Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC 29 IQBAL COLONY SONWAR SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.3 L+₹92,933 (4.79%)Rejected-Finance 254 GOVT HOUSING COLONY CHANNAPORA SRINAGAR 190015 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190015 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹21.3 L+₹1.9 L (9.84%)Rejected-Finance FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹27.0 L+₹7.6 L (39.0%)Rejected-Finance | L4 | Rejected-Finance Not being L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
21 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 WORKS ENGRS
CWE, HQ 133 WORKS ENGNRS
MAINTENANCE OF 33 KV AND 11 KV HT NETWORK AT BB CANTT SRINAGAR UNDER GE 864 EWS
2023_MES_605224_1
CWEK-13/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
HQ 133 WORKS ENGRS
Class D Category b ii
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹60,000
Yes
HQ 133 WORKS ENGRS
28 Dec 2023
23 Jun 2023
29 Jul 2023
23 Jun 2023
21 Jul 2023
8 Jul 2023
23 Jun 2023 - 1 Jul 2023
3 Jul 2023
Amount
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches n. exc. 1.5 mtr in wide and exc. 1.5 mtr but n exc 3.0 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
M&L for Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I. Note :- 1. Dry fine sand of best available quality shall be used. 2. Punned thickness shall be measured and paid.
M&L for Sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
M&L for Cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete for fixing poles etc including excavation of any strata and relaxing taken out cable complete all as specified and directed.
M&L PCC (1:2:4) type C-1 (using 20 mm graded crushed stone aggregate) in coping / plinth blocks for poles and the like including weathering , slightly rounded or chamfered angles and throating, as directed including necessary Steel form work and finishing the surfaces fair in forms complete all as specified and directed.
Supplying, fixing, cable jointing kit for 33 KV (Earthed) grade cable for in replacement of unserviceable straight through heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 300 Sqmm complete all as specified and directed.
Supplying, fixing, cable jointing kit for 11 KV (Earthed) grade cable for in replacement of unserviceable straight through heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
Supplying, fixing, cable jointing kit for 11 KV (Earthed) grade cable for in replacement of unserviceable straight through heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
Supplying, fixing, jointing and testing and replacement of unserviceable Heat shrinkable cable end joint , out-door type with and including jointing materials suitable for 11 KV , XLPE cable of size 300 sqmm , 3 core, complete all as specified and directed.
Supplying, fixing, jointing and testing and replacement of unserviceable Heat shrinkable cable end joint , out-door type with and including jointing materials suitable for 11 KV , XLPE cable of size 120 Sqmm to 185 sqmm , 3 core, complete all as specified and directed.
Supplying, fixing, jointing and testing and replacement of unserviceable Heat shrinkable cable end joint , out-door type with and including jointing materials suitable for 11 KV , XLPE cable of size 95 sqmm , 3 core, complete all as specified and directed.
Supply and fixing in replacement of unserviceable insulator post type insulator 254 mm height, 210 mm dia for 33000 volts grade. including 01 galvanized M.S.spindle, two galvanised iron washers and one galvanised iron nut straps etc including taking down old one complete all as specified and directedby Engineer-in-Charge.
S & F in replacement of unserviceable Disc type, insulator three in series, porcelain, vitreous, 145mm height and 255mm dia ball and socket type, white brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts with GI nut, bdfs straps etcincluding taking down old one complete all as specified and as directed.
Supply and fixing Air break gang orerated switches vertical / horizontal mounted including 12 insulators and oprating mechanism for repair/replacement of broken /worn out components and insultors etc for current rating upto 200 Amps 11000 Volts. complete all as specified and as directed.
All per item No 17.00 here-in-before but current rating up to 200 amps for 33000 volts complete all as specified and as directed.
Supplying, laying or fixing, jointing and testing in repair / replacement of unserviceable HT under ground electric power cable, XLPE insulated, screened , PVC bedded, galvanised steel strip or wire armoured, (conforming to ISI-7098), ISI Marked, with aluminium conductor multi-stranded, heavy duty, 11000 Volts grade (earthed), laid in trenches/laid under floor, roads, paths or fixed on walls /on poles/in ducts etc 95 Sqmm 3 Core, complete all as specified and directed.
Supplying, laying or fixing, jointing and testing in repair / replacement of unserviceable HT under ground electric power cable, XLPE insulated, screened , PVC bedded, galvanised steel strip or wire armoured, (conforming to ISI-7098), ISI Marked, with aluminium conductor multi-stranded, heavy duty, 11000 Volts grade (earthed), laid in trenches/laid under floor, roads, paths or fixed on walls /on poles/in ducts etc 185 Sqmm 3 Core, complete all as specified and directed.
S&F in replacment of u/s tubing 'light grade' galvanised iron with all fittings including fixing on poles, walls etc. with flat iron clamps/ bolts / nuts/ washers or laid in floors/under roads 150 mm bore complete all as specified and directed.
S&F in replacment of unserviceable tubing 'light grade' galvanised iron with all fittings including fixing on poles, walls etc. with flat iron clamps/ bolts/ nuts/ washers or laid in floors / under roads 80 mm bore complete all as specified and directed.
S&F in replacment of unserviceable tubing 'light grade' galvanised iron with all fittings including fixing on poles, walls etc. with flat iron clamps / bolts/ nuts/ washers or laid in floors / under roads 50 mm bore complete all as specified and directed.
Dismantling of unserviceable ACB and S&F ACB 4 Pole, 415 volt, with microprocessor release, adjustable release mannual draw type of capacity up to 630 Amps, 65 KA including testing and commisioning complete all as specified and directed.
Dismantling of unserviceable ACB and S&F ACB 4 Pole, 415 volt, with microprocessor release, adjustable release mannual draw type of capacity up to 800 Amps, 25 KA including testing and commisioning complete all as specified and directed.
S&F in repair/ replacement for power tansformer 6.3 MVA(OLTC), AC 3 phase, outdoor type for following items complete all as specified and directed. Make: Alstom/ABB HT VCB's
(a) Epoxy Arm - 01NO
(b) Transit resistance coil - 03Nos
(c) Main moving contact - 03Nos
(d) Arc/resistance contact - 03Nos
(e) OLTC auxiliary PVC insulated armoured copper cable 4 core 26 sqmm 1100 volt.
M & L for replacement of damaged copper bus bars having length 5-6 mtr, 25 mm dia complete all as specified and as directed.
S & F in replacement of heat shrink insulation tubes for all the bus bars and maintaining the RYB sequence in the system complete all as specified and as directed.
M & L for Calibration and programming of all KV, PF, AMP and multifunction meters on different settings and as per the CTR Ratio complete all as specified and dirceted.
M&L for testing complete with testing kit for HT VCB / Panel 33 KV indoor/ outdoor complete with calibration of all protective devices and over hauling of all mechanical parts of VCBs comprising (6 Nos out door type and 3Nos indoor type VCB and OLTC - 03 Nos for 33 KV ) all as directed.
Maintenance and complete overhauling of 11 KV, VCB including disassembling of operating mechanism parts, well cleaning with petrol and CRC-226 and replacing minor parts reassembling of parts including well cleaning the complete panel board, main bus bar, de-carbonizing all joints bus bar,CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete all as specified and directed. Note :- spare parts will be measured and paid separately as under
S&F in repair/ replacement for HT VCB 11 KV, AC 3 phase, 50 HZ indoor type for following items complete all as specified and directed.
(a) Control wiring of HT VCB pannel with suitable size of copper wire complete with color code ferruls and tinned copper lugs.
(b) Trip coil 110 volt DC.
(c) Bakelite housing set.
(d) Spout set (set of three) shower and rose contacts.
(e) Auxiliary switch.
(f) Limit switch.
(g) Rotary switch.
(h) Auxiliary Contactor.
(j) Closing Coil 110 volts.
(k) Tripping lever.
(l) Charging lever.
(m) Charging gear for VCB.
(n) Indication lamp 110 volts (R, Y, B).
(o) Tripping pin.
(p) Push Button.
(q) Charging Motar complete 220 Volts.
(r) Charging Motar complete 220 Volts.
(s )Tublar bus bars copper 25 mm dia
(t )Heat shrink tubes RYB Colours
M & L for Earthing complete with galvanised steel earth plate electrode 60x60cmx 6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate,with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4,funnel with wire gauge of (0.68) 8 mesh per liner inch,80mm thick RCC pit cover 320 mmx320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM,JALLI and charcoal dust and common salt all as shown in electrical plate No.3 of MES SSR Part-1 and specified including provision of earth wire protected by 25 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore medium graded GI pipe,and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/LT panel etc.and testing on completeion complete all as spec ified and directed. NOTE: The quoted rate of earthing shall be deemed to included cost of up to 7.0m long galvanised earth lead wire 4mm and protection pipe of 25 mm bore medium graded ,GI light graded 20mm bore watering pipe
M & L for Earthing complete with galvanised steel earth plate electrode 60x60cmx 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate,with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4,funnel with wire gauge of (0.68) 8 mesh per liner inch,80mm thick RCC pit cover 320 mmx320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM,JALLI and charcoal dust and common salt all as shown in electrical plate No.5 of MES SSR Part-1 and specified including provision of earth wire protected by 40 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore medium graded GI pipe,and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/LT panel etc.and testing on completeion complete all as spec ified and directed. NOTE: The quoted rate of earthing shall be deemed to included cost of 7m long galvanised earth strip 25x4 mm and protection pipe of 40 mm bore medium graded ,GI light graded 20mm bore watering pipe
M & L for replacement of damaged earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation fer loop earthing etc.as required 25x4mm galvanised iron strip complete all as specified and as directed
M&L boring of holes under roads pavements hards standing by trenchless technology using ulta sound technique & necessary machine including HDPE pipe of 6 kg/sqmm of 150 mm dia suitable 0.4 Mpa working pressure all as specified & directed by Engineer-in-Charge.
S&F CT 33 KV outdoor type single Phase oil cooled CT of ration 33 KV DC class 150/5/5, burden 50 VA, insulation level 70/170 KV voltage factor 1.2 Cont and 1.9 for 30 second confirming to IS 3156 including taking down old unserviceable CT complete all as specified and directed.
S&F PT 33 KV outdoor type single Phase oil cooled PT of ration 33 KV DC class 0.50-3, burden 50 VA, insulation level 70/170 KV voltage factor 1.2 Cont and 1.9 for 30 second confirming to IS 3156 including taking down old unserviceable PT complete all as specified and directed.
Trimming of tree branches touching with HT over head line in the entire cantonment so as to maintaining sufficient clearance and avoid fault on over head lines complete all as specified and directed.
M&L for preparation of old painted surface of 33 KV yard channel, angle iron by scrubbing, cleaning and painting with two coat of aluminium paint including writing SM No / MES No of all other items comkplele all as specified and directed.
Supply, installation, testing and commisioning of Lightining Arresters expulsion type, distribution class with all fittings and fixing arrengements suitable to 33000 volts grade and discharge capacity upto 65 KV with and including making connections with suitable size of ACSR conductor including taking down old one complete all as specified and directed.
Supply, installation, testing and commisioning of Lightining Arresters expulsion type, distribution class with all fittings and fixing arrengements suitable to 11000 volts grade and discharge capacity upto 65 KV with and including making connections with suitable size of ACSR conductor including taking down old one complete all as specified and directed.
Surface dressing not exceeding 15 cm deep and averaging 10 cm deep and cleaning of surroundings of electrical installations 11 KV & 33 KV sub stations 2/ & 4 pole structure by cutting vegetation, bushes, grasss etc, complete all as specified and directed.
M&L for cement concrete, 1:3:6 type C-2 (using 40 mm graded stone aggregates) as in foundation, filling, mass concrete for repair of existing structure of transformers/panels/poles etc complete all as specified and directed.
Material and labour for danger notice plate of 1.6 mm thick mild steel sheet, vitrous enamelled white with letters, figures and conventional skull and bones in signal red color, Voltage depiction in Red Colour and fixed with GI clams, bolts and nuts of approved size for HT 20 x 15 cm complete all as specified and directed.
Material and labour for danger notice plate of 1.6 mm thick mild steel sheet, vitrous enamelled white with letters, figures and conventional skull and bones in signal red color, Voltage depiction in Red Colour and fixed with GI clams, bolts and nuts of approved size for HT 25 x 20 cm complete all as specified and directed.
M & L for stay assembly complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately), Diameter of stay rod in 20 mm, complete all as specified and as directed.
M & L for taking down/dismantling of old unserviceable stay assembly of any size, complete all as specified and as directed.
M & L for Loop type insulator,vitreous porcelain,white, brown or green, large size, with overall dimensions 90 x 140mm clearance of hole 25.5mm, complete all as specified and as directed.
Supply and fixing, cable route marker for HT cable duly engraved (HT 33 KV cable) on 150mm dia MS round plate 10mm thick, duly painted with red colour paint and fixed on MS angle of size 40mmx40mmx5mm with nuts and embedded in PCC (1:2:4) concrete block of size 230mmx230mmx150mm, complete with excavation work etc reqd to complete all as specified and as directed.
Supply and fixing, cable route marker for HT cable duly engraved (HT 11 KV cable) on 150mm dia MS round plate 10mm thick, duly painted with brown colour paint and fixed on MS angle of size 40mmx40mmx5mm with nuts and embedded in PCC (1:2:4) concrete block of size 230mmx230mmx150mm, complete with excavation work etc reqd to complete all as specified and as directed.
M&L for Galvanised stay strand wire of size 7/3.15 mm complete all as specified.
Supplying, transporting, erecting and fixing steel tubular swaged poles type 410 SP-55, 11.00 Meter long, complete with cast iron ase plate, final taper plug, bolts, nuts and screws as spedcified including painting with two coats of aluminium paint heat resistant type over one coat of red oxide primer and making 06 Nos bands/Straps with white and black colour (30 cm wide each) synthetic enamel paint at a distance 30 cm from plinth block and numbering of poles with black bitumenous synthetic enamel paint in 2.5 cm height including tarring one coat on steel surface embedded in concerete foundation complete all as specified and directed.
Taking up or down defective/faulty HT underground cable 11000 volts 95 Sqm 3.0 core from the existing trench/duct/pole etc an Re-laying the same in the trenches/duct/pole etc after recitification of defects, including meggering of cable, provn of cable lugs, glands, thimble insulation tape and connectiong up with existing control gears, panels etc as per site requirements, complete all as specified and as directed.
M/S Sky Engineers
VEDA INFRASTRUCTURE
M/S Khan Hussain & Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .