| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.2 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹31.7 L+₹1.4 L (4.55%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹32.4 L+₹2.0 L (6.75%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹32.5 L+₹2.2 L (7.10%)Rejected-Finance 25 25 SADAR BAZAR JALANDHAR CANTT | JALANDHAR | JALANDHAR | PUNJAB | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹33.6 L+₹3.3 L (10.9%)Rejected-Finance H NO 21666 POWER HOUSE ROAD STREET NO 9 BATHINDA PB 151001 | BATHINDA | PUNJAB | 151001 | L5 | Rejected-Finance Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹94,620
Closing Date
30 Mar 2021, 6:00 pmClosed
GARRISON ENGINEER EAST JALANDHAR CANTT
GARRISON ENGINEER EAST JALANDHAR CANTT
MANNING AND OPERATION OF VARIOUS E/M INSTALLATIONS INCLUDING MINOR REPAIRS IN J-1 LOCATION UNDER GE (EAST) JALANDHAR CANTT
2021_MES_421565_1
GE/JULL/ET-67/2020-21
Open Tender
Civil Works
Item Rate
330 days
JALANDHAR CANTT
As per tender Document
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER EAST JALANDHAR CANTT
₹94,620
Yes
28 May 2021
23 Feb 2021
1 Apr 2021
23 Feb 2021
30 Mar 2021
10 Mar 2021
Amount
Attending of electrical complaints at Main power house such as tripping of main/ distribution feeders, low/ high voltage, fluctuation of voltage, no light and not working of security lights any type including high mast from panel/ pole/ transformer and any other sort of complaint in distribution system, cables etc of main 11 KV HT/ 0.433 KV LT distribution system, at J-1 power house round the clock and rectification of fault, after visual check to HT/ LT cables and HT/ LT panels, by repairing tightening of joints, replacement of burnt/ overheated joints/ thimbles/ leads etc and restoration of electric supply in minimum time including day to day maintenance, tightening of all nuts, bolts in VCBs, LT panels, transformers, cleaning of all electric joints, checking of all earth connections, re-tighting, cleaning and maintenance of all earth pits, maintaining of necessary documents such as log sheets, attendance register as per standard format and routine cleanness of installations by cutting of grass/ shrubs/ cleaning of debris complete all as directed comprising with the following: - (a) HT VCBs - 12 Nos (ESS-I, II) (b) Distribution transformers step down 11 KV/ 0.433 KV of capacity 400 KVA to 630 KVA - 05 Nos (c) LT Panels/ Feeder Pillars/ APFC Panels
Operation & maintenance of HT panels 11 KV including maintaining of record of tripping, load state etc round the clock (03 shifts per day) by deploying one electrician having ITI qualification with minimum 2 years experience or minimum 5 years experience in respective trade and one helper to assist the services having minimum 2 years experience in respective trade, (including electricians will be provided with mobile phone without camera) including necessary T&P and comprising of following equipments complete all as specified and directed :- (a) HT VCBs - 12 Nos (ESS-I, II) (b) Distribution transformers step down 11 KV/ 0.433 KV of capacity 400 KVA to 630 KVA - 05 Nos (c) LT Panels/ Feeder Pillars/ APFC Panels
Attending of complaints of refrigeration, AC such as not working of Split AC water cooler, refrigerators and deep freezers etc., required to make the item functional round the clock by deploying skilled suitable tradesman including necessary T&P complete all as specified and directed.
Manning & Operation of Sewage Treatment Plant installed and maintain all the parameters as per CPCB norms by adding all the chemicals/ chlorine liquid as required by employing One No. of Operator (ITI –Electrical / Fitter) having ITI qualification with minimum 2 yrs experience or matriculate with minimum 2 years experience in respective trade and two helper to assist the services in 02 shifts per day (each shift of 08 Hrs), maintain cleanliness of the complete installations by cutting of grass/ shrubs/ cleaning of debris, repair/ replacement of minor parts consisting of following :- (a) Air Blower motor 20 HP - 02 Nos (b) Sludge pump motors 2 HP - 02 Nos (c) Filter feed pump 5 Hp - 02 Nos (d) Submersible sewage motor 2 HP - 02 Nos (e) Garden w/s motor 10 HP - 02 Nos (f) Press for dry sludge 1.5 Hp - 01 No (g) Feed sludge motor from press 1.5 Hp - 02 Nos (h) DG Set 125 KVA - 01 No. (j) Testing of treated water from approved lab of Punjab Pollution Control Board to check all parameters of treated water per month
Manning & Operation of water supply installation including operation of valves and back washing of pressure filters and firefighting Equipments as and when required, routine cleanness of installations by cutting grass/ shrubs/ cleaning of debris by deploying one operator (Electrician/Fitter) having ITI qualification with minium 2 years experience in respective trade in each shift of 8 hrs round the clock (03 shifts per day), consisting with following :- (a) Raw water lifting pump with motor 20 HP - 04 Nos (b) Clear water pump with motors 10 HP - 03 Nos (c) Agitator motors 0.5 Hp - 02 Nos (d) Chloronome plant - 01 No (e) Water filtration plant - 01 No. (f) DG set 125 KVA - 01 No (g) Fire jockey pump motor 15HP- 01 No. (h) Fire pump electrical operated centrifugal motor pump 75 HP- 01 No. (j) Diesel operated centrifugal pump-75 HP (k) Fire Hydrant-09 No. (l) Electric panel for fire fighting pump- 01 No
Attending complaints of internal electrification received on phone or in person at complaint centre for no light, voltage fluctuations, non working of light fitting, ceiling fans, exhaust fans etc by checking of existing electrical items for continuous electric supply including carrying out minor repairs such as changing of fuse, small pieces of wires etc carrying out repairs such as tightening of loosen electric connections, switches, sockets, switch board, ceiling lights, wall light fittings, ceiling fans, fan regulators, electronic ballast, ceiling rose, MCBs /exhaust fans etc., whichever is required to make the item functional and replacement of any spares shall be measured and paid for separately under respective items.
Note for item No. 1.00 to 6.00 :- (i) Contractor will provide all the tools, plants, transportation as required for maint & operation to workers without extra cost to department (ii) The contractor's rep (Electrician/ water supply operator/ refrigerator mechanic) shall attend all types of electrical/ water supply/ Refrigeration and Air Conditioning complaints as directed. (iii) Contractor will employ electricians/ Refrigerator mechanic/ operators & helpers per shift round the clock during all working days including holidays and Sundays. (iv) The complaints given shall be attended within minimum possible time or maximum upto 24 hours. If complaint not attended by the due time Rs. 500/- shall be deducted per complaint per day till the rectification time. (v) No labour employed including contractor at site shall be allowed to possess mobile without camera inside the area. (vi) The contractor shall maintain necessary documents such as log sheets, attendance register, PRRB and record of tests of STP and water supply installation, tripping record and load state of HT panel or any other record as directed by Engineer-in-Charge or as specified in the particular specifications and stationary shall be provided by the contractor without any extra cost.
(vii) The contractor shall maintain cleanliness of the complete installations by dusting/ cutting of grass/ shrubs/ cleaning of debris and the quoted rates shall be deemed to be included for the same and nothing shall be paid extra. (viii) The contractor shall also provide proper uniform confirming of full trousers, shirt, cap with Name and trade tag to the staff deployed for the work as approved by the Engineer-in-Charge. (ix) Payment record to the electrician, refrigerator mechanic, Operators & helper employed by the contractor for the above work shall be maintained by the contractor, payment should not be less than the minimum wages current rates and record shall be submitted to department duly signed by the staff monthly. (x) Any stores required to attend the complaint and not included in the schedule shall be given by department free for fixing. (xi) Contractor shall be liable to pay penalty as under :- (a) In case of absence from duty for Electrician @ Rs. 700/- per shift and for Helper @ Rs. 500/ per shift. In case of absence from duty, recovery @ of prevailing minimum fair wage shall be done from quoted rate in addition to penalty per shift already mentioned. (b) In case of without uniform for Electrician and Helper Rs. 200/- (Each) per shift.
Attending complaints by deploying labour for repair to leakage/ blockage of water carrying pipes size 25mm to 200mm of any description such as CI/GI/DI, sluice valve at any location including excavation & earth work, cutting existing pipe lines, dewatering etc all as specified. Note : (a) Excavation/ earth work upto 01 meter required will be included in quoted rate (b) Rate quoted shall be deemed inclusive of necessary T&P required. (c) Rectification of defects in any type & size of pipe/ sluice valve etc. including bailing out water if any and all as directed at site (d) Cost of nuts, bolts, washers, gasket of any type and size, cutting of pipe, jointing and other minor parts shall be deemed to be included in quoted rate.
Supply & use in treated sewage water, Calcium hypo-chloride liquid based high strength chlorine granule (60% to 65%) suitable to water disinfection complete all as specified and directed by Engineer-in-Charge. Make : Vikram PAC of M/S Grasim Industries Ltd (Chemical division)/ Renuka Water/ BM AQUA Tech Pvt ltd/ AQUA FIT
Supply only switch modular type, 5 Amps, 240 Volt AC single pole, one way including taking down existing switch complete all as specified.
Supply only switch modular type, 5 Amps, 240 Volt AC single pole, two way including taking down existing switch complete all as specified.
Supply only switch modular flush type, 15 Amps, 240 Volt AC single pole, one way including taking down existing switch complete all as specified.
Supply only socket out let 5 Amp, 5 pin modular types including taking down existing socket complete all as specified.
Supply only Socket outlet multipurpose 3 in 1, 6 pin, 5 & 15 Amps, modular type including taking down existing socket complete all as specified.
Supply only Bell push switch modular type 5 Amps, SP, 240 volts including taking down existing bell complete all as specified.
Supply only Bell electric AC (Ding Dong) 240 volt SP including taking down existing bell complete all as specified.
Supply only Lamp holder insulated body with back plate suitable for batten fittings including taking down existing lamp holder complete all as specified.
Supply only fan step regulator, electronic type, modular type, single phase, 300 watt including connection complete after dismantling/ removing unserviceable regulator all as specified.
Supply only MCB SP 6 Amps to 40 Amps, 240V with rupturing capacity 10 KA including taking down existing MCB complete all as specified.
Supply only MCB SPN 6 to 40 Amps, 240V with rupturing capacity 10 KA including taking down existing MCB complete all as specified.
Supply and fixing in repair aesthetically designed linear mirror light 07 watt with provided with a high output PMMA diffuser for glare free light, dimension : 600mm, including taking old one with all accessories complete all as specified and directed. Make : Crompton cat part No LCL-14-CDL or equivalent in Havells/ Polycab/ HPL
Supply only LED bulb retrofit type 7 watt, B22, lumen output 100, color temp 6500K including taking down existing CFL complete all as specified.
Taking down old unserviceable capacitor clamp and split pin and supply and fix capacitor clamp and split pin all as specified and directed
Supply only for condenser 2.5/ 3.0/4.0 MFD suitable for ceiling/ exhaust fans including taking down existing complete all as specified and directed.
Supply only of flexible cord PVC insulated FRLS type with stranded copper conductor wire of size 23/ 0.0076 Sqmm 3 core including taking down existing cable complete all as specified.
Supply only 20mm dia rigid PVC conduit exclusive of boxes (junction/ terminal) but exclusive of all tees, bends, elbow, reducers, bell mouth tubs, ends and fixing, all accessories such as couplers, lock nuts, saddles, pipe clamps etc, all as specified and directed
Supply only modular 3 module cover plates for fixing modular switches and sockets complete all as specified and directed.
All as per item No. 26.00 but of modular 2 module cover.
All as per item No. 26.00 but of modular 6 module cover.
All as per item No. 26.00 but of modular 1 module cover.
Supply only ultra bright glass LED tubelight fitting 20 watt, 6500 K (Min) for installation existing T-8 tublight with G 13 lamp holder with aluminium heat sink arrangement including taking out old unserviceable tubelight fitting 36 watt complete all as specified and directed.
Supply only Plug top 5/6A 3 Pin Plug 220 Volt all as specified and directed.
Supply only Plug top 15/16A 3 Pin Plug 220 Volt all as specified and directed.
Repair to split type AC by replacing the following items complete all as specified and directed by Engineer-in-Charge: -
Supply and fixing of starting/ running capacitor conforming to IS specifications suitable for 1.5/ 2 TR AC. Make : Havells/ Unistar/ Asian/ EPCOS
Supply & fixing of thermostat switch suitable for 1.5 / 2 TR AC. Make : Danfoss/ Renutrol/ Indfoss
Supply & fixing single pole contactor of rating 30 Amps with magnetic coil 208 - 240 V, AC, 50 Hz suitable for split AC of 1.5 / 2 TR. Make : Schneider Cat Part No. LCIK1210DR or equivalent in L&T/ C&S/ BCH
Supply & fixing in replacement starting / running capacitor suitable for water coolers of capacity 40/80 liters complete all as specified and directed by Engineer-in-Charge. Make : USHA/ Havells/ EPCOS
Supply only wood wool pad for desert cooler set (3 Nos) of any size complete all as specified and directed
Supply & fixing in replacement starting relay for refrigerator of capacity 591 Ltrs complete all as specified and directed by Engineer-in-Charge.
Supply only PVC insulated 1100 volt grade 10 Sqmm multistranded copper wire FRLSH type complete all as specified and directed
Supply only PVC insulated 1100 volt grade 6 Sqmm multistranded copper wire FRLSH type complete all as specified and directed
M/s GURFATEH BUILDERS
AGGARWAL ENGINEERING CO
CHOUDHARY AND SONS
SUNRISE ENGINEERS AND CONTRACTOR
R K ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .