separately)
Applying a coat of bituminous primer conforming to IS-3384 @ 3.5 Kg/Sqm on prepared surface of plaster. After drying of primer, apply a coat of hot blown 85/25 grade bitumen confirming to IS-702 @1.2 Kg/Sqm of plastered surface and provide polymeric water proofing membrane laid with overlaps bonded with hot blown bitumen, ends overlaps shall not be less than 150 mm and side lap 75 mm. Minimum weight of water proofing membrane shall be 3.5 kg per Sqm. (Make - STP/IWL). Over the polymeric water profing membrane, apply semi hot blown 85/25 grade condition @ 0.50 Kg/Sqm dusted over the bitumen coat complete all as specified and directed.
Digital vitrified ceramic tiles 10 mm thick (square/rectangular) polished area of each tiles not exceeding 0.36 sqm in floors etc. and jointed in neat cement slurry and pointed in white or coloured cement to match the work using dark shade complete all as specified and directed.
Glazed coloured ceramic tiles in dado/vertical surface (300 mm x 600 mm x 7 mm) thick set and jointed in neat cement slurry and pointed in coloured cement to match the surface complete all as specified and directed.
Screed bed or bedding layer of mortar 15 mm thick in CM (1:4) for laying floor tiles complete all as specified and directed.
10 mm thick cement plaster in CM (1:3)on brick wall for laying wall tiles complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
PCC 1:2:4 type B-1 (using 20 mm graded aggregate) in surafce channel and drains complete all as specified and directed.
20 mm thick rendering on fair faces of brick work or concrete surfaces in cement motor 1:4 and finished even and finished even and smooth without using extra cement complete all as specified and directed.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks and similar work confirming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
Mild steel, 1.25 mm thick plain, black sheet inbut in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc. with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets etc. as required complete all as specified and directed.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering. Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe-290 (Gde E-165) complete all as specified and directed.
Rolled mild structural steel plates (Plain or Chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to 410-W (Gde E-250) quality-A complete all as specified and directed.
Mild steel cold rolled butt hinges medium weight 50 mm long complete all as specified and directed.
Flush pointing to brick work in cement mortar 1:4 complete all as specified and directed.
Flush pointing to brick laid flat or brick tiles in pavings work in cement mortar 1:4 complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
50 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in plinth protection finished even and fair without using extra cement complete all as specified and directed.
75 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in in floor and finished even and smooth complete all as specified and directed.
20 mm thick screed bed are bedding layer of cement mortar (1:4) for laying floor finishes complete all as specified and directed.
Chequered cement concrete tiles 30 cm x 30 cm x (22-25) mm thick, machine pressed, factory made, Glossy finished, set jointed and pointed in neat cement slurry in floor with grey cement and pigment complete all as specified and directed.
40 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates) as in floor and finished even and smooth complete all as specified and directed.
Welded steel wire fabric not exceeding 4 kg per sqm, supplied and fixed complete to wood or steel members including one shop coat of zinc chromate primer paint including preparation of surfaces at contractor's workshop before fabrication complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.60 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping complete all as specified and directed.
Point wiring for one light/fan/Exhaust fan controlled by one switch using 1.5 Sqmm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit (thickness not less than 1.5 mm and 20 mm dia), medium grade with Modular metal flush boxes & PVC back plate for mounting modular type in adequate module of switches, sockets & regulators etc. with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sqmm as earth wire stranded and conected to earth dolly complete all as specified and directed. Make : Haveels/ Polycab/Finolex.
All as per ser item No 136 but for 3 pin 5 Amps socket outlet independent including copper PVC insulated PVC unsheathed 1.5 Sqmm earth wire and connected to earth dolly complete all as specified and directed. Make : Haveels/ Polycab/Finolex.
Modular switch 6 Amps single pole one way with outer strip complete all as specified and directed.
Socket combined 2-in-1, 3 Pin 6 Amps (Modular Type) with outer strip complete all as specified and directed.
Ceiling rose surface bakelite 3 terminals complete all as specified and directed. Make : Cona, Cat Part No : 2126/SSK Cat Part No : 572 or equivalent of make in Havells/Anchor/Kolors.
Exhaust fan Ventil Air - DB 300 mm including louver complete all as specified and directed. Make - Havells/Polycab/Bajaj.
New E-Lite LED Curve, high lumen batten with efficacy of 100 lumens in 20 W complete all as specified and directed by Engr-in-Charge. Make - Havells Cat Part No LHEXBXPNIN1W020 or equivalent to Polycab/ HPL/Bajaj.
Replacement of LED bulk head luminaire, 10 W (ENDURA RUGBY) Cat Part No LHEOAOP7UZ6W010 230 Volts wall/surface mounted complete with with LED lamp 10 watt, with all accessories, pre-wired, including providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.
Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Make : Schneider/ Siemens/Legrand.
Replacement MCB Single Pole, 230 Volt, Raiting 6 to 32 Amps complete all as specified and directed. Make : Schneider/Siemens/Legrand.
Replacement MCB Single Pole and Neutral , 230 Volt, Raiting 35 to 63 Amps complete all as specified and directed. Make : Schneider/ Siemens/Legrand.
Fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sqmm nominal cross section in service connections complete all as specified and directed. Make : Schneider/ Siemens/Legrand.
Earthing complete with galvanised steel earth plate electode 600 mm x 600 mm x 6.00 mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level connected to and including galvanised steel earth lead wire 4 mm dia by means of bolts, nuts, chock, nuts and washers of galvanised iron or steel including PCC Pit in 1:2:4 type B-1 angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20 mm bore with funnel and wire mash and light grade GI protection pipe 15 mm bore upto main board complete all as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected to main control board as specified and testing completion complete all as specified and directed.
Replacement of New E-Lite LED Curve, high lumen batten with efficacy of 100 lumens in 10 W complete all as specified and directed by Engr-in-Charge. Make : Havells Cat Part No : LHEXBXPNIN1W010 or equivalent to Polycab /HPL/Bajaj
Supply Installation Testing and Commissioning of Solar Water Heater System (Flat Plate Collector) (FPC Type) Direct Thermosyphonic type Non Pressurized with 500 Ltrs SS Tank with tank stand, 100 mm Rockwool Insulation and Al. Cladding with 05 nos of collectors, collector Stand copper couples, end caps, Box type collector with Screwless Technology Including Transportation and Installation of Solar water Heater with 3KW heating element = 02 Nos complete all as specified and directed. Make : Recold Omega/SOLOCHROME/TATA BP SOLAR. (a) Solar Collector should be box type structure for high strength and stability. (b) The collectors should have the Brass Couplings and end caps for Rustproof and long life screw. (c) The collectors must have a screw less construction for water proof and high stability. (d) Solar hot water tank of capacity 500 Ltrs. Of SS316L type material
Note for ser item No 151:- (a) The manufacturer will provide free maintenance and servicing of the Solar water heater system for 2 years and the cost of the same will be included in Quoted rates by the contractor and further AMC on agreed mutual terms and conditions. (b) General maintenance program and training will be conducted to the MES staff and user by the manufacturer and cost of the same will be included in the quoted rates. (c) The collectors warranty should be 7 years.
Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed in SSR Part-I of capacity 1000 Ltrs.
Supply and fix GI tubing medium grade of 15 mm bore complete all as specified and directed.
Supply and fix GI tubing medium grade of 20 mm bore complete all as specified and directed.
Supply and fix GI tubing medium grade of 25 mm bore complete all as specified and directed.
Lagging of pipes used in water supply or plumbing all round with 25 mm thick bonded mineral wool pre-formed SNAP ON pipe section of density 144 kg/cum confirming to IS 9842 on 20 mm dia pipe of internal dia complete all as specified and directed.
Lagging of pipes used in water supply or plumbing all round with 25 mm thick bonded mineral wool pre-formed SNAP ON pipe section of density 144 kg/cum confirming to IS 9842 on 15 mm dia pipe of internal dia complete all as specified and directed.
25 mm bore pipe gun metal gate valve with iron wheel head screwed both ends for iron pipes complete all as specified and directed.
Mild steel framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted or gorged into spikes, framed guard bar, baned iron doors, ladder framed balusters, railing frame work for water tanks, cooler stand etc. and similar work confirming to 1 L 290-0 or Gde-I 165 complete all as specified and directed. Note : The rate quoted shall deem to including the rate for fixing/grouting of MS Frame on the roof/floor as directed by Engr-in-Charge.
Sub main wiring with proper colour coding, insulated, multistranded, copper conductor PVC FRLS cable of 2 run 6 sqmm for phase and neutral and one run of FRLS 4.0 sqmm for earth wire unsheathed, multistranded, copper conductor, PVC cable complete all as specified and directed. Make : Havells/Polycab/Finolex.
Replacement sheet metal enclosure MCB distribution board Single pole & neutral 240 volts 2 way with single door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good disturbed wall surfaces complete all as specified and directed. Make - Havells/Legrand/Schneider/Siemens.
Replacement MCB Single Pole and Neutral , 230 Volt, Rating 40 Amps complete all as specified and directed. Make: Havells/Legrand/ Schneider/Siemens.
Cutting existing GI pipe of any size for taking new connection including all fittings, joints etc. complete all as specified and directed.
PCC 1:2:4 type B-1 (using 20 mm graded aggregate) for cement concrete in foundations, filling and mass concrete complete all as specified and directed.
Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule for 25 mm bore of pipe and fixed complete all as specified and directed.
Air Terminations Single pointed aluminium rod 12 mm dia and 300 mm long with necessary fixing arrangements on roof complete all as specified and directed by Engr-in-Charge.
Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm hexogonal head screw complete all as specified and directed by Engr-in-Charge.
Rectangular PVC insulators for copper/ aluminium/GI Strip complete all as specified and directed by Engr-in-Charge.
Aluminium Strip 25 x 3.15 mm and fixing screws from aluminium air termination rod to test point terminal as down conductor and roof conductor complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below the normal ground level) connected to galvanised iron strip 25 x 4 mm as earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 including Charcoal Dust, Commen salt, 20 mm bore GI medium grade watering pipe, 40 mm dia GI light grade protection pipe with funel and wire mesh, PCC pit in 1:2:4 type B-1 (using 20 mm graded stone aggregate) with angle iron 40c40c5mm frame, RCC pit cover of suitable size complete all as specified and directed by Engr-in-Charge and testing for required value complete. Note :- (i) Item include the cost of earth lead and GI protection pipe upto 7.5 mtr length. (ii) On completion of Earthing Contractor should check Earthing Results and submit the Test Report to Engr-in-charge. If desired results are not obtained then Earthing shall be redone by the contractor at his own cost.
R K BUILDERS
SINGH CONST CO
RAJ MOHD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .