Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.9 LAccepted-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹11.1 L+₹4,474 (0.40%)Rejected-Finance | 2 | Rejected-Finance NOT L1 | |
| 3 | 3₹11.3 L+₹20,051 (1.81%)Rejected-Finance 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | 3 | Rejected-Finance NOT L1 |
Tender Value
₹13.2 L
EMD Value
₹27,000
Closing Date
7 Dec 2021, 6:00 pmClosed
AGE(I) Fatehgarh
AGE(I) Fatehgarh
SPECIAL REPAIR/ REPLACEMENT OF INTERNAL WIRING AT BLDG NO P-311 (RECORDS OFFICE) AT FORT AREA, RAJPUT REGIMENT CENTRE FATEHGARH CANTT
2021_MES_488580_1
AGE(I) /FAT/ET-42 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE (I) Fatehgarh
PLEASE REFER TO TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
AGE (I) Fatehgarh
₹27,000
Yes
24 Dec 2021
16 Nov 2021
9 Dec 2021
16 Nov 2021
7 Dec 2021
24 Nov 2021
16 Nov 2021 - 24 Nov 2021
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power point) complete, including fixture and fittings such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and as directed.
Taking down Aluminium sub main wiring and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed.
M&L for point wiring of One light/fan/bell/exhaust fan point controlled by one switch with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated-unsheathed, drawn in & including concealed PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia & 1.6 mm thick sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc complete all as specified and directed for the following- Note- (i) The quoted rate is deemed to be inluded for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
...ditto as above but for One 5 pin 5 Amp switch socket combination point on an independent board...ditto....
...ditto as above but for one 15 Amp 6 Pin switch socket combination independent with 2.5 Sqmm FRLS unsheathed copper conductor single core multistranded with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable ...ditto....
S&F switch piano flush type 5 Amp single pole one way complete all as specified and as directed.
S&F switch socket combination 2 in 1 flush type 5 Amp 5 Pin complete all as specified and as directed.
S&F switch socket combination 5 in 1, 5/15 Amp flush type complete all as specified and as directed.
S&F ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
Supply and fix electronic fan regulator 120 watts 5 stepped type complete all as specified and directed
M & L lamp holder PVC/Polycarbonate type insulated body with back plate angle type for batten fittings complete all as specified and as directed.
S&F LED lamp of 9W and colour temp 6500K suitable to fix in angle hoder, complete all as specified and directed.
Supply, installation, commissioning and testing including connection of semi concealed type LT indoor factory made CPRI type tested LT Feeder Pillar box 415 Volts, Cable alley, with individual compartment for MCCB/MCB, side hinged front openable doors with screwed knobs, bending of edges of front cover with providing suitable rubber/neoprene gaskets at edges, protection class IP 54 as per IS 8623, IS 5039 / relevant IS/IEC codes of suitable size, dust and vermin proof fabricated out of CRCA Sheet 2 mm thick and frame of angle iron of suitable size duly welded including cable entry & exit through glands including two coats of powder coated paint over a coat of red oxide primer on both outer and inner surfaces of panel of suitable size all as specified and as directed including following items:- BUSBAR : Copper bus bar suitable for 3-Phase for wire system of capacity with 200 Amps for RYB and 100 Amps rating for Neutral. INCOMING : (i) MCCB 4Pole , 125 Amps breaking capacity 16 KA thermal magnetic setting 415 V, 50 Hz (Make : Legrand DPX 160 Cat No : 4200 16 or equivalent to specified make ) - 01 No (ii) Indicator lamp LED type (RED, YELLOW, BLUE) - 01 Set. OUTGOING : (i) MCCB 4Pole, 63 Amps breaking capacity 16 KA thermal and magnetic setting, 415 V, 50 Hz (Make : Legrand DPX 160 Cat No : 4200 13 equivalent to specified make ) - 04 Nos
Supply and fixing in replacement of VTPN DB suitable for Mounting MCCB as Incomer of rating 100 Amp Vertical distribution board 4 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified and directed.. (Make: Legrand Ca No 5077 25 or equivalent to specified make )
Supply and fixing in replacement of MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and directed.
Supply and fixing in replacement of MCB distribution board SPN 240 Volt 4 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and directed.
S & F in repair MCCB 100 Amps , 4 pole, 415 volts , 50 Hz , 16 KA breaking capacity with adjustable thermal magnetic release, with spreader links on both sides complete all as specified and directed.
S&F in replacement metal clad plug & socket with metal plug top enclosure with a two pin and earth plug top and socket suitable for one single pole MCB 32 Amp complete all as specified and directed.
S&F in replacement MCB single pole 6 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
S&F in replacement MCB SPN 20 to 40 Amp 240 volt complete all as specified and directed.
S&F in replacement MCB SPN 63 Amp 240 volt complete all as specified and directed
M&L for DLP plastic trunking 105x50mm size with two compartment including flexible cover of size 2x40mm clip on partition with all necessary accessories such as joints for cover, base joints, internal & external angles, flat angle, flat junction, clips for housing of wires inside the trunking 1.0 m apart, accessories of site to run the trunking on wall of verandah all as specified and directed.
M&L for sub main wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 4 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. ( Note :- Two runs of 6 sqmm FRLS and one run of 4 sqmm FRLS copper conductor shall be measured as one unit length.)
M&L for surface sub main wiring with 4x10 Sqmm FRLS copper conductor PVC insulated unsheathed cable in wall for sub main wiring including 2x 6.0 Sqmm FRLS PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. (Note :- (i) Four runs of 10 sqmm FRLS and two run of 6.0 sqmm FRLS copper conductor shall be measured as one unit length (ii) PVC DLP trunking will be measured and paid separately in respective item of sch.)
M&L for surface sub main wiring with 4x16 Sqmm FRLS copper conductor PVC insulated unsheathed cable in wall for sub main wiring including 2x10.0 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. (Note :- (i) Four runs of 16 sqmm FRLS and two run of 10.0 sqmm FRLS copper conductor shall be measured as one unit length (ii) PVC DLP trunking will be measured and paid separately in respective item of sch.)
S&F surface and wall mounted 20W LED extruded aluminium batten fiitting provided for efficient heat dissipation (Make :- Philips Cat No : BN021C LED20S PSU CW GR S2 or equivalent to specified make.)
S&F surface and wall mounted LED 10W extruded aluminium batten fitting with rod complete. (Make :- Philips Cat No: BN021 LED10S-6500 PSU GR S1 / C&S Cat No LTTB2F10WLEDP/W or equivalent to specified make.)
S&F in replacement of building security LED light 14 watt with IP-65 including suitable size of GI bracket complete all as specified and directed. (Make: Philips Cat No BRP042 LED 14 CW MR S1 PSU GR or equivalent to specified make.)
S&F in replacement of 42W aesthetically designed 600x600x70 mm LED flat panel for surface mounting which prpvides soft-light and glare free symmetrical illumination ( Make : Havells Cat No : PLUTOSURFACE 2x2 PLS42WLED857S or equivalent to specified make.)
S&F in replacement of suspended/surface mounted 32 W LED luminaire, 4 feet x 1 feet with diffused optics, lumen output 2900 lm, 50,000 burning hours and CRI 80, 6500 K, surg protection 2 KV, fixed on existing steel conduit pipe as suspended down rod complete all as specified and as directed by Enginer-in-Charge (Make :- Philips Cat Part No- SM270C LED 30S 6500 PSU WH orequivalent to specified make.)
M & L Earthing complete with galvansied steel earth plate electrode 600x600X6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below ground level earth plate connected with 4 mm dia GI wire as earthing lead by means of bolts, nuts, check nut and wahers of galavanised iron all as shown in Electrical plate No.3 of MES Sch part I and testing on completion. Including neccessary excavation and earth work, adequate common slat, charcoal dust and funnel PCC (1:3:6) type C-1 pit with pre-cast RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 8 mm dia bars, MS bar 3 Nos both ways funnel with 20, mm dia GI grade watering pipe earthing lead with GI protection pipe medium grade 15mm dia up to 7.5m. from earth plate to equipment earth point complete all as specified including dismantling of existing earthing.
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in any kind of soil complete all as specified and directed.
Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of soft/loose soil complete all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply and lay sand with approved fine grade around cable in cushioning for protection of under ground cable complete all as specified and as directed
Supply and lay burnt best quality locally available old size sub class 'B' bricks laid in trenches perpendicular to U/G cable for cable protection complete all as specified and as directed.
M & L GI tube light grade for passing through cables under the floor ,along the wall or along the pole of 40 mm bore and fixed to the poles/walls with suitable size of MS clamps and nut and botls/washers etc including taking down old GI tubing complete all as specified and directed.
Supply and Lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete all as specified and directed.
Supply and Lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and directed.
Supply and Lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core complete all as specified and directed.
Supply and Lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 2 core fixed on wall/ceiling with suitable size PVC conduit and steel saddles complete all as specified and directed.
Fabrication, supply, installation, testing and commissioning of outdoor type feeder pillar box floor mounted , made out from 3.15 mm thick MS sheet ( CPRI type tested) with canopy type roof, over all size 0.75 x 0.60 x 0.30 mm, front operated, two part hinged doors with locking arrangement, including built in aluminium busbar of size 40 x 5 mm (4 x 45 cm long) on base insulator with heat shrinkable PVC sleeving having RYB-B colour code drilling holes for connection of incoming and outgoing cable, complete painting with two coat of synthetic enamel paint over a coat of red oxide primer, testing and installation on PCC/brick foundation, connection of cable with suitable aluminium lugs all as specified and directed.( Note :-MCCB will be measured and paid separately.)
S & F MCCB 63 Amps , 4 pole, 415 volts , 50 Hz , 16 KA breaking capacity with adjustable thermal magnetic release, with spreader links on both sides.
S&F in replacement of Busbar chamber in sheet metal enclosure 100 Amp, 8 way TPN 415 Volt of aluminium busbar drilled holes including cadmium coated nuts, bolts, washer etc fixed on wall complete all as specified and directed.
Fabrication , Supply, installation , testing & commissioning of floor mounted free standing totally enclosed dust and vermin proof LT control panel CPRI type tested cubical type of size 1.30 m x 1.60 m x 0.60 m (minimum size) fabricated out of 2 mm thick MS sheet steel front operated with locking arrangement for each switch gear & openable doors in back side of the panel, cable entry & exist from bottom with cable glands and gaskets, copper TPN bus bars 40 x 5 mm size for main bus bar and suitable size of copper strip for down bus bar of out going switch gear fixed on epoxy based rasin insulator of suitable sizes with internal wiring with 1.0 sqmm PVC insulated stranded copper conductor cable & bus bar shall be insulated with different colour code sleeves to indicate RYBN and to be connected with copper lugs including powder coated painting internally & externally and necessary PCC foundation work complete all as specified and directed comprising of the following items :- BUSBAR : Bus bar copper made of size 40x5 mm suitable for 3-phase for wire system of capacity with 400 Amps for RYB and 200 Amps rating for neutral. INCOMMING : (i) MCCB 4 pole, 200 amps, breaking cap 25 KA , 415V, 50 Hz AC with spreader link on both side -01 No (ii) On load change over switch 415 volt, 4 pole, panel mounting of capacity 200 Amp, front operated incl all arrangement for housing of the same in existing panel with suitable size copper lugs confirming to IS 13947 (Part-3); IEC 60947-3 (iii) Indicator lamp LED type (R, Y, B) - 01 Set (iv) Multifunction meter Accuracy Class 1.0 to measure the following parameters such as V, A, F, PF, kW, kVA - 01 No OUTGOING. (i) MCCB 4 pole ,160 amps, breaking cap 16 KA , 415V, 50 Hz AC with spreader link on both side -02 Nos (ii) MCCB 4 pole , 63 amps, breaking cap 16 KA , 415V, 50 Hz AC with spreader link on both side -04 Nos (iii) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity end terminated with lugs and bolts, nuts and washers of galvanised iron. (iv) Current transformer Ratio 400/5 amps, 15 VA accuracy class - 1 = 01 set of three
M & L Earthing complete with galvansied steel earth plate electrode 600x600X6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below ground level earth plate connected with GI strip (25x4) mm as earthing lead by means of bolts, nuts, check nut and wahers of galavanised iron all as shown in Electrical plate No.3 of MES Sch part I and testing on completion. Including neccessary excavation and earth work, adequate common slat, charcoal dust and funnel PCC (1:3:6) type C-1 pit with pre-cast RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 8 mm dia bars, MS bar 3 Nos both ways funnel with 20, mm dia GI grade watering pipe earthing lead with GI protection pipe medium grade 40mm dia up to 7.5m. from earth plate to equipment earth point complete all as specified including dismantling of existing earthing.
M/S YASHCON CONSTRUCTIONS
MS. BK BROTHERS AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .