Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹15.8 L+₹5,413 (0.34%)Rejected-Finance | L2 | Rejected-Finance Being higher bid Bidder | |
| 3 | Rejected-Technical 687 ARYA NAGAR POWAYAN ROAD SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | - | Rejected-Technical Not approved due to not enlisted in eligible category b(ii). | |
| 4 | Rejected-Technical 578 AVAS VIKAS JANAKPURI B IZATNAGAR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | - | Rejected-Technical Not approved due to not enlisted in eligible category b(ii). |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
24 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bareilly
HEADQUARTERS, COMMANDER WORKS ENGINEER, MILITARY ENGINEER SERVICES, STATION ROAD, BAREILLY CANTT, PIN 243001
CA NO CWE BLY/GE (E)/13 OF 2023-24 REPAIR/ REPLACEMENT AND MAINT OF EXTERNAL ELECT, REPAIRS TO TRANSFORMER ALONG WITH ALLIED SERVICES FOR HT DISTRIBUTION SYSTEM AT MIL STN SHAHJAHANPUR UNDER GE (EAST) BAREILLY
2023_MES_598613_1
8200/B/755/E8
Open Tender
Civil Works
Item Rate
180 days
Shahjahanpur
Class E Category b(ii) For Unenlisted Contractor - Meeting enlistment criteria of MES with regard to having satisfactory completed requisite value of work, Annual turnover, working capital , etc as mentioned in NIT
6 documents required · 6 mandatory
₹500
GE ( E ) Bareilly
₹50,000
Yes
24 Jul 2023
26 May 2023
1 Jul 2023
26 May 2023
24 Jun 2023
10 Jun 2023
Amount
Taking down Maintenance complete overhauling of 11 KV VCB of existing make/ type/mode/capacity including disassembling of operating mechanism parts well cleaning with petrol and CRC-226 and replacing unserviceable spare parts reassembling of parts including well cleaning the complete panel board,main busbar, decarbonizing all joints busbar CTS,PTS, spouts metal parts and making VCB perfect operating in manual and electric mode and calibration & checking of tripping system of 11 KV circuit breaker through IDMT over current and earth fault relay at plug setting infeeted inservice by primary current injection method to ensure proper function of trip coil control circuit etc. during fault condition setting by expert complete all as specified and directed.Note:- Spare parts required to make VCB functional will be measured and paid separately under respective items.
S&F in replacement Current transformer (CT) of ratio 100-50/5-5, IL 12/28/75/KVP STC 13-1KA for 1 second confirming to IS-2705, IEC-60044 complete all as specified and as directed.
S&F in replacement Toggle switch assembly complete all as specified and directed.
S&F in repair strip type heater 40/60 watt sutable for existing VCBs complete all as specified and directed.
Replacement of 11 KV HT PT housing spout (Male/Female) complete all as specified and directed.
Replacement of bearing of 11 KV complete all as specified and directed.
S&F in replacement of unsv 3 phase over current, earth fault relay of CT rating 1A to 5A model MC-31A, Aux supply volt-20-110 volt AC/DC out put complete all as specified and directed.
Testing of dielectric strength of transformer's oil installed at various locations by taking samples of oil from transformers for testing in the laborotary and submit detailed report of electrical parameters of oil testing complete all as specified and directed. Note : Testing charges shall be born by the Contractor.
M&L for dehydration of transformer oil with mobile transformer filteration plant at site with all required accessories connected to transformer and carrying out filteration of transformer oil for the desired dielectric strength. ie not less than 60 KV at 2.5 mm gap complete all as specified and as directed. Note : Test certificate shall be submitted before and after filteration for dielectric strength.
Supply & filling for topping new transformer oil in the transformer after dehydration with dehydration machine to achieve dielectric strengh of oil 60 KV at 2.5 mm gap complte all as specified and directed. .
Servicing of existing transformer after disconnecting of all incoming and outgoing electrical connections including opening of cover and tightening of all bushes and studs of transformer and top up of transformer oil including replacement of defective/unserviceable part and reconnection of all incoming and outgoing electrical connections complete for 50 to 400 KVA capacity transformer complete all as specified and directed. Oil and part shall be measured and paid separately).
Supply and fixing in replacement HV bushing with metal parts 11 KV grade brass spindle and 04 Nos Hexagonal nuts for 50 KVA to 400 KVA capacity transformer completeall as specified and directed.
Supply and fixing in replacement LV bushing with metal parts 415 volt grade brass spindle and 04 Nos Hexagonal nuts for 50 KVA to 400 KVA capacity transformer completeall as specified and directed.
Supply & Fixing cork sheet for transformer top cover complete all as specified and directed.
M&L for replacing existing unservicable silica gel with new crystal clean silica gel for the breathers of transformers capacity 50 to 400 KVA complete all as specified and directed.
Supply and replacement of unservicable (broken / cracked) breathers assy complete of various transformers suitable for pipe entry of 20/25 mm dia complete all as specified and directed. (as per old sample)
M&L for transformer oil level indicator assembly of various transformers from position for making visibility of oil level after draining transformer oil by lowering oil level inconservator , with and including cleaning, painting , changing of gasket and acrylic sheet, fixing back in position complete all as specified and as directed.
M & L for replacing unservicable drain valve suitable size of various transformers complete all as specified and as directed.
Supply and fix in replacement on load tap changer switch suitable for various transformers complete with spindle etc all as specified and directed.
Supply and fix in replacement explosive vent diaphragm complete all as specified and directed.
Disconnecting and taking down of defected transformer of any size from sub stn, loading the same in vehicle to factory for repair and of repairable transformers fixing at existing location complete all as specified and directed.
Supply and fix in replacement oil temperature guage complete all as specified and directed.
Disconnecting and taking down of LT cable from LT Panels, from both ends of LT panel at various places of outdoor/indoor type and re-fixing after segregate/rearrange the cables, lugs, cable jointing kit and repair of door of MS sheet 1.6 mm thick, alongwith door hinges, nut bolt and washers of LT Panel door complete all as specified and directed.
Supply and fixing HV and LV leg coils made of copper winding wire of suitable size according to the capacity of transformer complete all as specified and directed.
M&L painting of transformer 11KV/415 volt (50 KVA to 400 KVA) outdoor/Indoor/Pole mounting including cleaning, scraping of exposed surfaces and painting two coat of synthetic enamel paint over a coat of primer with shade as approved including writing MES Nos and machiner No with black paint, size of letter shall be 15mm wide and 50mm high complete all as specified and directed.
Supply and laying synthetic insulating mat 2.5 mm thick of size 1 Mtr x 2 Mtr ISI Marked complete all as specified and directed.
M&L for removing entire existing graded gravel/Coarse aggregate 63mm to 40mm from Sub station and 4 pole/2pole structure and cleaning of area and aggregate and spreading and levelling the same in layers complete all as specified and directed.
Surface dressing not exc 15 cm deep including cutting and cleaning, away grass, bushes,small plants, vegetation saplings shurbs, bush wood under growth roots ,trees not exc 30 cms girth and removing the excavated material and rubbish to a distance not exc 1500 Mtrs outside the periphery of area under clearance (one or more times for same place) complete all as specified and directed.
Trimming of trees all as along the HT line in such a way that there is clear distance of 3 meter between tree and electric line. The work will be executed to the entire satisfaction irrespective of the size of the tree branches etc complete all as specified and directed. Note : (i) Tree branches etc will be left as idle the wood belongs to Cantt board/DEO and they will be responsible for the wood. (ii) Contractor will employ sufficient labour to complete the full one job with in about 15 days. (iii) Contractor will responsible for any type of accident while trimming the trees. (iv) Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply, however full assistance will be provided by MES staff.
M&L for preparation old (exposed) painted surfaces of existing HT steel tubular pole, struts including cross arms, clamps etc complete and applying two coats of aluminium paint and plainting to band/strip with two coats of synthetic enamel paint including numbering of poles at a height of 1.5 mtr above ground level as per existing having 15mm width and 50mm bold letter complete all as specified and directed.
Material and labour in replacement for GOD tripple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 Amps 11000 volt complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade for outdoor termination end heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured AI conductor cable of size 50 to 95 Sq mm complete all as specified and as directed.
Supply and fix cable jointing kit for 11 KV grade for outdoor termination end heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured AI conductor cable of size 120 to 185 Sq mm complete all as specified and as directed.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size but 120 sqmm to 185 sqmm complete all as specified and as directed.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size but 50 sqmm to 95 sqmm complete all as specified and as directed.
Dismantling of insulator of any type and size from existing poles after opening nuts, bolts and removing from site complete all as specified and directed.
Supply and fix Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type white brown or green single disc assembly for tension with tension clamps for working pressure 11000 Volts complete all as specified and as directed.
Supply and fix Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron wasers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed.
Supply and fix Loop type insulator, vitreous porcelain, white brown or green large size with overall dimensions 140mmx40mm, clearance of hole 25.5 mm complete all as specified and directed.
Taking down old ACSR conductor of any size and capacity complete all as specified and directed.
S&F in replacement of ACSR conductor for HT over head line Aluminium conductor steel reinforced size as per existing complete all as specified and directed.
Material and labour for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) earthed with aluminium conductor, 11000 volts grade cross secional area 95 Sqmm 3 core complete all as specified and as directed.
Material and labour for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) earthed with aluminium conductor, 11000 volts grade cross secional area 120 Sqmm 3 core complete all as specified and as directed.
Excavation in trenches not exc. 1.5 metre wide and not exc. 1.50 mtr depth for laying of underground cable, erection of poles etc. and getting out in soft/loose soil including separating serviceable bricks for re-use at site obtained during excavation complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removal of surplus soil not exc 50mtr distance and depositing complete all as specified and as directed.
M & L for dry screened river bed sand cushioning 8cm before laying the cable and 15cm after laying the cable and further hand punned to form a uniform all as complete all as specified and as directed.
M&L for laying bricks, sub class'B' for protection of cable, in trenches, laid in dry flat across the cable with length of whole bricks complete all as specified and directed.
M&L in replacement for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron earth strip 32X6mm by means of bolts nuts check-nuts and washers of galvanized iron or steel as shown in electrical plate No 5 of MES schedule Part-I connecting to earthing test point and testing on completion with including 15mm bore light grade GI protection pipe, RCC 1:2:4 type B1 20mm thick cover reinforced with 6mm thick dia MS bars 3 Nos both ways with lifting hook made out of 6mm dia MS bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, earthing lead from earth plate to eqipment to point (up to 7.5M long) common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed.
Supply & fixing in replacement of G.I Strip of size 32 x 6 mm as in earthing with all hardwares required complete to transformers situated at different locations complete all as specified and directed.
Maintenance of 2/4 pole structure by disconnecting all incoming and out going over head line conductor jumper joint and UG cable end terminal joint from GOD etc and rebinding/renewal of all joint with fresh joint, inserting PVC coloured sleaves over conductor including treatment of GOD contacts and ACSR conductor with conducting jelly complete all as specified and directed.
S&F in replacement Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo Amps for 11 KV complete all as specified and directed.
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm complete all as specified and directed.
M &L of hiring of cable fault locator machine for HT cables ,working voltage 11KV to find out the fault in underground trench at different location up to 500 RM after locate fault and jointing and testing the cable all as specified and directed. Note : (a) Excavation and earth work & joints will be paid and measured separately in relevant item (b) if the complaint not attended within one hour contractor shall be liable to pay a penalityof rs 1000/-per hour per complaint.
Taking down steel tubular poles in vertical position/as strut poles sewaged 410-SP-55, 11 Mtr long, complete all as specified and directed.
Supply and Fixing erecting in replacement steel tubular poles in vertical position/as strut poles sewaged 410-SP-55, 11 Mtr long, ISI marked complete with cast iron / M S base plate, finial taper plug, bolts, nuts washers and screws as required duly painted with two coats of aluminium paint over a coat of read oxide primer above ground level, internally and including Planting depth (externally) with two coats of bituminous paint and numbering of poles, black strips etc complete all as specified and directed.
Supply and fixing in replacement cross arms, bracings, supports, clamps, back plate fabricated from structural steel sections such as channels, angles, flat iron including 16mm dia bolts, nuts, washers, welding, bending, cold or hot drilling holes for bolts/insulators in any shape and size as directed and inclusive of one priming coat of red oxide zinc chrome, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
M&L PCC 1:4:8 type D 2 using 40mm graded stone aggregateas in foundation of poles etc complete all as specified and directed.
M&L PCC 1:2:4 type B 1 using 20mm graded stone aggregate as in benching / copping around poles including necessary form work complete all as specified and directed.
Supply and fixing in replacement guarding cradles, hexagonal rectangular, fabricated with galvanised steel wire 3.15mm or 4mm dia complete all as specified and directed.
M & L for boring under road for laying for UG cable including GI tubing light grade of size 100mm complete all as specified and directed.
S & F in replacement of GI tubing light grade 100 mm nominal bore for cable protection fixed with clamps of M.S. Flat iron 25x3mm, GI nuts, bolts and washers to poles/under floor/under roads/alongwith walls including two coats of aluminium paint over a coat of red oxide primer on clamps complete including taking up of old UNSV GI tubing complete all as specified and directed.
M& L for stay assembly complete with accessories diameter of stay rod in 20mm all as complete from pole complete all as specified and directed.
M& L for dismantling stay assembly from pole complete all as specified and directed.
S & F in repair galvanised steel stranded stay wire size 7/4 mm for stay assembly complete all as specified and directed.
Supply and fix cylindrical capacitors for following sizes as per existing capacitor bank panel including all fixing arrangements with proper fixing complete all as specified and directed.
Note : Tenderers may note that amount of credit Rs 77,970.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
M/S HINA ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .