| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC 15 BOH ROAD DEFENCE ENCLAVE AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹39.8 L+₹85,061 (2.18%)Rejected-Finance BIR SARDALIA RESIDENCY AIR FORCE ROAD BARYAL UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance Other Than Lowest Bidder | |
| 3 | L3₹40.8 L+₹1.9 L (4.81%)Rejected-Finance VILLAGE POST JAGANOO TEHSIL UDHAMPUR JAGANOO UDHAMPUR1 UDHAMPUR JAMMU KASHMIR 182124 UDYAM JK 22 0011509 | UDHAMPUR | JAMMU AND KASHMIR | 182124 | L3 | Rejected-Finance Other Than Lowest Bidder | |
| 4 | L4₹41.8 L+₹2.8 L (7.20%)Rejected-Finance | L4 | Rejected-Finance Other Than Lowest Bidder | |
| 5 | L5₹41.8 L+₹2.8 L (7.30%)Rejected-Finance | L5 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
₹43.4 L
EMD Value
₹87,000
Closing Date
10 Mar 2022, 6:00 pmClosed
GE Army Dhar Road Udhampur
GE Army Dhar Road Udhampur
SPECIAL REPAIR TO BLDG NO P-06 OR MD ACCN AT PREM VIHAR AT 16 CORPS ZONE WKSP UNDER GE ARMY DHAR ROAD
2022_MES_506078_2
8067/NIT-67/2021-22
Open Tender
Civil Works
Item Rate
180 days
Dhar Road
As tender Documents
6 documents required · 6 mandatory
₹500
GE ARMY DHAR ROAD UDHAMPUR
₹87,000
Yes
10 May 2022
23 Feb 2022
11 Mar 2022
23 Feb 2022
10 Mar 2022
24 Feb 2022
Amount
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each complete.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing and as directed by Engineer-in-Charge .
S&F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails MS frames shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom raid on either side and as gap insert for top rail on either side andas gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rials with suitable PVC sheet beading, and joined together with solvent cewment, suppling and fixing in the frame at site as per specification and drawing as directed by Engineer-inCharge.
S&F Pressed steel frames of size 125 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, (thickness of sheet shall be 1.25mm) and making good the wall with plaster in CM 1:6 complete all as specified an directed.
S&F for pressed steel frames of size 105 X 60 mm for doors with one or more rebates including necessary fixing lugs hinges, locks strike plate etc, (thickness of sheet shall be 1.25mm) and making good the wall with plaster in CM 1:6 complete all as specified.
S&F for pressed steel frames of size 75 X 60 mm for Cubboard frames with one or more rebates including necessary fixing lugs hinges, locks strike plate etc(thickness of sheet shall be 1.25mm) and making good the wall with plaster in CM 1:6 complete all as specified.
M&L PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for filling in back of pressed steel door frame/chowkhat and fixing of bed block of hold fast etc complete all as specified and as directed.
S&F 35 mm thick 2nd class factory Made Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkat all as specified and directed
35mm thick flush shutters, solid core construction, with block board core and plywood face panels commercial type on both sides, complete all as specified.
S&F galvanised mild steel wire cloth 0.36 mm nominal dia of wire and avarage width of aparture 1.40mm and fixed etc complete all as specified.
Dismantling boarding, any description, fixed in any position with nails all as specified and as directed.
M&L for 18 mm thick water proof solid Medium Density Fibre (MDF) board prelaminated both side(Approved colour) for Door/ Cupboard shutters/ shelves and partition of required size fabricated by jointing and fitted with necessary arrangement as in cupboard shutter/ backside/partition/shelves etc fixed with each other using solvent cement adhesive and stainless steel screws. the visible edge of board/ shutter shall be lipped with 18mm wide and 1mm thick edges leaping tapes as per manufacturer instructions, complete all as specified and directed.
S &F 125 mm extruded Brass handle fabricated type polished complete all as specified and as directed.
S&F continuous (piano) hinges 30mm width of flap, mild steel bright finish or electrogalvanised of complete all as specified.
S&F magnetic catcher suitable for kitchen cabinet shutter complete all as specified and directed
S&F Aluminium anodised 100 mm long Butt hinges type B-21 with galvanised mild steel screws complete.
S&F Aluminium anodised barrel tower bolts, 150 mm long of extruded section complete all as specified and directed.
S&F 125 mm long Aluminium anodised barrel tower bolts, etc.complete all as specified.
S&F 200 mm long aluminium , anodised barrel tower bolt of extruded section and fixed. complete all as specified and directed.
S&F Aluminium anodised handles, cast type anodised 100 mm long complete all as specified and directed.
S&F 125 mm long cast type Aluminium anodised handles etc.complete all as specified.
S&F Aluminium anodised handles, cast type anodised 150 mm long complete all as specified and directed.
S&F 300 mm long aluminuim alloy, anodised , sliding door bolt with hasp staple (bolt type) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.
Door eye viewer, viewing angle 180 degree, mounting diameter 14mm, total size 4 x 2.5cm (LxD) with good quality glass eye lens, , brass chromium plated fixed in position for door shutters, complete all as specified & directed.
Door seal brush Ialuminium plate with nylon brush) of required length for any size of door, fixed with stainless steel screw, complete all as specified and as directed. Make Harrision or equivalent
S&F 100mm length door stopper of aluminium alloy body and tongue,anodised fixed to door complete all as specified.
300mm ordinary rat tail rod pattern door spring including roller and roller plate of mild steel, fixed to chowkhats/welded to chowkhats as directed, complete all as specified.
S&F 100 mm long aluminium anodised hasp and staple safety tape including bolts to hinge plate and fixed with screws complete all as specified and as directed.
Powder coated Aluminium windows/vents complete all as specified in particular specification and as shown on drawings for various sizes and pattern with following powder coated aluminium sections :- Notes:- A. The rates quoted for powder coated aluminium sections shall be deemed to include the following:- (i) The aluminium section and fittings shall be Pure polyster powder coated of thickness not less than 50 microns. (ii) Rubber gasket for fixing glass to windows/vent shutters. (iii) Fixing of window in openings with and including min 75x10 GI screws all around @ 300C/C (Min 2 Nos on one side) with PVC RAWL PLUGS/Sleeves. (iv) Rollers, concealed lock cum handle & other fittings for sliding shutters shall be provided as per manufactures instructions and approved by GE. (v) Silicone sealant shall be applied on internal as well as external periphery of window and masonry joint to avoid water seepage. (vi) All other sundries all as per manufacturer instructions and as directed. B. The rates quoted for powder coated sections shall exclude the cost following and shall be paid seerately under respective items of Sch`A'/BOQ:- (i) Glass and wire mesh (ii) 40x40x3 aluminum angle provided on all corners of the windows. (c) Aluminum-U-channel shall be provided for fixing of wire mesh. (d) Powder coated aluminium handles and hinges for fixing of openable shutters C. OTHER (i) No allowance for wastage/overlaps shall be considered for payment. (ii) Range of dimension of opening size has been mentioned. The same shall be fixed as per measurements of opening of windows as per site requirement by the GE/EIC during execution of work. (iii) Powder coated aluminium section shall be provided all as shown on drawings and as directed.
THREE TRACK powder coated aluminium section as in window/vents frame for sliding shutters.
Powder coated aluminium sections as in window/vents frame for openable shutters.
Powder coated aluminium sections as in sliding window shutters.
Powder coated aluminium sections as in openable window shutters.
Powder coated aluminium tower bolts 75mm long and fixed.
Powder coated aluminium butt hinges 75mm and fixed.
Powder coated aluminium handle 75mm and fixed.
Powder coated aluminium plate type II Gate and shutter, hook and eyes 100mm and fixed.
Sheet glass 4 mm thick ordinary quality for fixing to aluminium windows with all necessary fixing arrangement, complete all as specified.
Stainless steel pipe of 20mm dia, heavy grade with and including fixing brackets, stops, rollers etc., in cupboards, complete all specified & directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), terrazo dado/wall tiling and skirting. etc on brick or stone walls etc including racking out joints hacking for key and scrubbing removing serviceable tiles to store and rubbish off the premises etc complete all as specified.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.00 Kg of cement per sq m all as specified and directed.
M&L for non skid ceramic cololured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm. in floors over 10 mm thick screed bed or bedding layer of mortar 1:4 for laying floor finishes etc complete all as specified. Make Somnay/Kajaria or equivalent make.
M&L for non skid ceramic cololured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm. In vertical portion including rendering 10 mm thick in CM 1:4 etc complete all as specified.Make Somnay/Kajaria or equivalent make.
S&F glazed ceramic coloured tiles 300x200x7mm thick in verticle surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade. etc complete all as specified.Make Somnay/Kajaria or equivalent make.
Pre-Polished kota stone as in flooring/treads of stair,18- 20 mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, laid over and including 20mm screed layer in cement mortar 1:3, complete all as specified. Notes:- 1. Single piece kota stone shall be provided in treads of stair as per site requirement. 2. Slabs of not less than 550mm x550 shall be provided in all other places of flooring.
Pre-polished kota stone, 18-20 mm thick as in vertical surfaces such as skirting/dado/riser of steps etc., laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, laid over and including 10mm thick plastering in cement mortar 1:3, complete all as specified. Notes:- 1. Single piece kota stone shall be provided in riser of stairs as per site requirement.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. over 15mm thick screed bed etc. all as specified
Demolition of cement concrete in any position n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for 50 mm thick in Plain cement concrete type C2 ( 1:3:6)( using 20 mm graded aggregate ) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) finished even and smooth at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight all as directed at site.
M&L for providing cement concrete Type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as nominal mix in lintels upto 1.5m clear span, cills, steps, parapets, copings, bed plates, and the like including weathering, slightly rounded or chamfered angles and throating, as directed including use of form work etc
M&L for providing precast cement concrete type B0 1:2:4 (12.5 mm graded aggregate) louvres and jallies 35mm thick (measured solid) including all moulding set in cement mortar 1:4 complete all as specified. .
Demolition of RCC of any descrition such as Kitchen chimney, chajja, shelves, OHT Tanks. etc and in any position not other wise specially provided for complete all as specified and directed by Engineer in Charge (reinforcement cut as required to facilitate demolition)
M&L for RCC nominal mix type B 1 (1:2:4) (20 mm graded aggregate) in chajja.
M&L in repair for RCC nominal mix type B 1 (1:2:4) (20 mm graded aggregate) in beams, cantilever, bressummers,lintels etc.
M&L for precast RCC type B1 (1:2:4) (20graded agg) set in cement mortar 1:4 as in landings, cover slab, chulha hood, chajja, sheleve and similar articles with plain faces complete all as specified
Use and waste of form work to edge of concrete flat treads breaks in floor window cill concrete railling opening of concrete walll, floor, roof n.exc 20 cm wide and side of RCC bands in wall horizontal/sloping and similar works exc 10 cm but n.exc 20 cm wide for roughed finished surfaces of concrete.
Formwork to chullah hoods, chajjas, troughs and similar items including edges
M&L for form work to the sides and soffits of floor or roof beam, beam, lintels,shelves incl supporters all as spcified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified
,-ditto- all as per item No 52 but 6 to 8 mm dia
M&L for taking down existing roof treatment of any description and any type and position and removing the debris from site outside MD land all as specified and directed by Engr-in-Charge
15mm thick plastering in cement mortar 1:4 (mixed with WPC as per manufacturer instruction) on roof surfaces after applying cement slurry @ 3kg/Sqm, surface finished even and smooth without using extra cement, complete all as specified. Note: WPC shall be measured and paid for seperately under respective item
Supply only liquid water proofing compound
M&L for providing and laying 40mm thick PCC (1:2:4) using 20mm graded agg with WPC Compound complete all as specified and directed by Engineer-in-Charge.(WPC will be paid seperately)
M&L for Roof treatment for Non Accessible Roof :- priming the roof surface with bituminous primer conforming to IS-3384 @ 0.30 ltrs/Sqm and applying a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20 Kg/Sqm and thereafter provide polymeric water proofing membrane (five layered) of weight not less than 3 Kg/Sqm with centre layer core of 90 micron high molecular density polyethylene film followed by another coat of semi hot blown 85/25 grade bitumen @ 1.20 Kg/Sqm blinded with fine sand in dry condition @ 0.50 Kg/Sqm, Top surface of roof after carrying out treatment as specified here in above as per manufactur instructions, complete all as specified
M&L for Roof tretment for accessible roof :- priming the roof surface with bituminous primer conforming to IS-3384 @ 0.30 ltrs/Sqm and applying a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20 Kg/Sqm and thereafter provide polymeric water proofing membrane (five layered) of weight not less than 3 Kg/Sqm with centre layer core of 90 micron high molecular density polyethylene film followed by another coat of semi hot blown 85/25 grade bitumen @ 1.20 Kg/Sqm blinded with fine sand in dry condition @ 0.50 Kg/Sqm,complte all as specified and directd.
Taking down old PCC tiles from roof and removing bedding at any position all as specified and directed
M&L Cement concret coloured tiles with cement and no pigment 30 cmX30 cm x20mm thick machine pressed set jointed and including 15mm screed bedding in CM 1:4 as pointed in neat cement slurry in flooring as cut and poslished all as specified.
M&L for making benching with PCC (1:2:4) type B0 using WPC along side wall adjoining to roof in concave shape complete all as specified. Note : WPC shall be measured and paid saparetly.
S&F chicken wire mesh of size 12.5mm and wire dia 0.51mm (24SWG) hexagonal construction, stretched firmly for roof treatment complete all as specified and as directed..
Demolition of brick work of any type built in cement mortor in foul condition etc complete all as specified
M&L for brick work sub class B brick straight or curved on plan to any radius in half brick thick wall built in CM 1:4 complete all as specified.
M&L for brick work built in cement and sand mortar 1:6 with sub class 'B' old size bricks straight or curved on plan exceeding 6m means radius including wall for crumple joint complete all as specified and directed by Engr -in-Charge.
M&L for RCC nominal mix type B1 (1:2:4) (20 mm graded aggregate) as in slab
Cutting holes in brick walls built in cement mortar including making good dismantled portion in CM (1:3) or cement concrete (1:2:4) type B-1 exc half brick but n.exc one brick complete all as specified.
Water proofing treatment to floor & vertical surfaces of sunken portion complete comprising the following: - (a) Demolition of floor & lime/concrete etc. remove all loose particles along with existing water proofing treatment (any no. of layers) and cleaning by wire brush to remove all dirt and cleaning the surface with water. (b) Proving 60cm long, 40mm dia GI medium grade spout pipe by making holes and making the surface good. (c) Brushing neat cement slurry with 1.2 kg of cement per square metre duly blended with & including water proofing compound. (d) Rendering 15 mm thick in cement mortar (1:3) mixed with water proofing compound on sunken surface including walls. The corner of sunken portion shall be rounded in concave shape and adequate slope shall be made during plastering to accommodate sump pipe and curing the sunken portion with water minimum for 48 Hrs by ponding. (e) Applying a coat of bituminous primer confirming to IS [email protected] lit/sqm. After drying of primer apply a coat of hot blown 85/25 grade bitumen @1.2kg/sqm. (f) Applying self adhesive type APP(Atactic Poly-propylene polymer) modified membrayester non-woven mat (PF) reinforecement. (g) PCC 1:7 :12 for filling of sunken portion after conceling all menbrane and sealing all joints with sealing compound of MC Bouchemie/Roofex/Forre/Choksy/Dr Beck&Coty/FOSROC.
Taking down Cement plaster including raking out joints hacking for key scrubbing down with water etc
M&L for rendering 15mm thick in cement mortar in 1:4 on fare face of brick work or concrete surfaces even and smoothe without using extra cement & with using integral water proofing compound
M&L for rendering 10 mm thick in cement mortar 1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement
M&L for 5 mm thick cement plaster on brick or concrete surfaces, as in ceiling / facia / chajja etc. in cement mortar 1:3 finished even and smooth without using extra cement, all as specified .
M&L for complete removal of existing treatment on external/internal wall by scraping, sand papering or by using mechanical sander all as specified and as directed by Engr-in-Charge.
M&L for complete removal of existing treatment on ceiling by scraping, sand papering or by using mechanical sander all as specified and as directed by Engr-in-Charge.
M&L for two coat of exterior emulsion paint (Weather Coat) over one coat of acylic primer on any type of wall, roof boarder, drops, fins, chajja / roof facia, column etc, including preparation of old surfaces complete all as specified.
M&L for preparing new plastered wall surfaces Applying two coats of OBD of approved tint on new plastered surface over a coat of 2 mm thick wll care putty complete all as apecified and directed.
M&L applying three coat of white wash on prepared surfaces of new plastered surface of wall etc complete all as specified.
M&L for applying three coat of white wash on newly plastered surface of ceiling etc complete all as specified.
M&L Two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden surfaces of any description, over 10 cms in width or girth not otherwise described
M&L Two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation of new steel surfaces of any description, over 10 cms in width or girth not otherwise described
S&Fin repair stainless steel plate racks of size 750mm x 900 x 250mm and thickness of SS strip of 1mm fixed on wall etc complete all as specified.
S&F in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe incl sink coupling, 40mm waste fitting, overall size915mmx460mm with bowl size 410 mm x 330mm x 160mm, etc complete all as specified and as directed.
S&F in repair Sink mixer with regular spout wall mounted with connecting legs and wall flanges and including all necessar fitting, complete all as specified. Make:ESS ESS Cat Part No. EC-12
S&F in repair 15 mm dia bore fancy type chromium plated bib taps with wall flange cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe, or for brass ferrule complete all as specified and as directed.
S&F in repair Soap tray brass chromium plated and fixed to plugs on wall with brass screws, complete all as specified.Make: ESS ESS Cat Part No. AC 703
S&F PVC (SWR) floor trap with grating including jointing with solvent cement, 75mm diameter of outlet, all as specified.
S&F in repair Wall mixer with provision for overhead showes with 115mm long bend pipe on upper side, connecting legs and wall flanges, complete all as specified and directed.Make:ESS ESS Cat Part No. EC-10
S&F in repair Towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified.Make: ESS ESS Cat Part No.AC 701
S&F in repair Towel ring brass chromium plated, fixed with brass screws and plugs, complete all as specified. Make: ESS ESS Cat Part No. AC702
S&F in repair Corner glass shelf 200mm (brass brackets), fixed with brass screws and plugs, complete all as specified Make: ESS Cat Part No. AC 207A
S&F in repair Brass chromium plated shower rose of 200mm size with arm and with or without swivel joints, fixed in repairs, complete all as specified.Make: ESS ESS Cat Part No. RF 202 for Shower and Cat Part No. SA-105 for shower arm
S & F in repair Angle valve with wall flange, 15mm bore, fancy type, chromium plated with long shank and cup, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specified. Make: ESS ESS Cat Part No. T-112B
S & F in repair PVC connections 15mm size with Brass nuts of length 600mm, fixed in repairs, complete all as specified. Make: Prayag Cat Part No. BCT-04
Vitreous China, wash hand basin, flat back white of size 450mmx350mm including brackets, brass CP waste coupling 32mm dia with long screwed shank and fly nuts,32mm dia, chain and plug, porcelain stopper including cutting for and pinning in ends of brackets or erecting stand with and including PVC collapsible waste pipe of suitable length, fixed in repairs, complete all as specified.Make: Cera Cat Part No. S 2040102
S&F in repair Chrromium plated brass Centre hole mixer without pop up waste system 15mm bore for mixing hot and cold water screwed down for iron pipe for WHB, complete all as specified.Make: ESS ESS Cat Part No. T-118
S&F in reapir Mirror cabinet PTMT of 400mmx500mm with magnetic locking arrangement fixed with and including wooden plugs with chromium plated brass screws, complete all as specified. Make: Prayag Cat Part No. 554
S & F in repairs Vitreous Chinaware squatting pan, orissa pattern size 580mm x 440mm with integral foot rests, white, with cast iron ‘P’ or ‘S’ trap, front or back inlet, including provision of lime concrete, making connections to trap and to flush pipe etc. and making good to floors, fixed in repairs, complete all as specified.Make: Cera Cat Part No. Calina S 3010102
S&F in repair PVC valveless, with top button double action type,syphonic action type flushing cistern, 10 litres capacity, low level, white with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe, fixed in repairs, complete all as specified. ake: Prayag Cat Part No. 504
S&F in repair Peg set of six, stainless steel of suitable length, complete all as specified. Make: Prayag Cat Part No. BEA 30
Taking up or down GI tubing 15 mm bore pipe including cleaning for re-fixing or removal to store.
S&F GI tubing 15 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 15 mm complete all as specified.
Ditto- but refixing 15 mm dia ,old steel tubuing and connections in new or old possition (wall,ceiling and floors etc)
M&L for 25mm dia fancy type PVC coated on MS Pipe coloured curtain rod with brackets and knobs at both ends as per site requirement including taking down old existing PVC conduit pipes with accessories complete all as specified and directed. Note : The cost of brackets and knobs is deemed to be including in the quoted rate.
Taking up or down GI tubing 20 mm bore pipe including cleaning for re-fixing or removal to store.
S&F GI tubing 20 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm complete all as specified.
Ditto- but refixing 20 mm dia ,old steel tubuing and connections in new or old possition (wall,ceiling and floors etc)
S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks staging/cage and similar work con- forming to Fe.290.Gde-E-165 complete all as specified.
S&F for expanded metal exc 4 Kg cut to length bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia all fixing with galvanised steel stapple fixed to steel or wood members laid in any position incl closing after filling.
Dismantling water tank and remove to Store of capacity exc 500 but not exc 1000
S&F 1000 ltrs capacity Rotational moulded polyethylene in white coloured three layered ISI Marked water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as per specified and directed.
S&F in repairs 20mm gun metal globe or gate valve with iron wheet head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F Ball valve, high pressure with PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or fixed of size 20 mm bore, fixed in repairs.(Min Wt 20mm- 210 gms)
S&F GI Tank nipple 20mmsuitable for HDPE water tank min wt for 15mm-38gm/20mm-45gm
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
Taking down rain water pipe and eaves gutters (any size and pattern) including all fittings heads shoes bends swan necks etc including cleaning or refixing or removal to store(measured overall as fixed along the centre line over fittings and accessories)
S&F PVC(SWR) pipes, 110 mm external dia double socketed in any length with rubber joints, fixed to walls with PVC brackets/clips complete all as specified.
Dismantling of cast iron or PVC pipes including all fittings and accessories, 100/75 mm dia and in any position all as specified.
S&F PVC(SWR) pipes, 75 mm external dia double socketed in any length with rubber joints, fixed to walls with PVC brackets/clips complete all as specified.
S&F PVC(SWR) bends suitable for 110 mm external dia complete all as specified
S&F PVC(SWR) bends suitable for 75 mm external dia complete all as specified
S&F PVC (SWR) junction single, (single T) equal or unequal of 110mm dia
S&F PVC (SWR) junction single, (single T) equal or unequal of 75mm dia
S&F PVC (SWR) junction single, (Double T) equal or unequal of 110mm dia
S&F PVC (SWR) junction single, (Double T) equal or unequal of 75mm dia
S&F PVC (SWR) vent cowl of 110mm bore
M&L for welding in repair n.exc 2.5 cm in length to metal of any thickness to be welded all as specified and as directed.
M&L for providind RCC nominal mix 1:2:4 incl necessary formwork and providing plaster of 1:3 and two coats of finishes over a coat of primer for RCC projected portion as in drawts, facia, fins etc incl demolition of existing and providing TMT bars if reqd all as specified and directed. ( Note Length of drawts,fins,facia shall be measured irrespective of any thickness and heigth)
Providing of anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron., complete all as specified.
Anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors, complete all as specified.
M&L for repair of RCC slab,coloumn,beam by removing of old portion of concrete and cleaning/brushing and removing of loose concrete/ applying required cement slurry @ 3.5 Kg/Sqm making goog with concrete 1:1.5:3 and applying 3 mm thick cement mortar 1:4 and finish the surface all as specified and directed.
M&L 75mm thick PCC (1:4:8) type B2 using 40mm graded aggregate as in sub base of interlocking tiles complete all as specified as directed.
Machine pressed precast concrete interlocking paver block, shape and size as approved by the GE, confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 25mm thick sand cushioning, complete all as specified and as directed.
Providing precast cement concrete type B1, 1:2:4 (20mm graded aggregate) , kneelers, apex stones, kerb stones, with plain fair faces, including chamfers, weathering's, throating etc. and setting in mortar 1:4 incl demolition of precast concrete articles ,kerb stone of any discription and laid in any position complete all as specified and as directed.
Excavation in trenches n.exc 1.5m wide & n.exc 1.5m deep for foundation, etc. or for shafts, wells, cesspits, manholes, etc. not exc 10 Sqm on plan and not exc 1.5 m depth & getting cut in soft/loose soil complete all as specified.
Returning filling in including spreading, levelling, watering & well ramming in layers not exceeding 25cm thick all as specified.
Removal of excavated material to a distance exceeding 250m & deposited where directed at level not exceeding 1.5m above the starting point.
Demolition and breaking up 150mm internal dia of drain pipes (SGSW) set in cement mortar and laid in trenches incl all fittings & accessories
Reinforced concrete pipes, class NP2, laid & jointed complete with collars, bore of pipe 150 mm, complete all as specified & directed.
Concrete bed to 150mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret M-10 (Nominal mix) type C-2 using 40mm graded stone aggregate, and tested, complete all as specified & directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for 150 mm dia pipe complete all as specified and directed.
M&L Cement concrete 1:3:6 type C-2, using 40 mm graded crushed stone aggregates as in surface channel and drains, complete all as spd and directed.
Demolition and breaking up 600 mm internal dia of drain pipes (SGSW) set in cement mortar and laid in trenches incl all fittings & accessories
S&F 600mm dia reinforced concrete pipe class NP3 laid and jointed complete with collars with cement mortor (1:1) all as specifed and directed.
M&L for cement concrete 1:3:6 type C-2 using 40 mm graded coarse aggregate in bed to drain pipes of 600 mm bore including packing under and completely surrounding pipes with concrete after they are laid and tested.
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M & L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable complete all as specified and directed.
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 50 mm bore for protection of cable including dismantling existing pipe complete all as specified and directed by the Engineer-in-Charge.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 30 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wal or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 35 Sqmm 3.5 core with required aluminium cable lugs all as specified and directed. Make of Cable : Havells, Polycab, Nicco, Gloster,Finolex
Taking out 40mm dia old unserv GI water tubing lines and connected unserviceable pipe and fitting includidng segregation of serviceable pipe and fittings and keep in safe custody and reuse serviceable pipe line and fitting from tranch/ in ground/under road /under PCC path etc the site of work complete all as specified and as directed.
Taking out 25mm dia old unserv GI water tubing lines and connected unserviceable pipe and fitting includidng segregation of serviceable pipe and fittings and keep in safe custody and reuse serviceable pipe line and fitting from tranch/ in ground/under road /under PCC path etc the site of work complete all as specified and as directed.
Taking down old unserviceable gate valve 25 mm dia
Taking down old unserviceable gate valve 40 mm dia
M&L for GI water tubing 40 mm dia medium grade and laid in trenches/floors with running fittings complete all as specified and directed of following sizes :-Make of GI Water Tubing medium grade - TATA/JINDAL/SURYA PRAKASH., Make of GI FITTINGS- Only ISI marked Fittings.
M&L for GI water tubing 25 mm dia medium grade and laid in trenches/floors with running fittings complete all as specified and directed of following sizes :-Make of GI Water Tubing medium grade - TATA/JINDAL/SURYA PRAKASH., Make of GI FITTINGS- Only ISI marked Fittings.
M&L for GI water tubing medium grade 25 mm dia fixed on walls or laid on floor of following sizes incl taking down from walls/on floor and making good the disturbed surfaces all as specified and directed :-
supply and fixing Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron/GI pipe 25 mm dia
supply and fixing Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron/GI pipe 40 mm dia
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc
M&L for Cement Concrete 1:4:8 type D-2 (Nominal Mix) using 40 mm graded coarse aggregate as in foundation filling and mass concrete in manhole complete all as specified and directed.
M&L for framed work as in man hole cover of angle or other section with gusset plates, rails, braces etc, complete drilled for fixing of steel sheeting or other covering, Door etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging and also fastening and fixing complete all as specified and directed.
Taking down old unserviceable fan regulator any type
Taking down Old unserviceable call bell any type
Taking down old unserviceable submain wiring any size 4/6 Sq mm 02 run copper conductor single phase with earth wire including PVC conduit
Taking down old unserviceable FTL /bulk head/security light/Lamp etc light fitting any type ant sketch
Taking down old unserviceable MCB DBs any type SPN/TPN incl MCBs
M & L for concealed point wiring on wall and ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) all as specified and directed by Engineer-in-Charge for the following :-
One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
All as per item No 168 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S&F switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and as directed. Make -Havells/Cona/Anchor/Legrand
S&F switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts including complete all as specified and as directed. Make -Havells/Cona/Anchor/Legrand
S&F socket outlet 3 pin, 6 Amp piano flush type including complete all as specified and as directed. Make -Havells/Cona/Anchor/Legrand
S&F socket outlet, 2 in 1, 3/5 pin 6 / 16 Amp, piano flush type complete all as specified and as directed Make -Havells/Cona/Anchor/Legrand
S&F piano bell push 5/6 Amps SP flush type, complete all as specified and as directed. Make -Havells/Cona/Anchor/Legrand
S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed. Make -Havells/Cona/Anchor/Legrand
S&F for batten angle lamp holder insulated body with back plate suitable for batten fittings including complete all as specified and as directed.Make -Havells/Cona/Anchor/Legrand
S&F Ding dong sound door call bell electric AC 240 volt, 50 Hz ding dong type including taking down unserviceable complete all as specified and as directed.Make -Havells/Cona/Anchor/Legrand
Supply & Fixing medium step type fan regulator 240 Volt AC, socket size, medium step" ISI marked complete all as specified and directed. Make -Havells/Cona/Anchor/Legrand
M & L for sub main wiring with two run of FRLS PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 4.00 Sqmm FRLS PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments incl PVC conduit medium grade 25 mm dia and PVC insulated copper conductor cable drawing in PVC rigid conduit , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FRLS PVC insulated shall be measured and paid as one unit length.
Supply & Fixing SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 complete all as specified and directed. Make- Legrand cat no 507611 or eqvts of L&T/Schenider (Electric)
Supply & Fixing MCB SPN, 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make- Legrand cat no 408618 to 408620 or eqvts of L&T/Schenider (Electric)
Supply & Fixing MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make- Legrand cat no 408609 to 408617 or eqvts of L&T/Schenider (Electric)
Supply and fixing MCB TPN, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make- Legrand cat no 408683 or eqvts of L&T/Schenider (Electric)
Supply and fixing TPN Distribution Box double door of protection grade IP 43, in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way, confirming to IS 13032 & 8623 including chasing/cutting of wall and concealed and making good as existing surface complete all as specified and directed. Make- Legrand cat no 507670 or eqvts of L&T/Schenider (Electric)
S&F Wall mounted LED batten 18/20 Watt with 01 No LED tube rod, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete all as specified and directed. Make- CG cat No LDL-20-CDL or equvts of Havells/Philips/Wipro
S&F Wall mounted Mirror light LED fitting, 10 Watt, 2 Feet long incl integrated electronic driver including dismantling taking down unsv sketch fitting any type complete all as specified and directed.Make- Crompton Cat No LDL-10-CDL or equvts of Havells/Philips/Wipro
S&F decorative wall mounnted luminaire with & including 09 watt LED lamp complete as directed and specified Make- Havells cat No LHFOAJE1TN1I060 or eqvts of CG/Philips/Wipro
S&F LED building security light 35 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade suitable size dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed. Make- Crompton Cat No LSTS-36-CDL-M or equvts of Havells/Philips/Wipro
Supply only LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL/LED Bulb. Make- Havells/CG/Philips/Wipro
Taking down existing ceiling fan serviceable type and deposite MES safe coustedy all as directed
Taking down existing Exhaust fan serviceable type and deposite to MES for safe coustedy all as directed
Supply & fix fans ceiling complete 230 V,1200 mm sweep. BEE rated white colour including all fixing arrangement and connection with 3 core flexible copper cable all as specifed and directed . Make- Crompton/Bajaj/Havells
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep 900 RPM with louver including cutting of hole of adequate size including making good existing surfaces incl fixing with MS fasnut all as specified and directed Make- Crompton/Bajaj/Havells
Taking down Old unserviceable rusted earthing plates
Taking down old unserviceable / defective energy meter any type any capacity and deposite to MES E/M store all as specified and directed
Supply & fix AC single phase static energy meter of accuracy class 1.0, 240 V, 50 Hz with Backlit LCD display of rating 5 - 30 A, (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power alongwith transparent hinge type PVC meter box including connection with thimble , PVC flexible pipe and proper sealing all as specified and directed . Make- L&T/Havells/Schenider/HPL
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
SARDALIA CONST CO
NARESH KUMAR KHAJURIA
S.K CONSTRUCTION
VISHWA MITTAR PACHYALA
M/S PAWAN KUMAR ANAND
JINDAL BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .