Loading…
Loading…
Tender Value
₹2.0 Cr
EMD Value
₹2.5 L
Closing Date
2 Feb 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
16 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Note: In case, date of tender inviting is on or after date of statutory deadline for audit of balance sheet of previous FY (i.e. 30th Sept or as further extended for this FY), audited balance sheet of 4th previous year shall not be considered unless concerned CA certifies that balance sheet is not audited yet as on date of invitation of this tender.
The contractor should have valid Electrical Contractor License issued by Govt. and submit along with tender document. If valid Electrical Contractor License is not submitted along with tender document, then offer will be summarily rejected.
16 conditions · 3 needing a document upload
The tenderer shall submit all relevant documents as detailed in para 14 & 18.10 of Tender Form (Second Sheet) of Part I of GCC work-2022.
The tenderer shall submit copy regarding status of firm i.e. sole proprietorship, partnership, Company, Society/Trust etc. and also submit a power of attorney and other relevant documents as detailed in Para no. 15 of Tender Form (Second Sheet) of Part- I of attached GCC-2022.
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. Following documents shall be submitted by the tenderer:
a) Sole Proprietorship Firm: (i) All documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(b) HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC- 2022.
(c) Partnership Firm: (i) A notarized copy of the Partnership Deed or a copy of the Partnership deed registered with the Registrar. (ii) A notarized or registered copy of Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm. (iii) An undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm / LLP in which they were / are partners / members. Any Concealment / wrong information in regard to above shall make the bid ineligible or the contract shall be determined under Clause 62 of the Standard General Conditions of Contract. (iv) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(e) Company registered under Companies Act 2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(f) LLP (Limited Liability Partnership): (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney / Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm / LLP or JV in which they were / are partners / members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(g) Registered Society & Registered Trust: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he / they be partner(s) of the firm or any other person, specifically authorizing him / them to sign the tender, submit the tender and further to deal with the Tender / Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association / Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he / they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Appostille certificate.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should quote only the above/below percentage on estimated value, in the space provided at web portal for the purpose & nowhere else. Financial & Technical conditions quoted at any place other than prescribed space shall not be entertained while evaluating the offer.
Tenderer are required to go through the documents attached along with the tender and submit their bids accordingly.
Power Supply Up gradation and system improvement at 11 Major load centers (BKN, LGH, SOG, HMH, SGNR, SSA, HSR, BNW, SDLP, CUR & RTGH) over Bikaner Division
33-EL-BKN-E-Tender-25-26~NWR
33-EL-BKN-E-Tender-25-26
Open
Works - General
10 Months
Bikaner, Rajasthan
₹0
₹2.5 L
2 Feb 2026
9 Jan 2026
19 Jan 2026
156 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,02,65,372 | ||
| — | 2.00 | — | — | ||
| Supply of 11 kV 250kVA 11kV/0.4kV copper wound, Dyn-11 outdoor type transformer with off load change over on HV side of range +5% to -10 % in steps of 2.5 %, oil immersed natural air cooled and standard fitting and accessories including first fill of oil, Buchholz relay with shut off valve, confirming to IS 2026 & IS 1180 (Part-1) : 2014 or latest amendments and as per spec. | — | — | — | 9,50,000 | |
| — | 2.00 | — | — | ||
| Erection, testing and commissioning of Outdoor type transformer 250 kVA (as a new or in replacement), 11kV/415V, 3 phase,50Hz, Oil cooled, copper wound complete with oil and other accessories including making of transformer plinth/Foundation of suitable height and fencing as per site requirements and as mentioned in specification. Necessary tools/ropes/manpower is to be arranged by the Contractor. The cost also includes crane charges and foundation of suitable height as per requirement if required as per site condition. | — | — | — | 77,574 | |
| — | 2.00 | — | — | ||
| Supply of 11 kV 500 kVA 11/0.4 kV copper wound, Dyn-11 outdoor type transformer with off load change over on HV side of range +5% to -10 % in steps of 2.5 %, oil immersed natural air cooled and standard fitting and accessories including first fill of oil, Buchholz relay with shut off valve, confirming to as per IS 1180 (Part-I): 2014 with latest amendments. | — | — | — | 18,05,400 | |
| — | 2.00 | — | — | ||
| Erection, testing and commissioning of Outdoor type transformer 500 kVA (as a new or in replacement), 11kV/415V, 3 phase, 50Hz, Oil cooled, copper wound complete with oil and other accessories including making of transformer plinth/Foundation of suitable height and fencing as per site requirements and as mentioned in specification. Necessary tools/ropes/manpower is to be arranged by the Contractor. The cost also includes crane charges and foundation of suitable height as per requirement if required as per site condition. | — | — | — | 1,22,964 | |
| — | 120.00 | — | — | ||
| Material and labour for Construction of concrete masonry plinth below ground level with M10 concrete for provision of electrical equipment like HT / LT Panels, DG sets, etc. along with provision of HT and LT cable incoming / outgoing including excavation and refilling as per requirement. Note: (i) The foundation drawings shall be made according to the electrical equipment. (ii) Necessary form work, shuttering and finishing of surfaces are included in the scope of work and the quoted rates are deemed to be inclusive of this provision. | — | — | — | 6,99,240 | |
| — | 120.00 | — | — | ||
| Material and labour for Construction of concrete M20 masonry plinth above ground level with plastering for provision of electrical equipment like HT / LT Panels, DG sets, etc. along with provision of HT and LT cable incoming / outgoing including excavation and refilling as per requirement. Note: (i) The foundation drawings shall be made according to the electrical equipment. (ii) Necessary form work, shuttering and finishing of surfaces are included in the scope of work and the quoted rates are deemed to be inclusive of this provision. | — | — | — | 7,49,160 | |
| — | 800.00 | — | — | ||
| Laying, testing & commissioning of 11kV / 33 KV XLPE cable in air / ground / in trench / spun / HDPE pipe, with transportation from main depot to required site, and as per specification enclosed. Note: - HT cable will be issued / provided by Railways. The contractor will be responsible for collection of cables from the Elect Maintenance / Works Depot including loading, unloading, transportation and return of un-used cables back at Depot. Cost of these provisions is deemed to be included in this item. | — | — | — | 1,09,600 | |
| — | 22.00 | — | — | ||
| Supply, fixing and commissioning HT 11 kV XLPE heat shrinkable HT Cable end box indoor type Suitable for HT Cable Size 70-120 sq.mm.as per requirements. Make- Raychem, 3M, Denson, Cabseal or similar. | — | — | — | 1,58,642 | |
| — | 22.00 | — | — | ||
| Supply, fixing and commissioning HT 11 kV XLPE heat shrinkable HT Cable end box outdoor type Suitable for HT Cable Size 70-120 sq.mm.as per requirements. Make- Raychem, 3M, Denson, Cabseal or similar. | — | — | — | 2,28,624 | |
| — | 22.00 | — | — | ||
| Supply, fixing and commissioning HT 11 kV XLPE heat shrinkable HT Cable end box indoor type Suitable for HT Cable Size 120-185 sq.mm.as per requirements. Make- Raychem, 3M, Denson, Cabseal or similar. | — | — | — | 2,34,366 | |
| — | 22.00 | — | — | ||
| Supply, fixing and commissioning HT 11 kV XLPE heat shrinkable HT Cable end box outdoor type Suitable for HT Cable Size 120-185 sq.mm.as per requirements. Make- Raychem, 3M, Denson, Cabseal or similar. | — | — | — | 2,44,156 | |
| — | 22.00 | — | — | ||
| Supply, fixing and commissioning of LT Heat shrinkable Straight through Joint size (25 sqmm to 50 sqmm) as per requirements. Make- Raychem, 3M, Denson, Cabseal or similar. | — | — | — | 50,160 | |
| — | 22.00 | — | — | ||
| Supply, fixing and commissioning of LT Heat shrinkable Straight through Joint size (70 sqmm to 150 sqmm) as per requirements. Make- Raychem, 3M, Denson, Cabseal or similar. | — | — | — | 57,838 | |
| — | 6.00 | — | — | ||
| Supply, fixing and commissioning of Straight through cable joint kit suitable for 11KV, "E", 3 core 185 Sqmm XLPE Cable as per requirements. Make- Raychem, 3M, Denson, Cabseal or similar. | — | — | — | 90,726 | |
| — | 10.00 | — | — | ||
| Shifting, carrying, transportation, installation, testing and commissioning of DG set of Capacity 500/320/125/110/ 100/82.5/40 KVA from old location to new location over BKN Div. including shifting of AMF Control panel, batteries, battery chargers, cabling, trenching, connection to panel and c/c foundation for panels if required. With including all necessary accessories for carried out the work etc. (Cable will be supplied by railway) | — | — | — | 1,21,430 | |
| — | 550.00 | — | — | ||
| Supply of Battery-Enabled Emergency LED tube light fitting, 18-20 W, batten type, 4- feet long, complete with in-built Li-ion battery, providing minimum 04 hours backup at full load, including all accessories as per specifications. Make- Orient, Crompton, Phillips, Surya, Havells, Jaguar Halonix, Bajaj, Wipro and Eveready with warranty of 02 years. | — | — | — | 4,67,500 | |
| — | 550.00 | — | — | ||
| Fixing of Emergency LED four feet fitting with all accessories complete in all respect as per requirements. | — | — | — | 16,500 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing and commissioning of 100 kVAR Automatic power factor correction control panel with shunt capacitors as per technical specification. It includes panel box, MCCB, APFC relay, contractor, MPP type capacitor, MCB, wiring accessories etc. complete in all respect. | — | — | — | 4,90,828 | |
| — | 4.00 | — | — | ||
| Supply, install, testing & commissioning of LT panel with 2X800 Amp ACB as incomer & 4X400 Amp, 4-Pole MCCB, 2X250 Amp, 4 pole MCCB as outgoing with suitable capacity CT, Digital Ammeter, Voltmeter, Energy meter & selector switches as per specification. | — | — | — | 17,98,596 | |
| — | 1.00 | — | — | ||
| Design, manufacturing, supply, testing, erection and commissioning of indoor LT panel, medium voltage outdoor type consisting of - (a) Incoming 2 x 630 amps.4 pole MCCB with microprocessor release having integral overload, short circuit, earth fault and neutral protection and breaking cap 70 kA (Ics = 100% Icu). (b) Outgoing 2 x 250 amps. 2 x 200 amps. 4 x 125 amps and 7 x 100 amps. 4 pole MCCB with adjustable overload and adjustable short circuit trip unit and breaking cap. 50 kA (Ics = 100% Icu). (c) 1 x 630 amps. 4 pole Switch Disconnector unit as bus-coupler. (d) 1 x 315 amps. 4 pole manual on load change over switch. Work includes formation of foundation for panel with suitable trench up to the satisfaction of the site engineer and as per technical specification. | — | — | — | 6,13,040 | |
| — | 7.00 | — | — | ||
| Design, supply, fixing & commissioning of LT panel made by 2 mm CRCA sheet with 1 no. Incomer 250A MCCB, 36kA and Outgoing - 2 no. 4 pole MCCB 125A,16kA.,2 nos. 4 pole MCCB 63A,16kA and 2 nos. 4 pole MCCB 40A,16kA. All MCCB should be adjustable over load 80% to 100% & Adjustable short circuit, Ics = 100% Ics with meter & indication LED, copper bus bar etc. with foundation as per spec. | — | — | — | 8,17,404 | |
| — | 2300.00 | — | — | ||
| Supply & fixing of M.S.Jali 1" x 1" welded on MS angle frame 30 x 30 x 3mm which is fixed on base angle frame on 50 x 50 x 6mm and 40 x6 mm MS flat in center to support the jali. The whole structure with two nos. of key locks & 2 nos. hinges including the framed jali painted with one coat of red oxide and two coats of enamel paint to provide protection of electrical equipment. Providing roofing on rail / iron structure by MS / GI sheets with support of 50 x 50 x 6 mm angle with all accessories, etc. as per requirement. | — | — | — | 1,58,700 | |
| — | 8500.00 | — | — | ||
| — | — | — | 1,78,500 | ||
| — | : - Laying, be supplied | testing, commissioning tray etc. with complete by Rly. From main depot. | of LT cable of cable | ||
| — | 8200.00 | — | — | ||
| Digging and filling of trench size 0.4 x 0.8 mtr as per spec. (trench work may be on kuchha/ pucca land and all type of soil as per site requirement and without protective layer of brick) Surface of trench shall be made good in all respect and satisfaction of site engineer. | — | — | — | 3,11,600 | |
| — | 800.00 | — | — | ||
| Digging and filling of trench size 0.4 x 1.2 mtr as per spec. (trench work may be on kuchha/pucca land and all type of soil as per site requirement and without protective layer of brick) Surface of trench shall be made good in all respect and satisfaction of site engineer. | — | — | — | 41,600 | |
| — | 3000.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 50 mm dia, wall thickness 3 mm, PN 6, PE 80 as per requirement. | — | — | — | 1,89,000 | |
| — | 3000.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 50 mm dia, wall thickness 3 mm, under the road. The work involves laying of HDPE pipe along with transportation | — | — | — | 24,000 | |
| — | 2800.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 75/80 mm dia, PN 6, PE 80 as per requirement. | — | — | — | 2,43,600 | |
| — | 2800.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 75/80 mm dia, under the road. The work involves laying of HDPE pipe with transportation. | — | — | — | 33,600 | |
| — | 2200.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 110 mm dia, PN-6, PE-80, as per requirement. | — | — | — | 7,52,400 | |
| — | 2200.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 110 mm dia, PN-6, PE-80, under the road. The work involves laying of HDPE pipe with transportation. | — | — | — | 28,600 | |
| — | 500.00 | — | — | ||
| Drilling of horizontal bore below Track/Road by pushing method (trenchless technology) for laying of RCC/HDPE/DWC pipe of various sizes up to 200 mm dia. in presence of Railway representative taking all necessary safety precautions related track and movement of trains. Horizontal boring will be done at minimum 1.5 Mtr. Below from ground level at railway track portion. | — | — | — | 5,89,000 | |
| — | 25.00 | — | — | ||
| Supply and providing copper plate earthing 4.0 m deep size 600x600x3mm with 3.5m long G.I."B" class pipe 38 mm for pouring water with 50 Kg charcoal and 10Kg salt including RCC/masonry earth enclosure with pull out handle and 25x3 mm copper flat earth strip 4.0 mtrs long from earth pit bottom riveted to earth top. The earth value to be measured and marked on earth pit and as per specification attached. | — | — | — | 2,12,900 | |
| — | 250.00 | — | — | ||
| Supply, laying, connecting and testing of copper flat size 25 x 3 mm for connecting earth with equipment. | — | — | — | 1,03,000 | |
| — | 10.00 | — | — | ||
| Supply of unit maintenance free earth material as per RDSO Specs. No RDSO/PE/SPEC/PS/0/0109 (REV.0) 2008 or Latest. | — | — | — | 89,810 | |
| — | 10.00 | — | — | ||
| Installation of unit maintenance RDSO/PE/SPEC/PS/0/0109 (REV.0) 2008 or Latest. | — | — | — | 37,830 | |
| — | — | — | RDSO | ||
| — | — | — | Specs. | ||
| — | 50.00 | — | — | ||
| SITC of 4 meter length B Class 50 mm dia GI pipe earth station with digging pit & refilling with charcoal & salt and as per specification. | — | — | — | 67,300 | |
| — | 50.00 | — | — | ||
| Construction, supply and fixing of earth pit CC furnished chamber 300 x 300 x 250 mm, 50 mm thick with CI / RCC earth pit cover 300 x 300 x 25 mm with lifting hooked in center as per site requirement. | — | — | — | 29,450 | |
| — | 280.00 | — | — | ||
| Supply, laying and fixing of 25 x 5 mm GI earth strip at 0.5 meter below ground level or on walls/poles / along pipes etc., including connection / termination with GI nut, bolt, washer etc. as required (jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50 mm). Note:- Suitable GI saddles with screws shall be provided to secure earth strips run on walls /floors etc. | — | — | — | 41,720 | |
| — | 284.00 | — | — | ||
| Supply & providing of cable marker. The cable marker shall be made of MS Sheet 1.5mm thick size 150X100mm welded with 12mm dia MS rod 85 cm long. The lower end of rod should be turned in hooks shape and attached with the cable at the time of laying. | — | — | — | 46,008 | |
| — | 20.00 | — | — | ||
| SITC of Rubber Mat nonstick type suitable for 11kV AC Supply of size: 2000x1000x25mm as per requirements. | — | — | — | 20,520 | |
| — | 20.00 | — | — | ||
| Supplying & erection of shock Restoration Chart in glass frame as per site requirements. | — | — | — | 1,780 | |
| — | 10.00 | — | — | ||
| Supply & Fixing ISI marked (IS:15683 ) Portable Fire Extinguisher, CO2 type flat base including valve, discharge hose of not less than 10mm dia, min.600mm long & complete in all respects including initial fill with CO2 gas confirming to IS:307 of 1966 filled to a filling ratio of not more than 0.667 and wall suspension bracket capacity of 4.5 kg capacity. | — | — | — | 74,690 | |
| — | 4.00 | — | — | ||
| Supplying and Fixing of fire bucket stand made out of MS angle with one coat of primer and two coat of enamel paint of approved shade including platform and associated civil works each stand should have four nos fire buckets of 24 gauge galvanized steel sheet, standard 9 liter capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters "Fire" in black and gold at approved location as per direction of Engineer in charge. | — | — | — | 15,312 | |
| — | 20.00 | — | — | ||
| Supply and fixing of junction box size 390x305x170mm comprising of SMP/FRP material with rubber gasket, padlock arrangement, zinc passivated earth bolt, etc. similar to Sintex model no. GSJB 3525 or similar with 4 no. aluminium busbar cap 200 Amp., suitable for 415 volt supply requirement. The box shall be fixed robustly with clamps at pole/ wall as per requirement. All the material should be of good quality and as per tech. spec. | — | — | — | 40,560 | |
| — | 3.00 | — | — | ||
| Supply, fixing, testing and commissioning of fabricated feeder pillar distribution box made of MS sheet 1.6 mm thick size 600mmX300mmX600mm with suitable MS stand copper bus bar of 200 Amp. Capacity and 2X63 Amp MCB four poles as per technical specification. | — | — | — | 17,349 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and commissioning of ON LOAD changeover switch 630Amp in steel sheet enclosure, confirms to IS/IEC 60947-3 latest of reputed make. | — | — | — | 49,422 | |
| — | 400.00 | — | — | ||
| Lying of Spun / MS / GI / HDPE pipe up to 200 mm by push through method in Railway yard / below track / Road. | — | — | — | 1,77,200 | |
| — | 500.00 | — | — | ||
| Supplying and drawing FR PVC insulated & unsheathed flexible 3 Core X 1.5sqmm PVC unarmoured copper cable ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. | — | — | — | 25,500 | |
| — | 12.00 | — | — | ||
| Supply, laying and fixing of GI pipe medium "B" class (Blue) confirming to IS 1239 part-I for passing incoming and outgoing cable from ground through it size 100 mm dia. Pipe should be of reputed make. | — | — | — | 7,140 | |
| — | 24.00 | — | — | ||
| Supply, laying and fixing of GI pipe medium "B" class (Blue) confirming to IS 1239 part-I for passing incoming and outgoing cable from ground through it size 50 mm dia. Pipe should be of reputed make. | — | — | — | 4,512 | |
| — | 18.00 | — | — | ||
| Supply, laying and fixing of GI pipe medium "B" class (Blue) confirming to IS 1239 part-I for passing incoming and outgoing cable from ground through it size 38 mm dia. Pipe should be of reputed make. | — | — | — | 2,250 | |
| — | 10.00 | — | — | ||
| Supply, fabricate & fixing of compete street light control box with MCB, toggle switch, contactor and timer. Box: CRCA sheet of size 300 x 300 x 150 mm IP-65 protection with powder coated, foamed in PU gasket, Gland plate, cam locking arrangement, wall/Rail as per site requirement mounting bracket. Time switch: FM/1, QT, One Daily Dial, 240V AC Similar to Cat.no. J648B1 of L&T(GIC) make. Contractor: ML-1.5, 25amps, AC-1 rating, coil voltage 240V, 50 Hz MCB: Single pole, "B" series, Conforms to IS- 8828:1996 or latest, Capacity - 6-32 amps (AC), Phase/Voltage - 1Ph / 240 V, Frequency - 50 Hz, Breaking capacity - 10kA. Toggle Switch: One/Two way toggle switch suitable for by pass the automation of lighting. | — | — | — | 74,420 | |
| — | 6.00 | — | — | ||
| Supply, install, test & commissioning of MCCB 4P, 400A, 50kA adjustable thermal adjustable magnetic trip unit. | — | — | — | 1,69,362 | |
| — | 12.00 | — | — | ||
| Supply, install, test & commissioning of MCCB 4P, 250A, 36kA adjustable thermal adjustable magnetic trip unit. | — | — | — | 1,66,788 | |
| — | 10.00 | — | — | ||
| Supply, install, test & commissioning of MCCB 4P, 160A, 36kA adjustable thermal adjustable magnetic trip unit. | — | — | — | 1,33,580 | |
| — | 15.00 | — | — | ||
| Supply, install, test & commissioning of MCCB 4P, 125A, 16 kA adjustable thermal adjustable magnetic trip unit. | — | — | — | 89,715 | |
| — | 15.00 | — | — | ||
| Supply, install, test & commissioning of MCCB 4P, 100A, 16kA adjustable thermal adjustable magnetic trip unit. | — | — | — | 62,670 | |
| — | 15.00 | — | — | ||
| Supply, install, test & commissioning of MCCB 4P, 63 A, 16kA adjustable thermal adjustable magnetic trip unit. | — | — | — | 57,165 | |
| — | 950.00 | — | — | ||
| Supply of material and laying of perforated GI cable tray of size 100mm X 50 mm size & 2mm thick, with cover and all fixing Arrangements as per specification and as per site requirement | — | — | — | 3,61,950 | |
| — | 1150.00 | — | — | ||
| Supply of material and laying of perforated GI cable tray of size 200mm X 50 mm size & 2mm thick, with cover and all fixing Arrangements as per specification and as per site requirement. | — | — | — | 5,76,150 | |
| — | 800.00 | — | — | ||
| Supply of material and laying of perforated GI cable tray of size 300mm X 50 mm size & 2mm thick, with cover and all fixing Arrangements as per specification and as per site requirement. | — | — | — | 9,20,800 | |
| — | Breakup | for details. | — | ||
| Repairing and overhauling of 750 KVA Transformer | — | — | — | 1,72,574 | |
| — | Breakup | for details. | — | ||
| Repairing and overhauling of 500 KVA Transformer | — | — | — | 2,67,564 | |
| — | Breakup | for details. | — | ||
| Repairing and overhauling of 250 KVA Transformer | — | — | — | 2,67,506 | |
| — | Breakup | for details. | — | ||
| Repairing and overhauling of 160 KVA Transformer | — | — | — | 1,59,324 | |
| — | Breakup | for details. | — | ||
| Repairing and overhauling of 100 KVA Transformer. | — | — | — | 1,51,580 | |
| — | 12.00 | — | — | ||
| Servicing /Maintenance of 11KV VCB's with general servicing, cleaning, oiling, greasing of mechanism & checking/testing the functioning of Closing & tripping mechanism ckt. With repairing /re-adjustment of Racking/out shaft assembly & all Closing ckt. If any defective or missing like screw, washer, nutbolt, dowel tension pin, split pin , lug, connectors and small tightness item to be replaced by firm free of cost, interlocking adjustment for proper functioning of the same at the healthiness at site. | — | — | — | 85,248 | |
| — | 25.00 | — | — | ||
| Servicing and repairing of ACB's Capacity 800 - 2000 A, 415V, 50Hz with general servicing, cleaning, oiling, greasing of mechanism & checking/testing the functioning of Closing & tripping mechanism ckt. With repairing /re-adjustment as per requirement. If any defective or missing item like screw, washer, nutbolt, dowel tension pin, split pin , lug, connectors and small tightness item to be replaced by firm free of cost, interlocking adjustment for proper functioning of the same at the healthiness at site. | — | — | — | 1,03,425 | |
| — | Breakup | for details. | — | ||
| Servicing and repairing of ACB's Capacity 800- 2000 A capacity 415V, 50Hz (Material required for maintenance). | — | — | — | 54,010 | |
| — | 5.00 | — | — | ||
| Supply & testing of 3 phase, BEE 5 star rated Submersible pump capacity 10 HP suitable for bore 150mm, discharge 140 to 160 LPM. Head 200 to 220 Mtr, BEE approved. Make: KSB / Duke / CRI / Sabar / CG/ Kirloskar. | — | — | — | 3,71,070 | |
| — | 4.00 | — | — | ||
| Supply & testing of 3 phase, BEE 5 star Submersible pump capacity 20 HP suitable for bore 150mm, discharge 250 to 270 LPM. Head 160 to 180 Mtr, BEE approved. Make: KSB / Duke / CRI / Sabar / CG/ Kirloskar. | — | — | — | 3,98,836 | |
| — | 48.00 | — | — | ||
| Supply, erection, testing and commissioning of integrated Solar street light arrangements with the following :- 1.Light poles of 6m height made by GI pipe of 65 mm Dia 2. IP 65 or better, 25-30 Watt LED streetlight. 3. 12.8V, 30 AH, Lithium Ferro phosphate battery. 4. Greater than 75Wp Solar Mono panel. 5. Timer arrangements. | — | — | — | 10,58,400 | |
| — | 6.00 | — | — | ||
| Design, manufacturing, supply, testing, erection and commissioning of LT panel, medium voltage. (a) Incoming 1 x 400 amps.4 pole MCCB with adj .overload and adj. short circuit trip unit and breaking cap 50 kA (Ics = 100% Icu). (b) Outgoing 2 x 200 and 2 x 160 amps. 4 pole MCCB with adjustable overload and adj. short circuit trip unit and 2 x 125 amps. 4 pole MCCB with adjustable overload and fixed short circuit trip unit breaking cap. 36kA (Ics = 100% Icu). As per technical specification. | — | — | — | 8,76,420 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing and commissioning of ON LOAD changeover switch of 250Amp rating with suitable enclosure, Conforms to IS/IEC 60947-3 latest of reputed make. | — | — | — | 75,664 | |
| — | 6.00 | — | — | ||
| Dismantling of existing lattice tower of 20/30 meter height including all accessories, complete with skilled labour, required tools & tackles, cranes/derricks etc., safety equipment, barricading and all safety precautions. The dismantled material shall be transported and returned to concerned SSE/store or as directed by the site engineer as per site requirements. | — | — | — | 92,550 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .