| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.9 L+₹2.5 L (7.25%)Rejected-Finance AWADHI ROAD ADAJAN 1ST 102 DABKA NO 1 1 6 4 C 4TH FLOOR | GANDHINAGAR | L2 | Rejected-Finance Other than lowest. | |
| 3 | L3₹39.3 L+₹4.9 L (14.1%)Rejected-Finance NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L3 | Rejected-Finance Other than lowest. |
Tender Value
Refer Docs
EMD Value
₹75,000
Closing Date
20 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Adampur
Miliatry Engineer Services AF Stn Adampur 144103
MISC REPAIR TO CERTAIN SINGLE LIVING ACCN INCL E/M SERVICES AT AF STN ADAMPUR.
2023_MES_605662_1
GE/AF/ADM-22/2023-24
Open Tender
Civil Works
Item Rate
180 days
Under GE AF Adampur
Refer NIT and tender documnets
8 documents required · 8 mandatory
₹500
GE AF Adampur
₹75,000
Yes
5 Sept 2023
26 Jun 2023
21 Jul 2023
26 Jun 2023
20 Jul 2023
7 Jul 2023
27 Jun 2023 - 6 Jul 2023
Amount
B/R WORKS
PCC type E-2 (1:5:10), using 40 mm graded stone aggregates as in filling & mass concrete, sub base, complete all as specified.
Brick work using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified.
Factory made 35 mm thick ,2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a);,etc complete all all as specified.
Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, thickness 30 mm,etc complete all all as specified.
Factory made solid PVC Door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with mild steel square tube, suppling & fixing in opening, complete all as specified.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top rail, lock rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stile and rails with suitable PVC sheet beading and jointed together with solvent cement as specified in SSR Part II, complete all all as specified.
Factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3±0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. complete all as specified.
NOTES APPLICABLE TO SERIAL ITEM 7: - (i) After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality. (ii) Glass or wiremesh shall be paid separately) (iii) For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Aluminium anodised barrel tower bolt of extruded section 150mm long, ISI marked, complete all as specified.
Aluminium alloy, anodised, ISI marked sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy 300 mm long, complete all as specified.
Mild steel helical door spring 200mm, ordinary rat tail rod pattern including roller and roller plate ISI marked, complete all as specified.
Stainless steel butt hinges,100mm long, ISI marked, complete all as specified.
aluminium anodised handles cast type 125 mm long, ISI marked complete all as specified.
Double leg aluminium anodised door stopper with rubber foot, ISI marked and fixed to bottom rail of doors with steel screws, IN REPAIRS, complete.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples all as specified.
Stainless steel conduit, not less than 20 mm bore, cut to size and erected in position as curtain rod on backets, including SS decorative finials & brackets fixed to walls with PVC rawl plugs & SS screws, IN REPAIRS, complete.
Mild steel works in hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) in-cluding all necessary drilling, bolting or riveting, etc., confirming to Fe-290-Gde E-165, complete all as specified.
Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., confirming to Fe-290-Gde E-165, complete all as specified.
Framed mild steel work such as grills, grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-290-Gde E-165,complete all as specified.
Mild steel rolled sections as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to grade Fe-290-Gde E-165, complete all as specified.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, IN REPLACEMENT, complete all as specified.
Factory made steel windows with side hung shutter with glazng bars each shutter having 02 No. box type hinges & two nos. tower bolts of size not less than 150 mm size and peg stays, dovetailed or welded, complete.
Factory made steel windows with side hung shutter without glazng bars each shutter having 02 No. box type hinges & two nos. tower bolts of size not less than 150 mm size and peg stays, dovetailed or welded, complete.
Steel windows or ventilators, fixed type made of MS sheet 1.25 mm thick box type (primer coated), ERW hollow 'P' section of size 60mm x 25 mm complete all as specified. NOTES APPLICABLE TO SERIAL ITEM NO. 21 TO 23: (a) Profile section used under these items shall be 'P' tube as shown in drawing No. CE/AF/STD-170/07, CE/AF/STD-171/07 and CE/AF/STD-172/07 as applicable.
Pressed steel frames made out mild steel sheet 1.25 mm thick, for doors with one or more rebates including necessary fixing lugs, 100 mm size butt hinges ISI Marked, lock strike plates etc and applying a shop coat of red oxide primer including providing PCC (1:3:6) type C-0 using 12.5 mm graded crush stone aggregate for filling back of chowkhats complete all as specified for size of frame: -
105 mm x 60 mm
125 mm x 60 mm
Water Proofing Treatment to RCC roofs comprising of : -
Taking down existing water proofing treatment (any no. of layers) from RCC roofs including cleaning the surface including flashings and junction of parapet etc. with wire brushing & water to the entire satisfaction of EIC, complete all as specified.
PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, laid to slope as directed by Engineer in Charge over RCC roofs as padding, complete all as specified.
Rendering 15 mm thick (Average thickness) rendering on roof surface including flashings and junction of parapets etc., finished even and fair in cement mortar (1:4), using water proofing compound as recommended by manufacturers after brushing cement slurry @ 1.20 kg/Sq. m, complete all as specified. NOTE: Supply only WPC will be measured & paid for separately under respective item of BoQ.
APP based polymeric membrane laid on primed roofs & flashing by forced application using Butane torch and sealing all joints on primed surface by applying hot blown industrial grade bitumen @ 85/25 @ 1.20 kg/Sq.m over a coat of bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces & flashings complete, all as specified.
40 mm thick brick tiles are bedded over 15 mm thick cement mortar (1:4), and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on APP membrane complete all as specified.
Making benching with PCC (1:2:4) type B-0 (using water proofing compound) along side walls adjoining to roofs, in CONCAVE SHAPE, complete all as specified. NOTE: WPC will be measured and paid for separately under respective item of BoQ.
Water Proofing Treatment to RCC sunken surfaces comprising of :
Rendering 15 mm thick (Average thickness) rendering on sunken surfaes including flashings, finished even and fair in cement mortar (1:4), using water proofing compound as per recommended ratio, after brushing cement slurry @ 1.20 kg/Sq. m, complete all as specified. NOTE: Supply only WPC will be measured & paid for separately under respective item of BoQ.
LDPE sheet 150 micron laid over applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. m & adjoining vertical surfaces including applying bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces complete all as specified. NOTES: For Guarantee of Water Proofing Treatment refer PS clause 11.5 of CA.
NOTE SERIAL ITEM No. 25 & 26 : For Guarantee of Water Proofing Treatment refer PS clause 11.5.
Supply only water proofing compound (WPC), ISI marked, complete all as specified.
uPVC pipes, 160 mm external dia pipe, type-A, ISI marked (IS:13592) single socketed in any length with or without rubber ring joints, fixed to wall with PVC brackets as SWR / rain water pipes, IN REPAIRS, complete all as specified
uPVC/PVC bends any radius, suitable for uPVC soil waste discharge pipes 160 mm external dia complete all as specified.
25 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate, finished rough, as in sub floors or similar locations, complete all as specified.
75 mm thick, cement concrete type C-1, 1:3:6 using 20 mm graded stone aggregate, finished even & smooth without using extra cement, as in plinth protection, and joints shall be sealed with joint sealing comound grade 'A' complete all as specified.
Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified.
Machine cut Kota stone slab flooring 16-22 mm thick, area of each slab not less than 0.30 sq.m, (cut to size in square shape) laid in floors over & including 20 mm thick (average thickness) cement mortar (1:4) screed and jointed with grey cement slurry mixed with matching shade pigment including rubbing and polishing (Granite finish) complete, all as specified.
Kota stone slab 16-22 cm thick on vertical surfaces like riser of steps, skirting, dado and pillar laid over & including 10 mm thick (average thickness) cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (Granite finish), complete all as specified.
Glazed ceramic coloured tiles 6-7mm thick, area of each tile exc. 0.13 Sq.m but n. exc. 0.18 Sq.m, on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in grout of shade matching to tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified.
Non skid ceramic coloured tiles 6-7 mm thick (square/ rectangular) area of each tile exc. 0.08 Sq.m but n. exc. 0.16 Sq.m laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement with pigment to match the shade of tile laid over and including 15 mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement complete all as specified.
Vitrified coloured tiles firts quality 7-8 mm thick (square/ rectangular) area of each tile exc. 0.35 Sq.m but n. exc. 1.00 Sq.m laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement with pigment to match the shade of tile laid over and including 15 mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement complete all as specified.
Vitrified coloured tiles first quality 7-8 mm thick (square/ rectangular) area of each tile exc. 0.35 Sq.m but n. exc. 1.00 Sq.m on vertical surfaecs as in skirting dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement with pigment to match the shade of tile laid over and including 10 mm thick plaste in cement mortar (1:4) including necessary cutting and waste as per site requirement complete all as specified.
Rendering 5 mm thick on fair faces of concrete surfaces, finished fair and even on ceiling surfaces in cement mortar (1:3), complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6) complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), mixed with water proofing compound as per manufacturers instructions, complete all as specified.
Repairing of RCC projection chhajjas, roof, facia etc by necessary scraping cutting, chiseling derusting,preparation, and cleaning exposed reinforcement, surfaces of damaged, loose RCC with cement concrete (1:1.5:3) using 20mm graded stone aggt and reinforcement with & including mild steel chicken mesh and finished with cement and sand mortar (1:3) using coarse sand and work in patches area n.exc 5 Sq.m and thickness of RCC member n.exc 70mm incl necessary formwork complete all as specified. NOTE FOR SER ITEM 41 & 42: Supply only WPC will be measured and paid for separately under respective item of BoQ.
One coats of interior acrylic distemper on old ceiling surfaces, including preparation of surfaces, complete all as specified.
Two coats of interior acrylic distemper on new ceiling surfaces, including preparation of surfaces, complete all as specified.
Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces etc. as specified (preparatory to paint as directed). (b) Two coats of interior acrylic distemper over and including a coat of acrylic emulsion primer.
Complete removal of existing treatment from plastered wall surfces and applying the following including preparation of the surfaces to the entire satisfaction of EIC: - (a) Applying wall care putty, in two coats & smoothening the surfaces etc. as specified (preparatory to paint as directed). (b) Two coats of interior acrylic distemper over and including a coat of acrylic emulsion primer.
Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed). (b) Two coats of exterior acrylic emulsion over and including a coat of water based exterior primer.
Complete removal of existing treatment from plastered wall surfces and applying the following including preparation of the surfaces to the entire satisfaction of EIC: - (a) Applying wall care putty, in two coats & smoothening the surfaces etc. as specified (preparatory to paint as directed). (b) Two coats of exterior acrylic emulsion over and including a coat of water based exterior primer.
NOTES APPLICABLE TO SERIAL ITEM NO. 43 TO 48: (i) Entire quantity of material for this work shall be procured by the contractor from manufacturer's Depot & deposit the same with Enginer-in-Charge and same shall be issued to contractor on daily basis as per consumption at site. (ii) The work shall be got executed through paint manufacturer/ authorised applicators of manufacturer's as specified in relevent PS clause.
Sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in squares n. exc. 0.5 Sq.m in each pane complete all as specified.
Figured glass pin head type 4 mm thick, and glazing with oil putty or wooden beads in squares n. exc. 0.5 Sq. m in each pane complete all as specified.
Applying one coat (finishing coat) of synthetic enamel paint, including preparation of old painted wood and wood based surfaces of any description not other wise described over 10cm width or girth and complete all as specified.
Two coats of synthetic enamel paint over & including a coat of pink primer over wood and wood (new) based surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces complete all as specified.
Applying one coat (finishing coat) of synthetic enamel paint including peparation of old painted steel & iron surfaces of any description not other wise described over 10cm width or girth, complete all as specified.
Two coats of synthetic enamel paint over & including a coat of red oxide primer over steel & iron (new) surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified.
Steel tubes ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, including taking up or down steel tubing and connections from existing location, complete all as specified of size: -
15mm bore
20mm bore
Steel tubes 50 mm bore ‘medium grade’, galvanized with all fittings and fixed as in wall, inside end fixed with & incl wire netting & external bevelled edge at 45 degree complete all as speciifed.
Disconnecting existing tanks of capacity exceeding 500 litre but not exceeding 1000 litre, setting aside (or lowering if required) for cleaning/roof repair etc. and hoisting, reconnecting and re-fixing in position after necessary cleaning by removing all scale and dirt etc. including cleaning mouth of circulating service pipes complete, all as specified.
Angular stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE:PRAYAG Cat No. P-6510 or equivalent make mentioned in Appndix 'B'.
Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE:PRAYAG Cat No. P-6508 or equivalent make mentioned in Appndix 'B'.
Stainless steel towel rail 600 mm long, fixed to wall with SS screws and PVC rawl plugs, IN REPAIRS, complete. MAKE: PRAYAG Cat No. BA-10S or equivalent make mentioned in Appndix 'B'.
Wall mixture telephonic type with crutch, cast copper alloy chromium plated, screwed down, high pressure, with long screwed shanks for 15 mm bore iron pipe, fixed IN REPLACEMENT, complete. MAKE: PRAYAG Cat No. 6570 or equivalent make mentioned in Appndix 'B'.
Centre hole basin mixture pillar mounted tap of 15mm bore dia, cast copper alloy chromium plated, screwed down, high pressure, with long screwed shanks for iron pipe, fixed IN REPLACEMENT, complete. MAKE: PRAYAG Cat No. 6550 or equivalent make mentioned in Appndix 'B'.
125mm overhead ABS shower with cast copper alloy chromium plated arm 225 mm long with flange and fixed in position, IN REPLACEMENT, complete. MAKE: PRAYAG Cat No. BS-76 or equivalent make mentioned in Appndix 'B'.
Single piece ceramic china EWC (Pedestal pattern) with soft close seat cover, hinges, accessories set and flushing cistern of size 360X 640 X 685 complete including making good to floor, IN REPLACEMENT, complete all as specified. MAKE: PRAYAG or equivalent make mentioned in Appndix 'B'
Vitreous China wash basin, white, flat back, size 550 x 400 mm, ISI marked, including fixing acessories like rag bolts etc. with CP waste coupling half or full threaded suitable for & including 32 mm size PVC solid waste pipe, IN REPAIRS, complete all as specified. MAKE: PRAYAG Cat No. 4645 or equivalent make mentioned in Appendix 'B'
Bath mirror cabinet, PTMT of size 450 mmx 350 mm, fixed to wall with SS screws and PVC rawl plugs, IN REPLACEMENT, complete. MAKE: PRAYAG Cat No. 557 or equivalent make mentioned in Appndix 'B'.
PVC connections 15 mm size of length 450 mm with PTMT nuts, IN REPAIRS complete all as specified.
Stainless steel soap dish, IN REPAIRS complete. MAKE: PRAYAG Cat No. BA-15S or equivalent make mentioned in Appndix 'B'.
Corner glass shelf 300 mm size with brass brackets fixed to wall with SS screws and PVC rawl plugs, IN REPLACEMENT, complete. MAKE: PRAYAG Cat No. BEA-44 or equivalent make mentioned in Appndix 'B'.
uPVC pipes, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed under floors / walls as SWR pipes, IN REPLACEMENT, complete all as specified of size: -
75 mm external dia pipe
110 mm external dia pipe
uPVC/PVC bend any radius, IN REPLACEMENT, complete all as specified, suitable for uPVC soil waste discharge pipes of size: -
75 mm external dia pipe
110 mm external dia pipe
uPVC floor trap, suitable for uPVC soil waste discharge pipes 75 mm ext dia, embedded in PCC type B-1(1:2:4), IN REPAIRS, complete all as specified,
uPVC / PVC 32 mm dia collapsible waste pipe, complete all as specified. MAKE: PRAYAG Cat No. 3272 or equivalent make mentioned in Appndix 'B'
INT ELECTRIFICATION WORKS
Point wiring with multi-stranded copper conductor, single core, FRLS PVC insulated and unsheathed cable, including FRLS PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ sockets comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One light point controlled by two nos. 2-way switches with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
One Socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
Switch piano flush button single pole one way, 6 Amp complete all as specified.
Switch piano flush button single pole two way, 6 Amp complete all as specified.
Switch piano, bell/buzzer push, flush button single pole one way, 6 Amp complete all as specified.
Switch piano flush button single pole one way, 16 Amp complete all as specified.
Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, flush type, complete all as specified.
Socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, flush type complete, all as specified.
Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified.
Electric buzzer AC 230 volt, single pole, Ding Dong type. IN REPLACEMENT complete, all as specified.
Fan regulator (electronic) suitable for 48”/56” sweep fan, stepped socket type, single phase, IN REPLACEMENT complete all as specified.
Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated multi stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLS PVC insulated multi stranded copper conductor 1.1 KV grade for earthing in concealed conduits medium grade complete all as specified for the following: -
2 runs of 4 Sq. mm main cable + 1 run of 4 Sq. mm earth cable
2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable
NOTES: (i) Conduit & conduit accessories shall be measured & paid for separately. (ii) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as "1 RUNNING METRE"
Rigid non metallic, PVC concealed conduit, 25 mm bore, medium grade, ISI marked, inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring and the like complete all as specified.
Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, IN REPLACEMENT, complete all as specified comprising the following: -
SPN, 8 way with 200 Amp rated bus bar, 240 V, double door type.
TPN, 4 way with 200 Amp rated bus bar, 415 V, double door type and including MCCB 4 pole 63 Amp, 16kA.
MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp, complete all as specified.
MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6-32 Amp, complete all as specified.
Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 4 Sq. mm GI wire earthing lead including test point complete all as shown in electrical plate No. 3 and specified in Particular Specifications clause 19.3.3.1 of contract, IN REPAIRS. NOTE: (a) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate. (b) Factory made precast PCC pit with cover shall be fixed at least 500 mm away from earth pit.
Environment friendly, modern design, energy saving surface mounted, decorative 10 W bulk head LED luminaire with premium quality diffuser fo glarefree light, 6000K, IN REPLACEMENT, complete. MAKE: Havells Cat No. HEXAFT10WLED857SSYMBOPC or equivalent in makes mentioned in Appendix 'B' here-in-after.
Surface mounted Environment friendly LED batten with powder coated aluminium housing with intigrated electronic driver with THD<10% LED 10 W lighting fixture, 6500K, lumen output should not be less than 90 lumens per watt IN REPLACEMENT, complete. MAKE: Havells Cat No. ENDURALINEARNEOBS10WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
Surface mounted envirnment friendly LED batten with powder coated aluminium housing with intigrated electronic driver with THD<10% LED 20 W lighting fixture with extruded polycarbonate, 6500K, lumen output should not be less than 90 lumens per watt IN REPLACEMENT, complete. MAKE: Havells Cat No. LUMILINESMART20WLED865PCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
DEMOLITION & DISMANTLING WORKS
Taking down cement plaster of any description on brick walls or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
Taking down shutters of any description exceeding 1.00 sqm but not exceeding 2.00 sqm each and removing from site all as specified.
Taking down shutters of any description exceeding 1.00 sqm but not exceeding 2.00 sqm each and refixing in the same opening after after tiling work complete all as specified.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sq.m each and removing from site all as specified.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sq.m but not exceeding 4.00 Sq.m each and removing from site all as specified.
Dismantling floor, hearth or wall tiling, stone slab(s) including cement mortar bedding and removing rubbish off the premises complete all as specified.
Demolition brickwork or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified.
Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified
Demolition of stone slabs, kotastone/ granite slab of any description or thickness in floor etc complete all as specified .
Demolition of mud in roof any thickness incl plastering & leeping removed complete all as specified.
Dismantling brick tiles or teraccing tiles, single layer on roofs etc complete all as specified.
Dismantling wrought iron of mild steel work of any description in any postion or otherwise specifically provided complete all as specified.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
Taking down carefully existing electric water heater of any description and re-fixing same or other location with all accessories complete all as specified.
NOTE: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline.
siddharthenterprises
M/S GURBACHAN SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .