Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.0 L+₹53,685 (1.43%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹41.2 L+₹3.7 L (9.92%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹50.0 L
EMD Value
₹99,920
Closing Date
12 Dec 2022, 6:00 pmClosed
GE JAIPUR
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
REPAIR/MAINT OF INTERNAL ELECTRIFICATION WORK AND CABLE NETWORK, TRANSFORMER, LT SWITCH GEARS/ ACB AND CONNECTED ITEMS AT MH UNDER AGE E/M OF GE JAIPUR
2022_MES_563408_1
GE/J-51/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
JAIPUR
As per NIT
5 documents required · 5 mandatory
₹500
GE JAIPUR
₹99,920
Yes
14 Feb 2023
16 Nov 2022
14 Dec 2022
16 Nov 2022
12 Dec 2022
28 Nov 2022
16 Nov 2022 - 27 Nov 2022
Amount
Taking down carefully surface aluminum or copper point wiring including exisitng PVC concealed conduit for (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling rose, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into and including concealed rigid non metallic PVC condiut medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings/fixing accessories and modular metal flush boxes of thickness not less than 1.0 mm and white modular mounting plates with frame for mounting modular switches, sockets as required for 3 pin 16 amps socket outlet point controlled by one switch.
All as per item No. 02 here-in-before but one fan point controlled by one switch.
All as per item No. 2 above but one light point controlled by two, two way switch.
All as per item No. 02 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 02 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No. 02 here-in-before but one bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn into and including existing concealed conduit and terminated in and including modular metal flush boxes for mounting modular cover plate & frame for one socket point 16 Amps controlled by one switch.
M&L for point wiring with 1100 volts grade PVC insulatd FRLS multistranded copper conductor cable 1.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into and including PVC casing-capping not less than 32x16 mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3mm thick phenolic laminated white sheet cover/ PVC gang box for mounting sheet cover for mounting switches, sockets, fan regulators one light point controlled by one switch.
All as per item No. 09 here-in-before but one fan point controlled by one switch.
All as per item No. 09 here-in-before but one light point controlled by two, two way switch.
All as per item No. 09 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 09 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No. 09 here-in-before but one bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulatd FRLS multistranded copper conductor cable 4.0 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 4.0 Sqmm (Green) drawn into and including PVC casing-capping not less than 32x16mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0mm covered with 3mm thick phenlic laminated white sheet cover / PVC Gang box for mounting sheet cover for mounting switches, sockets for one 16 Amps socket outlet point controlled by one switch on independent board.
S&F angle holder, insulated polycarbonate body with back plate complete.
S&F switch piano flush button single pole one way 6 Amp complete.
S&F switch piano flush button single pole one way 16 Amp complete.
S&F flush type, 6 Amp, single pole, two way complete.
S&F bell push, flush type, 6 Amps 240 volts complete.
S&F socket outlet, 2-in-1, 3 pin 6 & 16 Amps flush type compete.
S&F socket outlet, 2-in-1, 3 pin 6 Amps flush type compete.
S&F hum free electronic step fan regulator 120-280 volts of 100 watts capacity including connecting up complete.
S&F in repair switch piano flush button single pole one way 6 Amp complete.
S&F in repair switch piano flush button single pole one way 16 Amp complete.
S&F in repair flush type, 6 Amp, single pole, two way complete.
S&F in repair bell push, flush type, 6 Amps 240 volts complete.
S&F in repair socket outlet, 2-in-1, 3 pin 6 & 16 Amps flush type compete.
S&F in repair socket outlet, 2-in-1, 3 pin 6 Amps flush type compete.
S&F in repair hum free electronic step fan regulator 120-280 volts of 100 watts capacity including connecting up complete.
S&F wire less door bell AC 240 volts, single pole complete.
S&F door bell AC 240 volts, single pole complete.
S&F ceiling rose 3 plates polycarbonate body complete.
S&F modular switch one way 6 amp 1 module all as per specified and directed
Supplying and fixing modular socket 6 - 2/3 pin combined 2 module all as per specified and directed
Supplying and fixing modular switch one way 16 amp 1 module all as per specified and directed
S&F modular socket 6/16 Amps, 2/3pin combined 2 module AC 230 volts.
S&F modular fan regulator 120 watts, 2-module AC 230 Volts.
S&F Modular 2 way 10 A switch 1 Module
S&F Modular bell push, flush type, 6 Amp, 230 Volts complete 2 module all as directed.
Supplying and fixing in repair modular socket 6 - 2/3 pin combined 2 module all as per specified and directed
S&F in repair modular socket 6 Amps, 2/3 pin combined 2 module AC 230 volts.
S&F in repair modular switch 1 way 16 Amps, 230 volts, 1 module.
S&F in repair modular fan regulator 120 watts, 2-module AC 230 Volts.
S&F in repair Modular 2 way 10 A switch 1 Module
Supplying and fixing in repair modular socket 6/16 - 2/3 pin combined 2 module complete all as directed
S&F in repair modular socket 6/16 - 2/3 pin combined 2 module complete all as directed
Supplying and fixing repair modular socket 6 amp 2/3 pin combined 2 module complete all as directed
S&F in repair modular hum free electronic step fan regulator, 120 watt 2 module complete all as directed
S&F modular blanking plate 1 module.
S&F modular whiter cover plate with frame 3 module.
S&F modular whiter cover plate with frame 4 module.
S&F modular whiter cover plate with frame 6 module.
S&F modular whiter cover plate with frame 8 module.
S & F in repair plastic surface boxes 3 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 4 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 6 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 8 moduler for fixing modular switch and socket
Taking down carefully sub main wiring with PVC casing capping/PVC surface conduit and making good disturbed surfaces complete.
M&L for submain wiring with two runs of single core PVC insulated and unsheathed, multistranded FRLS copper conductor of size 4.00 sqmm, LT cable, 1100 volts grade and one run of 4 sqmm single core, multistrand copper conductor (green) as earth continuity conductor drawn into 20 mm dia concealed conduit complete all as specified and directed. NOTE: Two runs of 4 sqmm cable, one run of 4 sqmm cable along with conduit including acessories shall be measured as one running metre of submain wiring.
All as per item No. 60 above but 2x6 Sqmm + 1x6 Sqmm earth in 25mm dia conduit.
All as per item No. 60 above but 2x10 Sqmm + 1x10 Sqmm earth in 25mm dia conduit.
S&F in repair MCBs of 'C' series single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S&F in repair MCBs of 'C' series SPN 10 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S&F in repair MCBs of 'C' series double pole 40-63 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S&F in repair MCBs of 'C' series four pole 63 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S&F in repair MCCB four pole, 125 Amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs as required.
S&F in repair MCCB four pole, 160 Amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs as required.
S&F in repair MCCB 250 amp, 4 pole, 24 KA (Ics=100% Icu) thermally adjustable between 70% to 100% with spreader links on both sides complete all as directed.
S&F in repair MCCB 400 amp, 4 pole, Icu 36 KA (Ics=100% Icu), electronic release and adjustable between 40% to 100% with spreader links on both sides complete all as directed.
S&F in repair MCCB 630 amp, 4 pole, Icu 36 KA (Ics=100% Icu), electronic release and adjustable between 40% to 100% with spreader links on both sides complete all as directed.
S&F in repair LED batten (1.2M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 115 lumen per watt and total power consumption not more than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete.
M&L for repair of satr delta starter including replacement of relay, contactor, timer relay, lugs or as required on site for cpacity 40 HP complete all as directed.
S&F in repair LED batten (0.6M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 1000 lumens at a minimum system efficacy of 115 lumen per watt and total power consumption not more than 10 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete.
S&F LED bulk head fitting 9 watt IP 66 & IK 09 with pressure die cast aluminium housing & polycarbonate diffuser duly pre wired connection with 0.75 Sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable complete.
Supply and fixing in repairs energy efficient recessed mounted LED luminaire suitable for 2'x2' grid ceiling with fullglow fully diffused diffuser and lumen output of 3600 lumens having constant current electronic driver of 36 watt duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable as required.
Supply and fixing LED based Bollard 10 Watt with MS pipe housing with glare free PMHA Difuser , IP 65 hight of light 1 mtr including 1:2:4 concrete PCC (1:2:4 concrete) Base of size 0.30m x 0.30m x 0.45m and connetion wire of suitabe size complete .
M&L for pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer pipe dia 80 mm & inner pipe dia 50 mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical composition Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% burried in ground by digging a bore of 150 mm dia surrounded by soil friendly backfill compound non soluble in water including connection with galvanised earth strip 32 x 6 mm, making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 8 mm dia MS bars 3 Nos both ways with lifting hook made out of 8 mm dia bar and testing on completion to achieve value not more than 2.0 ohm complete. (Note - GI strip size 32x6 mm upto 7.5 m included in the item).
Taking down MCB distribution boards with incoming and outgoing controls any make any capacity after disconnecting complete.
S&F MCB distribution board, tripple pole and neutral, powder coated CRCA steel sheet, suitable for MCCB incomer upto 160 Amps, 4 way 415 volts, degree of protection IP 43, IK-09 with reversible double door, recess mounted, having 250 Amps insulated tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
S&F in repair 20 amp, single pole and neutral, socket outlet, with 2 pole and earth, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 20 amp as required.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 4 ways.
All as per item No 82 above but SPN, 240 volts, 8 ways.
All as per item No 82 above but SPN, 240 volts, 12 ways.
All as per item No 82 above but TPN 415 volts, 4 ways of 160 Amp
S&F MCB distribution board, tripple pole and neutral (VTPN) powder coated CRCA steel sheet suitable for MCCB incomer upto 160 amp, 4 way, 415 volts, degree of protection IP 43 - IK- 09 with reversible double door, recess mounted, having 250 amp insulated tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required
S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm
S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm
S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200mm
Supply & filling distilled water for battery top up all as required.
M&L for disconnection of UPS any capacity any type from supply and servicing of UPS including cleaning of electrical terminal , UPS chamber, battery terminal and connecting again to supply after distilled water top up in battery or as specified by Engineer in charge
Supply and fixing in repair PVC insulated alluminium wire of 6 Sqmm twin core wire at wall/in trench or as specified & directed.
Material and Labour for fixing / repairing loose and disconnected point wiring or diverting the route of point wiring upto a length not exceeding 2.0 metre including required cable of same size and carrier (PVC casing caping or conduit, domestic gang box etc) with fasteners etc and making good disturbed surfaces even and smooth using CM (1:3) as required.
Material and Labour for taking out old buzzer system/ Logic alarm circuit of 8 module including removing / disconnecting panel from wall and repairing buzzer system with indicating light and push switch as required or all connected items complete all as directed
Supply and fixing of high efficiency LED post light 15 watt ,landscape luminaire complete or as specified and directed by Engr In charge . Make Havells cat ref No CORALMINIPT15WLED757PSYMTOPC or Crompton cat part no. CROMA8252LED9W or Bajaj cat part no. Tulip BGBOM 9WLED as approved by GE.
Supply and fixing of greenline high efficiency LED building light luminaire 25 watt complete with drive, pressure die cast aluminium housing, UV stablized polycarbonates cover, in built power unit, IP 65 protection including mounting bracket made of 25 mm GI pipe, medium grade ISI marked not less then 1.2 m bend in shape with two number clamps, nuts, bolts, washeres as required.
Supply and fixing ceiling fan 1200mm sweep 50 Hz AC 230 votls, 5 star rated in white colour with bldc fan motor, blade set, 0.45 mtr down rod, canopy set, rubber reel including 0.5 Sqmm three core PVC insulated flexible copper conductor multistranded wire from fan motor to ceiling and writing MES No. on fan body as required.
S&F in repair AC film capacitor 2.5 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete.
M&L for Labour for taking out old unservicable LT cable of any size from trenches, wall, pipe etc complete all as directed.
S&F 1100 volt grade heavy duty XLPE insulated armoured cable with aluminum conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 400 Sqmm nominal cross section 3.5 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed.
All as per Item No. 100 above but of size 300 Sqmm nominal cross section 3.5 core.
All as per Item No. 100 above but of size 240 Sqmm nominal cross section 3.5 core.
All as per Item No. 100 above but of size 185 Sqmm nominal cross section 3.5 core
All as per Item No. 100 above but of size 95 Sqmm nominal cross section 3.5 core
All as per Item No. 100 above but of size 70 Sqmm nominal cross section 3.5 core
All as per Item No. 100 above but of size 50 Sqmm nominal cross section 3.5 core
All as per Item No. 100 above but of size 35 Sqmm nominal cross section 3.5 core
All as per Item No. 100 above but of size 16 Sqmm nominal cross section 4 core
S&F in repair galvanised mild steel tubes "light grade " of 80 mm bore (ISI marked) with all fitting( ISI marked) and fixed to walls and ceilings or laid in floors/ trenches and under road, complete all as specified and directed.
All as per Item No 109 above but 100 mm size.
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in soft/ loose soil complete all as specified and directed
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point.
M&L for sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying including gently punning around cable complete all as specified in SSR Part-I and directed.
M&L for bricks well burnt sub class 'B' laid in trenches flat with width equal to length of brick for cable protection laid across the cable complete all as specified and directed.
Material and labour for replacement of digital voltmeter for suitable range of 0-440V including wiring with copper conductor cable of 1 Sqmm all as specified and as directed by Engineer-in-Charge.
Material and labour for replacement of digital ammeter of range 0-100 Amp including wiring with copper conductor cable of 1 Sqmm all as specified and as directed by Engineer-in-Charge.
Material and labour for rewiring of LT panel/feeder using 1 Sqmm copper wire of 10-12 meter including replacemnt of wornout parts , nut , bolts,backlite surface and cleaning of burnt/rusted surface/ all as specified and as directed by Engineer-in-Charge.
M&L for preparation of the old painted surfaces of feeder piller boxes/panels/boards / transformer of any size any description and in any position including removal of faded & deteriorated paint eaither by hand scrapping or by blow lamps, applying necessary filler coat and scrspping as required and applying two coats of synthetic enamelled paint (grey in colour) with using spray machine on old prepared surfaces complete all as spcified and as directed by Engineer- in Charge.
Supply and fixing in repair of spreder links of capacity 200 to 400 Amps in existing LT panel/ etc including provision of insulation tape RYB in colour and holes, nuts & bolts etc
Supply and fixing in repair of spreder links of capacity 100 to 200 Amps in existing LT panel/ etc including provision of insulation tape RYB in colour and holes, nuts & bolts etc
Supply and fixing in repair Copper bus bar 800 Amp capacity in existing LT panel/feeder piller /Transformer etc including provision of insulation tape RYB in colour and holes, nuts & bolts etc
Supply and fixing in repair Copper bus bar 630 Amp capacity in existing LT panel/feeder piller etc including provision of insulation tape RYB in colour and holes, nuts & bolts etc
Supply and fixing in repair Copper bus bar 400 Amp capacity in existing LT panel/feeder piller etc including provision of insulation tape RYB in colour and holes, nuts & bolts etc
Supply and fixing in repair danger notice plate of size 20x15cm made out of MS sheet 1.6 mm thick, vitreous enameled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts, nuts on LT poles complete all as directed by Engineer-in-Charge.
M&L for 40mm gravel stone, deposited, spread and leveled in layers not exc 15 cm thick, rammed to a true surface, under 2/4 pole structure and around the 2/4 pole structure & outdoor electrical installations, complete all as specified and as directed.
M&L for cable jointing kit for upto 1.1 KV (Earthed) grade cable for indoorheat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of following size :- 25 sqmm 3.5 core
35 sqmm 3.5 core
51 sqmm 3.5 core
70 to 120 sqmm 3.5 core
240 to 300 sqmm 3.5 core
400 sqmm 3.5 core
M&L for cabletermination kit for upto 1.1 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of following size :- 50 sqmm 3.5 core
70 to 120 sqmm 3.5 core
240 to 300 sqmm 3.5 core
400 sqmm 3.5 core
M& L for shifting of existing LT Panel disconnecting existing electrical connection from MCCBs/MCB/Bus bar , taking out required length from loop and reconnecting with electrical connection at new location including breaking / cutting existing PCC foundation and fixed at new location over and including foundation of size 0.6m x 1.0m x 0.30m in PCC 1:3:6 using 20 mm graded stone aggregate incluting paitning with danger sign on Panel not beyond 300 mtr or as specifiied by the EIC
M&L in repair earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6.0mm buried directly in ground, vertically to depth not less than 2.25mtr below normal ground level with top edge of the earth plate at depth not less than 1.5 metre below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI strip of size 32x6mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe medium grade 20mm bore for watering, 40mm bore GI pipe medium grade for protection of GI strip upto test point including providing funnel and wire mesh GI frame and 10cm thick suitably reinforced RCC pit cover, PCC chamber pit with PCC (1:3:6) type C2 using 40mm graded stone aggregates complete including excavation and earth work in any type of strata, disposal of surplus soil to a distance not exceeding 50 mtr, all as specified ans shown in Electrical plate No. 3 of SSR Part-1, PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit including testing on completion complete. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
M&L for Servicing/repairing of AMF system built in with DG set of any capacity including cleaning resetting / adjustment of relays, calibration of time delay relays, checking and replacing u/s diodes, resistors etc as required.
Supply and fix 4 pole Power contactor MCX 43, 240 V ,400 Amp alongwith complete new wiring in existing panel .
S&F in repair ONLINE Changeover of cap 400 amp, TPN, front handle type or as sprcified
S&F in repair ONLINE Changeover of cap 200 amp, TPN, front handle type or as sprcified
M&L for serving of vaccum pump & motar of capacity 3HP including oil change, greasing, spare parts replacement as required
S&F thermoplastic, IP65 cable junction box of size 200 x 160 x 98 mm with metric knockouts on all sides for cable entry or Secure duly fitted with followings:- (a) DIN Rail (35 mm) - 1 No (b) ELMEX or equivalent make connector of 10 sqmm - 4 Nos (c) ELMEX or equivalent make end plate - 1 No (d) ELMEX or equivalent make end clamps - 2 Nos (e) MCB SP 6 amp, 10 KA, 'C' series - 1 No
S&F bollard LED garden light 8 watt 1 Mtr hight complete with required earth work, including fasteners, nuts, bolts, washers, copper connecting cable & PCC (1:2:4) type B 1 using 20 mm graded stone aggregate (size 0.40 m x 0.30 m x 0.45 m) complete.
Supply and fix 3 pole contactor MCX 25, suitable for 415 volt alongwith complete new wiring in existing panel .
Supply and fix 3 pole contactor MCX 45, suitable for 415 volt alongwith complete new wiring in existing panel .
Supply and fix 3 pole contactor MCX A2, suitable for 415 volt alongwith complete new wiring in existing panel .
Supply and fix timer relay suitable for 230 /415 volt alongwith complete new wiring in existing panel .
M&L for of wall mounted 6 Way bus bar chamber connsisting with bus bar 3 phase and neutral 4 Nos 200 Amp fixed on insulators including fixing in wall or as specififed by EIC
S& F in repair integral LED flood light 100 W 3000 K with a nominal system lumes output of 7200 lumens and a minimum system efficacy of 90 lumes/ watt. The luminaire shall have rated system lifetime of 50,000 burning hours before reaching at L70. The liminarire should have cool white colour temperature (CCT > 3000K) and a CRI > 70. The luminair shall meet IP 66 rating & IK05 rating with THD <20% and PF >90. The luminaire housing should be made of pressure die cast aluminium with a flat glass optical cover. the total power consumption should not exceed 100W including driver complete all as directed.
M&L for cross arms, bracings, supports, clamp and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of paint complete.
S&F in repair street light fittings, installation, testing and commissioning of integral driver LED street light with a nominal system lumen output of 7200 lumens and a minimum system efficacy of 90 lumen/watt. The luminaire shall have rated system lifetime of 50,000 burning hours before reaching at L70. The luminaire should have cool white colour temperature (CCT > 5000K) and a CRI >70. The luminaire shall meet IP 66 rating & IK05 rating with THD < 20% and PF > 0.9. The luminaire housing should be made of pressure die cast aluminium with a flat glass optical cover. The total power consumption should not exceed 72W including driver.
M&L for Painting of street light poles 8.5 m / 9.0 long including street light brackets/clamps etc with best quality aluminium paint, making alternate black & white colour bands of 30 cms width upto a height of 1.5 m from pole coping with synthetic enamelled paint and writing pole numbers in black colour on yellow base complete.
M&L for of bus bar chamber pedestal type of size 75 cm x 60 cm x 40 cm out door dust & vermin proof front opening made out of 2.0mm thick MS sheet duly painted and consisting with aluminium bus bar 3 phase and neutral 4 Nos 400 Amp fixed on insulators and one MCCB TPN 200 Amp, 25 KA rupturing capacity including necessary fixed in PCC 1:3:6 using 20 mm graded stone aggregate including danger plate etc complete.
S&F in repair transformer breather assembly oil seal type made of heavy duty transparent plastic body having top & bottom cover made of aluminium or mild steel of capacity 500 grams filled with silica gel complete.
M&L for topping up of deficient oil to maintain reqd level of transformers with filtered and dehydrated transformer oil (conforming to IS: 335) and to withstand dielectric strength 60 KV or above (when tested with 2.5 mm gap electrode) complete.
S&F in repair HV brass set stem of 12 KV grade suitable for transformer of capacitie 200 KVA to 400 KVA as required.
S&F in repair LV brass set stem of 1.1 KV grade suitable for transformer of capacities 200 KVA to 400 KVA as required.
M&L for Dehydration / Filtration of transformer Oil of existing transformer install at site with portable plant to improve the dielectric strength 40 to 60 KV during filling after initial filtration including testing of dielectric strength after dehydration at site.
M&L for opening up the top cover of transformer of any capacity for checking the conditions to carryout repairs at site, including draining out oil from the transformer in suitable containers (containers to be provided by the contractor) and repair the transformer with replacement of parts where required, check the lead connection from winding to bushing rods including necessary soldering/jointing etc and refilling the dehydrated oil after complete repair, making all connections and testing on full load complete all as specified & as directed. Notes :- (i) Labour component required for the replacement of unserviceable parts shall deemed to be included in the unit rate quoted against this item. (ii) Major parts where required to be replaced shall be measured and paid for separately as ‘Supply only’ under relevant items of this Schedule. (iii) All T&P and minor parts such as nuts, bolts, washers, insulating material, copper wire for delta connection, etc. shall be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item. (iv) Dehydration of existing transformer oil and new transformer oil required for topping up shall be measured and paid for separately under relevant items of this Schedule.
M&L for HT bushing complete with double check nuts, washers, gasket set for transformer of capacity 200 KVA complete all as specified and as directed.
M&L for HT bushing complete with double check nuts, washers, gasket set for transformer of capacity 315 KVA to 400 KVA complete all as specified and as directed.
M&L for LT bushing with brass spindle complete with double check nuts, insulation washers for transformer of capacity 200 KVA complete all as specified and as directed.
M&L for LT bushing with brass spindle complete with double check nuts, insulation washers for transformer of capacity 315 to 400 KVA complete all as specified and as directed.
M&L for Gasket set made of rubberised cork/neoprene material for transformer of capacity 200 KVA complete all as specified and as directed.
M&L for Gasket set made of rubberised cork/neoprene material for transformer of capacity 315 KVA to 400 KVA complete all as specified and as directed.
M&L for disconnecting existing transformer step down 11 KV/0.433 KV indoor/outdoor type of capacity 200 KVA, taking down from site of installation, opening the top cover of transformer, draining out transformer oil from the housing in suitable containers (containers to be provided by the contractor) and inspecting / assessing the defective / burnt parts, core assembly, etc in the presence of Engineer-in-Charge, shifting the transformer to workshop for repair including loading, unloading, transportation etc, cleaning and making good surface including internal cleaning, removing sludge, etc and painting with one coat of zinc chromate paint to the inner side of the transformer body and one coat of synthetic enamel paint (grey) on outer body of transformer by using spray machine after cleaning & removing oil spots etc, carrying out necessary repair to transformer at workshop, re-assembling, shifting back to site, reinstalling, re-connecting, re-commissioning the transformer and testing at site on full load, complete all as specified and as directed.
All as per item no 160 but for Transformer capacity 315 to 400 KVA Notes for serial item No. 160.00 & 161.00 :- (i) Labour component required for the replacement of unserviceable parts shall deemed to be included in the unit rate quoted against this item. (ii) HT/LT coils where required shall be measured and paid for separately as ‘Supply only’ under relevant items of this Schedule. (iii) All minor parts such as nuts, bolts, washers, insulating material, copper wire for delta connection, etc. shall be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item. (iv) Testing of transformer shall be arranged by the contractor for Type Test & Routine Test which shall be carried out in the presence of Engineer-in-Charge and contractor shall submit test certificates to this effect before processing the RAR for payment.
Supply only the following spares/items for repair/replacement to transformers under serial item No. 162.01 to 162.02 here-in-before :-
LT coil made out of super enameled copper conductor wire of suitable gauge and size as per requirement for distribution transformer complete all as directed.
HT coil made out of super enameled copper conductor wire of suitable gauge and size as per requirement for distribution transformer complete all as directed.
S&F 11000 volt grade heavy duty HT XLPE cable with PVC insulated aluminum conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 120 Sqmm nominal cross section 3 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm 3 core.
Material and labour for fault investigation of HT /LT electic supply line of any size with fault lacator machine for LT/HT line including rectification of fault with cutting/disconnecting of cable and jointing with suitable size of cable jointing kit ,excavation or as speciffied and as directed.
Surface dressing not exc 15cm deep in soft/loose soil and clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30 cm girth (measured one metre above ground level) surrounding Transformers, LT Panels, 02 Pole structures, 04 Pole Structures, etc at various sub stations / E&M installations and removing rubbish upto a distance exc 200m & not exc 250m outside the periphery of the area under clearance complete all as specified & as directed. (Note : Contractor shall maintain the area clean for entire contract period and measured and paid onece only)
Supply and fix in repair DOL starter,5HP(MU1) suitable for upto 10 HP 3 phase, 415 volts AC supply motor complete all as specified and directed. Make:- L&T Cat part No SS-95647 or equivalent
Schedule of Credit
M/s Radhey Enterprises
SHREE BHAGWATI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .