Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.8 L+₹1.0 L (3.69%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹41.9 L+₹14.1 L (50.9%)Rejected-Finance OLD SABZI MANDI PATHANKOT M S NORTHERN INDIA CONSTRUCTION CO DHANGU ROAD VILLAGE TOWN PATHANKOT CITY PATHANKOT PATHANKOT PUNJAB 145001 INDIA | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹44.1 L+₹16.4 L (59.0%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹44.2 L+₹16.4 L (59.2%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
29 Feb 2024, 6:00 pmClosed
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
CRTN REPR OF LT PANEL UG CABLE LT POLE AND WINDOWS SPLIT AC CERTAIN REF AND AC ITEMS AND OTHER ALLIED WORKS AT DAMTAL KANDRORI KAUNTERPUR MIRTHAL AREA UNDER STN HQ KANDRORI GE S PATHANKOT
2024_MES_640619_1
GES/PKT/T-53/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹86,000
Yes
22 Jun 2024
3 Feb 2024
2 Mar 2024
3 Feb 2024
29 Feb 2024
19 Feb 2024
Amount
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays.
All as per above item but exceeding depth 1.5 mtr and n exceeding 3 mtrs
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009). Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Laying only old bricks retrieved from item No.8 of any size/type laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Removing existing 1100 volts grade, XLPE/PVC, armoured, electric power cables (heavy duty) with aluminium conductor of sizes 6 Sqmm 4 core to 16 Sqmm 4 core from trench/ duct/ pipe carefully for identifying the defects and relaying the same after rectification of defects complete all as directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 2 core.Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
Same as Item No.9 above but of size 16 x 04 core
Same as Item No.9 above but of size 25 Sqmm 4 core
Same as Item No.9 above but of size 35 Sqmm 3.5 core
Same as Item No.9 above but of size 50 Sqmm 3.5 core
Same as Item No.9 above but of size 70 Sqmm 3.5 core
Same as Item No.9 above but of size 95 Sqmm 3.5 core
Same as Item No.9 above but of size 120 Sqmm 3.5 core
S&F PVC insulated copper conductor cable 10 Sq mm x 3 core for main Panel to main switch/ starter, MCCB etc complete with thimbales of suitable size as required on site all including making connection all as specifed and directed.
Supply and Repair/Replacement of laying/jointing GI Pipe light grade 40mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed.
Supply and Repair/Replacement of laying/jointing GI Pipe light grade 80mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed.
M&L for Horizontal Boring/Cutting of Road/Foot Path for using through 40/80mm bore pipe for cable protection and finishing PCC after Boring/Cutting of road/Foot path, complete all as specified and as directed.
Supply and Repair/Replcement for weather proof flat twin core 6 sqmm multistrand aluminium conductor cable complete all as specified and directed by Engineer-in-Charge.
Supply and Repair/Replacement for weather proof flat twin core 10 sqmm multistrand aluminium conductor cable complete all as specified and directed by Engineer-in-Charge.
M&L for fault finding on LT/HT cables of any size and any length with fault detective machine by thumbing method/other suitable find out method with suitable high voltage and all as and directed by Engineer-in-charge.
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete all as specified and directed Engr-in-Charge.
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm complete all as specified and directed Engr-in-Charge.
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 10 sqmm to 16 sqmm complete all as specified and directed Engr-in-Charge.
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to150 sqmm complete all as specified and directed Engr-in-Charge.
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for INDOOR / OUTDOOR END TERMINATIONS heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 16 sqmm to 50 sqmm complete all as specified and directed Engr-in-Charge.
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for INDOOR / OUTDOOR END TERMINATIONS heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to150 sqmm complete all as specified and directed Engr-in-Charge.
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for INDOOR / OUTDOOR END TERMINATIONS heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete all as specified and directed Engr-in-Charge.
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note:a) The M/L for Items like lamp, electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately.
Supply only the following spares suitable for LED street/Flood light fittings of
Electronic driver potted type IP-65, suitable for 90 to 120 W LED light fitting
Electronic driver potted type IP-65, suitable for 70 to 80 W LED light fitting
Electronic driver potted type IP-65, suitable for 30 to 60 W LED light fitting
Surge protection device of capacity 10 KV suitable for LED light fitting
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 10000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 100 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED “inverter type bldg security light fittings with inbuilt battery backup for min 3 to 4 hrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4500 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 45 watt roadway lumanarie type with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED “inverter type bldg security light fittings with inbuilt battery backup for min 3 to 4 hrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 60 watt roadway lumanarie type with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED “inverter type bldg security light fittings with inbuilt battery backup for min 3 to 4 hrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 72 watt roadway lumanarie type with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 5000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 50 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 72 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 150 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Taking down old unserviceable street light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 15000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 90 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 20000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 200 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Dismantling old un-serviceable flood light fittings from any position exceeding 7.5 m height, Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 10000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 100 watt, with ingress protection IP 65 and surge protection device of 10 KV capacity etc incl necessary, angle iron supports , clamps etc complete and testing on completion all as specified and as directed
Supply & fix replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate,including all accessories prewired complete.Note :- (i) Minimum 2 years gaurntee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type. (iii) Power factor more than 0.9
Supply and Repair/Replacement of decorative gate light moon (opal) type made up of high grade unbreakeble polycarbonate material suitable for retrofit B22 base and fixing on existing 40/50 mm pole dia with 7 watt LED lamp complete all as specified and direcred by Engineer-in-Charge
Supply and Repair/Replacement of decorative gate light MUSHROOM (PRISMATIC) type made up of high grade unbreakeble polycarbonate material suitable for retrofit B22 base and fixing on existing 40/50 mm pole dia with 7 watt LED lamp complete all as specified and direcred by Engineer-in-Charge
Supply and Repair/Replacement of decorative gate light Lexo (Prismatic) made up of high grade unbreakeble polycorbonate material suitable B22 Base and upto 60 mm pole dia with 10 watt LED lamp coplete all as specified and directed by Engineer-in-Charge
Supply and Repair/Replacement of new generation post top energy saving environmental friendly,long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LED as light sourse Coral (opal) - IP65 suitable for pole dia 76 mm with 25 watt LED lamp complete all as specified and directed.
Supply and Repair/Replacement of Building street light fitting Endura pearl 25W LED lamp new genaration energy saving & environmental friendly long life made up of pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP65 protection and impect resistance of IK07,with suitable of GI pipe (light grade) bracket and clamps,nut bolts are fixed on wall/post and all as required and directed
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-11 (11.0 metres long) all as directed incl dismantling old one. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) all as directed incl dismantling old one.Make: Utkarsh Bansal/ National tubing Co/Jindal/Electrosteel. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.
S&F in repair PVC insulated 3 core 2.5 Sq mm stranded Aluminium conductor cable for connecting OH line/junction box to street light fitting testing and commissioning all as directed.
S&F in repair PVC insulated 3 core 1.5 Sq mm stranded Aluminium conductor cable for connecting OH line/junction box to street light fitting testing and commissioning all as directed.
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete.
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work.
S&F loop-in/loop-out box of outer size size 250x210x115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one.
M & L for disconnecting burnt end or portion of UG Cable, removing the cable from loop including necessary excvation and earth work, relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminal for cable of cross sectional area 10 Sqmm 2 core to 95 Sqmm 3.5 core of LT cable to pole, main switch, LT Panel etc complete all as specified and as directed .
Removing existing 1100 volts grade, XLPE/PVC, armoured, electric power cables (heavy duty) with aluminium conductor of sizes 6 Sqmm 4 core to 70 Sqmm 3.5 core from trench/ duct/ pipe carefully for identifying the defects and relaying the same after rectification of defects complete all as directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
Supply and Repair/Replacement for 250 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repair/Replacement for 63 AMP MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 10 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repair/Replacement for 100 AMP, MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repair/Replacement for 125 AMP, MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repair/Replacement for 800 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repair/Replacement for 400 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repair/Replacement for 200 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repair/Replacement for 160 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repair/Replacement of industrial change over switch gear 200 Amp 415 V Four Pole Off Load Side Handle Operated In Sheet enclosure, Powder Coated, Weather proof conforming to IS: 13947 by connecting the electrical connection and fixing on wall or panel with clamp nut, bolt etc complete all as specified and as directed by Engr-in-Charge.
Supply and Repair/Replacement of industrial change over switch gear 100 Amp 415 V Four Pole Off Load Side Handle Operated In Sheet enclosure, Powder Coated, Weather proof conforming to IS: 13947 by connecting the electrical connection and fixing on wall or panel with clamp nut, bolt etc complete all as specified and as directed by Engr-in-Charge.
Supply and Repair/Replacement of industrial change over switch gear 250 Amp 415 V Four Pole Off Load Side Handle Operated In Sheet enclosure, Powder Coated, Weather proof conforming to IS: 13947 by connecting the electrical connection and fixing on wall or panel with clamp nut, bolt etc complete all as specified and as directed by Engr-in-Charge.
M & L for preparation of old painted surfaces of 09/11 m long PCC poles incl removing oily/greasy sports and applying one coat of synthetic enamel paint of black and yellow in alternate strip of 30 cm witdth upto 1.5 mtr height including including applying a coat of white wash on pole cooping and lettering the pole details with white letters/black background etc complete all as directed
Material and labour for painting to steel tubular pole 9.00/11.0 metre long with one coat of red oxide on pole and two coats of synthetic enamel paint up to 1.20 metre height from ground level in 30 cm alternative black and yellow strips and remaining portion with two coats of aluminium paint complete all as specified and directed by Engineer-in-Charge
Material and labour for numbering of pole no. Using stensils with two coats of Black round and fonts with white in colour complete all as specified and directed by Engineer-in-Charge.
S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carring capacity 32 to 40 Amps complete including control wiring thimbles etc complete all as directed.
S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carring capacity 40 to 100 Amps complete including control wiring thimbles etc complete all as directed.
Supply and Repeir/Replacement of panel mounted volt meter digital type 3 phase as per existing complete all as specied and directed
Repeir/Replacement of panel mounted Ammeter digital type 3 phase as per existing complete all as specied and directed
Taking out any damage of the already installed LT panel board doors/shutter and repair the broken doors by putting necessary nut, bolts, hinges, screw, welding etc and fix it again on the same panel board with two coats of synthetic enamel paint of existing colour complete upto 5 sqm complete all as specified and directed.
Taking out any damage of the already installed LT panel board doors/shutter and repair the broken doors by putting necessary nut,bolts,hinges, welding etc and fix it again on the same panel board with two coats of synthetic enamel paint of existing colour complete exc 5 sqm n exec 10 sqm complete all as specified and directed.
Dismantling the defective LT UT cable 3.5/ 4 core from panel/DB/junction boxes, dismentling the cable gland if any, removing the pitted/burnt aluminium lugs and suplly and fixing of aluminium paim type lugs or lugs as per existing, crimping with suitable size crymping tool bit, refixing/ replacing cable gland, refixing the cable with suitable nut bolts & washers etc complete for the following size cable:- (Note:(i) one set of triple pole and neutral lugs will be measured as one job. (ii) The rate quoted deemed to be inclusive of insulation tape, nut bolts & washers etc complete. (iii)cable gland will be measured and paid separately.(iv) The rate quoted deemed to be inclusive the necessary earth work for removing loop of cable if any required complete all as directed
S&F in replacement on pole street light bracket fabricated out of GI Tubing light grade 40 mm bore Bend to the shape as directed and of length 1.5 mtr complete with mounting MS clamp of flat iron of suitable size 02 Nos incl nut bolts Etc of suitable size all as specified and directed by Engr In charge
Restretching of ACSR conductor of any size of over head lines LT/HT on poles including binding with insulators, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed. Note: ACSR conductor Required for winding etc to be included in quoted rates.
Dismantling unserviceable cross arms including clamps, bolts, nuts, washers etc from pole.
Supply, fabricate and fix cross arms any size along with, brackets, clamps, bolts, nuts, washers, bracers etc including drilling holes, cold/hot complete and fixed to pole including one primer coat and one under and finishing coat of paint.
Dismantling of ACSR conductor of any size, from insulator etc from the structure/over head line all as directed.
M&L replacement of ACSR conductor of any size as ordered by Engr-in-charge including tightening and bindingh with new binding wires to insulators all as directed.
Dismantling insulators any type, size
M&L pin type insulator vitreous, white, brown, or green insulator includig one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65 mm dia for 1100 volts grade.
M&L Stay assembly complete with accessories as shown in electrical plate No. 1 size of dia meter of stay rod in 16 mm (loop type insulator, stay clamps, excavation and concrete measured separately)
M & L for Loop type insulator, vitreous porcelain, white, brown or green Large size, with overall dimensions 90mmx140mm, clearance of hole 25.5mm
M & L for Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, as working pressure 1100 volt
M&L for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Cutting, trimming of hanging/ extended braches of trees upto a distance 3 meter from the overhead HT/LT line and making the line clear upto the entire length of the feeder including removal and disposal of the cut tree branches 50 meters away from the site complete all as specified and directed. Note : The Rates shall inclusive of T&P, hydraulic ladder, equipment such as motorised diesel operated hacksaw etc complete. One span comprises of 3 to 5 conductors of any distance between one pole to adjacent pole including trimming of all tree branches in vicinty & around poles /conductor & will be measured as one span. Necessary prior permission shall be obtained from concerned I/C JE E/M before carrying out the work. All safety measures & insurance to the staff undertaking the Job shall be the Contractor's responsibility.
Supply, Installation and Fixing LT PANEL shall be OEM made out of GRP, Glass-fiber reinforced polyester SMC as per EN 14598-1-UP FR2 material with Protection class IP 54 in accordance with IEC 60529 and Color code RAL 7032 completely dyed in mass and box shall be made out of insulating, slow-burning and self-extinguishing composite (polyester + glass fiber) characterized with resistance to atmospheric agents (UV). Protection class II (EN 61140) when correctly installed on the base and Panel internal size should be not less than 590mm x 800mm x 220 mm. GRP material shall be Anti-corrosive suitable for saline atmosphere and have ambient temperatures of -50°C up to +120°C, Flammability HB 40 a, b (EN 60695-11-10),V-1. Glow wire tested at 960°C/ 3 mm as per EN 60695-2-12. The dimensional stability under heat is more than 200 °C as per ISO 75 – 2 method A . The enclosure is Halogen-free, resistant to termites. GRP cabinet should withstand minimum Di-Electric strength of 130KV/Cm as per IEC 60243-1. The Panel box shall have shall be equipped with GRP handle lock with THREE point locking mechanism and the provision to insert various type of locking cylinders provided to avoid unauthorized access. RoHS Directive (EU) 2015/863 (extension to directive 2011/65/EU),REACH Regulation (EC) no. 1907/2006. The Panel mounted on suitable MS Angle Stand and Copper Bus-bar with Heat Shrinkable Sleeves of capacity 400 Amp, wiring of Panel with suitable size of Copper Conductor Cable, Thimbles, etc. having size of the Panel suitable for fixing the Items/Materials mentioned at here-in-below, complete all as specified and as directed . Make-Hensel/ABB/Emitter/Schneider.
Dismentling old feeder pillar & Supply, installing, testing and commissioning of LT feeder pillar box factory made cubicle outdoor type, fabricated out of 3.00 mm thick CRCA sheet floor mounted with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 320 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 200 Amp 25 KA -01 No (f) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.
Supply and Repair/Replacement for Timer switches Analog type with battery back up of 3P module,24 hours programmable every SST 30 min complete all as specified and directed.
Supply and Repair/Replacement of MCB SPN 6-32Amps,10 KA breaking capacity suitable 230 V,50 Hz for lighting and other domestic load complete all as specified and directed.
Supply and Repair/Replacement of MCB TPN 63 Amps, 10 KA breaking capacitysuitable for 230 V, 50 Hz AC Supply complete all as specified and directed.
Supply and Repair/Replacement of MCB TPN 40 Amps, 10 KA breaking capacity suitable for 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.
Supply only Copper thimble(Lugs) of size suitable for connecting cable of size 25 Sqmm to 50 Sqmm complete all as specifed and directed by Engr-in-Charge.
Supply only Copper thimble(Lugs) of size suitable for connecting cable of size 70 Sqmm to 120 Sqmm complete all as specifed and directed by Engr-in-Charge.
Supply only Alumunium thimble(lugs) of size suitable for connecting cable of size 10 Sqmm to 95 Sqmm complete all as specifed and directed by Engr-in-Charge.
Supply only Alumunium thimble(lugs) of size suitable for connecting cable of size 120 Sqmm to 400 Sqmm complete all as specifed and directed by Engr-in-Charge.
Supply only Alumunium thimble(lugs) for stright through joint of size suitable for connecting cable of size 10 Sqmm to 95 Sqmm complete all as specifed and directed by Engr-in-Charge.
Supply and laying of HDPE DWC (Double wall corrugated) pipe of 40 mm bore outer dia laid for protection of cables in trenches, floors complete all as specified and directed.
Annual maintenance charges online supporting for STP Damtal 200 KLD online monitering of treated water parameters like BoD,CoD,PH,TSS etc as per site requirement support including engr visit minimum 4 times, Repair of all components etc complete all as specified and as directed.
Supply and laying of HDPE DWC (Double wall corrugated) pipe of 50 mm bore outer dia laid for protection of cables in trenches, floors complete all as specified and directed.
Supply and laying of HDPE DWC (Double wall corrugated) pipe of 50 mm bore outer dia laid for protection of cables in trenches, floors complete all as specified and directed.
M&L for complete servicing repair to out door unit of 1.5/2 TR Split type AC Unit, including taking down all the components tinkering the rusted portion, renewal of complete rusted sheet metal parts, with the same thickness M.S. sheet as per the existing size & shape including cutting, bending welding, drilling etc., including renewal of all nut & bolts sheet metal screws, mounting legs, rubber bushes, and cleaning and fixing of all components, brazing the refrigeration piping and shifting to its original position and connecting up all electrical connections and testing, complete all as specified and directed. Note : Cost includes refrigerant tubing, replacement of strainer, CTC, Nitrogen gas, Refrigerant gas, required to and from Transportion and Handling. M/L for spares will be measured and paid separately
Material and Labour for taking down the damage condenser fan blade of 1.5TR split/Window type AC’s of any make and supply & fixing suitable new fan blade and testing & commissioning the unit, complete all as specified and directed.
All as per Item No 119 above, but 2 TR Split AC
Material and Labour for taking down the damaged blower unit of any make split/Window AC and supply and fixing of new blower unit of suitable type and testing & commissioning the unit, complete all as specified and directed.
Material and Labour for taking down the unserviceable temperature sensor probes and supply & fixing new sensor probe suitable for any type, make split/Window type AC’s and testing & commissioning, complete all as specified and directed.
Material and Labour for taking down the defective unserviceable printed circuit Board and S/F of new printed circuit board for any make split/window type AC unit as per site complete all as specified and directed.
Material and Labour for taking down the defective unserviceable sealed fan motor & S&F new fan motor of the same capacity & size to suit the split/window AC unit of any make and capacity of 1.5 / 2 TR all as per existing at site, complete all as specified and directed.
Material and Labour for taking down the damaged air filter set and S/F of new air filter set for split/window type AC’s of 1.5 / 2TR capacity, complete all as specified and directed.
Material and Labour for taking down the defective unserviceable starting capacitors 80/100 MFD 230V / 50Hz as per existing site and supply and Fixing the new starting capacitor of the same capacity to split / window type AC’s and testing, complete all as specified and directed.
Material and Labour for taking down the defective unserviceable starting relay and supply and fixing new rely suitable for 1.5/2TR Window / Split type AC’s and Testing, complete all as specified and directed.
Material and Labour for taking down the defective unserviceable Thermostatic switch and S/F new thermostatic suitable for window type AC’s and Testing, complete all as specified and directed.
Material and Labour for taking down the damaged drain pipe and S/F of new insulated drain pipe suitable for split type AC’s as per sample, complete all as specified and directed.
Material and Labour for taking down the defective capillary tube set and supply & Fixing new suitable capillary set for split type AC’s, complete all as specified and directed.
Material and Labour for taking down the rusted out door unit stand and supply & fixing the stand with required anchor fastner and nut & bolts and rubber bushes for 1.5 / 2 TR Split unit.
Material and Labour for taking down the burned out door unit fan motor and rewinding, overhauling renewal of worn out shaft & bushes, and fixing to the unit, of 1.5 / 2 TR Split units, complete all as specified and directed.
Material and Labour for taking down the defective remote control unit and S/F of new remote control unit for split/window type AC of 1.5 / 2 TR of any make as per site and testing, complete all as specified and directed.
Material and Labour for taking down the defective unserviceable sealed motor of indoor unit of any make split unit of 1.5/2 TR capacity and S/F new fan motor suitable for Split type AC’s, complete all as specified and directed.
Material and Labour for taking down the defective starting capacitor of split / window type AC’s and supply & fixing the new starting capacitor of 80/100 MFD 230V, 275SV-50Hz and Testing for 1.5/2TR AC Unit, complete all as specified and directed.
Material and Labour for taking down the burned wiring kit and supply & fixing and testing of new wiring kit suitable for 1.5/2TR split and window type Ac unit, complete all as specified and directed.
Material and Labour for taking down by disconnecting water connections and shifting elective water cooler to work shop, taking down the defective sealed compressor and replacing with new compressor, the work includes flushing the complete system condenser, cooling coil with Nitrogen, removal all carbon, oil & dirt, brazing & inter connecting the refrigeration lines, de-hydrating, purging with refrigerant, vaccumissing and charging of R22 / 134a Refrigerant and testing & commissioning and shifting to original location and connecting up the electrical & water connection for the following capacity water coolers, complete all as specified as directed.
(a) 40/60/80 Ltrs. capacity water cooler
(b) 120/150 Ltrs. capacity water cooler
M&L for complete tinkering the corroded sheet metal parts, side panel, door, with existing gauge M.S. Sheet and renewal of the bottom base plate, mounting lets, fan motor base plate, and condenser should cover etc., with existing size gauge G.I. sheet, with required Angle Iron, Nut & Bolts all as per the existing size and shape including cutting, bending, welding and completing fixing all other components, complete scraping with old paint, prepare the surface, painting 2 coat of enamel paint over a coat of primer and complete cleaning the water tank and shifting to the location and testing any capacity of water coolers, complete all as specified as directed.
M&L for charging the water cooler of the following capacity including taking down, transporting to workshop flushing out the cooling coil, condenser, brazing the refrigerant lines, replacing of liquid line copper strainer, leak testing, purging with refrigerant, vaccumissing and charging of R22/R 134a gas, testing & commissioning and shifting to the location and connecting up the electrical & water connection, complete all as specified as directed. (Note : Rates are including of gas R22/R134a)
(a) 40/60/80 Ltrs. capacity water cooler
(b)120/150 Ltrs. capacity water cooler
Material and Labour for painting the water cooler including scraping out the old paint prepare the surface, painting 2 coat of enamel paint over a coat of primer, the work including necessary putty, metal paste etc., and disconnecting from the position and refixing after painting for any capacity of the water coolers, complete all as specified and directed.
Material and Labour for water cooler tank and cooling coil by dismantling the water cooler and carried out the lead soldering to cooling coil to the tank outer surface where ever the detached portion and rectify the leaks portion and re-assembly the water cooler of any capacity, complete all as specified and directed.
Material and Labour for taking down the damaged thermal insulation of the water cooler, and renew the thermal insulation as per the existing thickness and assembling the body with necessary sheet metal screws etc., for any capacity water coolers, complete all as specified and directed.
Material and Labour for taking down the defective starting relay and S/F of new starting relay for any capacity water cooler, complete all as specified and directed.
M&L for taking down the defective overload relay and S/F of new over load relay suitable for any capacity water cooler, complete all as specified and directed.
M&L for taking down the defective Running capacitor and Supply & Fixing new running capacitor 20/10 MFD, 440 VAC 50/60 Hz suitable water cooler, complete all as specified and directed.
M&L for taking down the defective starting capacitor and Supply & Fixing new starting capacitor 60/80 MFD, 230V, 270SU-50 Hz for water cooler upto 120 Ltrs. Capacity, complete all as specified and directed.
M&L for taking down the defective Running capacitor and Supply & Fixing new running capacitor of 25/36 MFD, 440 VAC, 50/60 Hz suitable for 150 Ltrs. Capacity water cooler, complete all as specified and directed.
M&L for taking down the defective thermostatic switch and Supply and Fixing of new thermostatic switch for water coolers, complete all as specified and directed.
S&F of 15 mm Concussive push button taps of cast iron, screwed for water cooler of any capacity, complete all as specified and directed.
S&F of (float valve) 15 mm Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for water cooler of any capacity, complete all as specified and directed.
M&L for taking down the damaged drain connections and drain pipe and S/F of new drain connection & pipe with necessary clamps, Nipple, coupling etc., for any capacity water cooler, complete all as specified and directed.
M&L for taking down the defective unserviceable sealed fan motor and S/F new fan motor with suitable capacitor for water cooler upto 40/80, 60/120 ltrs. Capacity, complete all as specified and directed.
M&L for taking down the damaged condenser fan blade and supply and fixing of new fan blade suitable for 40/60/80 water coolers, complete all as specified and directed.
M&L for taking down the corroded air cooler condenser and supply and fixing of new air cooled condenser with necessary brackets and fixing arrangements including welding brazing etc., for water cooling 40/60/80 Ltrs. Capacity, complete all as specified and directed.
M&L for taking down the corroded air cooled condenser and supply and fixing of new air cooled condenser suitable for 1.5 TR Split Ac, complete all as specified and directed.
All as per item No. 159 above, but 2 TR Split AC
S&F in replacement of existing UNSV plug Top 3 pin 5 Amp, complete all as specified and directed.
S&F in replacement of existing UNSV plug Top 3 pin 15 Amp, complete all as specified and directed.
S & fixing aluminium chequered sheets 6mm thick as in floor or on wall icluding matching with the existing floor present on site complete all as specifed and directed.
Removing the old paint of the body of refrigerator of any capacity and making the body dent proof and preparing the surface and Painting the refrigerator with 2 coats of synthetic enameled paint of superior quality to match with existing paint with spray painting, complete all as specified and directed.
S&F in replacement of existing UNSV sealed Compressor unit for Refrigerator of capacity 165 to 185 Ltrs including Gas charging, complete all as specified and directed.
S&F in replacement of existing UNSV sealed Compressor unit for Refrigerator of capacity 285 to 320 Ltrs including Gas charging, complete all as specified and directed.
S&F in replacement of existing UNSV sealed Compressor unit for Deep freezer of capacity 320 Ltrs including Gas charging, complete all as specified and directed.
S&F in replacement of existing UNSV cooling Thermostat switch suitable for refrigerator/deep freezer of any capacity, complete all as specified and directed.
M&L for taking down the complete outdoor unit alonwith its accessories deposite to MES store yard of split AC and Supply and fixing of new out door unit including Compressor,condenser,fan with fan motor,etc complete outdoor set suitable 1.5 TR split unit the work includes dismantling the components and reassembly and fixing to the existing location and testing for any make of split unit.
M&L for taking down the complete indoor unit alonwith its accessories deposite to MES store yard of split AC and Supply and fixing of new indoor unit set complete with acessories including remote,etc suitable 1.5 TR split unit the work includes dismantling the components and reassembly and fixing to the existing location and testing for any make of split unit.
M&L for taking down the corroded air cooled condenser and supply and fixing of new air cooled condenser suitable for 5 TR walking cooler including making suitable connections, bracing , charging of gas etc complete all as specified and directed
M & L for replacement of old unsv fan motor with fan motor suitable for deep freezer of any capacity including all accessories as per site complete all as specified and as directed.
M & L for taking down the defective split/Window unit of 1.5 TR Capacity, shifting to work shop, taking out the defective unserviceable hermetically sealed compressor from the unit,and supply and replacing the compressor with new compressor of the same capacity, fixing to the unit inter connecting the refrigerating lines, flushing out the cooling coil & condenser, removal the coil & carbon thoroughly, cleaning with CTC, leak testing, pressure testing with Nitrogen gas, dehyderating, Vaccumissing, charging of Refrigerant gas, testing at work shop. Shifting to the location reinstalling the same in its Original position connecting up all electrical connection and Testing, complete all as specified as directed.
All as per Item No. 173 above but 2 TR Capacity, Note : Rates quoted are of (a) and (b) deemed to be inclusive of cutting, welding, brazing, sealing the refrigerant tubing, replacement of strainer, CTC, Nitrogen gas, Refrigerant gas, required to and from Transportion and Handling. M/L for spares will be measured and paid separately.
M&L in replacement of existing UNSV MNX-9 contactors as per site sample.
M&L in replacement of existing UNSV MNX-18 contactors as per site sample.
S&F in replacement of existing UNSV over load relay (3 Amp to 16 Amp) for walk-in-cooler as per site sample
M & L for new wiring in replacement of old unsv wiring for desert cooler including all accessories, complete all as specified and directed.
M&L for Replacement of existing UNSV blower motor & fixing the new blower motor suitable for desert cooler single way shaft 240 Volts 50 c/s, complete all as specified and directed.
M&L for Replacement of existing UNSV circulation pump suitable for desert cooler 240 volts 50 c/s single phase Complete all as specified and directed. (As per ground sample)
S&F in replacement of existing UNSV Khaskhas pad honey bee type (set of 3) for Desert Cooler of any capacity ( Set of three), complete all as specified and directed.
Removing the old paint from the body of desert cooler making the body dust proof and preparing the surface and painting the desert cooler with 2 coats of synthetic enamel paint of superior quality over a coat of Red Oxide primer, complete all as specified and directed.
Removing the old rusted base tub of desert cooler and fabrication of base tray and top cover made of PGI sheet of 22 gauge and fixing in position using necessary nuts, bolts and washers, complete all as specified and directed.
S&F in replacement of existing UNSV galvanized iron top cover 0f 24 gauge per and providing new one of existing size, gauge and shape ,nuts and bolts suitable for 3000/4000 cfm capacity Desert Cooler complete all as specified and directed.
S&F in replacement of existing UNSV galvanized iron side pillar of 24 gauge as per and providing new one of existing size and shape ,nuts and bolts suitable for 3000/4000 cfm capacity Desert Cooler, complete all as specified and directed.
S&F in replacement of existing UNSV galvanized iron side shutter of 24 gauge as per and providing new one of existing size and shape ,nuts and bolts suitable for 3000/4000 cfm capacity Desert Cooler, complete all as specified and directed.
S&F in replacement of pre filter bag filter series Z type /as per sample,size as per existingAHU at AC plant complete all as specified and as directed.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
RUHI ASSOCIATES
M/s Northern India Construction co
satpal and brothers
GOLDEN CONSTRUCTIONS
KEWAL SONS
M/S SHAKTI ELECTRIC WORKS
kamal electric works
Ish Engineers and Contractors
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .