Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.2 LAccepted-AOC 18 M S NORTH EAST ENTERPRISE SIJUBARI HATIGAON GUWAHATI ASSAM 781038 | KAMRUP METRO | ASSAM | 781038 | L-1 | Accepted-AOC Being the lowest bidder against quoted item | |
| 2 | L-1₹15.6 LAccepted-AOC 103 S J HOUSE 1ST FLOOR SITARAM MILLS COMPOUND N M JOSHI MARG LOWER PAREL MUMBAI 400011 MAHARASHTRA | MUMBAI | MAHARASHTRA | 400011 | L-1 | Accepted-AOC Being the lowest bidder against quoted item | |
| 3 | L-1₹11.7 LRejected-Finance 1 BISHNU RABHA PATH GUWAHATI KAMRUP ASSAM 781028 | KAMRUP METRO | ASSAM | 781028 | L-1 | Rejected-Finance Financially disqualified | |
| 4 | L-2₹7.1 LRejected-Finance NA TRIBENI PATH G S ROAD GANESHGURI GUWAHATI KAMRUP ASSAM 781006 | KAMRUP METRO | ASSAM | 781006 | L-2 | Rejected-Finance Financially disqualified |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Feb 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
PI, Dr. Subhash Medhi
PI, Dr. Subhash Medhi, Dept. of Bioengineering and Technology, GU
Supply of various items for the DHR Project entitled Molecular Biology Applications Research and Diagnostic Techniques
2025_GU_42295_1
GU/BET/DHR/2024-25/STII/1 Dated 21.01.2025
Open Tender
Composite Works
Item Wise
15 days
Gauhati University
Please refer Tender documents.
3 documents required · 3 mandatory
₹800
₹80,000
5 Mar 2025
22 Jan 2025
13 Feb 2025
22 Jan 2025
13 Feb 2025
22 Jan 2025
Laboratory Items
PC based True double beam UV-Visible Spectrophotometer Specification: 1. Optical system: Czerny-Turner mounting, Single monochromator, Double- beam system, 1,300 lines/mm, 240 nm blazed holographic grating 2. Light source: Deuterium lamp and Tungsten-Halogen lamp 3. Detector: R-928 Photomultiplier tube 4. Wavelength range: 185 to 900 nm or higher 5. Wavelength accuracy: ±0.1 nm (656.1 nm) 6. Wavelength repeatability: ±0.05 nm 7. Spectral bandwidth: 0.1, 0.2, 0.5, 1, 2, 5 nm in steps 8. Resolution: 0.1 nm 9. Stray light: Max. 0.005 %T (220 nm NaI) 10. Mode: Abs, %T, %R, 11. Photometric range: -5 to 5 Abs 12. Noise level: 0.00003 Abs RMS (500 nm) 13. Wavelength slew rate: 14000 nm/min 14. Wavelength scan rate: 4000 to 0.5 nm/min 15. Below items must be supplied along with the main instrument: a) One Pair of cuvettes, 10 mm path length, 3.5 ml volume b) Integrating Sphere Attachment Wavelength range: 220 nm to 850 nm or better i) Samples like Powder, Solid, colloidal sample, Thin Film etc are measured by using this accessory ii) Minimum Inner diameter of integrating sphere: 60 mm c) Branded i5 PC with Original OS- 1 no
Class II, Type A2 Bio-safety Cabinet Specification: 1. The Bio-safety cabinets should be 4 feet width with front window must be a 10” sash opening and steel with smart coat interior 2. The Bio Safety Cabinet must include DC motors. 3. The motor must automatically adjust the airflow speed without the use of a damper to ensure continuous safe working conditions, even without maintenance adjustments. 4. Cabinet must use a pressure sensor (rather than anemometer) to detect pressure drop across the supply filter, rather than in just one point across the down flow. 5. The cabinet should display the inflow and down flow air velocities and must incorporate an LED Indicator, visual & audible alarm to indicate excessive HEPA filters loading, blower failure, airflow speed failure, Incorrect window position. 6. The front of the cabinet must be angled 10º to help minimize glare. 7. The cabinet noise level must be less than 65 dB(A) for a 4-foot cabinet. 8. Cabinet with lights on and fan at operating speed should consume less than 400 watts or less 9. The cabinet must automatically reduce fan/blower motor speed to 30% when the front window sash is in closed position to ensure reduced energy consumption when the cabinet is not is use. 10. UV light must be programmable to allow for specific exposure times from 0 to 24 hours. 11. The Cabinet should have provision to fit taps for Vacuum, Water and Non-combustible gas. 12. The Bio safety Cabinet should be NSF certified with listing on NSF website. 13. The Bio safety cabinet should incorporate HEPA filter of the class H 14 EN 1822 or better and having minimum efficiency of 99.995% at 0.3 µm particle size. 14. Ventilation System Exhaust and Inflow air volume approx 300-350 CFM 15. Audible and visual Alarms for HEPA filter failure, blower failure, airflow speed failure, Incorrect window position. 16. The cabinet should be provided with fixed / adjustable Height Stand, UV Light and one set of detachable arms rest and one / two electrical outlet. 17. The Drain Pan of the BSC should be made of Stainless Steel. The drain pan should not be painted, or power coated. 18. Cabinet should be CE certified and declaration of MOC should be provided. 19. Port provision for clean and safe routing for vacuum tubing and cables through the side of the BSC for improved organization and work efficiency.
Vacuum Oven Specification: 1.Volume(L): 60-80 2.Temperature range (°C): RT+5-250 3.Temperature resolution (°C): 0.1(at 100°C) 4.Temperature variation (°C): ± (at100°C) 5.Heating power (W): 2100 6.Vaccum range 0 ~ 1 atm 7.Timer: 1min ~ 99hr59min 8.Vaccum connector (mm): Ø10 9.Venting connector (mm): Ø10 10.Inner size (mm): 400x400x400 11.Dimension (mm): 625x585x710
Constant Temperature Incubator Specification: 1.Volume: [L] 100 2.Temperature Range [°C]: RT.+ 5~65 3.Temperature uniformity of working area [°C]: <±0.2 at 37°C and 25°C RT 4.Temperature Stability [°C]: ±0.1 at 37°C 5.Temperature Controller: Digital Display with PID automatic regulation, Button Control 6.Timer 1 min ~ 99 hr 59 min 7. Safety: Independent safety temperature protection, Open door alarm function 8. Heating Capacity [W]: 340 9.Shelves [included / max.]: 3/4 10.Inner Dimensions [WxDxH in mm] 480 X 480 X 495 11.Outer Dimensions [WxDxH in mm] 560 X 560 X 760 12.Power supply AC 220~240 V, 50/60 Hz
Hydraulic Analogue laboratory press Specification: 1.Type: Hydraulic 2.Diameter of Spindle: 35 millimeter 3.Maximum Load on Piston: 25 tonne 4.Closing Force (kN): 200 5.Piston Stroke: 22 millimeter 6.Capacity per platen (kW): 1.6 7.Specific Platen Pressure (N/mm2): 1.05 8.Press Platen Size (mm): 196 x 196 9.Depth: 480 millimeter 10.Heating Type: Electrical 11.Width: 790 millimeter 12.Cylinder Stroke: 100 millimeter 13.Display: Analog 14.Width Between Pillars: 150 millimeter 15.Height: 970 millimeter 16. Accessories: Pneumatic front shield, Mould cart (moveable) or Mould rack 17. Maximum Temperature: 200°C 18. Temperature Accuracy (degree Celsius): +/- 1.0
High Performance Computer Specification: 1.Capacity (in kVA/kW): 2kVA/2kW Single phase Input/Single phase output 2.Technology and Capability a) True online double conversion UPS, VFI-SS-111 b) UPS should be designed at Rated PF of 1 c) 3- level IGBT based inverter and rectifier d) Should have arrangement for paralleling up to 4 UPS for redundancy, if required Input 3.Input facility-Phases/ Wires: 1-phase/2-wire & Gnd (Phase & Neutral + Ground) 4.Input Voltage Range: 160-300 VAC (On 100% Load) 5.Input Power factor: ≥0.99 (With full linear Load) 6.Input Current Harmonic Distortion (THDi): <5% at full load in normal UPS operating voltage 7.Generator Compatibility: Compatibility to genset supply required 8.Input Frequency Range: 44-66 Hz Output 9.Nominal Output Voltage: 230 V (adjustable to 220/230/240 VAC) 10.Output Voltage regulation: ±1% 11.Nominal Output Frequency: 50/60 Hz ± 0,1 % 12.Output wave form: Pure sine wave 13.Output Voltage distortion (THDv) <: ~2% Full Linear load ~<5% Full Non-Linear load 13.Crest Factor: 3;1 Efficiency AC/AC (Overall efficiency): Up to 92%
Electroporation System (Eukaryotic and or Prokaryotic System) Specification: 1.Outputs: Waveform: Exponential-decay or square-wave Voltage: 10-3000 V 2. Capacitance: 10-500 V: 25-3275 µF in 25 µF increments 500-3000 V: 10,25,50 µf3. Parallel resistance: 20-1000Ω in 50 Ω increments, plus infinity 4.Simple resistance: 20Ω minimum at 10-2500 V 600 Ω minimum at 2500-3000 V 5.Square wave timing: 10-500 V: 0.05-10 ms duration in 0.05 ms Increments, 10-100 ms duration in 1 ms Increments, 1-10 pulses, 0.1-10 sec interval 500-3000 V: 0.05-5 ms duration in 0.05 ms Increments, 1-2 pulses, 5 sec minimum intervals
Molbiogen
North East Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .