Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.7 LAccepted-AOC 0 0 0 ABABAKPUR KANPUR NAGAR UTTAR PRADESH 209203 UDYAM UP 43 0068644 | KANPUR NAGAR | UTTAR PRADESH | 209203 | 1 | Accepted-AOC Lowest one | |
| 2 | 2₹3.9 L+₹23,277 (6.29%)Rejected-Finance C 4 137 GROUND FLOOR NANGLI VIHAR EXTN NEW DELHI 43 | NEW DELHI | DELHI | 110001 | 2 | Rejected-Finance Higher than the lowest one | |
| 3 | 3₹4.3 L+₹61,016 (16.5%)Rejected-Finance F 2 87 88 ROHINI NORTH WEST DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | 3 | Rejected-Finance Higher than the lowest one |
Tender Value
₹4.4 L
EMD Value
₹8,730
Closing Date
19 Jan 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
RAJPAL MEENA
Office of the Ex. Engineer Electric Najafgarh Zone
Provision of EI and Fans in Malaria office of Ward No.130, Dwarka C under Najafgarh Zone.
2024_SDMC_181373_1
EEE/NGZ/MCD/2023-2024/31
Open Tender
Electrical Works
Item Rate
90 days
Najafgarh Zone
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹8,730
19 Feb 2024
12 Jan 2024
22 Jan 2024
12 Jan 2024
19 Jan 2024
12 Jan 2024
Amount
Approved Item and DSR E&M 2022 Items
OD20896/2023-2024:1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
OD20897/2023-2024:1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
OD20898/2023-2024:1.17.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 6 x 2.5 sq. mm
OD20899/2023-2024:1.17.18 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 9 x 2.5 sq. mm
OD20900/2023-2024:1.17.21 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. mm
OD20901/2023-2024:1.17.24 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 6 x 4 sq. mm
OD20902/2023-2024:1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
OD20903/2023-2024:1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
OD20904/2023-2024:1.50.1 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
OD20906/2023-2024:2.2.1 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16KA, TPMCCB
OD20908/2023-2024:2.3.1 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator):- 6 way , Double door
OD20909/2023-2024:2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator):- 8 way, Double door
OD20910/2023-2024:2.10.1 Supplying and fixing 6A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a)Single pole
OD20911/2023-2024:2.10.3 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCD DB complete with connections, testing and commissioning etc. as required. Double Pole
OD20913/2023-2024:2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
OD20914/2023-2024:5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal/ coke and salt) as required.
OD20915/2023-2024:5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
OD20916/2023-2024:7.5.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
OD20917/2023-2024:7.6.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
OD20918/2023-2024:7.7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 sq.mm (Clamped with 1 mm thick saddle)
OD20919/2023-2024:14.16.1 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
OD20921/2023-2024:19.1 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc as required.
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.1.44:Supply of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
122.2.30.a:SITC of 150W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =150 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
OD20926/2023-2024:SITC of single/ three phase monoblock pump set complete with all accessories workable on 240/415 volts, 50 Hz ac supply (a) 1 HP (0.75 KW) single phase pump set, head from 12-30 metre suction and delivery 25×25 mm.
OD20974/2023-2024:2.14.3 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, tesing and commissioning etc. As required. 63 A
OD20975/2023-2024:Supply of 15'' ( 380 mm ) sweep 1400 rpm exhaust fan heavy duty complete with shutter,blade etc as required
M/s. Rathore Tubewell
Master Electric Store
Bidder Name
Master Electric Store
M/s. Rathore Tubewell
M/s Satyam Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .