Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹35 LAccepted-AOC | 1 | Accepted-AOC Awarded | |
| 2 | 2₹37.4 L+₹2.2 L (6.26%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹41.2 L+₹6.0 L (17.0%)Rejected-Finance | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹41.2 L+₹6.0 L (17.0%)Rejected-Finance | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹43.9 L+₹8.7 L (24.8%)Rejected-Finance | 5 | Rejected-Finance Not being lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
25 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (North) Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
PLOUGHING AND CERTAIN B/R AND E/M MAINT WORKS AT LBT PBT ETC IN KK RANGES (AF) UNDER GE (N) AHMEDNAGAR
2024_MES_644081_1
8825 / E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Garrison Engineer (North) Ahmednagar
Class D Cat a(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer(North) Ahmednagar
₹98,000
Yes
2 May 2024
26 Feb 2024
27 Mar 2024
26 Feb 2024
25 Mar 2024
11 Mar 2024
Amount
Demolition of brickwork or stone bouilder masonary built in cement mortar or lime mortar complete all as specified
M&L for Walling of random rubble,uncoursed well bonded, bedded and solidly hearted built in CM 1:6 complete all as specified
M&L for brickwork with fly ash modular bricks straight or curved on plan exc 6m mean radius,built in CM 1: 6 complete all as specified
Taking down cement mortar plaster on brick or stone walls, raking out joints, hacking for key complete all as directed
M&L for rendering, 15 mm thick on stone surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering, 15 mm thick on brick / concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparation old plastered surfaces of walls and apply two coats of OBD, finished with roller finish on plastered surfaces of wall any height including scaffholding etc complete all as specified and directed
M & L for preparation of new plastered surfaces of wall and applying two coats for cement based paint any height including scaffholding etc complete all as directed.
M & L for preparation of old plastered surface of wall and applying one coats of cement base paint any height including scaffholding etc complete all as directed.
M & L for preparation old plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/old surfaces.
M&L for preparation of old plastered or unplastered surfaces of walls including cornices etc by brooming down or steel wire brushing scraping down smook soot, moulds, moss and efflorescent salt, trading oil and greasy spots and applying one coat of white lime wash at any height including scaffholding etc complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old plastered or unplastered surfaces of walls including cornices etc by brooming down or steel wire brushing scraping down smook soot, moulds, moss and efflorescent salt, trading oil and greasy spots and applying two coat of white lime wash at any height including scaffholding etc complete all as specified and directed by Engineer-in-charge.
Material and labour for sun dried brick work in mud mortar including removing the mud debris of old target out of target area complete all as specified and as directed.
Material and labour for mud plastering, 25 mm thick on walls / floors wherever required complete all as specified and as directed.
Cross ploughing over areas, ranging from 20 to 30 cms deep including removing of shrubs, roots, bushes upto 15cm girth picking up stones exceeding 1" in overall size coming up while ploughing and removing the shrub, bushes, roots , stones etc. to a distance exceeding 200 m and not exceeding 250 m complete all as specified and as directed.
Filling in depression formed in the area during exercise of rocketing and gunnery and levelling the surfaces to match with the adjoining surface all as specified and as directed Note :- (1)The soil shall not be digged from outside MD land and the soil spread from adjoining area to be collected (from high level area), filled and levelled as directed, Crusher dust shall also be provided to fill the depression of bombings wherever found necessary to make the surface even, no extra payment will be given for thus brought crusher dust, complete all as per specified and directed by Engineer in charge (ii) The stones/pebbles poped out during the bombing shall be collected and to be filled in deep pits formed during the bombing, durig the filling of the same. (iii) Service shall be provided as and when required basis from 5.00 Am to 10 Pm. (iv) Filling shall be inspect by the target clearance team the quantity shall be verified prior to filling. (v) In case of contractor not complete the work with in time period as per direction of Engr-in-charge a penalty at the rate of Rs. 10000/- per day and recovery for the same shall be effected from contractor's dues. A separate register shall be maintained in the office Engineer-in-Charge. (vi) Mode of measurement will be plan area of the depression formed (Item No a,b) (a) Depth upto 1.00 mtr
b) Depth 1.00 mtr to 5.00 mtr
Supply and laying bamboos / ballies 6.5 m in length, dia not less than 8 cms at one end and not less than 6cm at other end complete all as specfied and as directed..
Cutting the bushes / vegetation / shrubs / thorny plants / trees of any type and not exc 30 cm in girth including roots growing up in the line of sight from watch tower to gunnery area and watch tower to target area and removing to a distance exceeding 150 m but not exceeding 200 m from the area and disposed off complete all as specified and as directed.
Supply only Sand filling in floor or paving laid in layer not exc 15cm thick spread, levelled and rammmed including watering etc complete all as specified and directed.
Supply only empty polypropylene bags white in colour of 50 kg (1.25 cft) capacity, which is generally used for storing cement as per sample approved by GE . (i)The bags as per approved samples by GE supplied by the contractor shall be deposited first in store yard of AGE B&R-II GE (North) as per the demand in three phases of the total contract period as per the direction of Engineer-in-Charge and same shall be issued by the department to the contractor/his authorized ref as per required at site. A register shall be maintained by concerned JE in the office of Engineer-in-Charge for the stores / materials supplied by the contractor to the department and then issued by the department to the contractor on reqd basis. The register shall be kept in the custody of concerned office. (i) Contractor shall provide bags with in time as per direction by Engineer-in-Charge. In case of failure by the contractor, a penalty at the rate of Rs. 5000/- per day and and recovery for the same shall be effected from contractor's dues. A separate register shall be maintained in the office Engineer-in-Charge
Supply of crushed stone sand for filling in empty polypropylene bags any place of firing range/target required size and shape as per direction of Engr-In-Cahrge
Filling crushed stones in empty polypropylene bags and placed in circle wise position of required size and shape including stitching of polypropylene bag, for shifting of bags complete all asspecified and directed. Note (i) Service shall be provided as and when required basis from 5.00 Am to 10 Pm. (ii) Exept crush sand, Paid labour carge in each bags.
Dismantling carefully the existing LT overhead line ACSR conductor of any size from its position by necessary disconnecting of conductor and removing complete all as specified and as directed
Dismantling of unserviceable insulator of any type complete from its position and removing all as specified and as directed
Dismantling of unserviceable existing cross arms made from channels, angles and unserviceable FI clamps, nuts, bolts etc from OH line and removing complete all as specified and as directed
Dismantling of existing LT poles carefully of any size and type from its position carefully and removing from the site and necessary excavation and earth work in any type of strata, demolition of concrete, disconnecting of conductor etc all as specified and as directed .
S&F stay assembly complete with accessories as shown in Electrical Plate No 1 of SSR 2009 (Part I) using stay rod 20mm dia, including clamps made out of 50 x 6mm MS flat, MS galvansied stay plate 300mmx 300mm x 6mm and galvanised thimble including insulator 90x140mm all as specified and as directed. (loop type insulator, stay clamps, excavation and concrete shall be measured and paid separately
M&L for prunning and removing of tree branches touching to electric over head lines wild growth around LT /HT over head lines and around pole and stay complete to make clear span of 2 Mtr of tree both side of the OH line with JCB, Cutter and all tools, plants etc all as directed by Engineer-in-Charge. Note : (i) Distance between pole to pole will be measured and paid. (ii) Contractor has to take upmost care to avoid damage to existing lines/structures if Any breakdown of line caused during punning shall be made good without any extra cost. (ii) Prunning of tree to be done twice a year (before & after rainy season) (iii) The contractor has to ensure the proper safety of the tradesmans to avoid any mishappening. If any mishappening occures the contractor will be solely responsible for it.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers etc welding bending cold or hot, drilling holes for bolts , in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one inishing coat of aluminium paint all as specified and as directed.
M & L for replacement of Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade
M & L for replacement of shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers,insulator bolts, washers and nuts, 100mm height and 115mm dia including two nos of galvanised steel strap of size 31x5mm fitted with 14mm dia bolts and nuts all as per directed.
Labour for restringing of LT over head line consisting of 4/5/6 conductors retrive from ser item no-01 by dismantling taking down,unserviceable , damged ACSR conductor, repairing wherever required including cutting, re-joining and restringing in, with proper sag, binding to insulator with and including aluminium binding wire complete all as specified and directed. Note : (i) Only good and serviceable conductors are used, unserviceable conductors will be credited to contractor under schedule of credit. (ii) Rate of Transporting of conductor from one site to another site is included this rate.
Supply, fixing and stringing ACSR conductor (Weasel/ Ferret) for over head line securing on pole complete including binding wire, jointing sleeves aluminium tap and PG clamp etc of any size all as specified and as directed. (Note :- (a)jumper on cutout point/2 pole structer/4 pole structure shall be provided with PVC insulated sleeve. (b) Rate is inclusive of jumpers materials & tree branch cutting to make a safe distance from over head line.)
Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil and added additional 1.5 m or part thereof in depth beyond the first 1.5 mtr.
All as per serial item No 35 above but in Hard / dense soil
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil.
Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point.
Supply & lay HDPE pipe 63 mm bore for laying of LT cables etc complete with all accessores all as specified and directed
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, ISI Marked, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:- (a) 16 sqmm 4 core
(b)120 Sqmm 31/2 core
M/L for GI pipe light grade 100 mm dia Tubes, with all fitting and fixed complete to walls and ceilings or laid in floors complete for protection of cables
M & L for making good the damaged Tar Road by using additional stone metal, PCC etc
Demolation of u/s cement concrete in coppings all as directed.
M & L for PCC(1:4:8) type D-2 using 40mm grade stone aggregates as foundation of pole and similar work all as specified and directed.
M&L cement concrete (1:3:6 ) type C2 using graded stone aggregate as in Copping of pole including demolation of existing damagable cooping necessary form work all as specified & directed.
Supply, erecting and fixing in replacement of true vertical position of steel tubular swaged pole, 9 mtr long complete with cast iron base plate, finial taper plug, bolt, nuts and screws as specified and of type 410 SP-31, conforming to relevant IS, including one primer coat of red oxide and two coats of aluminium paint and two coats of bituminous paint inside and outside of botton portion up to 1.8 mtr length all as specified and provide circular bend 1 No of length 2 m complete all as specified and directed. (Excavation and earth work , foundation concrete and PCC coping shall be measured and paid separately)
Material and labour for street light control board / box of size 0.50 X 0.50 X 0.20 m made out of 1.60 mm thick MS sheet fixed / mounted on pole by means of 2 Nos of FT clamps of size 25 X 3 mm comprising the following enclousers and connecting with suitable size of copper cable all as directed:- a) MCB, TPN, 63 Amps, - 01 No MAKE:L & T/ STANDARD OR equivalent in makes mentioned in list of makes in Appendix `C' b) Timer switch, Astronomical type operating on 110 / 240 / 415 Volts, 50 Hz MAKE: L&T OR equivalent in makes mentioned in list of makes in Appendix `C' c) Contactor ML 2, 32 Amps,415 Volt - 01 No MAKE: L&T OR equivalent in makes mentioned in list of makes in Appendix `C' d) All MCB,Contactor should be connected through HRC fuse
S&F High Mast Light control board / box of size 0.50 X 0.50 X 0.20 m made out of 3 mm thick MS sheet fixed / mounted on 50 x 50 x 6 mm angle iron frame having minimum 2 ft ground clearance duly ambedded in and including PCC blocks (1:2:4) type B1 foundation for fixing of panel complete including incoming and outgoing connections with sutaible size of lugs / gland / nuts / bolts complete all as specified and directed:- a) MCCB, TPN, 63 Amps, - 01 Nos. b) Timer switch, Astronomical type operating on 110 / 240 / 415 Volts, 50 Hz. c) Contactor- 63 Amps, 415 Volt - 01 Nos. d) Contactor- 9 Amps, 415 Volt - 02 Nos e) Bypass switch 01 Nos. f) Indicator Lamp RYB. g) Control fuse 6A 01 Nos
Lifting the Highmast pole 16 mtr height by crane from its own location with opening the nut boltt and washers , greasing the steel wire rope and fixing with pulley and reassembling and refixing at its orginal location, including reconnections and testing commissioning complete for smooth operations all as specified and directed. Note: (i) Rate for Crane and labours is being to be includes in Quoted rates. (ii) Rate of sundry items like grease, cotton waste, nut , bolt and washers are deemed to be quoted rates.
Supply and fixing in replacement of MCB TPN 63 Amps with breaking cap 16 KA and connecting all as directed . Make : Legrand / L&T/Siemens.
Supply and fixing in replacement of MCB DP, 40 Amps with 10 KA breaking / rupturing capacity including neccssary connection complete all as directed. MAKE: Legrand/ L&T/Siemens.
Material and labour for spray painting the LT Steel tubular pole,11/9 mtr long with two coats of synthetic enamel paint including prepartion of surfaces,Scraping the old paint and writing pole No in Black letter under yellow circle all as directed.
Supply,installation,testing and commissioining factory made LT feeder pillar panel CPRI approved, size of panel 1.0 x 0.3 x 0.6 mtr as per CPRI Specification,double door floor mounted outdoor type,as per IP-65 grade,made out of CRCA sheet 3.15 mm thick of outer body with Aluminium bus bar 200 Amps,4 strip,(3 phase & Neutral) complete drilled,insulated with colour coaded insulation tape,mounted on insulators etc. Panel should be dust proof,vermin proof,powder coated,locking should be screw type,mechanical type,inter locking,should have danger notice for 415 volt,AC,mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearanceduly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs, glands , Nuts & Bolts complete all as required and directed. (i) Incoming MCCB 4P 100 Amp, 36 KA -01 No( Ics = 100% Icu) (ii) Phase indicating LED lamps (R-Y-B) -01 set Notes:- 1. The rates Quoted shall include for earth work,Plinth protection around the panel apprx 75cm and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board. 2. All MCCBs should be handle operated
Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed. Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates.
Supply and spreading in electrical outdoor installation yard, stone aggregate of size 20 mm at 11KV substations / Near DP structures after through cleaning, anti grass treatment etc all as per pecified and as directed.
Supply & fix LT line seperator 3/4 lines made of high quantity PVC material to provide 300 mm distance between phase to phase and neutal or as per sit reuirement as directed by Engineer-in-charge
Supply and Lay HDPE pipe 50 mm dia for laying of LT cables etc complete with all accessores all as specified and directed. Make: Vectus Industries/ Supreme/Infra/Astron Plastic/Jain Irrigation
Taking out existing unsv UG cable and Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:- (a) 10 Sqmm 2 Core
(b) 10 Sqmm 4 Core
Supply and replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension GI wire, twin core cable flat or circular with size 4sqmm. Note : Rate of 4 mm GI wire included in quoted rate
All as per Item No 62 above but 10 sqmm 2 Core
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply and fix in replacement of LED Street light Luminaries 60 watt, with inbuilt surge protection 10 KV, Lumans output 6000 with pressure die-cast aluminium housing with polycarbonate moduler secondary lens optic & IP 66 protection and impact resistance IK07 fixed with suitable size of GI Bracket of length 1.2 Mtr,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 core copper wire from junction box to streeght light and 4 sqmm 2 core aluminium service cable pvc insulated 2.5 RM per fitting where over head line existing for connection of street light to over head conductor complete all as specified and directed. Make : Havells/Philips/Wipro
Taking up or down GI steel tubing and connections from trenches / walls / floors etc cleaning for re-fixing for following pipe of dia complete all as specified and as directed. (a) 50mm bore
(b) 40mm bore
(c) 25mm bore
(d) 20mm bore
(e) 15mm bore
Supply and fix GI pipes, medium grade including necessary fittings such as sockets, elbows, tees, reducers, unions, nipples etc laid in trenches / walls / floors etc for following pipe of dia complete all a s specified and as directed. (a) 15mm bore
(b) 20mm bore
(c) 25mm bore
(d) 40mm bore
(e) 50mm bore
Material and labour in repairs gun metal gate valve/brass stop valve, high pressure both ends screwed down with crunch or butterfly handle with suitable size sockets on both ends nipples, unions, etc suitable for following GI pipe of dia complete all as specified and as directed. (a) 15mm bore
(b) 20mm bore
(c) 25mm bore
Drilling and tapping cast iron / ductile iron water mains, in position, for branch connections of the internal dia 20 to 50 mm all as directed.
S&F Ball in repair brass valves,high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed (a) 20 mm bore
(b) 25 mm bore
Supply and fix in repair union suitable for following GI pipe of dia complete all as specified and as directed. (a) 15mm bore
(b) 20mm bore
(c) 25mm bore
(d) 40mm bore
(e) 50mm bore
Supply and fix in repair Nipple length 6'' suitable for following GI pipe of dia complete all as specified and as directed. (a) 15mm bore
(b) 20mm bore
(c) 25mm bore
Supply and fix in repair Elbow suitable for following GI pipe of dia complete all as specified and as directed. (a) 15mm bore
(b) 20mm bore
(c) 25mm bore
(d) 40mm bore
(e) 50mm bore
Supply and fix in repair Socket medium grade ISI Marked suitable for following GI pipe of dia complete all as specified and as directed. (a) 15mm bore
(b) 20mm bore
(c) 25mm bore
(d) 40mm bore
(e) 50mm bore
MATOSHREE CONSTRUCTION
M/s. N D Karande
M/s. A P INFRA
M/s AG PATHAN
M/s. Sagar Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .