Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.7 L+₹1.3 L (4.84%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹30.0 L+₹2.6 L (9.62%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹30.0 L+₹2.6 L (9.66%)Rejected-Finance NO 1 116 GANGAI AMMAN KOVIL STREET SORANJERY PATTABIRAM CHENNAI 600072 | CHENNAI | CHENNAI | TAMIL NADU | 600072 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹30.6 L+₹3.2 L (11.8%)Rejected-Finance NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L5 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
12 Jun 2025, 6:00 pmClosed
GE Avadi
Garrison Engineer , Muthapudupet, Air Force Area, Avadi, Chennai-55
REPAIRS TO RCC ROOF, CEILING AND WALL PLASTERING, VALLEY GUTTERS, RAIN WATER PIPE, GALVALUME SHEETS AND FALSE CEILING TO CERTAIN BUILDINGS IN 23 ED AF STN UNDER GE AVADI
2025_MES_709760_1
8269/E8
Open Tender
Civil Works
Item Rate
270 days
GE Avadi
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE Avadi
₹80,000
Yes
12 Jul 2025
23 May 2025
14 Jun 2025
23 May 2025
12 Jun 2025
31 May 2025
23 May 2025 - 27 May 2025
Amount
M&L for Complete Removal of existing water proofing treatment over roof including PCC of any thickness description in any position including cleaning the surfaces with wire brushing, watering and removing debris up to 1500 mtr distance etc complete all as specified and directed.
M &L for PCC 1:2:4 type B-0 (using 12.50 mm stone aggregate) Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
M&L for providing complete waterproofing treatment to roof surfaces, including laying 25mm thick PCC 1:2:4, type B-0 using 12.5mm graded stone aggregate as levelling course, and 10mm thick rendering in cement mortar 1:3, both mixed with integral waterproofing compound @ 0.8% by weight of cement (i.e., 200 ml per 50 kg bag), followed by preparation of the surface by thoroughly cleaning to remove all loose particles, dust and laitance. Apply a coat of bituminous primer conforming to IS: 3384 @ 1.0 kg/Sqm as tack coat, then apply hot blown bitumen grade VG-10 conforming to IS: 702 @ 1.20 kg/Sqm over a base coat of water-based bituminous primer @ 0.40 ltr/Sqm. Thereafter, lay APP (Atactic Polypropylene) based polymeric waterproofing membrane of minimum 3mm thickness, reinforced with non-woven polyester fabric (minimum weight 150 gms/Sqm) and total mass not less than 3.6 kg/Sqm with 100 mm overlaps, bonded using torch-on technique as per IS: 16540-2017 / IS: 16532-2017. The membrane surface shall be finished with a coat of solar reflective aluminium paint @ 0.1 ltr/Sqm. All materials shall conform to manufacturer’s specifications and IS standards, complete all as specified and directed
S&F 1000 ltr capacity triple layer, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed
S&F 500 ltr capacity triple layer, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position capacity 500 litres (Cleaning repairing, etc. measured separately)
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position capacity 1000 litres (Cleaning repairing, etc. measured separately)
S&F Ball valves, high pressure, with of PTMT with epoxy coated aluminium rod & high desity plastic ball screwed for iron pipe of 25 mm bore (Minimum weight 455 gms )and fixed complete all as specified and directed.
S&F of gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
Taking up or down steel tubing and connections, including removal to store etc all as directed for 15 mm bore all as specified and directed.
All as per Item No 10.00 above but for 20mm bore
All as per Item No 10.00 above but for 25mm bore
S&F Unplasticised PVC pipes and fittings of 15mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed
All as per Item No 13.00 above but for 20mm bore
All as per Item No 13.00 above but for 25mm bore
M&L for Cutting chases or making holes in brick walls for concealed water tubing, making good to facings where required, cutting not exc 10 cm girth all as specified and directed.
Taking down plastering on lathing (other than wire-netting), without removing lathing, in cement or cement-lime mortar (one side only measured in cases where both sides are plastered) etc complete all as specified and directed.
M&L rendering 10mm thick on surface of brick /concrete surface in CM 1:3 all as specified surfaces finished even and smooth without using extra cement on ceilings all as specified and directed.
M&L rendering 10mm thick on wall/vertical surface of brick work/concrete work in CM 1:6, surfaces finished even and smooth without using extra cement all as specified and directed.
M&L for 5 mm thick cement plaster in CM 1:4 with WPC over 10 mm thick dubbing coat in CM 1:6 finished even and fair on wall surfaces of brick/ concrete works all as specified and directed. Note: WPC shall be measured and paid separately.
M&L for preparation of newly plastered surfaces and applying three coats of white wash on ceilings all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash on walls all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer all as specified and directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets all as specified and directed.
M&L in repairs perforated particle board/ tiles for insulation and accoustic purposes, 600x600 mm and 12mm thickness in size, fixed with nails to timber framework or with staples on snap grid all as specified and directed.
M&L in repairs anodised aluminium snap grid frame work for false ceiling all as specified and directed.
M&L in repairs Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed.
M&L in repairs hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
S&F false ceiling of Non asbestos fibre cement building boards, manufactured from homogeneous mixture of cement, quartz and cellulose and cured with high pressure steam using auto claving process confirming to IS-14862, of size 600 mm x 600 mm x 4 mm thick fixed over snap grid frame work of T section (main & cross member) of size 25 mm x 25 mm x 1.5 mm thick in square pattern of grid size 600mm X 600mm . The aluminium fram work will supported on side wall with the used of aluminium 'L' section of size 25 mm x 25 mm x 1.5 angles etc. Snap grid shall be supported with hangers of 4 mm dia. Galvanised iron wire adjusting level fixed to roof slabs / truss etc by means of ceiling cleats made out of Galvanised iron flat of size 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete including necessary removal of existing electrical fittings and re-fixing in position without disturbing existing connected fittings all as specified and directed.
Supply and fixing in repairs Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering/ cladding to wall fixed with self tapping screws all as specified and as directed.
Supply and fixing in repairs Pre-painted galvalume aluminium zinc coating GI based ridge with plain steel sheet 0.50mm of an colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws complete all as specified and as directed.
Supply and fixing in repairs Pre-painted galvalume aluminium zinc coating GI based valley gutters plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa fixed with self tapping screws complete all as specified and directed.
S&F in repairs 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall complete all as specified and directed.
S&F PVC in repairs (SWR) of dia 160 mm rain water pipes conforming to IS 13592 type 'B' including necessary rubber ring joints fix with valley gutter along wall or clading all as specified and directed.
S&F 160 mm dia PVC (SWR) bends any radious all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings and refixing the same after fixing/ positining of the new valley gutters all as specified and directed.
M&L for holes filling in pre-painted galvalume plain or corrugated steel sheets in hangars with butyl adhesive aluminium waterproof heavy duty leakage repair flashing tapes of size 40 to 60mm length and width and etc all as specified and directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed
S&F MS Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 etc complete all as specified and directed
S&F Mild Steel hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters running bars for doors, balusters, nosing to steps including embeding in concrete and screwing, etc,. wind ties for roof including securing bolts; post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh, etc.,), bolting or riveting, etc., and similiar work confirming to Fe-290 Gde E-165 all as specified and as directed
Material & Labour for preparing new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of Synthetic enamel paint over a coat of Red oxide zinc chrome primer, complete all as specified and directed.
Material & Labour for preparing new steel Surfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of Synthetic enamel paint over a coat of Red oxide zinc chrome primer, complete all as specified and directed.
Supply and installation of high performance industrial roof vent of 600 mm dia neck of aluminium alloy designed to meet ASS-2428 dated 28 Jan 93 to wind speed of 200 Km/hr and to the entry of wind driven rain at a range of 2.5 litre per second inclusive of base plate and including all accessories all as specified and as directed
SUNLEY CONSTRUCTIONS (BID ID -3319761)
M/s Omm Muruga Enterprises (BID ID -3313663)
Mariammal Constructions (BID ID -3312781)
SAMYDOSS CONSTRUCTIONS (BID ID -3321420)
SAI SRI HARSHA ENTERPRISES (BID ID -3321017)
SRI KRISHNA AGENCIES (BID ID -3311689)
Shri Varaghaa (BID ID -3313613)
S K ENTERPRISES (BID ID -3313293)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .