Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹41.9 LAccepted-AOC 0 GANGARAM DHARMKANTA TRUCK UNION JIROTA KALAN DAUSA DAUSA RAJASTHAN 303303 | DAUSA | RAJASTHAN | 303303 | L-1 | Accepted-AOC ACCEPTED | |
| 2 | L-2₹43.0 L+₹1.1 L (2.74%)Rejected-Finance 51 1 FULBAGAN ROAD BAGHAJATIN KOLKATA 700086 WEST BENGAL | KOLKATA | WEST BENGAL | 700086 | L-2 | Rejected-Finance Due to higher bid value | |
| 3 | L-3₹43.7 L+₹1.8 L (4.39%)Rejected-Finance 63E SASHAN KALITALA ROAD KOLKATA 700 008 | KOLKATA | WEST BENGAL | 700008 | L-3 | Rejected-Finance Due to higher bid value | |
| 4 | L-4₹44.2 L+₹2.3 L (5.45%)Rejected-Finance | L-4 | Rejected-Finance Due to higher bid value | |
| 5 | L-5₹44.2 L+₹2.3 L (5.54%)Rejected-Finance | L-5 | Rejected-Finance Due to higher bid value |
Tender Value
₹42.0 L
EMD Value
₹83,100
Closing Date
15 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Kolkata
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
PERIODICAL CLEANING OF UNDER GROUND STORAGE TANK OVER HEADS STORAGE TANK AND PVC WATER STORAGE TANK AND PVC WATER STORAGE TANK AT CH (EC) AND II LINE AREA UNDER GE ALIPORE KOLKATA
2024_MES_661036_1
GE/ALP (8340B) KOLKATA OF 2024-25
Open Tender
Civil Works - Water Works
Item Rate
180 days
GE (ALIPORE) KOLKATA
Class D and Category c (vii)
9 documents required · 9 mandatory
₹500
Garrison Engineer, Alipore
₹83,100
Yes
GE (ALIPORE) KOLKATA
24 Oct 2024
21 Jun 2024
22 Jul 2024
21 Jun 2024
15 Jul 2024
8 Jul 2024
21 Jun 2024 - 28 Jun 2024
29 Jun 2024
Amount
M&L for Periodical cleaning of underground sump , descaling/desilting internal surface and floor wih wire brush and removing/ lifting the semi-solid/mud/sludge/algea from in sode the tank and wash with bleaching powder and fresh water two times and dewatering out of the sump, removing the entire deposited / sludge, mud, silt etc, scrapping the internal wall / floor with wire brush , and removing the same at a distance n.exc 50m from site where directed, opening the blocked holes etc complete all as specified and as directed including writing ,capacity of tank with synthetic enamelled paint for the following capacity of tank. Note- (i) The notice for the interruption of water will be intimated to the department in advance (ii) Material and labour for removal of semi solid/ solid sludge exteracted during cleaning and their disposal to suitable site are deemed to be included in quoted rate.
RCC under ground sump 150000 gallon capacity Note: Consumption of bleaching powder for cleaning of tank shall not be less than 80 Kg.
RCC under ground sump 100000 gallon capacity Note: Consumption of bleaching powder for cleaning of tank shall not be less than 80 Kg.
RCC under ground sump 50000 gallon capacity Note: Consumption of bleaching powder for cleaning of tank shall not be less than 30 Kg.
RCC under ground sump 25000 gallon capacity Note: Consumption of bleaching powder for cleaning of tank shall not be less than 20 Kg.
RCC under ground sump 6000 liter capacity Note: Consumption of bleaching powder for cleaning of tank shall not be less than 20 Kg.
M&L for quarterly cleaning of underground sump , descaling/desilting internal surface and floor wih wire brush and removing/ lifting the semi-solid/mud/sludge/algea from in sode the tank and wash with bleaching powder and fresh water two times and dewatering out of the sump, removing the entire deposited / sludge, mud, silt etc, scrapping the internal wall / floor with wire brush , and removing the same at a distance n.exc 50m from site where directed, opening the blocked holes etc complete all as specified and as directed including writing ,capacity of tank with synthetic enamelled paint for the following capacity of tank. Note- (i) The notice for the interruption of water will be intimated to the department in advance (ii) Material and labour for removal of semi solid/ solid sludge exteracted during cleaning and their disposal to suitable site are deemed to be included in quoted rate.
Sheet metal over head tank on the roof of multistories bldgs, capacity 60000 Ltrs Note: Consumption of bleaching powder for cleaning of tank shall not be less than 5 Kg.
RCC over head tank on the roof of multistories bldgs, capacity 10000 Ltrs Note: Consumption of bleaching powder for cleaning of tank shall not be less than 5 Kg.
RCC over head tank on the roof of multistories bldgs, capacity 5000 Ltrs Note: Consumption of bleaching powder for cleaning of tank shall not be less than 5 Kg.
Material and labour for scrapping quarterly with fibre bursh /wire brush to remove all dirts and removing sediments and through cleaning of rotational moulded polythene water storage tank with fresh water and then with dilute bleaching powder solution and fresh water for following capacity of tank :-
PVC over head tank on the roof of multistories bldgs, capacity 10000 Ltrs Note: Consumption of bleaching powder for cleaning of tank shall not be less than 5 Kg.
PVC over head tank on the roof of multistoried bldg, capacity 5000 ltrs Note: Consumption of bleaching powder for cleaning of tank shall not be less than 2.5 Kg.
PVC over head tank on the roof of multistoried bldg, capacity 2000 ltrs Note: Consumption of bleaching powder for cleaning of tank shall not be less than 1 Kg.
PVC over head tank on the roof of multistoried bldg, capacity 1500 ltrs Note: Consumption of bleaching powder for cleaning of tank shall not be less than 0.75 Kg.
PVC over head tank on the roof of multistoried bldg, capacity 1000 ltrs Note: Consumption of bleaching powder for cleaning of tank shall not be less than 0.5 Kg.
PVC over head tank on the roof of multistoried bldg, capacity 500 ltrs Note: Consumption of bleaching powder for cleaning of tank shall not be lesser than 0.5 Kg.
Material and labour for bailing out dirty water clogging material from under ground sump of capacity 90,000.00 gallons (having two nos partition of 45,000 gallons each) at main sewage and cleaning by the solution of bleaching powder and disposal of sludge/water clogging materials etc out side the Command Hospital Complex complete all as specified and as directed. Note: Consumption of bleaching powder for cleaning of tank shall not be less than 60 Kg.
All as per item No 18 here-in-before but at MAP PH-II sewage of tank Capacity 5600 gallons (having 2 no. of partition 2800 gallon each) complete all as specified and as directed. Note: Consumption of bleaching powder for cleaning of tank shall not be less than 5 Kg.
Material and labour for draing out dirty water clogging material from under ground sump of capacity 25,000.00 gallons (having two nos partition of 12,500 gallons each) at basement sewage and cleaning by the solution of bleaching powder and disposal of sludge/water clogging materials etc out side the Command Hospital Complex complete all as specified and as directed. Note: (i) Tank shall be cleaned quarterly. (ii) Consumption of bleaching powder for cleaning of tank shall not be less than 20 Kg.
All as per item No 20 here-in-before but laundary plat, sewage of tank Capacity 4,000 gallons (having 2 no.partition of 2000 gallon each) complete all as specified and as directed. Note: Consumption of bleaching powder for cleaning of tank shall not be less than 5 Kg.
All as per item No 20 here-in-before but at AC-2 Complex, sewage of tank Capacity 10,000 gallons (having 2 no. partition of 5000 gallon each) complete all as specified and as directed. Note: Consumption of bleaching powder for cleaning of tank shall not be less than 5 Kg.
Material and labour for one coat of cement base paint on external surface of RCC tank including preparation of old surfaces.
Collecting the sample of water from different point and testing of water for iron, PH value, Hardness, trubidity, chloride, fluoride and submitting the test report from reputed laboratory as directed. Note : Sampling and Testing shall be carried out quarterly as directed.
Carrying out bacteriological test including arsenic test for water sample collected from different installation quarterly as specified and directed
Supply and fix as in repair following GI fittings (for inlet/outlet/washout connection) including necessary making good the existing work to match the surface for RCC/PVC OH tanks :-
Long Screw 1"dia x 6" long
Nipple 1" dia x 4" long
GI Plug80 mm
GI Plug 20/15 mm
GI plug 50 /40 mm mm
50 mm dia PVC ball valve high pressure with polythene float complete after taking down old unserviceable valve.
40 mm dia PVC ball valve high pressure with polythene float complete after taking down old unserviceable valve
25 mm dia PVC ball valve high pressure with polythene float complete after taking down old unserviceable valve.
20 mm dia PVC ball valve high pressure with polythene float complete after taking down old unserviceable valve.
15 mm dia PVC ball valve high pressure with polythene float complete after taking down old unserviceable valve.
PVC tank cover complete 500 ltr.
PVC tank cover for 1000 ltr capacity.
PVC tank cover for 1500 ltr capacity.
PVC tank cover for 2000 ltr capacity.
PVC tank cover for 5000 ltr capacity.
Taking up steel water tubing and connection from trench/wall/floor , bore of pipe 80 mm
All as per item No 32 here-in-before but 50 mm dia
All as per item No 32 here-in-before but 40 mm dia
M & L for steel water tubing medium grade including all fittings fixed complte laid in wall/ceiling/floor of 80 mm dia all as specified and directed.
All as per item No 35 here-in-before but 50 mm dia but laid in wall/ceiling/floor
All as per item No 35 here-in-before but 40 mm dia but laid in wall/ceiling/floor
S & F for Gun metal gate valve with iron wheel head, screwed down iron pipe of 50 mm bore after taking down old unserviceable valve.
S & F for Gun metal gate valve with iron wheel head, screwed down iron pipe of 40 mm bore after taking down old unserviceable valve
M & L for 80 mm dia butter fly valve made of iron including all accessories after taking down old unserviceable valve
S&F, Triple layer ,polyethylenen water storage tanks conforming to IS (embossed) (cylindrical vertical with closed top) hoisted and fixed in position all as specified (capacity-1000 ltr).
S&F ,Triple layer ,polyethylenen water storage tanks conforming to IS (embossed) (cylindrical vertical with closed top) hoisted and fixed in position all as specified (capacity-2000 ltr).
Material and labour for Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc of 40 mm dia.all as specified and directed.
NUPUR CONSTRUCTION (BID ID -3057960)
DK Contractor (BID ID -3060940)
SEN ELECTRIC WORKS (BID ID -3058879)
TOTCO (BID ID -3057385)
ESS PEE UDYOG (BID ID -3059926)
NESAIL CORPORATION (BID ID -3056740)
RADHA ENTERPRISE (BID ID -3054399)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .