| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹37.4 LAccepted-AOC 58 SHAHEED NAGAR OPP BHIMRAO AMBEDEKAR UNIVERSITY RBL ROAD LUCKNOW 226025 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226025 | 1 | Accepted-AOC L-1 | |
| 2 | 2₹37.6 L+₹10,005 (0.27%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹37.9 L+₹43,871.50 (1.17%)Rejected-Finance 93 SARASWATI PURAM COLONY SG PGI LUCKNOW UP 226 014 | LUCKNOW | LUCKNOW | UP | 226014 | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹38.3 L+₹76,407.50 (2.04%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹38.6 L+₹1.0 L (2.77%)Rejected-Finance | 5 | Rejected-Finance Being other than L-1 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
26 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST LUCKNOW
GE EAST LUCKNOW
PROVN OF GATE (FIELD MARSHAL SHFJ MANKESHAW DWAR) AT SP MARG AND SPL REPAIR TO SERVANT QTRS (BLDG NO 2/FH) OF 2 SP MARG OF AREA OF AGE B/R-II UNDER GE (EAST) LUCKNOW
2022_MES_572419_1
GE/E/LKO/T-57 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE EAST LUCKNOW
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE EAST LUCKNOW
₹94,000
Yes
24 Feb 2023
31 Dec 2022
28 Jan 2023
31 Dec 2022
26 Jan 2023
14 Jan 2023
Amount
Demolition of cement concrete (unreinforced ) in floors and pavings not exc 15cm thickness (above or below GL) complete all as specified and directed
Taking down cement or cement lime plaster or stone/brick wall, ceiling including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
Taking down chowkhat or frames with shutter (without taking off shutter from the frame ) area exc 1.5 sqm but not exc 4.0 sqm each complete with hold fasts etc complete all as specified and directed.
Taking down shutters of any description area exc 1.0 sqm and not exc 2.00 sqm each shutter complete all as specified and directed.
Taking down shutters of any description exc 1.00 sqm but not exc 2.00 sqm and easing, ajusting and also refixing builders hardware as required and renewal of unserviceable screws and refixing in the same opening complete all as specified and directed.
S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed
M&L for 25mm thick PCC, 1:2:4, type B-0 using 12.5mm graded stone aggregate as in floors complete all as specified and directed.
M&L non skid coloured ceramic tiles 7 to 8mm thick area of each tile exc 0.18 sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colured cement to match including screed bed 15mm thick in CM 1:6 complete all as specified and directed.
M&L non skid coloured ceramic tiles 7 to 8mm thick area of each tile exc 0.18 Sqm but not exc 0.38 sqm, in vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed plaster 10mm thick in CM 1:4 complete all as specified and directed.
M&L for 30 mm thick with one side decorative laminated flush shutters, solid core construction, with block board 3 core and plywood face panels, commercial type on both sides complete all as specified and directed
M&L brick work with fly ash bricks, straight or curved on plan exc 6M mean radius, old size brick built in CM 1:6 complete all as specified and directed
M&L for 15mm thick rendering in CM (1:6), on other than fair faces of brick work/stone masonary surfaces finished even and smooth without using extra cement, complete all as specified and directed.
M&L for 10mm thick rendering in CM 1:3 on ceiling finished even and smooth without using extra cement, complete all as specified and directed.
M&L 15mm thick rendering in CM (1:4) mixed with water proofing compound @ 3 % by weight of cement on other than fair faces of brick/stone masonary surfaces, finished even and smooth without using extra cement, complete all as specified and directed. (Note:- WPC shall be measured and paid separately 'Only')
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement, complete all as specified and directed.
S&F 100mm mild steel butt hinges, medium weight, cold rolled, ISI marked complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed
S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 300mm long alumimium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolt of extruded section or cast aluminium alloy complete all as specified and directed
Dismantling loose/disintergrated portion of RCC Chajjas, bend shelves, beams balconies and similar work at any position or any height and dubbing out with 15mm to 50mm thick PCC in (1:1.5:3), using 6 to 12mm graded stone aggregate to make up and finished required shape including applying anti corrosive paint on exposed surfaces and provision of necessary supporting form work and including 10mm thick plastering in CM 1:4, finished fair and even, complete all as specified and directed.
Taking down existing treatment any type/any thickness on roof including taking down/removing the backing bed concrete if any and dispose off at a distance exc 100m complete all as specified and directed
M&L for brushing neat cement slurry with 3.0 Kg/sqm over roof slab complete all as specified and directed
M&L of PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in roof padding/ roof kerbs/benching/coved fillets etc rounded or chamfered on edges complete all as specified and directed
M&L for roof/sunkn treatment with polymeric water proofing membrane with certain specification given below as under complete all as specified & directed (a) M&L plastering 10mm in CM 1:4 using 100% course sand on roof including WPC @ 3% by weight of cement. (b) Applying a coat of bitumenous primer @ 0.50 LTRs /Sqm and allow to dry (c) Applying a coat of hot blown bitumen grade 85/25 @ 1.20 Kg/Sqm. (d) Supply and laying APP based polymeric water proofing membrane, weight not less than 3.00 kg/sqm and and minimum 3 mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) sealed the side laps with spread temper (e) Applying a tack coat of hot blown bitumen grade 85/25 @ 1.20 Kg/Sqm
M&L for preparation of new or previously untreated wood and wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of old painted wooden surfaces and applying one coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new surfaces of steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of red oxide complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying 3 mm thick wall care putty complete all as specified and directed
M&L for preparation of newly plastered surfaces of wall and applying two coat of weather proof exterior emulsion paint over a coat of primer on new or old surface of wall complete all as specified and directed
M&L for preparation of newly plastered surface of wall and apply two coats of oil bound distemper over a coat of 1mm thick wall putty, complete all as specified and directed.
M&L for 3 coats of white wash on ceiling including preparation of newly plastered surfaces complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint complete all as specified and directed.
M&L of 50mm thick PCC 1:3:6, type C-1 (using 20mm graded stone aggregate) as in plinth protection finished fair & even laid in alternative bays not exc 2mtr in length and joints filled with bitumen mastic 1:3 complete all as specified and directed.
M&L of 75mm thick cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in sub-floors, sub-bases, etc. complete all as specified and directed
Surface dressing not exc 15 cm deep in soft/loose soil complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5mtr depth and getting out in soft/loose soil complete all as specified and directed
Excavation in trenches exc 1.5m but & not exc 3.0m depth for foundation, etc. or for shafts, wells, cesspits, manholes, etc. not exc 10 sqm on plan and not exc 1.5m depth & getting cut in soft/loose soil complete all as specified and directed
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm complete all as specified and directed
Removing excavated material not exc 100m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
M&L of PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foudation or mass concrete etc complete all as specpfied and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar etc complete all as specified and directed
M&L hardcore of broken stone boulders gauge not exc 63 mm, deposited, spread and levelled in layers not exc 15 cm thick, watered and rolled/rammed to a true surface etc complete all as specified and directed
M&L machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 80 mm thickness, M-35 grade with grey cement and pigment etc complete all as specified and directed
M&L sand filling under floors or in foundation including watering and consolidation etc complete all as specified and directed
M&L exterior tile 30 cm x 30 cm x 25 cm thick set and jointed and pointed in neat cement slurry with grey cement and pigment in floors including 20 mm screed bed in CM 1:6 complete all as specified and directed
M&L for RCC design mix (M-25) using 20 mm graded stone aggregate for foundation footings plinth beams, cloumns up to GL etc complete all as specified and directed. (Note Reinforement shall be measured and paid seperately under relevent item).
M&L for RCC design mix (M-25) using 20 mm graded stone aggregate for coloumn above GL, lintel beam, chajjas, roof beam and slab or similar suspended work etc complete all as specified and directed. (Note Reinforcement shall be measured and paid separatly under relevant items).
M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking and bending spirally for hooping for coloumns, hooking ends and binding with and including mild steel wire not less than 0.9mm dia complete all as specified and directed.
M&L for mild steel TMT bars 6mm to 8mm dia cut to length, bent to shape required incl. cranking, bending and incl. mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed
All as per item No 48 but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for form work flat, rough finished surface of concrete for side of footing columns plinth beams or similar work including any types of supports/scaffolding etc complete all as specified and directed
M&L for form work to polygonal, rough finished surface of concrete for side of columns above GL, lintel beams, chajja, soffits of suspended roof slab and roof beams or similar work including any type of supports/scaffolding etc complete all as specified and directed
M&L for form work to edge and soffits to arches, rough finished surfaces of concrete, suspended roof slab and roof beams or similar work including any type of suports/scafolding etc complete all as specified and directed
M&L for form work to sides and soffits to domes, vaults, shell roofs and arch ribs, rough finished surface of concrete or similar work including any type of supports/scaffolding etc complete all as specified and directed
S&F, dholpur stone cladding gang saw cut with machine cut edges, uniform colour of each stone size exc 0.25 sqm area not exc 0.5 sqm fixed with and including on number stainless steel clamps (grade -202) of flat 30 mmx2mm, 50 mm long made to shape in each slab making V groove at top and bottom of stone and drilling hole for hold fasterner, polishing dholpur stone dust 1:1, complete all as specified and directed.
S&F stainless steel/CP Brass letter or figure (not less than 2.5mm thick) (Block, Roman Italic or Indian) size 300 mm long x 50 mm width) etc including fixing complete all as specified and directed.
M&L for mild steel framed structural work as in doors or gates of angle or ther section with gusset plates, rairls braces etc complete drilled for fixing of steel sheeting or other covering. Doors etc to be prepared for hanging or slinding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing of Fe-410-0 (Gde E- 250) complete all as specified and directed
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete all as specified and directed.
Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
All as per serial item No 59 here-in-before but one bell point controlled by one bell push, 06 Amp.
All as per serial item No 59 here-in-before but one, two way light point controlled by two, two way switches, 06 Amp.
All as per serial item No 59 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.
All as per serial item No 59 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp.
All as per Serial Item No 59 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F in repair switch piano flush type, 06 Amp, single pole, one way, 230 Volt complete all as specified & directed.
S&F in repair switch piano flush type, 06 Amp, single pole, two way, 230 volt complete all as specified & directed.
S&F in repair bell push, flush type, 06 Amp, 230 volt complete all as specified & directed.
S&F in repair socket outlet 2 in 1, 5 pin, 06 Amp, flush type, 230 volt complete all as specified & directed.
S&F in repair switch socket combination outlet 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, universal, 230 volt, four hole complete all as specified & directed.
S&F in repair ding dong bell, AC, 230 volt, single pole complete all as specified & directed.
S&F in repair electronic ceiling fan regulator with rotary step, two module, humfree, AC, 240 volt, 100 Watt and duly ISI marked complete all as specified & directed.
S&F in repair lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified & directed.
S&F in replacement of decorative wall mounting type LED light fitting, 1 x 15 Watt, 230 Volt made up of Polycarbonate including shade, lamp holder, 9/10 Watts LED lamp B22 CDL etc and all accessories pre-wired including connecting up complete all as specified and directed.Make :Philips, Cat No : 30575 (Comet) or equivalent in Havells, CG as approved by GE.
S&F in replacement of integrated LED bulk head fitting 10 Watt, 6500K with IP 65 protection comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete all as specified and directed. Make : Crompton, Cat No : LBHE-10-CDL or equivalent in Havells, Cat No : RUGBYNEONFT10WLED760SSYMBOPC, PHILIPS Cat no WT202WLED6SCWPSUS2PC
S&F in replacement of single side connection LED T8 tube light rod 20 Watt, 6500K of four feet long into and including LED tube light fixture of four feet long with T8 push fit type holders, connector block, end caps, etc including connecting up complete all as specified and directed. Make : Crompton, Cat No : IGP131LT8-16& LT8-20-865-2 or Havells, Cat No : REGALBATTENT8UPT01X22WSSBS & PHOTONULTRA1213T8SSTL20WLED865SPC,Philips cat no TMC 501P1XT-LED22W P 3241
S&F in replacement of single side connection LED T8 tube light rod 8 Watt, 6500K of two feet long into and including LED tube light fixture of two feet long with T8 push fit type holders, connector block, end caps, etc including connecting up complete all as specified and directed.Make : Crompton, Cat No : DMLN1LT8-8& LT8-8-865-2 or equivalent in havells / Philips as approved by GE
S&F in replacement LED wall/surface mounted down lighter, 12 W including electrical connection with PVC three core copper flexible wire & all necessary fixing accessories complete all as specified and directed.
S&F in replacement of LED security light fitting 45 watt, 5700K with IP 66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass, LED lenses, surge protector, electronic driver, etc and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sq mm, 3 core as required for connections and 32 mm bore light grade G. I. tube mounting bracket of 1.5 metre in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as specified and directed.
S&F ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed.
Taking down carefully ceiling fan of any sweep complete with all accessories, dismantling blades and deposit in safe custody of AGE E/M Yard-II and refixing after repair complete all as specified & directed.
Taking down sub main wiring any size with PVC insulated aluminium conductor along with PVC conduit complete all as specified & directed.
Material and labour for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Material and labour for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
S&F in replacement of industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
S&F in replacement of sheet metal enclosure distribution board, double door, single pole and neutral, AC, 240 volt, 12 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
S&F in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SP, AC, 240 volt of 06 to 32 Amp, "C" curve, 10 KA breaking capacity - 12 Nos.
S&F in replacement of MCB, SP, AC, 240 volt of 06 to 40 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
S&F MCB, SP, AC, 240 volt of 06 to 40 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
S&F MCB SPN, 40 to 63 Amps, 240 Volts , breaking capacity 10KA complete all as specified & directed.
S&F MCB three pole & neutral 415 volts100 Amps repturing capacity 25KA complete all as specified & directed.
S&F in replacement of MCB, DP, AC, 240 volt of 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
S&F of exhaust fan single phase, 230/240 Volt heavy duty of size 300 mm sweep 1400 RPM including suitable louvers and making connection with twisted copper flexible wire 23/0.076mm complete all as specified & directed.
Cutting walls any type, making holes for fixing of exhaust fan of any size or sweep and making good surface with fine plastering, finishing and colouring with existing colour matching complete all as specified and directed
Taking down electric meter and refixing on same board after rewiring complete all as specified & directed.
Supply only LED bulb 9/10 Watts suitable for B22 white in colour complete all as specified & directed.
S&F three core 2.5 sqmm copper cable including PVC Conduit medium grade, ISI marked not less than 20 mm dia along with conduit fixing accessories complete all as specified and directed
M&L for writting name in LED lighting system (Field Marshal SHFJ Manekshaw Dwar) with minimum size 300 x 50 mm in glass material IP-66 of complete as per sample complete all as specified & directed.
Cutting chases in concrete wall/stone for laying PVC conduit and making good to facings where required and pointing in cement mortar 1:3, and making good, cutting not exc 20 cm girth complete all as specified & directed.
S&F Uniflood integral flood light with driver inside a PDC housing, highly efficient LED Flood light 110 W IP 66, 5700K Efficiency of >120 Lm/Watts , CRI > 70, THD<10%, PF > 0.95. Surge Protection 4KV with built-in Driver, Short Circuit, Low & High Voltage Protection, Reverse Polarity & Open Load protection and Auto restart, external 10kV Surge protection, Input Operating Voltage Range 140-270V AC complete all as specified & directed.
S&F master LED spot lighter , 7-15W including holder and driver complete all as specified & directed.
S&F LED post top lantern fitting made in die-cast aluminium, glare free indirect lighting distribution, affordable and stylish, robust and limited upward light component for 360° indirect light 45W, 2700K IP 65 protection complete all as specified & directed.
S&F RGBW surface mounted Narrow/Medium beam Projector/ Floodlight luminaire suitable for outdoor applications of Facade Lighting with high power LEDs, should consists of highly efficient, UV and temperature-resistant optics with symmetric distribution. With glass cover, clear/powder coated. Luminaire luminous flux range 1440-1510 Lm. Luminaire having DMX 512 control protocol capable of producing 16.7 million colour options. The luminaire should have options for various beam angles: 8⁰/15⁰/25⁰/35⁰/60⁰/30⁰x50⁰. Power consumption should be between 33W to 38W at steady state full intensity. Power factor of the luminaire shall be more than 0.90. Luminaire should be provided with suitable integral/separate non-integral power supply unit. The lumen maintenance L70@ 25 °C of the LED shall not be less than 70% of the initial lumen after 50,000 burning hours. Ingress Protection should be IP 66 or higher. Housing should be made of pressure Die cast Aluminium with 3-4mm thick safety glass. Impact resistance level should be suitable to site condition minimum IK07. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +45°C, Operating Humidity : 10%-90%, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. Make:- Bajaj BA SP series or equivalent as approved by GE
Supply of DMX Splitter cum Booster, Input Power- 100 to 240 VAC, auto-ranging, 50/60 Hz.,Housing rugged alluminium, Operation Temperature -17ºC ~ +55ºC (0ºF ~ 131ºF) , 2 output ports with 3/5-pin terminal sockets , each port should be optically isolated , Protection Rating IP20 including connection complete all as specified & directed.
S&F DMX Controller System with Standalone interfaces with 2*512DMX channels, future upgradation provision up to 4 DMX universe Port with new Nicolaudie Stand Alone engine (NSA) offering some great possibilities (multi-zone, extended triggers, 16-bit channels management) Intuitive backlit keyboard with 10 presets.Standalone DMX IN triggers: External triggers: 10 buttons for direct access,2 buttons to change scene,+ 1 button to change zone. 16 dry contact trigger ports via 20-Pin IDC Socket. Internal calendar, Backup of the internal clock, 3weeks without power, Memory card microSD card, 32GB max, Input power voltage: 5-5.5V DC 0.6A with power adaopter . Trigger lighting scenes using calendar triggers and conditional rules with New Stand Alone engine, using contact ports, RS232 or over Ethernet. Stand Alone mode with 99 scenes across 5 zones. Buttons: iPhone/iPad/Android remote and programming apps. Temperature: 0 to +50 C°, DMX Compatibility: 8 and 16 bit DMX fixtures, System Compatibility: Windows XP, Vista, 7, 8, 8.1, 10, MAC OS X. Make: Nicolaudie/Pharos/Osram ECUE/Philips iColor (10.6 and +), Linux.: Make: Nicolaudie: SLESA-U11 or equivalentas approved by GE
S&F MCB DB TPN (double door) 4 Ways, 415 Volts including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified & directed.
S&F MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified & directed.
M&L for out door type busbar panel board made out of 3.15 mm thick MS sheet and MS angle section 50x50x6 mm factory fabricated suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted comprising of the following:- a) TPN, Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. b) Incoming MCCB 160 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No c) LED Indicator lamp RYB - 01 set of three. d) Necessary excavation, earth work, PCC lean type D2 and PCC type C2 platform complete all as required. (e) Astronomical Solar timer half Kilowatt controling of light system complete all as specified & directed.
Supplying and laying 1100 Volt grade heavy duty PVC cable with PVC insulated alluminium conductor served with inner sheathing pf PVC tape armoured XLPE cable with galvanized steel wire all PVC sheathed 25 sqmm 3.5 core nominal cross sectional area for service connection complete all as specified & directed.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified & directed
Supply and laying 40 mm bore galvanised steel tubes with all fittings, light grade laid in trenches for cable protection complete all as specified & directed.
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed.
ANIL CONSTRUCTION
M/S Reliance Construction
QUALITY CONSTRUCTIONS CO
m/s durgesh traders & constractions
M/s Ramesh Chandra
M/s Bipin Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .