Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹30.7 L+₹89,940 (3.01%)Rejected-Finance R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹33.4 L+₹3.5 L (11.8%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder | |
| 4 | L4₹36.4 L+₹6.6 L (22.1%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 bidder | |
| 5 | L5₹41.0 L+₹11.2 L (37.4%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
18 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS, PIN 913862 C/o 56 APO
GER-52/2022-23Repair/replacement of security lights, garden light, timer switches, cable for security lights etc and repair/maintenance of building lightening protection system and connected earthing at Naushera area under GE 862 EWS
2022_MES_554064_1
GER-52/2022-23
Open Tender
Electrical and Maintenance Works
Works
180 days
GE 862 EWS
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹1 L
Yes
25 Oct 2022
24 Sept 2022
20 Oct 2022
24 Sept 2022
18 Oct 2022
6 Oct 2022
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10sqm on plan for laying of cable and foundation of poles stays and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm (soil) thickness all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed. (Note: Punned thickness of sand shall be measured and paid).
Supplying and laying reinforced precast concrete cable cover, class LV, type 1 flat, size 250mm x 150mm x 40mm complete all as specified and directed.
M&L for PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete of poles and stay/installation paths complete all as specified and directed.
M&L for PCC 1:3:6 (nominal mix) type C-1 using 20mm graded crushed stone aggregates, as in all around the pole and including necessary formwork complete all as specified and directed.
M&L for 50mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, lightening protectioncrossing of roads, laid in trenches, fixed on walls for protection complete all as specified and directed.
M&L for 80mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, lightening protection, crossing of roads, laid in trenches, fixed on walls for protection complete all as specified and directed.
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size16 sqmm 4 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 sqmm 4 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 6 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply, Fixing and testing of street light control panel digital 24 Hrs timer of Max load 6 KW, in an inlcuding of contactor rating 32Amp TP, MCB 40Amp TPN, three phase of IP rating IP-54 with internal wiring of panel with FRLSH cable and with in-built short-circuit protection, including removing old unserviceable panel, complete all as specified and directed (Make: Havells, cat No IHXTS03060 or equivalent of Legrand/ Siemens/ L&T)
Supply, Fixing and testing of street light control panel digital 24 Hrs timer of Max load 6 KW, in an inlcuding of contactor rating 32Amp TP, MCB 40Amp SPN, single phase of IP rating IP-54 with internal wiring of panel with FRLSH cable and with in-built short-circuit protection, including removing old unserviceable panel, complete all as specified and directed (Make: Havells, cat No IHXSS01060 or equivalent of Legrand/ Siemens/ L&T)
S&F for decorative LED Bollard light with diffuers outdoor type LED Bollard light 8W, IP 65 lihgt including all accessories and connecting materials such as clamps, brackets, nut bolts reducer etc with base PCC 1:2:4 fixed on wall/floor and making electrical connection with copper cable complete as in repair all as specified and directed. (Make :- Havells cat No CONEBLS8WLED830PSYMTOPC) or equivalent model of Philips)
S&F for post top lantern light fitting 35/45 watts with cast aluminium spigot lid cover and clear acrylic cover with IP65 protection complete with all accessories including fixing arrangement on top surface of boundary wall or on pillar by providing GI pipe of suitable size and length as per site requirement and making good the distrubed portion to match with existing surface complete as in repair all as specified and directed. (Make:- Havells, Cat Part No. CORALPT35WLED757PSYMTOPC/Crompton greaves, Cat No LPTM-40-CDL/LPTC-40-CDL or equivalent in Philips)
S&F for LED street light fitting 30 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fittings of any type complete as in repeir all as specified and directed (Make:- Crompton, Model No ASTRA NEO LSTS-30-CDL-M or Havells, Cat No ENDURA CITYLITEPLATPLUSSL30WLED757SASYBOPC or equivalent in Philips)
S&F for LED street light fitting 45 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fittings of any type complete as in repeir all as specified and directed (Make:- Crompton, Model No FREEDOM NEO LSTS-45-CDL-M or Havells, Cat No ENDURA PEARL NEO SL45WLED757PASYTOPC or equivalent in Philips)
S&F for LED street light fitting 60 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 66 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fitting of any type complete all as specified and directed. (Make:- Crompton, Model No. ORION NEO LST-60-CDL-M or Havells Cat No. ENDURA PEARLNEO SL60WLED757PASYTOPC or equivalent in Philips)
S&F for 70 watt LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium of IP-66 protection complete with all accessories duly prewired and including fixing arrangement on high mast poles/wall surfaces etc at any height providing clamps, nuts, bolts, and washers etc after taking down old unserviceable flood light fitting of any type complete all as specified and directed. (Make:- Crompton, Model No PROFILE+NEO LFL-70-CDL/60-M or Havelles Cat No. JETAPROFL70WLED757LTG or equivalent in Philips)
S&F for 180 watt LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium of IP-66 protection complete with all accessories duly prewired and including fixing arrangement on high mast poles/wall surfaces etc at any height providing clamps, nuts, bolts, and washers etc after taking down old unserviceable flood light fitting of any type complete all as specified and directed. (Make:- Crompton, Model No PLUTO NEO LFTN-180-CDL/60-M or Havelles Cat No. JETAIRISFLS180WLED757PNBLG/PWBLTG or equivalent in Philips)
M&L for GI bracket pipe of size 25mm dia medium grade of 1.2 mtr long bent to shape hot or cold suitable for street street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket shall be fixed on wall/pole surfaces by providing suitable MS iron 25x4 mm clams 2 Nos of 25 cm long duly to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts, bolts and washers and after taking down old unserviceable GI brakcet of any type complete all as specified and directed.
S&F for FRP looping box of size 200x140x95 with aluminium bus bar (04 Nos) 100 Amps capacity connector and comprising oF MCB SP 6 Amps, ISI marked 240 V, 'C' series/curves complete with including providing GI calmps, nuts bolts etc suitable for fixing on PCC pole/wall etc and after taking down old unserviceable looping box of any type complete all as specified and directed. (Make:- Hensel/Sintex)
M&Lfor earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 25X4mm thick galvanised iron strip by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete after dismantling of old unserviceable earthing with all material etc all as specified and directed. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion after dismantling of old unserviceable earthing with material etc. complete all as specified and directed. (Note:-Earth wire and protection pipe upto board is included in the rate quoted)
S&F for rigid Non metallic PVC conduit of 25mm dia (medium grade) including conduit accessories for encasing the cable from looping box to streel light fittings on PCC poles/on wall surfaces as per site requirement with necessary base saddles etc. all as specified and directed
S&F for copper conductor cable, PVC insulated, sheathed flexible, multistranded ISI marked 1100 volts grade 3 core 1.5 sqmm and including connection and testing and after taking down old unserviceable copper conductor cable complete all as specified and directed.
M&L for complete removal of existing paint from the steel tubular swaged pole of 9 mtr height without removing accessories and preparation of surfaces for repainting the poles with and including two coats of synthetic enamel paint upt 1.50mtr height having alternative white and yellow strips of 30cm height each, including one coat of aluminium paint to the remaining part of pole (i.e above 1.50 mtr height) and its corss arms bracing, support and all steel members complete etc all as specified and directed.
S&F for 300mm long air termination, single pointed, aluminium rod of 12mm dia on the highest point of buildings or as required at site on porcelain base support complete after taking down old unserviceable aluminium air termination rod all as specified and directed
S&F for 300mm long air termination, single pointed, copper rod of 12mm dia on the highest point of buildings or as required at site on porcelain base support complete after taking down old unserviceable copper air termination rod all as specified and directed
S&F for test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head brass screw housed in FRP box duly locking arragement including connecting down conductor and eath strip/wire after taking down old unserviceable test point terminal block complete all as specified and directed.
S&F for 25x3.15mm Aluminium strip with saddles and fixing screws etc. for roof conductors and down conductors above ground of any type of wall surfaces with necessary fixing arrangment by providing porcelaing base at 60cm inter bal and using cadmium plated fixing screw and insulator par running meter all as required at site complete after dismantling of old unserviceable aluminium strip all as specified and directed. (Note:- 1. Strip will be installed on saddles in such a way that in no case the aluminium strip comes in direct contract with pole. 2. aluminium strip will be fixed epoxy base insulators of suitable size and rates were deemed to be included in quoted prices).
S&F for 20 x 3.15mm Copper strip with saddles and fixing screws etc. for roof conductors and down conductors above ground of any type of wall surfaces with necessary fixing arrangment by providing porcelaing base at 60cm inter bal and using cadmium plated fixing screw and insulator par running meter all as required at site complete after dismantling of old unserviceable copper strip all as specified and directed. (Note:- 1. Strip will be installed on saddles in such a way that in no case the copper strip comes in direct contract with pole. 2. copper strip will be fixed epoxy base insulators of suitable size and rates were deemed to be included in quoted prices).
S&F for32x6mm Copper strip with saddles and fixing screws etc. for roof conductors and down conductors above ground of any type of wall surfaces with necessary fixing arrangment by providing porcelaing base at 60cm inter bal and using cadmium plated fixing screw and insulator par running meter all as required at site complete after dismantling of old unserviceable copper strip all as specified and directed. (Note:- 1. Strip will be installed on saddles in such a way that in no case the copper strip comes in direct contract with pole. 2. copper strip will be fixed epoxy base insulators of suitable size and rates were deemed to be included in quoted prices).
M&Lfor earthing complete with copper earth plate electrode 600x600x3.15mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 20x3 thick copper strip for from earth electrode to test point/ equipment of upto 7.5 m whichever is less by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete after dismantling of old unserviceable earthing with all material etc all as specified and directed. (Note:-Earth strip and protection pipe upto test point/equipment upto 7.5m is included in the rate quoted)
M&Lfor chemical earthing pit with copper earth plate of size 900mm x 600mm x5mm thick buried directly in ground vertically to a depth not less than 4m below normal ground level, connected to & including 32 x 6 mm copper strip by means of nuts, bolts check nuts and washers made of copper and connected to test point including brazing and excavation and earth work in any type of soil, with charcoal 250 Kg, crystal salt 200 Kg, magnesium sulphate of 100 Kg and vegatable soil all around the plate 35 cm depth bottom to top of the plate full width of pin including PCC 1:3:6 type C1 in chamber of internal size 300mm x 300mm x 300mm with wall thick ness of 120mm and 700mm x 700mm x 150mm bed concrete, precast PCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 kg/Sqm) with cast iron frame, funnel, with wire mesh, 25mm bore medium grade GI pipe, lugs, 80mm bore medium grade GI protection pipe, test point etc complete after dismantling of old unserviceable earthing with all material etc all as specified and directed. (Note:-Earth strip and protection pipe upto 7.5m is included in the rate quoted)
S&F for erath continity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as requuired 4mm dia galvanized iron or steel wire and removing old unserviceable wire complete all as speicified and directed
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
M/S Chib Engineers
M/S PARSHOTAM KUMAR GUPTA
Jiwan Singh
BINDRA ENGINEERS AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .