Executive Engineer (A-M) Burdwan (A-M) Division
Kalna Road, Near Agril Farm, Purba Bardhaman- 713101
Construction of Jotsriram New Handed Over Major RLI Scheme (Electrified) at Mouza-Jotsriram, Block-Jamalpur, JL No.- 37, Plot No-1151 in the District of Purba Bardhaman, under Memari (A-M) Sub-Div under EE(A-M) Burdwan (A-M) Div under Core sector.
2026_WRDD_999358_1
WBWRDD EEAM BDN eNIT-43 CS 2025-26
Open Tender
Project Work
90 days
Jotsriram RLI, Jamalpur Block
Please refer Tender documents.
4 documents required · 4 mandatory
₹1.9 L
27 Feb 2026
5 Feb 2026
23 Feb 2026
5 Feb 2026
19 Feb 2026
5 Feb 2026
Procurement of UPVC; M.S. / C.I. ; ERW / GI pipes etc Materials and other Fittings etc. ( Please see the details in Sheet Material Procurement)
Laying of Water Transmission Arrangment (WTA). ( Please see the details in Sheet WTA)
Construction of New Twin Hull Barge. (Please see the details in Sheet Barge)
Internal Wiring. ( Please see the details in Sheet IW)
Cost of Energisation. (Please see the details in Sheet Energ)
Cost of Water Users Association Formation(WUA). (Please see the details in Sheet WUA)
BoQ_Ver3.0
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Procurement of UPVC : M.S/C.I; ERW /GI pipes etc Materialsand other Fittings etc. 315 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
200 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
140 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
140 mm dia P.V.C. Pipe(Cl-II) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
200 mm dia P.V.C. Equal Tee as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
140 mm dia P.V.C. Equal Tee as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
315 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
200 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
160 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
160 X 140 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
200 X 140 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
200 X 60º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
140 X 90º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
140 X 60º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
200 mm dia P.V.C. End Cap(Cl-III) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-III (0.60 MPA)
140 mm dia P.V.C. End Cap(Cl-III) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-III (0.60 MPA)
315 mm dia P.V.C.Extra Coupler (Class-II) IS 10124:2009 with latest amendments and shall be duly marked with ISI certification Mark and shall be of Class-II (0.4MPA)
200 mm dia P.V.C.Extra Coupler (Class-II) IS 10124:2009 with latest amendments and shall be duly marked with ISI certification Mark and shall be of Class-II (0.4MPA)
140 mm dia P.V.C.Extra Coupler (Class-II) IS 10124:2009 with latest amendments and shall be duly marked with ISI certification Mark and shall be of Class-II (0.4MPA)
Extra Solvent Cement as per I.S. 14182-1994 with latest amendments
M.S. ACCESSORIES 150 mm dia 90º G.I Bend (both end flanged), ISI marked-IS-1239/II, Galv- IS 4736
150 mm dia 90º G.I Bend (both end flanged) long bend With priming arrangement, ISI marked-IS-1239/II, Galv- IS 4736
150 mm.dia Galv. MS Flanged Pipe ISI marked- IS- 1239, Galv- IS 4736 (4.8mm)
80mm dia screwed at one end & st flanged at other 3m long (top)
150 mm dia C.I. Sluice Valve with hand wheel, ISI marked- IS 14846
150 mm dia (type-C) Alfa Alfa Valve (nipple type) with handwheel 01 no. for 04 nos valve, as per IS 210/2009 (As per appvd. existing drawing)
150 mm dia P.V.C.Flexible Hose pipe, ISI marked - IS 15625
Electro Motor Pump Set and Elec. Accessories : 25 H.P.Electro Motor Pump set having capacity of 200 cubic meter per hour discharge at 24 meter total head. The Motor shall be designed for operation at 415V(±6%) 3 Phase,50 cycles per sec(±3%), A.C supply 1500 rpm. The Motor shall be TEFC ISI marked as per IS: 325/1996 with latest amendments thereof. The Pump of size ( 150X150mm) shall be horizontal, single stage ,split casing type duly ISI marked as per IS-6595/1993 with latest amendments thereof Pump should be directly coupled with Motor and mounted on a common fabricated M.S.Base frame.
3 phase electromagnetic Star-Delta starters for 25 HP motor (As per tech. spec.)
200 A Busbar Chambers (As per appvd. Existing dwg) (As per tech. spec.)
SWITCH FUSE UNIT, ISI MARKED, IS 60947 200 A Switch Fuse Unit TPN (Conforming to IS) (As per tech. spec.)
63 A Switch Fuse Unit TPN (As per tech. spec.)
Field Level Materials Round strand Galvanized Steel wire rope.Diameter: 19mm, Core IWRC (Steel Core). Length of Coil 25Meter. Make Usha Martin Ltd/ Bharat Wire Ropes Limited/or equivalent (Specification IS 2266 2002 or revised thereof: Duly ISI Marked)
Supply & Transportation of 150 mm dia MS Heavy Duty Hose Clamp fitted with bolts & nuts (2 sets) 2.5 mm thick, 45 mm width. One coat of Black Japan.
Supply & Transportation of 150 mm dia C.I. Foot valve, flanged end & swing type as per IS 4038/1986 with latest amendment duly ISI marked.The disc face will be made of leather and strainer made of galvanized steel.The Valves shall be tested for (closed end test) against Hydrostatic test requirement.
Supply & Transportation of 5mm thick 150 mm dia Foot Valve Leather Washer(Table-17) best quality brand (Imperial/Techno/Burhani).
Supply & Transportation of 150 mm dia C.I. Combined Tail Piece both side groved.
Supply & Transportation of 150 mm dia C.I. Tail Piece with flange adopter one side grooved overall length(175+/-15) mm and other end flanged(23 mm flange thk) with 7 nos. grooves as Per IS:1538 and drilled as Per Table-17 of IS:6392.
Supply & Transportation Foundation Bolt for Electro-Motor Pump set foundation and manufactured from 20 mm nominal diameter MS Rod as per IS:2062/1992. Total length of the Bolt is 375 ±10 mm having welded head 80±10 mm in length and 20 mm in nominal diameter nut and 2 nos. washer, The average weight of such bolt to be 1.5 kg. per bolt with tolerance in weight of each bolt @ ±10%.
Supply and transport of Rubber Insertion 5 mm thick with proper reinforcement 2 ply conforming to IS 638/79 with ISI Mark with latest amendmends suitable for raised surface of MS flange as per IS 6392/71 (Table 5, 11 & 17).
300 mm dia Rubber Insertion (Table No.11)
300 mm dia Rubber Insertion (Table No.5)
200 mm dia Rubber Insertion (Table No.11)
200 mm dia Rubber Insertion (Table No.5)
150 mm dia Rubber Insertion (Table No.17)
150 mm dia Rubber Insertion (Table No.5)
80 mm dia Rubber Insertion (Table No.17)
Supply & Transportation of MS Hexagonal Head Nuts and Bolts conforming to IS 1363(Part-I)/1992 of product grade C with latest amendmends for Bolts & IS 1363(Part-3)/1992 of product Grade-C with latest amendments for Nuts properties /Class for Bolt-4.6 & for Nut-4.5. Finish: ISI marked.
a) M 16 mm X 65 mm.
b) M 16 mm X 80 mm.
c) M 16 mm x 50 mm.
d) M 20 mm X 80 mm.
e) M 20 mm X 100 mm.
Supply & transportation of GI MS Shore Manifold made of 350 mm dia Galvanised MS ERW Pipe, 1.5 mtr. long having 2 numbers of 150 mm dia inlet and 3 numbers of 150 mm dia Outlet, all ends flange welded, GI MS ERW Pipe conforming to IS:1239(Part-I), Medium and Galvanised MS Flange conforming to IS: 6392/71 (Table-17). Duly ISI marked. (As per drawing & tech. spec.)
Supply & transportation of GI MS Shore Manifold made of 350 mm dia Galvanised MS ERW Pipe, 1 mtr. long having 1 number of 300(NB) mm dia inlet and 3 numbers of 150 mm dia Outlet, all ends flange welded, GI MS ERW Pipe conforming to IS:1239(Part-I), Medium and Galvanised MS Flange conforming to IS: 6392/71 (Table-17). Duly ISI marked. (As per drawing & tech. spec.)
Supply & transportation of GI MS Shore Manifold made of 350 mm dia Galvanised MS ERW Pipe, 1 mtr. long having 2 numbers of 150(NB) mm dia inlet and 1 number of 300(NB) mm dia Outlet, all ends flange welded, GI MS ERW Pipe conforming to IS:1239(Part-I), Medium and Galvanised MS Flange conforming to IS: 6392/71 (Table-17). Duly ISI marked. (As per drawing & tech. spec.)
Supply & transportation of 300(NB) mm dia 90 degree GI MS bend (one end flange welded and another end short piece with end ring welded for free backing flange). Bend shall be as per IS 1239 (part- II)/2011 and flange conforming to IS 6392/1971 (Table-17) with raised surface. Duly ISI marked. (As per approved drawing & tech. spec.)
Supply & transportation of 300(NB) mm dia 90 degree GI MS bend (one end flange welded and another end short piece with end flange welded). Bend shall be as per IS 1239 (part- II)/2011 and flange conforming to IS 6392/1971 (Table-17) with raised surface. Duly ISI marked. (As per approved drawing & tech. spec.)
200X150 MS Flanged reducer with both end flanged, ISI marked
MS Reducer 150X300 mm with both end flange welded and Flange ISI marked IS 6392 with latest amendment.
Total =
Say Rs.
Sixty Lakh Seventy Five Thousand Seven Hundred & Sixty Only
BoQ_Ver3.0
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Laying of Water Transmission Arrangment (WTA).
Earth work in excavation of field trenches as per designed section & alignment for laying of pipe lines (PVC, RCC, ACP etc) upto a depth of 1500 mm in all sorts of soils including removing, spreading or stacking extra earth as directed.The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom as required complete. [Vide Chapter no.6.2.10, item no. 1 of WRDD Schedule ]
Earth work in filling in trenches after laying of pipe lines (PVC, RCC, ACP etc) or plinth with good earth, in layers not exceeding 225 mm. including watering and ramming etc. layer by layer complete. (Payment will be made on the basis of measurement of finished quantity of work).[Vide Chapter no.6.2.10, item no. 2 of WRDD Schedule ]
Laying of UPVC pipes of different diameters within field trenches in curve/ straight line including using UPVC fittings, Viz. Horizontal and Vertical Bends, riser pipes, Tee, Reducer etc.and making leak proof joints with couplers after roghening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by deptt.) all complete as per direction of Engineer-In- charge. [Vide Chapter no.6.2.20, item no. 1(A) of WRDD Schedule]
i) 315 mm.OD.
ii)200 mm OD
iii) 140 mm. OD.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. [Vide Page no.1, item no. 2(a) of PWD Schedule] (a) Depth of excavation not exceeding 1,500 mm.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) [Vide Page no.1, item no. 3(a) of PWD Schedule] (a) With earth obtained from excavation of foundation.
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. [Vide Page no.14, item no. 1 of PWD Schedule 3rd CORRIGENDA & ADDENDA]
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water, ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity) [Vide Page no.2, item no. 4(A) of PWD Schedule]
Ordinary Cement Concrete (mix 1:2:4) with graded stone chips (20 mm. normal size) excluding shuttering and reinforcement, if any, in ground floor. as per relevent IS Code. a) Pakur Variety [Vide Page no.24, item no. 4(A) of PWD Schedule 3rd CORRIGENDA & ADDENDA]
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) (a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-in-charge. [Vide Page no.42, item no. 36(A) of PWD Schedule]
Cost of Boring through any type of soil and auger boring (horizontal) with water jet system including hire charges of machine, tools and plants , all complete with all labour and supply of water etc. as per specification and direction of EIC. [ Vide PHE It-15 SE Central Circle (E)] (a) For above 150 mm dia upto 200 mm dia
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation & plinth [Vide Page no.15, item no. 8(a) of PWD Schedule 3rd CORRIGENDA & ADDENDA]
125 mm. thick brickwork with 1st class bricks in cement mortar (1 : 4) in ground floor. [Vide Page no.16, item no. 16 of PWD Schedule 3rd CORRIGENDA & ADDENDA]
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints, including throating, nosing and drip course, scaffolding/staging where necessary (ground floor).[Excluding cost of chipping over concrete surface] [Vide Page no.189, item no. 1 of PWD Schedule 3rd CORRIGENDA & ADDENDA]
(i) with (1:4) cement mortar, (b) 15 mm. thick plaster
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m. [Vide Page no.192, item no. 15 of PWD Schedule]
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge. [Vide Chapter no.6.2, item no. 2 of WRDD Schedule ]
(i)(a) 150 mm. dia. ERW pipe.(GI Pipe)
Installation / Erection of SurgeTank / Shore manifold (to be supplied from Deptt. free of cost) over a rigid base of ordinary cement concrete (1:2:4) with graded stone chips (20mm. nominal size) of pakur varity of 1250 mm X 1250 mm X 150 mm. over a single layer of brick flat soling and embedding the legs of the surge tank/shore manifold within the concrete base including cost of all materials and labour and as per direction of Engineer-in-Charge. [Vide Chapter no.6.2.30, item no. 5 of WRDD Schedule ]
Labour charges for fitting, fixing 150 mm. Dia. Alfa-AIfa valve with 160mm. dia. P.V.C. riser pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C. End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete. [Vide Chapter no.6.2, item no. 3 of WRDD Schedule ]
Supplying, fitting and fixing including transportation of sign board for identifing the exact location of Major RLI scheme (one at road side and other at site) the board will be made of 3 mm thick MS plate of size 300 mm × 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soiling. This will include materials and labour complete as per drawing and direction of EIC. [Vide Chapter no.6.2, item no. 17 of WRDD Schedule ]
Supplying 1 mtr x 0.6 m x 24 swg MS board contaning list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house. [Vide Chapter no.6.2, item no. 18 of WRDD Schedule ]
Installation of Electro-Motor Pumping set of any make / brand and for RLI scheme on pump foundation over SAL sleeper (to be supplied departmentally) by fixing nuts and bolts and making connection of suction hose and foot valve with necessary fittings at the inlet end of the water pump and fitting fixing of 90° M S priming bend, sluice valve and delivery hose with all necessary fittings at the delivery end of the water pump, duly connected with the pipe line, maintaining proper alignment and level including cutting holes on the wall of the pump house where necessary, mending good damages after completion of the works as per direction of Engineer-in-charge. (Pump set and all accessories will be supplied departmentally). c) For Majori R.L.I. Scheme. [Vide Chapter no.6.2, item no. 15 of WRDD Schedule ]
Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entire pipe line net work for at least 4 (four) hours by running the departmental Deasel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-in-Charge. i) For Major R.L.I. [Vide Chapter no.6.2, item no. 7 (b) (i) of WRDD Schedule ]
Add 4% carriage except item no. 2.01,2.02,2.04, 2.05 & 2.21
Sub-Total
Add GST @18%
Cost of civil works excluding Labour welfare cess
Add Labour welfare cess @ 1%
Grand Total
Twelve Lakh Seventy Eight Thousand Eight Hundred & Eighteen Only
BoQ_Ver3.0
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Fabrication of New Twin Hull Barge (Size: 16 ft 16 inch × 9 ft × 3ft )
Patch/Doubling works complete with 5 mm M.S. plate including welding, gas cutting, fitting, fixing complete.
(a) Cost of 5 mm M.S. plate including wastage due to cutting, including labour charges for straightening fitting, fixing in position. WRDD (Chapter 7.0, Item. 4 (a)).
(b) Gas cutting to required size of 5 mm thick M.S. plate, M.S. channel, angle etc. including labour charges, hire charges for all tools and plants. WRDD (Chapter 7.0, Item. 4 (b)).
(c) Electric welding charges of 5 mm M.S. plate M.S. channels etc. and other member of the barge including hiring charges of all tools and plants. WRDD (Chapter 7.0, Item. 4 (c)).
Supply, fitting, fixing complete with fastner :
(a) Galvanized corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10 mm dia. J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm end lap and one corrugation minimum side lap with 0.60 mm thick sheet in roof. ( payment to be made on area of finished work),(GCI sheet to be supplied by contractor). WRDD (Chapter 7.0, Item. 5 (a)).
(b) Galvanized iron sheet ridging fitted with necessary bolts,screws, washers etc. complete (225 mm. end lapping) with 0.60 mm sheets, 300 mm lapping each way. WRDD (Chapter 7.0, Item. 5 (b)).
Supplying, fitting and fixing of B.R.C. net (75 mm × 25 mm × 10 swg) with nuts and bolts of the barge including gas cutting etc. WRDD (Chapter 7.0, Item. 6 ).
Supplying 1.5 mm (16 SWG) M.S. sheet fitted and fixed on one or both faces of M.S. bar etc. with point welding not more than 150 mm apart complete in all respect and including cost of labour and materials as per direction of Engineer-in-Charge. WRDD (Chapter 7.0, Item. 7 ).
Supplying, fitting & fixing of M.S. angle (Size : 45 mm × 45 mm × 6 mm) including gas cutting etc. WRDD (Chapter 7.0, Item. 8 (a)).
Supplying, fitting & fixing of M.S. flat bar 40mm × 6 mm for straightening the B.R.C. net including gas cutting etc. WRDD (Chapter 7.0, Item. 9 ).
Supplying, fitting & fixing of B.R.C. net by (3/8)" × 2" M.S. bolts & nuts with washers with M.S. angles M.S. flat, M.S. sheets etc. and other members of the barge. WRDD (Chapter 7.0, Item. 10 ).
Supplying, fitting & fixing of B.R.C. net by (3/8)" × 11/2" M.S. bolts & nuts with washers with M.S. angles M.S. flat, M.S. sheets etc. and other members of the barge. WRDD (Chapter 7.0, Item. 10 ).
Supplying, fitting & fixing of B.R.C. net by (1/2)" × 11/2" M.S. bolts & nuts with washers with M.S. angles M.S. flat, M.S. sheets etc. and other members of the barge. WRDD (Chapter 7.0, Item. 10 ).
Supplying, fitting & fixing of B.R.C. net by (5/8)" × 1 1/2" M.S. bolts & nuts with washers with M.S. angles M.S. flat, M.S. sheets etc. and other members of the barge. WRDD (Chapter 7.0, Item. 10 ).
(a) Supplying, fitting and fixing of M.S. channel (Size 75 mm × 40 mm × 6 mm) for base of manhole cover including gas cutting. WRDD (Chapter 7.0, Item. 11 (a)).
(b) Drilling charges 12 mm dia hole for manhole cover plate and M.S. channel base. WRDD (Chapter 7.0, Item. 11 (b)).
(c) Supplying, fitting and fixing of (1/16)" thickness rubber insertion sheet with 12 nos. drilling hole for water tight arrangement of manhole cover. WRDD (Chapter 7.0, Item. 11 (c)).
Chipping, scraping wire brushing and cleaning of the painted surface for keel, hull, frame, superstructure deck, fender both inside and outside as per direction of the Engineer-in-Charge. WRDD (Chapter 7.0, Item. 12 (a)).
Cost of Doors (6'-0" × 3'-0") by point welding with B.R.C. net (75 mm × 25 mm × 10 SWG), 49 mm × 6 mm M.S. flat bar, 6" hings 4 pcs. 10 " hasp bolts - 2 nos. etc. complete as per direction of Engineer-in-Charge. WRDD (Chapter 7.0, Item. 13 (a)).
Supply, fitting, fixing complete of 1" dia MS Rod for Plate welding of MS Plates of the Barge. WRDD (Chapter 7.0, Item. 13 (b)).
Supplying, fitting & fixing of 25 mm G. I. Pipe for tie rod of the Barge. WRDD (Chapter 7.0, Item. 8 (d)).
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. WRDD (Chapter 7.0, Item. 14 (a)).
(b) Painting two coats (with any shade except white) with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on steel surface or other metal surface with super gloss (hi-gloss). WRDD (Chapter 7.0, Item. 14 (b) (a) (ii)).
Transportation charges for carrying of all the materials, working devices etc. upto the scheme and back. WRDD (Chapter 7.0, Item. 15).
Dockyard hired Charges for approx. 45 days including electricity charges. (As per approved rate of the S.E. (A-M) Burdwan (A-M) Crcle.
Sub-Total
Add GST @18%
Cost of civil works excluding Labour welfare cess
Add Labour welfare cess @ 1%
Cost of civil works including Labour welfare cess
Say Rs.
Eleven Lakh Eighty One Thousand Four Hundred & Seventy Eight Only
BoQ_Ver3.0
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Internal Wiring (IW).
Supplying, fitting & fixing 350 mm x 250 mm x 25 mm size Wooden Plank on wall (for fitting & fixing of electrial equipments as necessary on the plank).(WRDD schedule 2018 Page-42, Chapter 9, Item no-8)
Supplying,fitting & fixing of M.S. angle (Size: 50 mm x 50 mm x 6 mm) including gas cutting etc. (WRDD Revised schedule dt. 04.08.21, Page-4, Chapter-7, item no-8(b))
Fixing only TPN switch fuse units in Sheet Steel enclosure with HRC fuses on angle iron frame on wall for 32A to 400A . (200 AMP) [Ref.- PWD SOR 2017 Ele.Sh. Item no.- 2 Page-C-1 ]
Meter loop connection with 1.1 K.v. Gr. 3-1/2 core / 4 core 10 sq mm to 50 Sq mm. aluminium P.V.C./XLPE insulated & sheathed and armoured Aluminium/Copper Cable from Meter to incomming TPN Main Switch /Terminal.(Brand: Gloster/Havells/Finolex) (d) For MAJOR RLI Scheme (i) 50 Sqmm 3-1/2 Core Aluminium Cable [Ref:-WRIDD SOR 2018 item no -13{d(i) page no -42]
Fixing only MS sheet metal busbar Chamber on angle iron frame on wall, 4 bars 200 Amps [Ref.- PWD SOR 2017 Ele.Sh. Item no.-6, Page-C-1 ]
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box, including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to lEE regulation and as per direction of EIC. (Brand: Gloster/Havells/Finolex). [a] For Major RLI (i) 4Cx 25 sqmm Copper cable conforming to IS 694 in [100/200 A TPN switch to BUSBAR.] [Ref:-WRIDD SOR 2018 item no -14(i) page no -42]
Fixing only Sheet Steel Main Switch (Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall. (63 Amps) On angle iron frame. [Ref.- PWD SOR 2017 Ele.Sh. Item no.-1, Page-C-1 ]
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box, including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to lEE regulation and as per direction of EIC. (Brand: Gloster/Havells/Finolex) [a] For Major RLI (ii) 3C X 16 sqmm copper cable conforming to IS 694 [Busbar to 63 A, TP Main switch and 63 A TP switch to Motor starter]. [Ref:-WRIDD SOR 2018 , chapter 9, item no -14(ii) page no -42]
Fitting & fixing of Starter (Direct on Line or Star Delta/Auto- Transformer) with Nuts & Bolts fixed on Angle iron frame on wall and making necessary connection with the electrical cables.Star-Delta /Auto-Transformer Starter (Above 15 HP upto 25 HP) [Ref.- WRIDD SOR 2018 , Chapter-9, Item no.-12, Page-42 ]
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box, including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to lEE regulation and as per direction of EIC. (Brand: Gloster/Havells/Finolex). [a] For Major RLI (iii) 2 X 3C X 10 sqmm copper cable conforming to IS 694 in 32 mm GI conduit (lSI-Medium quality) (Star-Delta Motor starter to Motor) [Ref:-WRIDD SOR 2018,Chapter-9,item no -14(iii) page no -42]
Fixing only voltmeter/Ammeter/Energy meter with screws and other fixing material including making necessary holes and connections. [Ref.- PWD SOR 2017 Ele.Sh. Item no.-10, Page no-C-2 ]
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface] (b) Average run 6 meter.[Ref.- PWD SOR 2017 Ele.Sh. Item no.-D-2(b), Page-E-11 ]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: (a) By ISI-Medium GI pipe [Ref.- PWD SOR 2017 Ele.Sh. Item no.-2(a), Page-G-1 ]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts,washers, spacing insulators etc. as required [Ref.- PWD SOR 2017 Ele.Sh. Item no.-4(a), Page-G-2 ]
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. (a) Solid GI wire (iii) No. 8 SWG [Ref.- PWD SOR 2017 Ele.Sh. Item no.-5(a) (iii), Page-G-2 ]
Supply and fixing EI danger board size on wall (b) 20cm.X 30cm (8"X12"). [Ref.- PWD SOR 2017 Ele.Sh. Item no.-21(b), Page-D-13 ]
Supplying and fixing of 240/415 V MCB of breaking capacity 10 kA & C characteristics on DIN rail of existing DBs and necessary connection. Legrand Single Pole 6-32 amp.(PWD elec. 2017 Sh. Page no. D-6, item no.7)
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. (PWD elec. Sh. 2017 Page-D-9, item-11). 2 Way
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection Legrand DP 32 A (PWD elec. Sh. 2017 Page-D-5, item-6
Wiring from MCB SS Enclosure to Busbar by the following size of 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Brand Approved by EIC) in 25 mm PVC casing-capping (Precision make) including necessary PVC clips fittings etc. (PWD elec. Sh. 2017 Page-E-11, item-1c )
2X 36/0.3 (2.5 Sq mm) + 1 X 22/0.3(1.5 Sq mm) ECC
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. (PWD elec. 2017 Sh. Page-D-13, item-22)
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set. (PWD elec. 2017 Sh. Page-D-13, item-23)
Sub-Total
Cost of internal electrical wiring works excluding Labour welfare cess:
Labour welfare cess @ 1%:
Sub-Total
Cost of civil works including Labour welfare cess
Total =
Say Rs.
One Lakh Twenty Eight Thousand One Hundred & Seventy One Only
BoQ_Ver3.0
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Materials.
PCCPOLE: 9 Mtrs. Long
G. I. Earth Spike 1853 x 20 MM
G.I Wire 5 mm
ACSR Rabbit (50 sq. mm.) Conductor
M.S Channel 100X50 mm
M.S Channel 75X40 mm
M.S.Angle 65X65X6 mm
M.S Angle 50X50X6 mm
M.S Flat 65X6 mm
MS V BRACKET 11 KV FOR 9M POLE
MS TOP ADAPTER 11 KV FOR 9M POLE
STAY SET H.T.( safe working load 7900 kg) 1830x20 MM
G.I. Stay Wire 7/3.15 mm (10 SWG)
PORCELIN GUY ISULATOR (HT)
DTR 63 KVA 11/0.415 KV
Lightning Arrester 12 KV 5 KA Porcelain housed gapless type
LT DISTRIBUTION KIOSK FOR 63 KVA DTR
11 KV 320 mm CD Polymer Composite Pin Insulator 5KN
11 KV Polymer Composite 45KN Disc Insulator
Composite Hardware Fittings for ACSR Weasel/ Rabbit Conductor
CABLE PVC 1.1 KV GRADE) 4CX50 sq mm
D IRON CLAMP 3"X 3.5"
PORCELIN SHACKLE INSULATOR 3" X 31/2"
CAUTION BOARD 11 KV
LABOUR: SURVEY OF HT OH LINE
GIS SURVEY OF HT & LT OH LINE IRO POLE(SP, DP, TP,FP & S/STN DP)
ERECTION OF P.C.C. POLE (SP) COMPLETE WITH FITTINGS 9M
ERECTION OF SUB-STN DP STRUCTURE ON PCC POLE (9M) WITH ALL FITTINGS FOR 25 KVA
ERECTION OF EARTHING COMPLETE
FIXING OF SOLID T-OFF ON DP
ERECTION OF HT STAY SET
FIXING OF LIGTNING ARRESTOR 11 KV
FIXING OF DISC INSULLATOR 11 KV
FIXING OF PIN INSULLATOR 11 KV
STRINGING & SAGGING OF ACSR 50 SQ. MM CONDUCTOR 3W
ERECTION OF DISTRIBUTION TRANSFORMER 63 KVA
FIXING OF SHACKLE INSULATOR WITH NUTS & BOLTS
FIXING OF LT KIOSK ON SINGLE SWITCH FOR 63 KVA
FIXING OF SERVICE CONNECTION CHARGE (3-PHASE)
ERECTION OF DTR NEUTRAL PIPE EARTHING
FIXING OF CAUTION BOARD
Quotation
Grand Total
Four Lakh Thirty Five Thousand One Hundred & Seventy Six Only
BoQ_Ver3.0
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Campaigning in the command area of Major RLI Sub-project by community workers for mass awareness , capacity building to achieve sustainability of Sub-projects. Cost include wage payment to community workers, transportaton, leaflet etc.
Meeting Cost for WUA formation, cost including Refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charges
Registration Cost for WUA under suitable act ( Society ) deed writing including registration charge, conveyance cost & opening of Bank A/C etc.
Livelyhood plan / Micro plan formulation cost for minor irrigation scheme, cost including refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charge ( rate on meeting )
Meeting and onsite demonstration for operation & maintenance of one Midi RLI tubewell, water manangement and mode of collection of water tax, building of corpus fund etc
IEC Materials ( Leaflet, poster, notebook )= 8 meetings, for SL - 2 and SL - 4
Documentation Cost for activities of WUA Scheme - by still photography, report booklet etc in both hard and soft copy.
Impact study & monitoring of scheme by site visit of 2 Community workers during 3 years' period
Total
Ninety Eight Thousand Eight Hundred Only
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.87 MB
Tendernotice_2.pdf
PDF • 3.16 MB
Tendernotice_3.pdf
PDF • 1.90 MB
BOQ_2447929.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid